Boeing 767-3Y0
Service difficulty reports · 1,443
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018081701732Window · sparksDURING FLIGHT ENCOUNTERED ST ELMOS STATIC SPARKS ON FO WINDOW. WINDOW INSP AND OPS CK GOOD PER AMM 56-11-02.SDR UIEA2018081501696Warning System · false activationLEFT BLEED OFF EICAS MESSAGE ON DESCENT. C/W TASK 36-10 FAULT TREE 836 BLEED AIR VALVE OFF LIGHT ILLUMINATED WITH SWITCH ON DUCT PRESSURE NORMAL. OPS CHECK GOOD.SDR UIEA2018082001749Sensor · faultedAFTER APU START NO DUCT PRESS. CONFIRMED APU ISO VALVE OPEN AND PNEU ISO VALVE OPEN, PERFORMED BITE TEST ON APU ECU, FOUND P/T SENSOR FAULT ON LAST RUN, CLEARED. RESTART APU PNEUMATICS, OPS TEST NORMAL AS PER AMM 49-11-01.SDR UIEA2018081401686Indication Sys · malfunctionedEICAS MSG RT FWD FUEL PUMP WITH LEFT FUEL QTY INDICATING 2500 LOW ERRORS SELF CORRECTED AFTER 2 MINUTES. PERFORMED OPS CHECK OF FUEL BOOST PUMP IAW AMM 28-22-03. OPS CK NORMAL. PERFORMED BITE AND OPS CHECK OF FUEL QTY INDICATING SYSTEM NO FAULTS.SDR UIEA2018081101656Warning System · false activationON DEPARTURE FO WX RADAR INDICATED FAIL USING L SYSTEM, AFTER CYCLING WX SELECTOR, WX RADAR WORKED WITH NO FURTHER ISSUES. PERFORMED WXR BITE TEST IAW AMM 34-43-00.SDR UIEA2018081101657Unknown · malfunctionedLEFT FWD FUEL PUMP AUTO FUNCTION INOP. PERFORMED OPS CHECK FUNCTION IAW AMM 28-25-00.SDR UIEA2018080701635Warning System · false activationSTATUS MESSAGE CABIN ALT AUTO 2 AND CABIN ALT AUTO 1 AFTER LANDING. PERFORMED FIM TASK 21-31 FAULT TREE 803, NO DEFECTS. OPS CK GOOD.SDR P5CA2018080760177Warning Message · false activationRIGHT FWD WINDOW EICAS MESSAGE. RESET THE RT FWD WINDOW, OPS CHECKED NORMAL IAW AMM 30-41-01. SYSTEM OK.SDR P5CA2018080760176Controller · malfunctionedRIGHT FWD WINDOW WARNING ILLUMINATED AFTER LANDING. COMPLIED WITH AP-14378, CHECKED RESISTANCE AT D2898B PINS 4 AND 5. 10.5 OHMS. CHECKED RESISTANCE AT D2898A PINS 19 AND 20. 318 OHMS AT 80 DEG F. REPLACED THE WINDOW CONTROLLER M192 IAW AMM 30-41-01. OPSDR P5CA2018080300175Warning System · false activationEICAS MSG "RT FWD WINDOW". CYCLED CIRCUIT BRAKER IAW AMM 20-60-01, C/W BITE CHECK IAW AMM 30-41-01. NO FAULTS NOTED. OK FOR SERVICE.SDR P5CA2018073100172Warning System · false activationEICAS RT FWD WINDOW. OPERATIONAL TEST IAW AMM 30-41-00, OPS CHECK NORMAL.SDR UIEA2018073101593Module · faultyAPU AUTO SHUTDOWN AFTER BLOCKOUT. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-08. PERFORMED OPS CHECK OF APU AND RAN NR 1 ENGINE IAW AMM 71-00-00. NO DEFECTS NOTED. ENGINE RUN PERFORMED.SDR P5CA2018072600156Warning System · false activationRT WINDOW(HEAT) AMBER CAUTION MESSAGE AFTER LANDING. PERFORMED OPS CHECKS ON WINDOW HEAT SYSTEM IAW AMM 30-41-00 OPS CHECK GOOD AT THIS TIME. A/C OK FOR SERVICE.SDR P5CA2018072400144Unknown · malfunctionedRT FWD WINDOW HEAT INOP ON TAXI IN. PERFORMED OPS CK ON WINDOW HEAT SYS IAW AMM 30-41-00, OPS CKD GOOD.SDR P5CA2018072300140Status Message · false activationSTATUS MESSAGE AFT EQUIPMENT EXHAUST FAN. T/S IAW FIM 21-26 FT 805, OPS CHECK NORMAL NO FAULTS FOUND.SDR P5CA2018072300142Unknown · malfunctionedRT FWD WINDOW HEAT INOP ON TAXI IN. PREFORMED OPS CHECK ON WINDOW HEAT SYSTEM IAW AMM 30-41-00. OPS CHECK GOOD AT THIS TIME OK FOR SERVICE.SDR UIEA2018071201443Warning System · false activationRT FWD FUEL PUMP EICAS MESSAGE DISPLAYED FOR APPROX 60 SECONDS DURING INITIAL CLIMB. OPS CK FUEL SYSTEM IAW AMM 28-21-00. OPS GOOD.SDR P5CA2018072300131Apu · malfunctionedAPU FAULT DURING PUSHBACK/ENGINE START. INSTALLED AND TESTED SERVICEABLE APU IAW AMM REV 124 49-11-01 AND WORK CARD A-49-999-00-01. OPS CHECK GOOD.SDR UIEA2018071001424Module · malfunctionedAPU AUTO SHUTDOWN AFTER BLOCK OUT. REMOVED AND REPLACED FLOW SENSING MODULE IAW AMM 49-53-08. PERFORMED OPS CHECK OF APU AND RAN NR 1 ENGINE IAW AMM 71-00-00. NO DEFECTS NOTED. ENGINE RUN PERFORMED.SDR UIEA2018070901391Warning System · false activationRT FWD FUEL PUMP EICAS FOR SEVERAL MINUTES AFTER TAKE OFF. PERFORMED OPS CHECK ON RIGHT FWD FUEL BOOST PUMP IAW FIM 28-22 FT 820, NO FAULT FOUND AT THIS TIME.SDR P5CA2018070600110Warning System · false activation"RT FWD WINDOW" EICAS MESSAGE. CYCLED RT FWD WINDOW HEAT SWITCH AND PERFORMED WINDOW HEAT TEST IAW AMM 30-41-00. NO FAULTS NOTED AT THIS TIME.SDR UIEA2018070601361Warning System · false activationRT FWD FUEL PUMP EICAS MSG FOR SEVERAL MINUTES AFTER TAKE OFF. PERFORMED OPS CHECK ON RIGHT FWD FUEL BOOST PUMP PER FIM 28-22, FAULT TREE 820. NO FAULTS FOUND AT THIS TIME.SDR P5CA2018070500107Warning System · false activationRT FWD WINDOW EICAS MESSAGE DURING LANDING. CYCLED RT FWD WINDOW HEAT SWITCH, OPS CHECK GOOD IAW AMM 30-41-00 NO FAULTS NOTED AT THIS TIME.SDR UIEA2018070301325Unknown · malfunctionedON ARRIVAL, APU BLEED AIR VALVE WOULD NOT OPEN- NO DUCT PRESSURE. RECYCLED APU SWITCHES, DUCT PRESSURE NORMAL, NO DEFECTS NOTED AT THIS TIME IAW AMM 49-11-00.SDR P5CA2018070200106Warning System · false activationRT FWD WINDOW HEAT ILLUMINATED AFTER LANDING. PERFORMED BITE TEST R1 AND L1 WHCU NO FAULTS FOUND. CHECKED CONTINUITY AND SHORTED TO GROUND FROM R1 WINDOW TO WHCU VISUALLY INSPECTED THE WIRE BUNDLE AT RACK 4 E 2-1 AND T8 124. NO DEFECTS NOTED OPS CHECKED GOOD ISDR UIEA2018070101305Filter · cloggedAPU INOP. (DUE PNEUMATIC PRESS LOW). PERFORMED FIM 49-11 FT 979, FOUND DEBRIS IN LINE AND FILTER CLOGGED. R&R SURGE FILTER IAW AMM 49-53-06 OPS CHECK NORMAL.SDR P5CA2018070200104Controller · faultyRT FWD WINDOW HEAT INOP LIGHT ILLUMINATED UPON LANDING. REMOVED AND REPLACED WINDOW HEAT CONTROLLER FOR RT FWD AND LEFT SIDE PER AMM 30-40-01. OPS CHECKS GOOD.SDR UIEA2018062501237Ecu · malfunctionedAPU INOP. R&R APU ECU, PERFORMED APU BITE, NO DEFECTS NOTED AT THIS TIME AS PER AMM 49-61-05.SDR P5CA2018062200099Detector Loop · defectiveFWD CARGO DET 2 STATUS MSG DISPLAYED. REMOVED AND REPLACED NR 2 BLOWER IAW AMM 26-16-02. REMOVED AND REPLACED FWD CARGO DETECTOR LOOP 2 IAW AMM 26-16-01. OPS CK NORMAL.SDR UIEA2018060701054Control Panel · malfunctionedWEATHER RADAR ON BOTH THE CAPTAIN`S, AND FIRST OFFICER`S SIDES MUST BE CYCLED ON AND OFF SEVERAL TIMES BEFORE IT TURNS ON. REMOVED AND REPLACED THE WEATHER RADAR CONTROL PANEL IAW AMM 34-43-02, OPS CHECKED GOOD.SDR UIEA2018060701053Warning Message · false activationRIGHT A/C PACK TEMP MESSAGE AT FL 390, LIGHT EXTINGUISHES WITH SWITCH IN THE STBY N POSITION. OPS CHECKED THE RT PACK TEMP IAW AMM 21-60-00, NO DEFECTS NOTED. OPS CHECKED GOOD.SDR P5CA2018060700089Pad · looseRIGHT ENGINE ISOLATION PAD LOOSE. RE INSTALLED ATTACHED ENGINE ISOLATION PAD PER SP. OK FOR SERVICE.SDR UIEA201806051030Apu · unknownAPU WILL NOT START. PERFORMED TWO APU STARTS IAW AMM 49-11-00, BOTH STARTS SUCCESSFUL ,SDR P5CA2018053029080Warning Message · false activationRIGHT FWD WINDOW EICAS AFTER LANDING. INSPECTED THE WINDOW IAW AMM 56-11-01. FOUND NO ABNORMALITY. OPS CHECKED NORMAL.SDR UIEA2018052900993Unknown · malfunctionedWEATHER RADAR DOES NOT DISPLAY ON CAPTAINS MFD. PERFORMED OPERATIONAL CHECK ON WEATHER RADAR SYSTEM IAW AMM 34-43-00. OPS CHECK GOOD AT THIS TIME.SDR UIEA2018052500955Fire Detector · inoperativeMAIN CARGO FIRE LOOP A DECTECTOR NR 4 INOPERATIVE. REPLACED THE FIRE DETECTOR IAW AMM 26-19-01. CHECKED GOOD.SDR UIEA2018051870910Fire Detector · false activationMAIN DECK FIRE DETECTOR LOOP A STATION 2 IS AMBER. PERFORMED AN OPS CHECK OF THE MAIN CARGO FIRE DETECT IAW AMM 26-11-01, NO ISSUES NOTED. OPS CHECKED GOOD,SDR UIEA2018051870908Control Panel · malfunctionedDURING A TRANSIT CHECK, FOUND THE ENG/APU, CARGO TEST FIRE SWITCH STICKING, MASTER WARNING, CAUTION LIGHTS NOT WORKING. REMOVED & REPLACED THE FIRE - OVERHEAT TEST PANEL & THE FIRST OFFICER`S MASTER CAUTION WARNING SWITCH ASSY IAW SWPM 20-84-15, AMM 31-5SDR UIEA2018041900744Display · malfunctionedWEATHER RADAR DISPLAY HAS TENDENCY TO SPOKE AT ABOUT 3O DEGREES RIGHT IN BOTH LT & RT SYSTEMS. OPS CHECKED THE WEATHER RADAR DISPLAY IAW AMM 34-43-00 , UNABLE TO DUPLICATE SPOKE ISSUE , FUNCTIONAL TESTED OK.SDR UIEA2018041500705Radar · malfunctionedLEFT RADAR DOES NOT PAINT WEATHER. PERFORMED AN OPS CHECK IAW AMM 34-43-00.SDR P5CA2018041600060Warning Message · false activationBATTERY CHARGER STATUS INDICATED. COMPLETED FIM 24-31 FT 003 SYSTEM TEST. TESTED OK.SDR UIEA2018040700629Radar · malfunctionedFIRST OFFICER`S WEATHER RADAR WOULD NOT DISPLAY ON HSI. PERFORMED AN OPS TEST OF THE WEATHER RADAR SYSTEM , OPS CHECKED GOOD IAW AMM 34-43-00.SDR UIEA2018040300524Circuit Card · failedFWD EQUIPMENT EXHAUST FAN NR 2 STATUS MESSAGE. R & R THE EXHAUST FAN CIRCUIT CARD IAW AMM 20-10-01, OPS CHECKED GOOD.SDR UIEA2018032700464Circuit Card · malfunctionedAFT EQUIPMENT EXHAUST FAN NR 2 MESSAGE. RACKED THE NR 2 AFT EQUIPMENT EXHAUST FAN CONTROL CARD IAW FIM 21-26-808, OPS CHECKED GOOD. MESSAGE CLEARED.SDR UIEA2018032500460Pump · failedEICAS RT AFT FUEL PUMP MESSAGE. REMOVED AND REPLACED RIGHT AFT BOOST PUMP ASSY IAW AMM 28-22-03. OPS CHECKED NORMAL IAW AMM 28-22-00.SDR UIEA2018032500461Pressure Switch · failedLEFT FWD FUEL PUMP EICAS MESSAGE. REMOVED AND REPLACED THE LT FWD PRESSURE SWITCH IAW AMM 28-42-01, LEAK AND OPS CHECKED GOOD.SDR UIEA2018032400455Fan · inoperativeAFT EQUIPTMENT COOLING FAN INOPERATIVE IN AUTO. REMOVED AND REPLACED AFT EQUIPMENT COOLING FAN IAW AMM 21-26-01. OPS CHECKED GOOD.SDR P5CA2018031900050Seal Depressor · damagedRAMP CREW REPORTED MAIN CARGO DECK LWR FWD AFT SEAL DEPRESSOR PUSHED IN. REWORKED MAIN CARGO DOOR LWR FWD AND LWR AFT SEAL DEPRESSOR AS REQUIRED PER SRM 53-00-15-1A.SDR UIEA2018031400400Circuit Breaker · trippedTHREE HOURS INTO FLIGHT, WITH 30K LBS OF FUEL IN THE RIGHT TANK, RT TANK AFT RIGHT FUEL PUMP CIRCUIT BREAKER TRIPPED. IAW FIM 28-22 F/T 820, NO SIGNS OF FUEL LEAKAGE OR ANY ELECTRICAL DAMAGED NOTED. IAW FIM 28-22 F/T 820, BLOCK 5, SHEET 3. PERFORMED A BOSDR P5CA2018030100045Warning Message · intermittentRIGHT ENGINE EEC C1 MESSAGE. PERFORMED EICAS SYSTEM BITE CHECK AND CIRCUIT BREAKER RESET FOR THE RT ENG EEC C1 MESSAGE. NO MESSAGE FOUND AND PERFORMED ENGINE RUN IAW 71-00-00, ALL SYSTEM OPS CHECKED NORMAL.
Back to Boeing 767-3Y0