What was found
(THIRD GRIPE) APU SWITCH EXTENDS BEYOND START, THEN RETURNS TO START VICE ON POSITION. NEEDS ADJUSTMENT. APU OPERATES 4.0.(<P>TRANSFERRED TO MDDR 126667 IAW DDG 49-11-01A, CAT C, DUE DATE 14APR2020.</P><P>LOG PAGE 1150016 ITEM 2: REMOVED AND REPLACED APU ROTARY SWITCH PER SWPM 20-84-00. OPS CHECKED NORMAL. THIS CLEARS MDDR 126667. PLACARD REMOVED.</P>)