Boeing 767-3Y0
Service difficulty reports · 1,443
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2019010400017Escape Reel · unwanted deploy01 EA INERTIAL ESCAPE REEL DEPLOYED IN THE COCKPIT - 06 REELS STILL AVAILABLE FOR USAGE(<P>TRANSFER TO DMI 105285 PER MEL 25-61-01-01 CAT C MBCB 10JAN19 MPCW PLACARD INSTALLED. </P><P>REMOVE AND REPLACED DESCENT DEVICE IAW AMM 25-61-00 THIS CLEARS MDDR 105285 SDR P5CA2019010300002Not Reported · malfunctionedON GND (TAXI) CENTER FUEL TANK QUANTITY INCREASES SLOWLY 0 TO 12. C/W FQIS BITE IAW AMM 28-41-00. NO DEFECTS NOTED PER MCC REQUEST VERIFIED OP0S OF REFUEL AND DEFUEL VALVES VERIFIED FUEL IS IN FACT MIGRATING INTO CENTER TANK FROM WING TANKS FURTHER T/S REQUIRESDR P5CA2018122650390Windshield · arcedCAPTAINS LOWER WINDOW INTERMITTENTLY ARCING/SPARKING IN FLIGHT. APPEARS TO BE COMING FROM ELECTRICAL STRIP IN WINDOW BURN MARKS PRESENT.(<P>REMOVED AND REPLACED 1L WINDOW IAW B767 AMM 56-11-01-004-039 AND B767 AMM 56-11-01-404-017. OPS CHECK GOOD. WINDOW PNSDR UIEA2018122302911Igniter · failedAPU FAILED TO START (<P>REMOVED AND REPLACED APU EXCITER IAW 49-41-03 OPS CKD OK REMOVED AND REPLACED IGNITOR IAW AMM 49-41-02 OPS GOOD</P>)SDR UIEA2018121972864Warning Message · false activationAPU BAT CHARGE STATUS MESSAGE (<P>PERFORMED FIM 24-31 FT 805 MESAGE CLEARED APU BATTERY 28V </P>)SDR UIEA2018121702854Battery · defectiveAPU BAT CHGR STATUS MSG. REPLACED APU BATTERY, SYSTEM CHECK GOOD IAW AMM 24-31-04.SDR UIEA2018121702862Indication Sys · false indicationENG 3 FAN VIBRATION INDICATOR OF UP TO 4.5 DURING CLIMB NO PHYSICAL VIBRATION. INSPECTED INLET AND EXHAUST AREAS CHECKED FOR LOOSE DUCTS ON ENG AND NONE FOUND OK FOR SERVICE REF AMM 71-00-00.SDR P5CA2018121700389Connector · looseDURING DESCENT EICAS MSG "LH ENG ANTI-ICE WHEN SELECTED OFF" NOTE: LP 1024911 - (LAX) PER ATLAS REQUESWT DO INTEGRITY TEST OF PNEUMATIC AND L ENG ANTI-ICE VALVE(<P>MSG CLEARED AND VERIFIED NOT PRSDR P5CA2018121760388Shutoff Valve · malfunctionedDURING DESCENT EICAS MSG " LH ENG ANTI-ICE" ASSOCIATED VALVE LIGHT ON LH ENG ANTI-ICE AFTER TURNING IT OFF(<P>ASSOCIATED WITH PRSOV EICAS MSG ENG INLET TAI SYS TEST IAW B767 30-21-00-735-001 OPS CHK NORMAL</P><P>(NOTE: SEE ITEM LP 1024907 - 1 - LH BLEED OFF MESDR P5CA2018121760387Shutoff Valve · malfunctionedEICAS MSG " LH ENG BLEED OFF" & " LH PACK OFF" APPEARED TWICE DURING CLIMB @ APROX 11,000 FT(<DIV>R&R PRSOV IAW B767 AMM 36-11-09-002-133-008 LH ENG #1, RAN ENG OPS CHECK NORMAL.</DIV>)SDR UIEA2018121702860Unknown · malfunctionedMAIN DECK SMOKE DET LOOP A INOP. PERFORMED TEST OF DETECTION SYSTEM IAW AMM 26-14-00, NO FURTHER DEFECTS NOTED.SDR P5CA2018121740386Controller · malfunctioned"LEFT ENGINE BLEED OFF"," LEFT PACK OFF" CAUTION MESSAGES APPEARED TWICE AT APPROX, 10,000' ON CLIMB OUT. REPEAT WRITE-UP.(<P>T/S PER FIM 36-10 FT 837 REMOVED AND REPLACED LT ENG PRV CONTROLLER PER AMM 36-11-19-004-001-002 RAN ENG AND OPS CHECKS OK FOR SERVICESDR P5CA2018121320381Duct · low pressureDURING CRUISE WITH ANTI-ICE ON L DUCT PRESS DROPS TO 5 PSI WITH INTERMITTENT L BLEED OFF EICAS.(<P>T/S PER FIM 36-10 F/T 837. CKD ALL LINES FOR PROPER CONDITION RE-TORQUE ALL B NUTS CKD WIRING CLEANED CONNECTOR RAN ENG NO FAULTS, A/C OK FOR SERVICE.</P>)SDR P5CA2018121200378Duct · low pressureW/ ENGINE ANTI-ICE ON LEFT DUCT PRESSURE DROPS TO 7 PSI AND MOMENTARILY L ENG BLEED OFF EICAS(<DIV>NO FAULT SHOWN IN STATUS PG. BITE CHK IN THE AIR SUPPLY BITE MODULE, NO FAULT IAW AMM 36-23-00-715. ITEM CLOSED, OKAY TO CONTINUE.</DIV>)SDR UIEA2018120902805Unknown · malfunctionedAPU WILL NOT START. PERFORMED APU BITE PROCEDURE IAW AMM 49-11-00 F/T 815, NO FAULTS AT THIS TIME. APU OPS CHECK NORMAL IAW AMM 49-11-00.SDR P5CA2018121080372Warning Message · false activationRIGHT FWD WINDOW EICAS DURING CRUISE AT FL 350. HAPPENED DURING APU COLD START VERIFICATION (<P>PERFORMED PIT CHECK ON RIGHT FWD CONTROLLER FOR WINDOW HEAT IAW AMM 30-41-00. BIT CHECK GOOD AT THIS TIME </P>)SDR UIEA2018120702793Unknown · malfunctionedDURING 2 HOUR VERIFICATION FLIGHT, EXPERIENCED 2 FUEL MIGRATIONS FROM LT TO RT OF 1500 LBS BOTH TIMES. PERFORMED OPS CHECK OF ENGINE FUEL FEED SYSTEM AND INSP OF FUEL TANKS FOR LEAKAGE PER AMM 28-22-00 AND 28-11-00. COULD NOT DUPLICATE FUEL TRANSFER FIND EXTERSDR P5CA2018120750369Valve · making metalLH ENG BLEED OFF MESSAGE INTERMITTENT ON TAKEOFF AND CLIMBOUT(<P>TRANSFERRED TO MEL 36-11-08-01-01A, MDDR # 103939 CAT C DUE 15DEC18</P><P>(NOTE: PRV INOP IN OPEN POSITION, HPSOV BLOCKED CLOSED AND FAN AIR VALVE BLOCKED IN THE INTERMEDIATE POSITION PER DDG PRSDR UIEA2018120302766Relay · malfunctionedFWD EQUIP EXHAUST FAN STATUS MESSAGE. REMOVED AND REPLACED CURRENT SENSOR RELAY IAW SWPM 20-81-00. OPS CHECK GOOD IAW FIM 21-58 FT 905, NO DEFECTS NOTED AT THIS TIME.SDR P5CA2018120300366Warning Message · false activationAFTER LANDING: R FWD WINDOW MSG(<P>PERFORMED OPS CHECK R FWD WINDOW HEAT IAW B767 AMM 30-41-00 OPS CHECK GOOD COULD NOT DUPLICATE AT THIS TIME.</P>)SDR UIEA2018120302765Unknown · malfunctionedON BATTERY PWR STBY PWR DID NOT WORK. PERFORMED STANDBY OPERATIONAL TEST IAW AMM 24-33-00 TEST OK AT THIS TIME.SDR UIEA2018113002741Oil System · lowAPU WILL NOT START NO LIGHT OFF (<P>TRANSFERRED TO MDDR # 103645 AS PER MEL 49-11-01A CAT C </P><P>LOG PAGE 1016942 SERVICED APU OIL WITH 01 QT I.A.W AMM 12-13-04 , APU OPERATES NORMALLY AT THIS TIME AS PER AMM 49-11-00.SDR P5CA2018112980365Elt · unsecurePORTABLE ELT TETHER IS NO LONGER SECURED TO THE (<P>REMOVED AND REPLACED ELT IAW AMM AMM 25-63-00</P>)SDR UIEA2018112762703Symbol Generator · malfunctionedFOR WXR ON TERRAIN MUST BE SELECTED ON AND OFF SEVERAL TIMES BEFORE E(<P>LOADED NEW EFIS SYMBOL GENERATOR IAW AMM 34-22-00 OPS CKS GOOD </P>)SDR UIEA2018112602700Radar · malfunctionedWX RADAR OR TERRAIN MUST BE SELECTED ON AND OFF SEVERAL TIMES BEFORE ENGAGING (<P>ACCOMPLISHED OPERATION CHECK OF WXR AND TERR IAW AMM 34-43-00 AND AMM 34-46-01 OPS CHECK NORMAL </P>)SDR P5CA2018111980352Connector · looseRIGHT FWD WINDOW EICAS MESSAGE (<P>NOTED BY MAINTENANCE</P><P>REF LOG PAGE 1024717 ITEM M8; TROUBLESHOT RIGHT WINDOW HEAT FAULT IAW WDM 30-41-12. FOUND CONNECTOR D1668 ON WINDOW LOOSE. RE SECURED CONNECTOR AND OPS CHECK RIGHT WINDOW HEAT IAW AMM 30-41-00. OPS SDR UIEA2018112102670Escape Rope · unwanted deployDESCENT DEVICE DEPLOYED ON LANDING(<P><SPAN>REMOVED / AND REPLACED DESCENT DEVICE IAW SPECIAL FREIGHTER MAINT MANUAL 25-61-03</SPAN></P>)SDR UIEA2018112102675Oxygen Bottle · leakingPAX O2 BOTTLE 2 IS LEAKING, VALVE TO OPEN BOTTLE IS SLIGHTLY BENT AND VALVE HANDLE IS VERY LOOSE.(<P><SPAN>INSTALLED / NEW O2 BOTTLE IN POS 2 IAW B767 AMM REF 12-15-08, NO LEAKS NOTED </SPAN></P>)SDR UIEA2018111602635Seal · leakingLH AC PACK GROUND AIR SUPLLY DUCT COUPLING LEAKING AIR(<P>REMOVED AND REPLACED PERI SEALS AT LH FD CROSSOVER DUCT AND PERFORMED GOOD LEAK TEST IAW AMM 36-11-01</P>)SDR UIEA2018111602634Seal · leakingRH ECS BAY AFT LWR CROSSOVER DUCT O/B OF VALVE IS LEAKING(<P>REMOVED AND REPLACED RH ECS BAY AFT LOWER CROSSOVER DUCT SEALS IAW AMM 36-11-01, NO LEAK DETECTED.</P>)SDR UIEA2018111602633Doubler · corrodedCORROSION AROUND DOUBLER AT 7 O' CLOCK POSITION IN FAN CASE ENGINE #1(<P>ACCOMPLISHED REPAIR IN ENG #1 FAN CASE AT 7 O'CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01.</P><P><BR DATA-MCE-BOGUS="1" /></P>)SDR UIEA2018111602632Doubler · corrodedCORROSION AROUND DOUBLER AT 5 O'CLOCK POSITION IN FAN CASE ENG #1(<P>ACCOMPLISHED REPAIR ON ENG #1 FAN CASE AT 5 O'CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01</P>)SDR UIEA2018111402606None · noneEVIDENCE OF BIRD INGESTION ON ENG #1 INLET COWL AT 1230 POSITION (FACING ENG) AND OUTLET GUIDE VANE AT 1130 POSITION(<P>COMPLETED GVI #1 ENGINE NOSE COWL AND ENGINE INTAKE AND FOUND EVIDENCE OF BIRD STRIKE AT 1230 POSITION ON INLET COWL IAW B767 AMM 05-51-18. SDR UIEA2018111602631Doubler · corrodedCORROSION AROUND DOUBLER AT 6 O' CLOCK PSOTION IN FAN CASE #1 ENGINE(<P>ACCOMPLISHED REPEAIR ON ENGINE #1 FAN CASE AT 6 O' CLOCK POSITION IAW GE CF6-80C2 ENGINE MANUAL 72-22-01.</P>)SDR UIEA2018111602630Smoke Detector · cloggedFWD CARGO COMPARTMENT CEILING HAS CLOGGED SMOKE DETECTION AT BS 502 LBL 5(<P>CLEANED AND UNBLOCKED SMOKE DETECTI TUBE IAW BOEING SOPM 20-30-03</P>)SDR UIEA2018111642615Heat Shield · torn#1 ENG COOLING DUCT HEAT SHIELD SECTION IS TORN, APPROX 3 O CLOCK POSITION JUST AFT OF THE UPPER IGNITER PLUG.(<P>REMOVED AND REPLACED HEAT SHIELD INSULATION BLANKET ON #1 ENGINE DUCT AT 3 O' CLOCK POSITION IAW GE CF680C2 ESM 72-00-0</P>)SDR UIEA2018111642613Case · corrodedCORROSION AROUND 3EA FASTENERS HOLES ON #1 ENG FAN CASE EXTERNAL SURFACE, LOCATED APPROX BETWEEN 7 AND 8 O CLOCK POSITION AND JUST BELOW THE ECU(<P>REMOVED CORROSION, EVALUATED AREA AND FOUND WITHIN LIMITS IAW GE CF6-80C2 ENGINE MANUAL 72-22-01. TREATED AND PRSDR UIEA2018111642612Control Valve · unknownREMOVE SURGE CONTROL VALVE AND INSTALL TROUBLESHOOTING SURGE CONTROL VALVE FOR TROUBLESHOOTING PURPOSES.(<P>REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW B767 AMM 49-53-01. PERFORMED SATISFACTORY OPS AND LEAK CHECK, NO DEFECTS NOTED.</P>)SDR UIEA2018111642610Fan · damagedEQUIPMENT COOLING FAN SATURATED WITH OIL AND NICKS ON FAN BLADES(<P>REMOVED AND REPLACED EQUIPMENT COOLING FAN IAW AMM 2-58-06</P>)SDR UIEA2018111642614Sense Line · chafedLH WING TO BODY AREA, BLEED AIR DUCT SENSE LINE RUBBING AGAINST AROUND STUD INSIDE ACCESS PANEL #193KL(<P>REMOVED AND REPLACED BLEED AIR SENSE LINE IAW AMM 20-10-09. PERFORMED LEAK CHECK, NO LEAKS NOTED IAW B767 AMM 36-11-00.</P>)SDR UIEA2018111642611Support Bracket · corrodedRH WING T/E SUPPORT BRACKET I/B OF #9 SPOILER HAS EXFOLIATING CORROSION(<P>UPON EVALUATION FOUND SUPPORT BRACKET OUT OF LIMITS DUE TO 100% MATERIAL LOSS, REPAIRED BRACKET IAW B767 SRM 51-70-12 DETAIL III</P>)SDR UIEA2018111642609Strap · corrodedLH AFT WTB FAIRING STRUCTURE TO FUSELAGE STRAP BS 1175 CORRODED(<P>REMOVED CORROSION AT LH AFT WTB FAIRING STRUCTURE TO FUSELAGE STRAP BS 1175 FOUND WITHIN LIMITS IAW B767 SRM 53-00-71</P>)SDR UIEA2018111642608Strap · corrodedLH AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 CORRODED.(<P>REMOVED CORROSION AT LH AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 FOUND WITHIN LIMITS IAW B767 SRM 53-00-71</P>)SDR UIEA2018111642607Strap · corrodedRT AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 CORRODED 111-40(<P>REMOVED CORROSION AT RT AFT WTB STRUCTURE FUSELAGE STRAP BS 1109 FOUND WITHIN LIMITS IAW B767 SRM 53-0-71 AND SRM 51-10-02, TREATED, PRIMED, AND TOP COATED AREA IAW B767 SRM 51-20-01</P>)SDR P5CA2018110800347Warning Message · false activationR FWD WINDOW EICAS MSG ON LANDING(<P>RESET AND ACCOMPLISHED R WINDOW HEAT BITE IAW AMM 30-40-00 OPS CHECKED NORMAL AT THIS TIME</P>)SDR P5CA2018110500341Warning Message · false activationLEFT ENGINE EEC C1 STATUS MESSAGE. PERFORMED A PIMU BITE IAW FIM 71-01-00/101. BITE TESTED GOOD. MESSAGE CLEARED.SDR P5CA2018110200339Pump · malfunctionedFUEL MIGRATION TO CENTER TANK FROM UNKNOWN ORIGIN, WHEN CENTER PUMPS WERE TURNED ON, THE CTR LT AND CTR RT FUEL PUMP EICAS MESSAGE DISPLAYED, ORH DIRECTS TO TURN OFF THE PUMPS, NOT ALLOWING FULL USE OF FUEL MIGRATING TO CENTER TANK. OK FOR SERVICE IAW SERVISDR P5CA2018103000336Warning System · false activationPER FLIGHT CREW DEBRIEF, LT ENG EEC C1 SHOWN IN STATUS PAGE. NO OTHER INDICATIONS CAME WITH IT. LT PIMU & RT PIMU MSG SHOWN IN MX PG. ACCOMPLISHED EICAS RESET IAW AMM 31-41-00-752 FAULT CLEARED. CHKD LRU NO FAULT LOGGED IN MEMORY . ACFT OK TO CONTINUE.SDR P5CA2018102900335Circuit Breaker · trippedRT ENGINE IGNITER 1 STATUS MESSAGE(<P>FOUND C/B M2 ON P11 PANEL LEFT OUT. RESET CIRCUIT BREAKER AND PERFORMED ENGINE IDLE RUN IAW AMM 71-00-00 OPS CHECKS OK </P>)SDR P5CA2018102900334Circuit Breaker · trippedLT ENG IGNITOR 1 STATUS MESSAGE(<P>FOUND CIRCUIT BREAKER M1 ON P11 PANEL OUT. RESET BREAKER AND PERFORMED ENGINE IDLE RUN IAW AMM 71-00-00 OPS CHECKS GOOD.</P>)
Back to Boeing 767-3Y0