Boeing 767-424ER
Service difficulty reports · 1,159
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767424ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025082108009Skin · crackedDURING INSPECTION AT RIGHT WING OTBD SLAT NR 11 FOUND CRACKED ON SKIN INBD NEAR ACCESS PANEL 625AT. PERFORMED PERMANENT REPAIR IAW EC/RA 5743-02012.SDR CALA2025082107987Cover · damagedDOOR 2R SLIDE COVER DAMAGED. INSPECTED DOOR 2R SLIDE COVER AND SURROUNDING AREA. COULD NOT FIND ANY DISCREPENSIES. REF AMM 25-66-00.SDR CALA2025081907934Window · leakingLOUD WIND NOISE OBSERVED AFTER TAKEOFF. GOT LOUDER WITH INCREAS ED AIRSPEED. AS REPORTED VERBAL BY FLT-CREW NOISE CAMING FROM THE NOSE FUSELA GE. PERFORMED RADOME INSPECTION ALL OK. PERFORMED FWD FUSELAGE I NSPECTION ALL OK. PERFORMED PIPE CONDITIONING IN THE SDR CALA2025081907933Transmitter · faultedLE FLAP ASYM EICAS ON FLAP RETRACTION 1 TO UP WHEN A/C ARRIVED AT GATE, NO MSG PRESENT. CREW SAYS EICAS MSG WA S INTERMITTENT. ON BIT TEST OF FSEU, FOUND FAULT CODE 27-81021, LE OTBD ASYM IN FAULT HISTORY. VISUALLY INSPECTED & CLEANED PROX SENSORS M276 & M297 SDR CALA2025082208056Control Unit · faultedRTO DUE TO LEFT ENG SURGE AND STALLDEBRIEF FROM CREW PUSHING THROTTLES UP TO 70% N1 LH ENG SLOW TO ACCELERATE. ENGAGED AUTO THROTTLE AND ENGINE SPOOLED UP AND THENN1 ROLLED BACK TWICE TO 90% N1. F/O MAY HAVE SEEN EXCEEDANCE BUT NO RED BOX SHOWING. CREW HAD NO SDR CALA2025081407732Packing · leakingODOR IN CABIN DURING APU VISUAL INSPECTION, FOUND APU FCU LEAKING FUEL AT IGV ACTUATOR LINES ON FCU SIDE, R & R FUEL DRAIN, RETURN TUBE & TWO SUPPLY TUBE PACKINGS TO FCU IAW AMM 49-31-01-004-001-001. OPS & LEAK CHECKS PERFORMED. NO LEAKS NOTED. PERFORMED CHECSDR CALA2025081307684Light · inoperativeFOUND LEFT BS 654 EMERGENCY OVERWING ESCAPE LIGHT INOPERATIVE. R & R LT BS 654 EMERGENCY OVERWING ESCAPE LIGHT IAW AMM 33-51-06. OPS CHECKED GOOD.SDR CALA2025081407731Strobe · faultedLOWER RED ANTI-COLLISION LIGHT HAS BEEN DEFERRED IN COMPLIANCE WITH CDL CARD 334430 REF LOG PAGE 5883456 APPLIED MEL 3344AD, BOTH (LEFT AND RIGHT) WING TIP WHITE, TAIL CONE WHITE STROBE LIGHTS AND UPPER RED ANTI-COLLISION OPERATE NORMALLY , ALL POSITION LIGHTSSDR CALA2025081307674Warning Light · false activationLFT AFT MAIN DOOR EICAS MSG CAME ON ON TOCHDOWN EMERGENCY LIGHTS TURNED ON IN THE CABIN CHECKED AFT LH ENTRY DOOR, CLOSED AND REOPEN SEVERAL TIMES. VERIFY WITH CREW MESSAGE DID NOT APPEAR. CLEAN SENSOR.SDR CALA2025081107547Warning Light · false activationRIGHT ENGINE BLEED OFF LIGHT THRU 10000. CLB PWR AND TAT +20. ASSOCIATED, OFF.DISCONNECTED CONNECTORS FROM N2 SPEED SENSOR ON NR 2 ENGINE IAW AMM 77-12-02, REMOVED LT & RT DCU IAW AMM. 31-63-06, DISCONNECTED CONNECTORS D5552P & D8032P. JUMPED PINS 3 & 4 ON P7SDR CALA2025080807495Light · brokenSEATS 39D AND 40D WITH ESCAPE PATH LIGHTS BROKEN. CONFIRMED. REPLACED ESCAPE PATH LIGHT OF THE SEATS 39D AND 40D, IN REF AMM 33-51-10-962-104 ITEM OKAY FOR SERVICE.SDR CALA2025080807517Thrust Reverser · damagedFOUND HOLE ON #2 ENGINE OUTBOARD TR MEASURING 10X11 IN. ESTIMATED TO BE LESS THAN 2.2 LBS BUT GREATER THAN 3.5OZ OF MATERIAL LOSS.DAMAGE IS AROUND 2 OCLOCK POSITION ON TR HALF FLAGGED SDR IDT REQUIRED FOR DAMAGE VERFICATION PER MANAGEMENT REQUEST VERIFED DAMAGSDR CALA2025080507288O-Ring · deterioratedSIGNIFICANT FUEL SMELL THROUGHOUT CABIN WHILE DOING EXTERIOR WALKAROUND FOUND APU LEAKING FUEL. UPON FURTHER INSPECTION FOUND FUEL LINES GOING TO APU FUEL CONTROL LEAKING FUEL. REMOVED FUEL TUBES TO FUEL CONTROL UNIT. FOUND O-RINGS DETERIORATED. REPLACED O-RISDR CALA2025072806985Sensor · faultedR ENG BLEED OFF ICAS WIT BLEED OFF LIGHT ON OVERHEAD ADDED PICS OF ASCTU RT ENG FAULT HISTORY PER CREW DEBRIEF, BLEED OFF AND PACK OFF WAS INTERMITTENT. REF HISTORY OF R BLEED OFF ON LEVEL OFF AND DESCEND PERFORM FIM 36-10 FT913 ALONG WITH PNEUMATIC HEALTH CHESDR CALA2025072406877Lamp · inoperativeFOUND EMERGENCY LIGHT INOP AT OUTSIDE L1 DOOR. REMOVED AND REPLACED EMERGENCY LIGHT AT OUTSIDE L1 DOOR. REF AMM 33-51-06.SDR CALA2025072106797Pcb · faultedLOST AIR DRIVEN PUMP ON TAKE OFF-AIR PRESSURE LIGHT ON WITH SWITCH POSITION AT ON OR AUTO. PER CREW UPDATED ON TAKE OFF GEARS SELECTED HYDRAULICS PRESSURE WENT TO LOW , CREW FOLLOWED CHECKLIST FOR EICAS MESSAGES. ADP SWITCH AUTO TO ON PRESSURE LIGHT ON THE SDR CALA2025071106470Pca · failedNUMBER 12 SPOILER ACTUATOR LEAKING HYDRAULIC FLUID. INSPECTION FOUND NR 12 SPOILER PCA FAILED. NR 12 SPOILER PCA REMOVED AND REPLACED IAW AMM 27-61-02/401. OP TEST AND LEAK CHECK FOUND NO FURTHER DEFECT.SDR CALA2025072106741Idg · explodedLEFT GEN DRIVE EICAS C THE LT GEN DRIVE HAS LOW OIL PRESSURE OR HIGH OIL TEMPER ATURE WHILE THE ENGINE IS IN OPERATION. LT ENG. C-DUCT OPENING AS AMM 78-31-00 THE FOLLOWING DAMAG ES HAS BEEN OBSERVED AS X GENERAL OVERVIEW: IDG ASSY ALL IDG OI L HOSES APPEARINSDR CALA2025071006426Stringer · crackedDURING OPEN HOLE HFEC INSPECTION OF NR 2731310 WAS FOUND CRACK HOLE INDICATION AT STGR 39LH AND STA 1395 PERFORMED INSPECTION. PERFORMED PERMANENT REPAIR AT STRINGER S-39L BTW STA1395 AND STA1417 AS PER ECRA 5360-01975. PERMANENT REPAIR AT STRINGER S-39L BTW SDR CALA2025070806313Fuel Sys · leakingTOXIC FUMES IN CABIN. APU FUEL LEAK. RAN BOTH PACKS, INSPECTED THE CABIN AND PERFORMED INSPECTION IAW AMM 05-54-56. NO SIGN OF ODOR FUMES THROUGHOUT THE CABIN.SDR CALA2025070706241Battery Pack · dischargedEMERGENCY LIGHTS OPERATIONAL CHECK {B767-33-3-7000} - ALL EMERGENCY LIGHT FROM PREMIUM SEAT AISLE DOES NOT COMES ON PERFORMED WDM 33-51-11-901 FOUND M6758 AND M6759 EMER LTS POWER SUPPLY WITH LOW BATTERY CHARGE. REPLACED BATTERIES AS REF AMM 33-51-07-022-005-0SDR CALA2025070706236Switch · faultedOVERHEAD EMER LIGHTS UNA RMED LIGHT INOP FOUND EMERGENCY UNARMED LIGHT ANNUNCIATOR STUCK IN PLACE. PULLED OUT SLIGHTLY AND LIGHT CAME OUT IN PIECES. MOUNTING SLEEVE INTACT BUT NEW KORRY SWITCH REQUIRED. REMOVED AND REPLACED EMERGENCY LIGHT UNARMED ANNUNCIATOR SDR CALA2025062605883Cover · unsecureDOOR 2R SLIDE COVER NOT SEATED FLUSH WITH DOOR. DOOR ARMS AND IN DICATES LOCKED INSTALLED BUSTLE REF AMM SUBTASK 25-66-01-414-066. ITEM OKAYSDR CALA2025062305790Pressure Switch · faultedR ENG FUEL FILTER CAUTIO N AND STATUS MESSAGE INSPECTED FUEL FILTER WITH NO DEBRIS FOUND, REPLACED ENG 2 FUEL FILTER AND FUEL PRESS SWITCH REF AMM 73-11-02-404-008-H00 AND 73-34-01-424-008-H00. PERFORMED ENG 2 IDLE RUN REF AMM 71-00-00 WITH NO LEAKS NOTED ANDSDR CALA2025061905698Proximity Switch · damagedE/E ACCESS DOOR EICAS LIGHT ILLUMINATED ON T/O.. INTERMITTENT FLASHING. QRH FOLLOW D VISUALLY INSPECTED E/E DOOR SENSOR FOUND DAMAGE ON SENSOR. REQUESTING MEL FOR E/E DOOR SENSOR. APPROVED DDP COMPLIED, VERIFIED E/E DOOR CLOSED AND SECURED. CONFIRMED DAMAGE SDR CALA2025061105465Pca · leakingRIGHT HYD QTY LOW PER CREW DEBRIEF, APPEOX 2 HRS INTO FLT, HYD QTY STARTED TO DECREASE & NOT FLUCTUATE ON ARRIVAL QTY IND SHOWS .39 WITH BRAKES SET MATCHING HYD SERVICE PANAL GAUGE. ON ARRIVAL PERFORMED GVI OF RT MLG, WINGS, & BELLY OF A/C WITH NO NOTIABLE LEASDR CALA2025060905364Light · brokenEMERGENCY LIGHTS PROXIMITY LIGHT BROKEN AT POSITIONS 30F/32F/54D. REMOVED AND REPLACED THE EMERGENCY LIGHTS PROXIMITY LIGHT AS POSITIONS 30F/32F/54D AS REF AMM 33-51-10-962-105. ITEM GOOD FOR SERVICE. PARTS USED: 76-2525-3-0269, QTY :3SDR CALA2025060605322Slide · faultedEMERGENCY EXIT DOOR MOUNTED ESCAPE SLIDES REPLACE {B767-25-3-0032} - DOOR L3 S/N 0394 REMOVED AND REPLACED EMERGENCY EXIT DOOR MOUNTED SLIDE AT DOOR L3 IN REF WITH AMM 25-66-10. PARTS USED: 64-2566-9-0005, QTY :1 ROTABLE PARTS CHG:TT # 1567912 SN OFF 0394 PN SDR CALA2025060305209Warning Message · false activationACCESS DOOR E/E FWD EICAS ON DEPARTURE BETWEEN 6-10K FT. PRESSUR IZATION NORMAL. FAULT NOT PRESENT ON GROUND. FIM TASK 52-71 FAULT TREE 814 C/OUT AND NO FAULT FOUND. DOOR WARNING SENSOR TEST OF ELECTRONICS DOOR C/OUT SATISFACTORY IAW AMM TASK 52-71-00-735-072 SDR CALA2025060205177Pressure Switch · faultedINTERMITTENT RIGHT ENGINE FUEL FILTER BYPASS. REMOVED, INSPECTED AND REPLACED RIGHT ENGINE FUEL FILTER REF AMM 73-11-02. INSPECTION OF FILTER SHOWED CLEAN NO DEBRIS NOTED. REMOVED AND REPLACED FUEL FILTER DIFFERENTIAL PRESSURE SWITCH REF AMM 73-34-01. LEAK CHESDR CALA2025052905060Wire · severedR1 FORWARD ENTRY DOOR SENSOR WIRES FOUND SEVERED. REPAIRED WIRES W780-201R/B-24 AND W780-202R/B-24 TO R1 FOWARD ENTRY DOOR SENSORS S196 AND S197 REF SWPM 20-30-12 & WDM 52-71-11-1. PERFORMED DOOR WARNING SENSOR TEST FOR R1 DOOR AS PER AMM TASK 52-71-00-735-07SDR CALA2025051904757Heater · faultedFLT ATNDTS DETCTD SMOKE ODOR NEAR DOOR 2R. 2R DOOR HEATER WAS TU RNED OFF. TOMC ADVISED CREW REPORTEDLY TURNED OF DOOR 2R HEATER AND ODOR DISSIPATED. (MC) PERFORMED SMOKE/ODOR IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56-202-001-001 NO OTHER FAULTS NOTED. SDR CALA2025050904587Bleed Valve · faultedAFTER ADDING TAKEOFF POWER R ENG BLEED AND R PACK MESSAGE APPEA RED. REJECTED AT 85KTS. REQUEST APPROVAL TO DEFER RH HPSOV IAW MEL 3611BR. ENGINE HIGH PRESSURE SHUTOFF VALVE (HPSOV) INOPERATIVE SECURED CLOSED. ASSOCIATED THRUST REVERSER IS CONSIDERED INOPERASDR CALA2025050704514Light · unknownAFT RIGHT SERVICE DOOR EMERGENCY LIGHT FOUND INOP. PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTS IN REF TO TASK AMM 33-51-00-715-001, OPS CHECK GOOD NO FURTHER DEFECTS NOTED AT THIS TIME.SDR CALA2025050204417Bleed Valve · faultedL ENG OVERHEAT ON CLIMBOUT WITH ASSOCIATED BLEED OFF AND PACK OF F. COULD NOT RECOVER PERFORMED FIM 26-11 FAULT TREE 807. SEE L/P 4678470 FOR REPLACEMENT OF # 1 ENGINE FAN AIR VALVE (DUE TO HIGH PRECOOLER OUT DUCT TEMPERATURE) AS PER MM-36-11-16/401. RAN # 1 ESDR CALA2025042904306Slide · not reportedENTRY AND SERVICE DOOR EMERGENCY ESCAPE SLIDES REPLACE {B767-25-3-7034} - REMOVED L1 SERVICE DOOR EMERGENCY ESCAPE SLIDES REF AMM 25-66-01. INSTALLED L1 SERVICE DOOR EMERGENCY ESCAPE SLIDE IN REF WITH AMM 25-66-01SDR CALA2025043004350Pressure Switch · faultedDEBRIEFED CREW, NO OVWT LANDING, 32K FEET, FUEL FILTER BYPASS R MSG, ENG APPEARED AND SHOWED NORMAL, ALL INDICATIONS NORMAL. 2 HRS OUT. ADVISORY TO STATUS. 304-283-6970. PILOT. REMOVED AND REPLACE #2 ENGINE FUEL FILTER REF AMM 73-11-02-404-008-H00, LEAK CHECK SDR CALA2025042904320Duct · debondedRH ENG TRANSLATING SLEEVE RH C-DUCT INNER SKIN DISBONDED, REF LP 4622229. ACCOMPLISH AMM 03-51-00-210-801 WALKAROUND INSPECTION TO VERIFY NO ADDITIONAL DAMAGE DUE TO PARTS LOSS. WALK AROUND INSPECTION CARRIED OUT AS PART OF THE ETOPS PDSC. NO FURTHER DAMAGE SSDR CALA2025042504243Lamp · inoperativeEMERGENCY LIGHTS OPERATIONAL CHECK FOUND SLIDE AND OVERWING ESCAPE LIGHT EMERGENCY INOPERATIVE NEAR DOOR 4L/H. REMOVED AND REPLACED LAMP FROM SLIDE AND OVERWING ESCAPE LOGHT EMERGENCY NEAR DOOR 4L/H AS PER AMM TASK 33-51-06-902-082. GOOD FOR SERVICE.SDR CALA2025042504220Bleed Valve · failedR ENG BLEED FAIL AT 75 KTS ON TAKEOFF... CHECKLIST RAN AND RESET WITH NO DEMAND HPSOV REPLACED AS PER AMM TASK 36-11-07-424-014-003 REV 144, SATIS.SDR CALA2025042504251Warning Message · false activationLOW SPEED REJECT...90KTS BTMS BELOW 3.2 ALL R ENG BLEED FAIL TO OFF ON TAKE OFF ROLL HI ENERGY STOP INSPECTION C/OUT IAW AMM 05-51-14-212-036-001 R144 NO DAMAGE FOUND. REJECT T/OFF INSPECTION C/OUT IAW AMM 05-51-14-212-041-001 R144 ACCOMPLISHED, NO DAMAGE FOUNSDR CALA2025041703956Idg · faultedRT GEN OFF. RESET ONCE. FAILED A SECOND TIME. PERFORMED BPCU BITE PER MM 24-11- 00. FOUND MM 24-35002 FOR RIDG PHASE A CURRENT DISAGREE. PERFORMED BPCU BITE PER MM 24-11-00. FOUND R IDG PHASE A CURRENT DISAGREE, MM 24-35002. PERFORMED BPCU BITE PER MM 24-11-00SDR CALA2025041503834Cover · damagedSLIDE COVERED REMOVED FOR REPAIRS. SLIDE COVER IS BEING HANDED OVER TO SHEETMATAL FOR REPAIR. "ESCAPE SLIDE RENDER CHECKLIST" IS FOLLOWED. SLIDE "PIN" IS INSTALLED. PRIOR TO INSTALLING SLIDE COVER PLZ INSPECT AND REMOVE "PIN". REINSTALLED THE SLIDE COVER ON THSDR CALA2025041103737Blowout Panel · missingPDA 2 REF LOGPAGE 4431885, LEADING EDGE #4 SLAT INBOARD BLOWOUT PANEL FOUND MISSING. REATTCHED NEW BLOWOUT PANEL TO LEADING EDGE SLAT PANEL PER SRM 51-40-02.SDR CALA2025041103683Pressure Switch · faultedRIGHT FWD WING PRESSURE SWITCH REQUIRE REPLACEMENT PER JC 2820-02563-002 REMOVED AND REPLACED RIGH FWD PRESSURE SWITCH IAW AMM 28-42-01. OPS CK GOOD CK GOOD.PARTSSDR CALA2025040903660Wire · exposedAS REPORTED BY FA... WIRES HANGING ABOVE ROWS 40-41 ASSOCIATED W ITH EMER EXIT LIGHTS BACK COVER INSTALLED REF AMM TASK 33-51-10-962-104.PARTS USED: 64-2526-3-0241, QTY :1SDR CALA2025040803626Seal · faultyREMOVED L3 SLIDE SAFTEY PIN AND STOWED. FOR MAINTENANCE REINSTALLED L3 DOOR SLIDE SAFTEY PIN PER WORK CARD 64-2560-1-3801.PARTS USED: 99-5611-3-0025, QTY :1 CORRECT ENTRY SHOULD BE, "INSTALLED L3 SLIDE SAFTEY PIN FOR MAINTENANCE" CORRECT ENTRY SHOULD BE, "REMSDR CALA2025040703612Shutoff Valve · faultyL ENG BLEED OFF EICAS WITH L PACK OFF CAME ON FL350 2HR30MIN INT O FLT INTERROGATED ASCTU AND FOUND LH PRV FAILED. REMOVED AND REPLACED LH PRV REF AMM 36-11-18 AND PERFORMED OPS AND GROUND CHECKS REF AMM 36-23-00 AND 36-00-26, OPS AND BITE CHECK GOOD. ENGINE RSDR CALA2025040403535Warning Message · false activationL AFT ENT DOOR CAUTION MOMENTARILY DISPLAYED SHORTLY AFTER LAND ING INSPECTED L AFT ENTRY DOOR. PERFORMED L AFT ENTRY DOOR FUNCTIONAL TEST REF AMM 52-71-00-735-072. FOUND SATISFACTORY. NO OTHER FAULTS FOUND AT THIS TIME.SDR CALA2025040303489Sensor · faultedDRG CLB THRU FL180 L PAC K MODE AND L PACK OFF CA UTION LITES CA ME ON.THEY WENT AWAY 3-4 MINS LA WHILE TROUBLESHOOTING FOUND MESSAGE 21-51012 ON LEFT CTC, PERFORMED INSPECTION OF LEFT PACK HEAT EXCHANGER REF FIM TASK 21-51 TASK 855, AND FOUND NO DAMAGE OR BLO
Back to Boeing 767-424ER