Boeing 767-424ER
Service difficulty reports · 1,159
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026070517538Battery Pack · inoperativeEMERGENCY FLOOR PROXIMITY LIGHTS OF THE SEATS 39DEF UNTIL 44DEF INOPERATIVE. REPLACED THE BATTERY PACK OF THE RIGHT SIDE WALL (SEAT 40 KL) IN AMM REFERENCE: TASK 33-51-07-022-005-001 AND WAS FOUND A ELECTRICAL CONECTOR P/N 4NS103-1 LOOSE UNDER THE SEAT 39E, COSDR CALA2026070617570Wire Harness · damagedEMERGENCY LIGHTS INOP FROM ROW 50 BACK INOP. INITIALLY WHEN TESTING PATH LIGHTS, NOTICED LIGHTS FROM 50FD WERE ON BUT DIM & PATH LIGHTS AFT GOT DIMMER. LIGHT AFT OF 52FD WERE COMPLETLY INOP. SUSPECT THE BATTERY PACK & POWER SUPPLY. USED GOOD PARTS TO TEST ISDR CALA2026063017440Skin · delaminatedDURING THE ACCOMPLISHMENT OF NR 3478075, A DELAMINATED AREA WAS FOUND ON THE RH SIDE OF THE RUDDER. IT WAS REMOVED THE FASTENERS AROUND THE DAMAGE AREA AND REMOVED DAMAGED OF THE RUDDER, PERFORMED I NSPECTON E APPROVED THE MATERIALS, PERFORMED PERMANENT REPAIRSDR CALA2026062917375Lamp · inoperativeDURING SAFA INSPECTION, REPORTED EMERGENCY LIGHT AT CEILING 21LK INOPERATIVE, CEILING AISLE EMERGENCY LAMP 21LK INOPERATIVE PER MEL 3351A. REPLACED THE LAMPS, CEILING AISLE EMER LAMP 21LK. REMAINED INOPERATIVE.SDR CALA2026061717159Handle · no discrepancyAFTER ARMING L2 DOOR, THE YELLOW ARMED TAB WAS BEHIND THE HANDLE. DISARMED DOOR THEN CYCLED THE DOOR HANDLE. AFTER SECOND ARMING THE ARMED TAB JUST CAME IN FRONT OF THE HANDLE. NOTICED THAT THE DOOR HANDLE HAD SOME LOOSNESS & PLAY IN THE CLOSED POSITION. CHESDR CALA2026060916944Hydraulic System · leakingSTRANGE ODOR IN CABIN NO FOUL ODOR PRESENT WHEN ARRIVED AT A/C. NOTED A SMALL HYDRAULIC LEAK STREAMING INTO LEFT PACK INLET. SEE PICTURE. CLEANED AREA AND INSPECTED. FOUND NO ACTIVE LEAKS AT THIS TIME. PERFORMED PACK BURN OUT. NO FOUL ODORS NOTED THROUGHOUT ENSDR CALA2026060916951Fcu · faultedWITH APU RUNNING EXHAUST FUMES ENTERING AIRCRAFT.DURING TRANSIT CHECK FOUND BIG FUEL LEAK FROM FCU APU , CHECKED WITH ALL MAIM FUEL PUMPS ON ,APU OFF NO MORE LEAKS NOTED ,FOR THAT REQUEST DISPATCH A/C IAW MEL 4911F MEL 4911F PLEASE APPLY 4911D AS PREVIOUSLY AGSDR CALA2026060816916Valve · stuckL1 LAVATORY CONTINUOUSLY FLUSHING FLUSH VALVE STUCK IN OPEN POSITION. MANUALLY CLOSED. WATER IS SHUT OFF. TOILET IS INOPERATIVE XFD IAW MEL 3830J. R & R LAV TOILET ASSEMBLY IAW AMM 38-32-01. OPS CHECK GOOD. LEAK CHECK GOOD. REMOVED INOP PLACARD FROM LAV. LAVSDR CALA2026060416830Light · inoperative30D SEAT-MOUNTED EMERGENCY ESCAPE PATH LIGHT DOES NOT COMES ON. REMOVED AND REPLACED 30D SEAT-MOUNTED EMERGENCY ESCAPE PATH LIGHT ASSEMBLY REF AMM TASK 33-51-10-962-104. OPS CHECK GOOD. ITEM OK FOR SVC.SDR CALA2026060116710Light · damagedEMERGENCY FLOOR LEVEL LIGHTING AFT GALLEY LOCATION 913 DAMAGED REPLACED WALL MOUNTED EMERGENCY LIGHT IN AFT GALLEY NEAR CART 913 AS PER AMM TASK 33-51-10-962-173. OPN CHECK GOOD. OK TO CONT.SDR CALA2026052616534Flap System · indicationTE FLAP DISAGREE FOLLOWED CHECKLIST PERFORMED FSEU BITE TEST PER FIM 27-51 FAULT TREE 809 FOUND MSG 27-81045. PERFORMED BITE TEST ON PSEU PER FIM TASK 32-09 FAULT TREE 803, FOUND FAULT CODE 297 FOR R SLAT #9 OUTB. FLAPS DO NOT MOVE UP IN NORMAL MODE RECONFIGURSDR CALA2026051516301Frame · crackedNR 1 PYLON NACELLE STRUT AFT TORQUE BOX INT (THROUGH #436AL) LH VERT FRAME FOUND CRACK AT NAC STA 285.45. NR 1 PYLON NACELLE STRUT NAC STA 285.45 LH VERTACLE FRAME REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02.SDR CALA2026051416227Light · detached49F EMERGENCY LIGHT IS HANGING BY WIRE, ITEM DEFERRED IAW MEL EMERGENCY LT AT SEAT 49F INOP. ITEM DEFERRED TOMC APPROVED INSTALL 49F EMERGENCY LIGHT SEAT ASSEMBLY.OPS CK GOOD.MEL REMOVED.OK TO CONTINUE.SDR CALA2026051216193Light · detachedEMERGENCY EXIT ROW LIGHT AT 54F HANGING BY WIRES . SECURED THE LIGHT ASSY IAW AMM 33-51-00-715-001. OPS CHECK GOOD.SDR CALA2026051116162Engine · vibrationFAN VIBRATION 4.1 AT CLB THRST TO FL270. AT CRUISE VIB IS 1.0. NO AIR FRM VIB FELT. OIL TEMP AND PRESS PER CREW DEBRIEF: ALL OTHER ENGINE INDICATIONS WERE NORMAL DUE TO PILOT REPORT OF VIBRATION NOT FELT IN FLIGHT DECK, PERFORMED FIM 77-31 FAULT TREE 808. SWISDR CALA2026050716049Unknown · odor2L OVRHEAD AIR VENT BLOWS RANCID SMELL INSPECTED. AREA OF 2L DOORWAY NO SMELL DETECTED.SPOKE TO F/A. SMELL SOME WHAT. DISAPPEARED.NO FURTHER ACTIONSDR CALA2026050415931Sleeve · damagedDURING WALKAROUND FOUND #2 ENG INB THRUST REVERSER SLEEVE LINER DAMAGED 11 O CLOCK POSITION.AREA OF TRIM OUT 1FT X 2FT AT 11 O'CLOCK POSITON. ACCOMPLISHED INTERIM REPAIR PART 1 OF ECRA 7831-01423 REV D. REINSPECTED #2 ENG INB THRUST REVERSER SLEEVE LINER 11 SDR CALA2026042715732Oven · failedFORWARD GALLEY OVEN 109 ODOR POSSIBLY ELECTRICAL. PRECAUTIONARY C-B PULLED OPEN GALLEY OVEN 109. GALLEY OVEN REPLACED IAW AMM 25-31-00SDR CALA2026042115572Antenna · failedDUAL WX RADAR FAIL WXR SYS STATUS MSG REPLACED CONTROL PANEL PRECAUTION. REMOVED AND REPLACED WEATHER RADAR SCANNER PEDESTAL ANTENNA, OPS CHECK GOOD REF AMM 34-43-05/401 CONFIG 1. COULD NOT DUPLICATE FAULT.SDR CALA2026042015522Light · damagedFLOOR EMERGENCY LIGHT BROKEN AT SEAT POSITION 30F, 38F, 39. REMOVED AND REPLACED THE LIGHT ASSY POSITION 30F, 38F, 39D. IAW AMM 33-51-10-962-104. ITEM GOOD FOR SERVICESDR CALA2026041915477Charger · inoperative47 TO 54 CENTER PROXIMITY EMERGENCY LIGHT INOPERATIVE. R & R BATTERY CHARGER, ITEM GOOD FOR SVC, IAW AMM 33-51-07-002-014-001.SDR CALA2026041715440Sensor · faultedRIGHT ENG ANALOG N2 STATUS MSG DISPLAYED DEBRIEFED CREW. CREW STATED AFTER TAKE OFF INTO CRUISE THEY NOTICED RIGHT ENG BLEED LIGHT OFF LIGHT ILLUMINATED. QRH WAS PERFORMED WITH NO HELP. SHORTLY AFTER RIGHT CTR FUEL PUMP LIGHT ILLUMINATED WITH NO OTHER ALERTS. SDR CALA2026041715438Pump · malfunctionedC HYD DEMAND PUMP EICAS W/FLAP RETRACTION TOMC HAS ORDERED PARTS TO IAD FOR FIM TASKS: ADP LOW PRESSURE LIGHT IS ON IN AUTO MODE OR MANUAL MODEREFERENCE: 29-11 FAULT TREE 898 FOLLOWED FIM TASK 29-11 FAULT TREE 898 PERFORMED CONTINUITY CHECK BETWEEN PIN 2 AND 3SDR CALA2026041515388Control Panel · odorELECTRICAL ODOR COMING FROM OVERHEAD ANNUN PANEL FLAGGED SDR AND FILLED IN REMOVED PART INFO UPDATED PART INFO FOR SDR REMOVED AND REPLACED OVERHEAD MISCELLANEOUS ANNUCIATOR PANEL PER CMM 33-16-52. ALL LIGHT TEST PASSED. PANEL SECURED. COMPLIED WITH SMOKE/ODORSDR CALA2026041515379Unknown · odorELECYRICAL BURNING ODOR IN THE COCKPIT CAN SMELL AT THE MAIN DO OR AIRCRAFT HAS BEEN ON THE GROUND 24 HOURS WITH NO AIRCONDITIONING HOOKED UP. TEMPERATURES TODAY WERE IN HIGHS 80F. STARTED APU WITH PACKS ON. NO ELECTRICAL ODOR. INSPECTED COCKPIT ALL DISPLAYS SDR CALA2026040715152Gcu · faultedRIGHT GEN CONT OFF LIGHT ILUMINATED. RESET, LIGHT EXTINGUISHED SOON AFTER RH BUS TIE ANUNCIATOR LIGHT CAME ON. CREW DID NOT ATTEMPT RESETOF RH BUS TIE.SDR DUE TO DECLARED IN-FLIGHT EMERGENCY CREW PHOTOS PART 1 BPCU BITE SHOWS : RIGHT GCU MONITOR "NO R GCU DATASDR CALA2026040615068Seal · leakingAPU LEAKING, SMELLS LIKE GAS IN AIRPLANE FOUND DEFECTIVE APU FUEL POWER UNIT LINE SEAL, R/R APU FUEL POWER UNIT SEALS PER IPC 49-31-00-02 ITEM 5,15,20. OPERATED APU NO LEAKS NOTED AT THIS TIME AND NO SMELL OF FUEL NOTED.SDR CALA2026040615084Light · inoperative49D AND 30D SEATS EMERGENCY FLOOR PROXIMITY LIGHTS ARE DAMAGED. REMOVED AND REPLACED LIGHT ASSY, ITEM GOOD FOR SVC, AMM 33-51-10-962-105.SDR CALA2026040615083Lens · missing30F AND 49D SEAT PROXIMITY EMERGENCY LIGHTS LENS MISSING REMOVED AND REPLACED LIGHT ASSY, ITEM GOOD FOR SVC, REF AMM 33-51-10-962-105.SDR CALA2026040114998Fuel Tank · leakingRIGHT FUEL TANK DRY BAY HAS RUNNING LEAK LABOR AND GROUND TIME UPDATED FUEL LEAK FOUND AT ETOPS CK SUSPECT FUEL LEAKING FROM FAILED SEAL LOCATED AT TOP CORNER OF RIGHT WS 344.3 INTO THE DRY BAY. PERFORMED FUEL TANK LEAK DETECTION BACKBLOWING PROCEDURE REF AMMSDR CALA2026033014920Paint · missingDURING INSPECTION FOUND MISSING PAINT ON NOSE RADOME. DURING PHASE 2 INSPECTION FOR LIGHTNING STRIKE. FOUND MISSING PAINT ON RADOME MEASURING APPROX. 1 SQ INCH. NO STRUCTURAL DAMAGE FOUND. APPLIED CLEAR TAPE TO EXPOSED AREA PER EC/RA 5350-02074. ACCOMPLISH ASDR CALA2026032014699Wire · damagedUPON INSTALLATION OF EE FORWARD CHILLER ADJACENT WIRE BUNDLE ARCHED FLAGGED SDR ON LOGPAGE. WIRE HARNESS BUNDLE DAMAGED BY CHILLER APPROXIMATELY BETWEEN STA 250 AND STA 287 AND RBL 50.00 AND RBL 75.00 IN EE BAY. DURING REPLACEMENT OF FORWARD CHILLER, CHILLER CSDR CALA2026031014457Oven · failedBURNING ODOR AND LIGHT SMOKE FROM GALLEY OVEN 109, DEBRIEFED WITH CREW, OVEN SMELLED LIKE CIGARETTES WHEN TURNED ON. REPLACED OVEN IAW AMM 25-34-00-020-801-C3. NO HELP, OVEN DOES NOT POWER.SDR CALA2026030914449Light · missingPRIXIMITY LIGHT POSITION 34F HAS NO LENS. REMOVED AND REPLACED ESCAPE PATH LIGHT SEAT MOUNTED LIGHT ASSEMBLY REF. AMM TASK 33-51-10-962-104 REV-. GOOD FOR SERVICE.SDR CALA2026030414303Bulb · inoperativeDURING SAFA INSPECTION CEILING EMER LIGHT AT ROW 7A INOP CEILING EMER LIGHT AT ROW 7A INOP IAW MEL 3351A INTERIOR EMERGENCY LIGHT SYSTEM HAS INOPERATIVE LIGHT CEILING EMER LIGHT AT ROW 7A INOP IAW MEL 3351A RELAMPED LIGHT NO HELP NEEDS FURTHER T/S. REMOVED AMSDR CALA2026030314269Lamp · inoperativeOUTER ESCAPE LIGHT LAMP FOR R4 DOOR INOPERATIVE. REMOVED AND REPLACED LAMP IAW AMM 33-51-06.SDR CALA2026030314267Lamp · inoperativeOUTER ESCAPE LIGHT LAMP FOR L4 DOOR INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-51-06.SDR CALA2026030314263Gcu · faultedAFTER ENGINE START THE L GEN EICAS ILLUMINATED RAN CHECKLIST AND RESET L GEN SUCESSFULLY REMOVED AND REPLACED BOTH L GCU & BPCU REF AMM 24-22-02 & FIM 24-20-04. NO FAULTS FOUND AND OPS CHECK GOOD AFTER ENGINE RUN.SDR CALA2026030214175Lens · damagedSEAT 50F FLOOR PROXIMITY LIGHT LENS DAMAGED. REMOVED AND REPLACED LIGHT ASSY, ITEM GOOD FOR SVC, REF DWG 3351DD16252.SDR CALA2026030514369Skin Panel · damagedLEFT SKIN BTW BS 654+88 - 654+110, S29L-30L CREASED. THERE ARE NO ALLOWABLE LIMITS FOR THE CREASE IAW SRM 53-00-01-1A-1, PERFORMED A REPAIR IAW ECRA 5330-07699, PART 1 INTERIM REPAIR WITHOUT ANY DEVIATION.SDR CALA2026030214210Door · inflt separationLEFT RAM AIR INLET DOOR ASSY FWD PIECE DEPARTED A/C. COMPOSITE PIECE MORE 15 SQUARE INCHES BUT NOT MORE THAN 150 SQUARE INCHES. PART IS ROUGHLY 17 INCH X 12 INCH.SDR CALA2026031714621Skin · dentedSECTION 46 AT LOWER SKIN BETWEEN STA 1439 / STA1461 AND STR 38R HAS DENT & CREASE CREATED THE SFR AND IT IS NECESSARY TO QC CHECK AND APPROVAL THE SFR THE SFR #3048 WAS REVIEWED BY QC. DENT/CREASE IN THE FUSELAGE SKIN BETWEEN STA 1439/1461 AND STGR - 38R WAS RSDR CALA2026030314279Aileron · damagedIT WILL BE NECESSARY TO REPAIR THE OUTBOARD AILERON LH AS PER AMM TASK 03-57-60-280-801 PARAGRAPH 2.F(7)(A). CREATED SFR, IT IS NECESSARY QC CHECK AND APPROVAL. ESFR #3049 WAS CHECKED AND APPROVED BY QC. ALL STEPS OF THE ECRA 5760-01139 WERE EXECUTED WITHOUT DSDR CALA2026030314265Aileron · damagedIT WILL BE NECESSARY TO REPAIR THE RT OTBD AILERON IAW AMM TASK 03-57-60-280-801, PARAGRAPH 2.F(7)(A). PROVIDE DETAILS ABOUT THE REPAIR ACTIONS IT WAS ACCOMPLISHED THERMOGRAPHY INSPECTION ON RT OTBD AILERON IAW NDT MANUAL PART 9 51-00-01. AFTER DAMAGE REMOVALSDR CALA2026022414036Lens · missing35D AND 38D PROXIMITY LIGHT LENS MISSING INSTALLED LENSES, ITEM GOOD FOR SVC, REF DWG 3351DD16252 PARTS USED: 29-3326-3-0013,QTY :2SDR CALA2026022013939Guard · brokenEMERGENCY LIGHT SWITCH COVER BROKEN, FOUND EMERGENCY LIGHT TOGGLE SWITCH GUARD AT P5 PANEL WITH METAL LEVER LOOSE. REPOSITIONED IT AND PERFORMED TEST AS PER AMM 33-51-00-715-001. GOOD FOR SERVICE.SDR CALA2026021813894Power Supply · inoperativeEMERGENCY LIGHTS, AISLE 30 - 37 INOPERATIVE. REMOVED AND REPLACED THE POWER SUPPLY M732 IAW AMM 33-51-07-002-014-001, AND AMM 33-51-07-402-018-001. CHECKED OK.SDR CALA2026021013647Packing · leakingPUDDLE OF LIQUID UNDERNEATH APU. LIQUID APPEARS TO BE DRIPPING FROM APU. UPON INSPECTION OF APU, FOUND APU RETURN TUBE FOR THE IGV ACTUATOR AND SURGE CONTROL VALVE LEAKING . R & R PACKINGS IAW AMM 49-31-01. OPS & LEAK CHKD GOOD. NO FUEL ODORS NOTED.SDR CALA2026020613622Controller · faultedON DESCENT, RECIEVED LT & RT PACK OFF LIGHT. ATTEMPT TO RESET FAILED. DESCENDED TO 9000 FT, DEBRIEF FROM PILOTS . DURING OCCURANCE, RT COND TEMP CONT & R SEC HX SENSOR DISPLAYED AT TOC FL320, ACCOMP SYS TEST ON RT CTC.. TEST PASSED. RT RAM INLET ACTUATOR SDR CALA2026020513599Valve · inoperativeNO POTABLE WATER. LAV MOTOR WORKING WITH NO WATER. WATER GAUGE SHOWS FULL. RTB EWR IF AIR IS COMING OUT FROM AFT OVERFLOW DRAIN PORT AT STA 1530, REPLACE VENT OVERFLOW VALVE V130 REF AMM 38-11-05-004-001 EWRMM WORKING ITEM REF LOGPAGE 7804209. INSPECTED PRES
Back to Boeing 767-424ER