SDR UIEA2018102702385Valve · faultyLEFT IDG VALVE STATUS MESSAGE. PERFORMED FIM UP TO BLOCK 4 24-20 FAULT TREE 802, NO DEFECTS NOTED AT THIS TIME PER CHECK. IDG DELTA P NO DEFECTS RAN ENGINES IAW AMM 71-00-00 NO FAULTS NOTED. REMOVED AND REPLACED THE LEFT ENGINE IDG VALVE AMM 24-11-12. PERFORMESDR UIEA2018102602349Relay · failedLT IDG VALVE STATUS MSG. PERFORMED FIM TASK 24-20 FT 802. R&R IDG VALVE FAILURE RELAY (K1033) IAW SWPM 20-81-11 NO FAULTS NOTED. MSG CLEARED.SDR UIEA2018102102301Status Message · false activationLT IDG VALVE. MSG CLEARED IAW FIM 24-20 FT 802.SDR UIEA2018102102302Warning System · false activationCTR LEFT FUEL PUMP LIGHT ILLUMINATED WITH 1.1 K IN CENTER IN TANK. PERFORMED OPS CHECK PER AMM 28-42-00, ALL CHECKS OK NO FAULTS NOTED.SDR UIEA2018102102310Status Message · false activationCABIN ALT AUTO 1 STATUS MESSAGE DISPLAYED. PERFORMED BITE TEST IAW AMM 21-31-00. MESSAGE CLEARED, OPS CHECK OK NO FAULTS AT THIS TIME.SDR UIEA2018102102308Bleed Air Sys · low pressureLOW APU BLEED PRESSURE DURING LEFT ENGINE START DISCONTINED START AND PERFORM A X BLEED START. UNABLE TO DUPLICATE CONDITION PERFORMED APU OPS TEST IAW AMM 49-11-00 OPS CHECK OK.SDR UIEA2018102202315Bleed Air Sys · fluctuatesLT ENG START DUCT PRESS FLUCTUATED 10-20 PSI MAX N2 OF 14, DISCONTINUED. START CROSSBLEED START ACCOMPLISHED NORMALLY. PERFORMED APU OPS TEST IAW AMM-49-11-00, NO FAULTS NOTED. OPS CHECK GOOD. UNABLE TO DUPLICATED CONDITION.SDR UIEA2018102202316Apu · malfunctionedAPU INOP. TRANSFER TO MDDR 101463 IAW MEL 49-11-01A CAT C DUE DATE 30-OCT-18.SDR P5CA2018101900328Not Reported · damagedL ENG BYPASS EPOXY CHIPPING(<P>TRANSFERRED TO NON MEL 101238.<BR /></P>)SDR P5CA2018101900327Warning System · false activationFWD R WINDOW HEAT EICAS MSG AFTER LANDING(<P>RESET ACCOMPLISHED R WINDOW HEAT BITE TEST IAW AM 30-40-00 OPS NORMAL NO FAULT<BR /></P>)SDR P5CA2018101500321Warning System · false activationRIGHT WINDOW EICAS MESSAGE. PERFORMED TEST AMM 30-41-06-715-001 AND AMM 30-41-765-046. OPS CHECK GOOD AT THIS TIME OK FOR SERVICE.SDR UIEA2018101502267Unknown · malfunctionedRADAR SPIKES INTERMITTENTLY. OPS CHECK RADAR IAW AMM 34-43-00 AND FIM 34-43 FAULT TREE 805, NO FAULTS NOTED AT THIS TIME.SDR P5CA2018101500320Connector · defectiveRT FWD WINDOW EICAS MESSAGE AFTER LANDING(<P>REPLACED CONNECTOR 28998B IAW AMM 30-41-12SHEET 2 AND SWPM 20-71-11 OPS CHECK NORMAL FOR CONTINUED FOR SERVICE<BR /></P>)SDR P5CA2018101700324Connector · not reportedR FWD WINDOW EICAS AFTER LANDING. REPLACED CONNECTOR 2898B IAW WDM 30-41-12 SHEET 2 AND SWPM 20-71-11. OPS CHECK NORMAL. OK FOR CONTINUED SERVICE.SDR P5CA2018101100314Anti-Ice System · malfunctionedR FWD WINDOW INOP. RESET AND ACCOMPLISHED R WINDOW HEAT BITE IAW AMM 30-40-00 OPS NORMAL.SDR UIEA2018101102238Not Reported · malfunctionedFO RADAR DISPLAY TURNS OFF THE RADAR. PERFORMED WX RADAR OPERATIONAL TEST IAW AMM 34-43-00 & SYSTEM TEST IAW AMM 34-43-00. OPS CHECKED GOOD. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018101002218Not Reported · malfunctionedINTERMITTENT RADAR SPIKES ON RADAR RETURNS. PERFORMED WX RADAR OPS TEST PER AMM 34-43-00. OPS TEST OK AT THIS TIME.SDR UIEA2018101002219Warning System · false activationSTATUS MESSAGE LEFT IDG VALVE. PERFORMED BITE TEST OF BPCU FOUND NO FAULT AND RESET BOX MESSAGE CLEARED IAW AMM 24-11-00.SDR UIEA2018100902215Switch · defectiveLEFT ENGINE OIL PRESSURE LIGHT INOP. INSPECTED L ENG OIL PRESS LIGHT LIGHTED PUSH BUTTON ASSY IAW SWPM 20-84-18. FOUND NR 1 & 2 SPRING LOADED CONTACTS TO BE WEAK, ALSO FOUND NR 2 CONTACT TO BE BROKEN OFF INSIDE BASE ASSY. CRIMPED NEW CONTACT AND WIRE IAW WDM 7SDR UIEA2018100802208Unknown · malfunctionedF/O MFD DOES NOT DEPICT WEATHER WHEN SELECTED NOR TERRAIN WHEN SELECTED. PERFORMED OPERATION TEST ON F/O WEATHER RADAR IAW AMM 34-43-00. OPS CHECK NORMAL, NO DEFECTS AT THIS TIME.SDR UIEA2018100902212Iru · out of alignmentFO'S WXR AND TERR SELECT SWITCHES INTERMITTENLY DONT FUNCTION WHEN NEEDED. ALIGNED IRU'S AND CYCLED THROUGH CAPT AND FO'S WX AND TERR SWITCHED SEVERAL TIMES IN BOTH TEST AND WX POSITION. OPS CHECKED OK IAW AMM 34-43-00.SDR UIEA2018100902214Sensor · defectiveRIGHT PACK INOP. R&R MIX MANIFOLD SENSOR IAW 21-61-02. OPS CHECK NORMAL AT THIS TIME.SDR UIEA2018100702196Unknown · malfunctionedAPU INOP. PERFORMED APU RUN THREE TIMES AND PUT LOAD ON IAW AMM 49-11-01, DUCT PRESSURE 30 PSI PERFORMED BITE IAW FIM 49-11 F/T 958. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018101102237Ecu · malfunctionedAPU INOP. REPLACED ECU PER AMM 49-61-05 OPS CHECKS GOOD. TESTED APU, CYCLED APU BLEED VALVE 4 TIMES, OPS CHECKED GOOD.SDR UIEA2018100802199Connector · contaminatedCTR L FUEL PUMP MSG DISPLAYED AFTER ENG START, LEFT C PUMP DISPLAYED PRESSURE LIGHT. PERFORMED VOLTAGE CHECK AT LT CENTER FUEL PUMP AT PINS 2,4,6, 115VOLTS AC PERFORMED VOLTAGE CHECK AT LT FUEL OVRD PUMP CONT RELAY AT PINS A2,B,C2 115 VOLTS AC NOTED, THEN ALSOSDR UIEA2018100402182Clamp · out of positionAPU BLEED PRESS LOW. TROUBLE SHOOT PER FIM 49-11 FT 979, FOUND EXCESSIVE AMOUNT OF BLEED AIR LEAKING FROM SURGE VALVE. REPOSITIONED AND SECURED CLAMPS, OPS CHECK GOOD.SDR P5CA2018100400307Warning System · activatedEICAS : R FWD WINDOW MSG(<P>MX TROUBLE SHOOTING IN WORK @ SFO<BR /></P>)SDR UIEA2018100302181Status Message · false activationSTATUS MSG AFT EQ EXH FAN 2. COMPLIED WITH SYSTEM TEST IAW AMM 21-58-41 CHECKS GOOD, ERASED STATUS MSG PER AMM 31-41-00.SDR P5CA2018100400306Warning System · false activationEICAS RT FWD WINDOW(<P> PERFORMED WINDOW HEAT BITE IAW AMM 30-41-00 TEST PASSED OPS CK GOOD<BR /></P>)SDR UIEA2018100302175Unknown · malfunctionedINFLIGHT CTR RT FUEL PUMP EICAS MSG DID NOT ANNUNCIATE/DISPLAY EVEN WHEN THE CENTER FUEL TANK WAS DOWN TO 0.0 QUANTITY, NO PRESS LIGHT ON THE SWITCH LIGHT EITHER. T/S PER FIM 28-22 COULD NOT DUPLICATE ON GROUND.SDR UIEA2018100302173Pump · faultyCTR LEFT & CTR RIGHT FUEL PUMP PRESS LIGHT CHECKS ON AND OFF WITH 0.7 IND IN CTR TANKFUEL. RIGHT CTR FUEL PUMP OPS CHECK NORMAL IAW AMM 28-42-01 LT CTR FUEL PUMP TRANSFERRED TO MDDR 100526 PER MEL 28-22-02A CAT C DUE DATE 12 OCT 18 PLACARD INSTALLED M PROCEDUSDR P5CA2018100100305Connector · defectiveREPEAT WRITE UP - ON TAXI IN RT FWD WINDOW EICAS . CW WITH QRH AND MSG CLEARED(<DIV>LOG PAGES 0965135-3, LOG PAGE 0965137-07 AND -08 : TS PER WDM 30-41-012 CW CONTINUITY CHECKS FROM R1 WINDOW J1,J5,D1914,D1912 TO WINDOW HEAT CONTROLLER AND FROM CONT PANEL TO SDR UIEA2018100202168Tru · faultyAPU FAIL TO START AFTER LANDING. R&R APU TRU IAW AMM 24-32-04, OPS CKD GOOD.SDR UIEA2018092802119Pressure Switch · leakingFUEL LEAK BY PRESSURE SWITCH LEFT FWD FUEL PUMP. REMOVED AND REPLACED LEFT PRESSURE SWITCH ON FWD FUEL PUMP IAW AMM 28-43-01.SDR UIEA2018092802123O-Ring · damagedAPU OIL QTY TRANSMITTER LEAKING. REMOVED AND REPLACED OIL QTY TRANSMITTER O RING, NO LEAKS NOTED IAW AMM 49-94-04.SDR P5CA2018100100302Warning System · false activationR FWD WINDOW EICAS(<P>RESET R FWD WINDOW HEAT AND ACCOMPLISHED WINDOW HEAT BITE IAW AMM 30-41-00 OPS NORMAL<BR /></P>)SDR UIEA2018092302035Sensor · dirtyAPU INOP. CLEANED SENSOR IAW AMM 49-53-08. PERFORMED SUPPLY PRESSURE INDICATING SYSTEM. OPERATIONAL CHECK GOOD AT THIS TIME.SDR UIEA2018092302037Status Message · false activationLT IDG VALVE STATUS MESSAGE. UPON INSPECTION NO MSG FOUND, CHECK CIRCUIT BREAKER AND FOLLOWED MAINT PROCEDURE PER FIM 24-11-00. OPS CHECK GOOD, NO STATUS MSG. A/C IN NORMAL CONDITION AL TIHIS TIME.SDR P5CA2018100100301Terminal · looseON TAXI IN RECEIVED R FWD WINDOW EICAS. COMPLIED WITH QRH, MESSAGE CLEARED(<P>T/S PER FIM 30-41 F/T 804. FOUND POWER J1 TERMINALS LOOSE. TIGHTENED TO AMM VALUE 25 IN/LB. ALL OPS CHECKED. OK FOR SERVICE<BR /></P>)SDR UIEA2018092202029Sensor · faultyRT PACK AUTO SHUT DOWN (WILL WORK IN STANDBY). R&R RT COMPRESSOR TEMP SENSOR TS42 IAW AMM 21-51-06 OPS CHECK AND SATISFACTORY BITE AT PACK CONTROLLER ALL OK.SDR UIEA2018092502062Warning System · false activationSTATUS MSG LT IDG VALVE. T/S PER FIM 24-20 FT 802 , NO FAULTS NOTED, CLEANED CONNECTOR D11046. BIT BPCU PER FIM MSG CLEARED. RUN L ENGINE AND FAULT COULD NOT BE DUPLICATED REF AMM 71-00-00.SDR UIEA2018092102028Connector · dirtyRT PACK TEMP CAUTION AFTER LANDING. PERFORMED BITE CHECK IAW 21-51-14. FOUND COMPRESSOR OUTLET FAULT, CHECKED SENSOR. REMOVED CONNECTOR AND CLEANED/RE-SECURED IAW AMM 21-52-01, CLEARED FAULT. FAULT DID NOT RETURN.SDR P5CA2018092400288Warning System · false activationRT FWD WINDOW EICAS MSG RECEIVED ON TAXI IN. COMPLIED WITH QRH. MSG CLEARED. PERFORMED WINDOW HEAT BITE IAW AMM 30-41-00, NO FAULTS PRESENT.SDR P5CA2018091800286Controller · malfunctionedRT FWD WINDOW EICAS AFTER LANDING, RESET WITH SWITCH. REMOVED AND REPLACED WINDOW HEAT CONTROLLER IAW AMM 30-41-01 OPS CHECKED GOOD.SDR UIEA2018091301962Warning System · false activationSTATUS MSG AFT EQ EXH FAN 2. MSG CLEARED AND AFT EQ EXH FANS TEST OK PER AMM 21-26-01.SDR P5CA2018090700216Shutoff Valve · faultyLT IDG VALVE STATUS CAME ON IN CRUISE. LT IDG AIR S/O VALVE T/S PER FIM 24-00 FT 802, ALL WIRING CHECK OK. REMOVED AND REPLACED LT IDG AIR S/O VALVE IAW 24-11-01/201. OPS CHECKED GOOD.SDR UIEA2018090501899Module · malfunctionedAPU AUTO SHUT DOWN. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-33-03. OPS CHECK GOOD.SDR P5CA2018090700215Warning System · false activationDURING TAXI IN RT FWD WINDOW HEAT EICAS MESSAGE, COMPLIED WITH QRH AND EICAS MESSAGE CLEARED. ACCOMPLISHED WINDOW HEAT BITE TEST IAW AMM 30-40-00, OPS GOOD.SDR UIEA2018090301873Module · faultyAPU NO DUCT PRESSURE. PERFORMED BITE CHECK IAW FIM 49-11 FT 975. FAULTY PT SENSOR, REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-00. OPS CHECK GOOD, NO FAULTS NOTED.SDR UIEA2018082101758Unknown · malfunctionedON DEPARTURE WX TERR WOULD NOT DISPLAY EITHER SIDE BOTH CAPT AND F/O RECYCLED AISLE STAND AND FWD PANEL SWITCHES APPROX 6 TIMES EACH ,THEN WX TERR AND TERR WAS DISPLAYED. PERFORMED WXR BITE PROCEDURES IAW FIM 34-43-FT 805. OPS CHECK NORMAL WXR SWITCH ON THE LE
Back to Boeing 767-3Y0