Boeing 767-3Y0
Service difficulty reports · 1,443
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7673Y0' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2014112100602Warning System · false activationSTATUS MSG ON DESCENT CABIN ALT AUTO 2. ACCOMPLISHED FIM 21-31 FT 803. TESTED OK NO FAULTS.SDR UIEA2014111700596Warning System · false activationON CLIMB EICAS ADVISORY LT ENG PRV STATUS MSG. CLEARED STATUS & OPERATIONS CHECKED IAW AMM 36-11-18 413-415. OPERATIONS CHECKED OK.SDR UIEA2014111300594Warning System · false activationRIGHT ENG PRV STATUS MSG ON ENG START. DURING DDG DEACTIVATION PROCEDURE, MSG EXTINGUISHED, REACTIVATED PRV & ACCOMPLISHED OPERATIONS. CHECKED IAW AMM 36-11-18 413 F - G PASS, MSG DID NOT RECUR.SDR UIEA2014102300503Warning System · activatedIDG OUT TEMP MX MSG. IN WORK ACFT IS IN A CHECK.SDR UIEA2014101800496Clamp · looseAPU BLEED AIR LOW 15 PSI. TIGHTENED CLAMP ON SURGE VLV.SDR UIEA2014101800499Tru · faultyAPU FAULT ON START AFTER LANDING. APU TRU DEACTIVATED. REPLACED APU STARTING TRU. TESTED IAW AMM 24-32-04 401. TESTED OK, ACFT RESTORED TO NORMAL CONFIGURATION.SDR UIEA2014101700492Control Valve · malfunctionedRIGHT PACK INOPERATIVE LIGHT. REPLACED PACK TEMP CONTROL VLV.SDR UIEA2014101300490Fuel Filter · faultedSTATUS MSG DISPLAY RT ENG FUEL FILTER. R & R RT ENG FUEL FILTER IAW MM 73-11-02 601. OPERATIONS CHECKED NORMAL.SDR UIEA2014101300491Light · out of positionRIGHT EMER LIGHTS FROM K5 TO K10 NOT ILLUMINATING DURING TEST. REPOSITIONED K10 LIGHT ASSEMBLY IAW 33-51-16. OPERATIONS CHECKED NORMAL.SDR UIEA2014100600477Fire Loop · faultyAPU FIRE LP 1 EICAS STATUS MSG NOTED UPON LANDING. R & R APU UPPER FIRE LOOP IAW MM 26-15-02. OPERATIONS CHECKED OK.SDR UIEA2014100600472Fire Warning · false activationAPU FIRE LP1 MSG CAME ON. PERFORMED OPERATIONS CHECK IAW AMM 26-15-00, NO FURTHER MSGS.SDR UIEA2014100300469Warning System · false activationRIGHT ENG CONTROL STATUS MSG. PERFORMED FIM 73-21 FT 878, BITE PIMU IAW 71-01 FT 810. MSG CLEARED. PERFORMED OHMS CHECK OF ECU P 7 & 8, CHECKED WITHIN LIMITS. PERFORMED GND TEST & ENG RUN, NO FAULT NOTED.SDR UIEA2014091500440Window · crackedCAPTAINS FWD WINDOW SHATTERED & CRACKED DURING CRUISE. R & R CABIN L1 WINDOW IAW AMM 56-11-01 & 30-41-00. OPERATIONS CHECKED NORMAL.SDR UIEA2014092000450Warning System · false activationSTATUS MSG R ENG PRV. ACCOMPLISHED ENG RUN ERASED STATUS MSG. PNEUMATICS TESTED OK IAW AMM 36-11-00/501, NO MSGS GENERATED. ACCOMPLISHED FIM 36-20 FT 804 FIG 104. VERIFY TEST, NO FAULTS PRESENT.SDR UIEA2014081300399Circuit Card · faultyAPU FIRE LP 1. R & R APU FIRE WARNING CONTROL CARD IAW AMM 26-15-00. OPERATIONS CHECKS COMPLIED WITH.SDR UIEA2014080500361Light · inoperativeFLOOR LIGHTS BETWEEN DOOR L1 & SEAT 2AC INOPERATIVE. EMER PATHWAY LIGHTING. REPAIRED IAW AMM 33-51-10-93.SDR UIEA2014080500353Light · inoperativeLEFT MID SLIDE LIGHT INOPERATIVE. REPLACED LT MID SLIDE BULB IAW AMM 33-51-06-902-082. OPERATIONS CHECKED GOOD IAW AMM 33-51-06-862-083.SDR UIEA2014080500354Wire · brokenFLOOR EMER LIGHT BETWEEN DOORS L1 & R1 INOPERATIVE. REPAIRED BROKEN WIRES IAW AMM 33-51-10.SDR UIEA2014080500355Gasket · unknownAPU IGNITER PLUG REQUIRES NEW GASKET. REPLACED APU IGNITER PLUG GASKET WITH NEW GASKET IAW AMM 49-41-02.SDR UIEA2014072500347Idg · inoperativeRIGHT GEN INOPERATIVE. TRANSFERRED TO DMI 49937. R & R RT IDG IAW AMM 24-11-01. OPERATIONS CHECKED & LEAK CHECKED IAW AMM 24-11-00, MEL CLEARED.SDR UIEA2014072300340Gcu · failedRIGHT GENERATOR DRIVE EICAS MESSAGE. ACCOMPLISHED RT GENERATOR DRIVE QRH PROCEDURE. RAN RT ENGINE IDG FREQS ARE 392 GEN CONTINUED TO DISCONNECT. REMOVED AND REPLACED GENERATOR CONTROL UNIT IAW AMM 24-22-02, OPS CHECKED OK.SDR UIEA2014071300326Heater · crackedRIGHT PACK OVERHEAT, REHEATER CRACKED. R & R PACK REHEATER IAW MM 21-51-07, OPS CHECKED OK.SDR UIEA2014070500315Warning System · false activationRIGHT BLD DUCT LEAK, EICAS MSG. PERFORMED OPERATIONAL CHECK OF WING & BODY DUCT LEAK DETECTION IAW MM 26-18-00, OPERATES NORMAL, NO DEFECTS NOTED.SDR UIEA2014070200309Smoke Detector · false activationSMOKE DETECTOR ON LAVATORY A3 ACROSS FROM THE L4 JUMP SEAT ACTIVATES INTERMITTENT IN FLIGHT. R & R SMOKE DETECTOR IAW MM 26-13-01, OPS NORMAL.SDR UIEA2014062900252Ecu · failedAPU BLEED INOPERATIVE. R & R APU ECU IAW MM 49-61-05. OPS CHECKED NORMAL.SDR UIEA2014061800237Door · damagedVIBRATION & RT PACK OVERHEAT EICAS MESSAGE. PASSING 10,000 FT & ACCELERATING. DIVERTED AND LANDED. INSPECTED ACFT & FOUND DUE TO IMPROPER DOOR PROCEDURES, BOTH PACK BAY ACCESS DOORS DAMAGED WITH ASSOCIATED HARDWARE & WIRING DAMAGED. PERFORMED REPAIR OF WISDR UIEA2014051900210Slide · low pressureR1 DOOR SLIDE REQUIRES REPLACEMENT FOR LOW PRESS. R & R ENTRY SERVICE DOOR ESCAPE SLIDE PACK AT R1 DOOR IAW AMM 25-66-01.SDR UIEA2014051900209Elt · damagedELT BEHIND SEAT 37CA ANTENNA STRING IS BROKEN & UNRAVELED. INSTALLED NEW ELT BEHIND SEAT 37CA IAW AMM 25-63-00, 25-05-03.SDR UIEA2014051900208Plenum · delaminatedLEFT PACK RAM AIR EXIT HAS DELAMINATION IN DUCT. REMOVED & REINSTALLED LT PACK EXHAUST PLENUM IAW AMM 21-51-03. REPAIRED PLENUM IAW SRM 51-70-06, LEAK CHECKED GOOD.SDR UIEA2014051900207Clamp · brokenENG 2 D SUMP RETURN OIL LINE CLAMP IS BROKEN AT APPROX 7 O`CLOCK POSITION ABOVE THE LOWER RECOUP DUCT. R & R CLAMP AT 7 O`CLOCK POSITION ON D SUMP RETURN OIL LINE IAW AMM 20-11-00.SDR UIEA2014051900206Light · inoperativeFLOOR EMERGENCY LIGHTS INOPERATIVE RT SIDE ROWS 26 - 30. REPLACED FLOOR EMERGENCY PATH LIGHTS AT ROWS 26 - 30 IAW AMM 33-51-10, OPERATIONS CHECKED SATISFACTORY.SDR UIEA2014051900205Carbon Seal · leakingRIGHT ENG CONSUMES MORE OIL THAN LT ENG. D SUMP AREA SUSPECTED TO BE AT FAULT. R & R SEALS AT D SUMP & STARTED CARBON SEALS. NO LEAKS NOTED AFTER ENG RUN IAW AMM 71-00-00.SDR UIEA2014051900204Window · damagedFL 41 BIRD STRIKE L1 OUTER PANE. R & R L1 WINDOW IAW AMM 56-11-01.SDR UIEA2014051900211Slide · low pressureL4 DOOR SLIDE REQUIRES REPLACEMENT FOR LOW PRESS. R & R ENTRY SERVICE DOOR ESCAPE SLIDE PACK IAW AMM 25-66-01 AT L4 DOOR POSITION.SDR UIEA2014051700196Seal · damagedRIGHT ENG CONSUMES MORE OIL THAN LT ENG & D SUMP AREA SUSPECTED TO BE AT FAULT. R & R D SUMP SEAL. R & R STARTER CARBON SEAL IAW AMM & EO 2016 2, NO LEAKS NOTED AFTER GND TEST IDLE.SDR UIEA2014051700198Connector · dirtySTATUS MSG APU LP 1 DISPLAYS INTERMITTENTLY. PERFORMED TROUBLESHOOTING. CLEANED & INSPECTED CONNECTORS, RECONNECTED IAW AMM 26-15-02, FIM 26-15-00, FAULT TREE 803 & SWPM 20-60-01. NO FAULTS PRESENT AT THIS TIME.SDR UIEA2014051700197Relay · defectiveAPU BLEED INOPERATIVE. TRANSFERRED TO MDDR 48227, DEFERRED IAW DDPG 49-11-01-01 CAT C PLACARD. R & R RELAY K23 AT PANEL P49 IAW SWPM 20-81-22. OPERATIONS CHECKED OF APU SOV GOOD IAW AMM 36-11-10. THIS CLEARS MDDR 48227, MCC NOTIFIED & PLACARD REMOVED.SDR UIEA2014051200176Bleed Air Sys · inoperativeAPU BLEED INOPERATIVE.SDR UIEA2014042800158Valve · malfunctionedAPU AIR INOPERATIVE. R & R APU SHUTOFF VLV IAW AMM 36-11-10, VLV CHECKED GOOD. FOUND LEAKING AIR DUCT IAW AMM 36-11-02. APU DUCT OPERATIONS CHECKED GOOD.SDR UIEA2014042600157Status Message · intermittentINTERMITTENT STATUS MSG, APU FIRE LOOP 1, IN FLIGHT. OPERATIONS CHECKED IAW MM 26-15-00, NO DEFECTS NOTED AT THIS TIME.SDR UIEA2014042200156Switch · faultyLEFT AFT FUEL PUMP WON’T TURN OFF. REPLACED BOOST PUMP LT AFT SWITCH, IAW SWPM 20-84-14. OPERATIONS CHECKED IAW AMM 28-22-03, MDDR CLEARED.SDR UIEA2014041600149Battery · faultySTATUS MSG APU BATTERY CHARGER. PERFORMED TROUBLESHOOTING IAW FIM 24-31-805. FOUND APU BATTERY FAULTY, REPLACED IAW AMM 24-31-04. SYS OPERATIONS & GND CHECKED GOOD.SDR UIEA2014040700139Fire Loop · false activationAPU FIRE LOOP ONE STATUS MSG. PERFORMED FIM PROCEDURE 26-15-FAULT TREE 804 & ALL INDICATIONS NORMAL.SDR UIEA2014033100134Fire Warning · false activationSTATUS MESSAGE, APU FIRE LP 1. PERFORM FIM PROCEDURE 26-15 FAULT TREE 804, ALL INDICATIONS NORMAL.SDR UIEA2014032100124Warning System · false activationRUDDER RATIO EICAS MSG, RUDDER RATIO LIGHT ON TAXI OUT. RE RACKED LT & RT RUDDER RATIO BOX, CHECKED TEST SWITCH POSITION, SYS OPERATIONS CHECKED NORMAL IAW FIM 27-21, FAULT TREE 804 & 27-09-00 101, CAT II/III.SDR UIEA2014031400104Unknown · malfunctionedNON-COMMANDED AILERON INPUT, NON-COMMANDED RT AUTOPILOT ENGAGEMENT, NON-COMMANDED VS ENGAGEMENT, NON-COMMANDED HEADING HOLD & NON-COMMANDED STAB TRIM RUNAWAY FULL NOSE UP. FOUND FAULT INDICATION ON RT AILERON STAB TRIM MOSUDE, RESET & ALL INDICATIONS RETURNEDSDR UIEA2014031400105Fire Loop · faultyRT ENG FIRE LOOP 1 DISPLAYED ON STATUS PAGE. R & R LOOP 1 DETECTOR ELEMENT, OPERATIONS CHECKED OK.SDR UIEA2014031200103Acm · seizedLEFT PACK AUTO MODE INOPERATIVE. TROUBLE SHOT IAW FIM, FOUND ACM TURBINE SHAFT SEIZED. REPLACED ACM WITH REPAIRED UNIT IAW AMM 21-51-03. LEAK & GND OPERATIONS CHECKED GOOD, PLACARD REMOVED.SDR UIEA2014031000098Controller · failedRIGHT SIDE WINDOW EICAS MESSAGE. PERFORMED FIM 30-41-801803 WINDOW RESISTANCE 10.3 OHMS, WITHIN LIMITS. REPLACED CONTROLLER IAW AMM 30-41-01, BITE CHECKED GOOD, PLACARD REMOVED.SDR UIEA2014031000100Clamp · unsecureLEFT PACK OVERTEMP DURING GND OPERATION IN AUTO & STANDBY. ACCOMPLISHED FIM PROCEDURE 21 - 51 FAUL TREE 804, FOUND LOW LIMIT CONTROL VLV LEAKING, SECURED CLAMPS, MDDR 46801CLOSED.
Back to Boeing 767-3Y0