Boeing 767-432ER
Service difficulty reports · 3,098
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '767432ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1114611821Charger · inoperativeSEAT MOUNTED EMERGENCY PATH LIGHTS INOPERATIVE AT SEATS 1B-4B. MAINTENANCE REPLACED CHARGER ASSEMBLY PER AMM. OPERATION CHECK IS NORMAL.SDR DALA1113811821Pump · failedCTR HYD PUMP CAUTION LIGHT ON LADING FOUND ADP PUMP CAME APART AND DAMAGED THE SKIN AND ASSOCIATE PARTS. REPAIR PER PRI/ERA 490123-14 AND 490205-14 AT FUSELAGE STA 1153 TO 1175 STR 27L TO STR 30L.SDR DALA1110771807Light · inoperativeEMERGENCY EXIT SIGN AT DOOR 3R IS INOPERATIVE. MX REPLACED THE LENS. SYS OPS IS NORMAL.SDR DALA1110781819Wire · brokenEMERGENCY PATH LIGHTS ON THE LT SIDE OF MID-GALLEY WIRES WERE BROKEN. MX REPLACED LIGHT. SYS CHECKS NORMAL.SDR DALA1110151810Heater · defectiveSHORTLY AFTER TAKEOFF, IN-FLIGHT REPORTED A BRIEF ACRID ODOR IN THE FWD CABIN. DUE TO THE INABILITY TO IDENTIFY THE SOURCE OF THE ODOR, THE RAM TEAM ELECTED TO BRING THE FLIGHT BACK TO DEPARTURE FOR MX EVALUATION. MX FOUND THE L1 DOOR HEATER DEFECTIVE AND RSDR DALA1110121818Skin · delaminatedLT WING OTBD FLAP OTBD L/E DELAMINATED AND REPAIRED IAW SRM 57-53-01, REPAIR 1 AND SRM 51-70-03, FIG 5.SDR DALA1112031814Floorbeam · corrodedM/D STA 325 RBL 30 TO RBL 50 FLOORBEAM FOUND CORRODED AND REPAIRED IAW SRM 53-00-51 REPAIR 1 FIG 201.SDR DALA1109701817Battery Pack · failedEMERGENCY LIGHT BATTERY PACKS AT 19A AND 32FG FAILED. MX REPLACED THE BATTERY PACKS. SYS OPS IS NORMAL.SDR DALA1109691817Battery Pack · failedEMERGENCY LIGHT BATTERY PACK AT SEAT 32AB AND 43AB FAILED. MX REPLACED THE BATTERY PACK. SYS OPS IS NORMAL.SDR DALA1109251809Fan · failedFLIGHT DIVERTED, DUE TO ELECTRICAL SMELL WITH ASSOCIATED LT RECIRCULATION FAN MESSAGE. MX VERIFIED THE LT RECIRCULATION FAN FAILED AND REPLACED IAW AMM, PLAC WAS REMOVED. SYS OPS IS NORMAL.SDR DALA1113201815Floorbeam · corrodedM/D - STA 324 RBL 22 TO 55 FLOORBEAM UPPER CHORD FOUND CORRODED AND REPAIRED IAW SRM 53-00-51 FIG 201, REPAIR 1.SDR DALA1107421820Skin · detachedRT WING NR9 SLAT WEDGE UPPER SURFACE INBD EDGE SKIN DETACHED METAL. HOT BOND REPAIR PERFORMED IAW SRM 57-43-52. REPAIR 1, FIG 201 AND SRM 51-70-10 REPAIR 4, FIG 202.SDR DALA1102921802Power Supply · inoperativeEMERGENCY LIGHTS AT ROWS 1 THROUGH 4 ON THE RT SIDE ARE INOPERATIVE. MX FOUND THE POWER SUPPLY BAD AND REPLACED. SYS OPS IS NORMAL.SDR DALA1123661812Fairing · delaminatedLT WING I/B MAIN FLAP LEADING EDGE O/B NOSE FAIRING FOUND DELAMINATED. COMPOSITE WET LAY UP REPAIR CARRIED OUT AT DELAMINATED AREA IAW SRM 57-53-01 TABLE 1 AND SRM 57-70-03 PARA 5.A FIG 5.SDR DALA1106751820Floorbeam · corrodedSTA 325, RBL 50" FLOORBEAM UPPER FLANGE FOUND CORRODED AND REPAIRED IAW SRM 53-00-51, FIG 201, REPAIR 1.SDR DALA1101271801Skin · dentedFUSELAGE SKIN DENTED AT FS 1506 & 1514. REPAIRED IAW ERA 482800-14AD.SDR DALA1100521815Light · inoperativeEMERGENCY PATH LIGHTS AT GALLEY L2 DOOR ARE INOPERATIVE. MX REPLACED THE LIGHT ASSY. SYS OPS IS NORMAL.SDR DALA1052811817Unknown · odorELECTRICAL ODOR COMING FROM THE EYEBALL VENT MID GALLEY, TURNED OFF GASPER FAN SWITCH AND ODOR STOPPED, PULLED CIRCUIT BREAKER R17 AS DIRECTED BY MX CONTROL. MX INSPECTED AREA NO TROUBLE FOUND. CIRCUIT BREAKER RESET. SYS OPS IS NORMAL. ETOPS CATEGORY 'E'SDR DALA1051671821Fan · failedLT RECIRCULATION FAN IS INOPERATIVE, SMOKE/BURNING ODOR IN THE CABIN. MX REPLACED THE RECIRCULATION FAN. SYS OPS IS NORMAL.SDR DALA1051991814Wire · brokenEMERGENCY LIGHTS AT L4 AND R4 ARE INOPERATIVE. MX REPAIRED THE BROKEN WIRES FOR POWER SUPPLY PLUG D110722. SYS OPS IS NORMAL.SDR DALA1051201814Battery Pack · inoperativeEMERGENCY LIGHTS AROUND L4 AND R4 DOORS ARE INOPERATIVE. MX REPLACED THE BATTERY PACK AT M1210. SYS OPS IS NORMAL.SDR DALA1051211814Battery Pack · inoperativeEMERGENCY LIGHT AT L4 AND R4 DOOR ARE INOPERATIVE. MX REPLACED THE BATTERY PACK AT R4 F/A SEAT. SYS IS NORMAL.SDR DALA1050531818Battery Pack · dischargedEMERGENCY LIGHTS ON CEILING AROUND R1 DOOR ARE INOPERATIVE. MX REPLACED THE BATTERY PACK M730 AND CHARGER. SYS OPS IS NORMAL.SDR DALA1034501814Battery Pack · inoperativeEMERGENCY LIGHT AT R4 AND L4 DOOR ARE INOPERATIVE. MX REPLACED THE BATTERY PACK M1210. SYS OPS IS NORMAL.SDR DALA1034311814Battery Pack · inoperativeEMERGENCY EXIT LIGHTS AFT ARE INOPERATIVE. MX REPLACED THE BATTERY PACK. SYS OPS IS NORMAL.SDR DALA1032701818Wire Harness · disconnectedEMERGENCY LIGHTS AT SEAT 20B ARE INOPERATIVE. MAINTENANCE FOUND THE HARNESS DISCONNECTED AT 19B AND RECONNECTED. SYSTEM OPERATION IS NORMAL. (2010-D1371) (DL764103202)SDR DALA1031281805Connector · looseEMERGENCY PATH LIGHTS AT 37A ARE INOPERATIVE. MAINTENANCE FOUND A CONNECTOR AT 37A LOOSE AND RECONNECTED. SYSTEM OPERATION IS NORMAL. (2010-D1349) (DL764103070)SDR DALA1029861803Light · inoperativeDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY FLOOD LIGHT FOR DOOR 2R EVACUATION SLIDE WAS NOT FUNCTIONAL. MAINTENANCE REPLACED THE LIGHT ASSEMBLY AND FUNCTIONALLY CHECKED IT. (2010-D1287) (DL764102964)SDR DALA1026291807Connector · shortedA HINT OF SMOKE AND BURNING ODOR CAME FROM THE LT FWD OVERHEAD ENTRY LIGHT. THE F/A TURNED OFF THE LIGHT SWITCH AND THE ODOR AND SMOKE DISAPPEARED IMMEDIATELY. MX FOUND AN ISO SHORT BETWEEN J14 TO J1. THE DAMAGED PIN, NR43 IN J1 CONNECTOR OF F/A PANEL, WAS RESDR DALA1025741802Oven · fireTHIRTY MINUTES AFTER DEPARTURE, F/A REPORTED THE ODOR OF SMOKE IN THE AFT GALLEY. CREW STATED THAT AFT GALLEY NR 4 OVEN EMITTED ODOR AND FLAMES. AFTER THEY PULLED C/B THE SMOKE AND FLAME EXTINGUISHED. SOURCE WAS CONFIRMED. FLT CONTINUED REMOVED OVENS 3 AND 4 ISDR DALA1024391816Acm · seizedSULFER TYPE ODOR THOUGHOUT CABIN AND FLIGHT DECK/ SMOKE/ HAZE OBSERVED BY F/A. ON LANDING HAD EICAS MESSAGE LT ACM. FOUND LT ACM SEIZED.SDR DALA1023891816Acm · seizedSULFUR TYPE SMELL THROUGHOUT CABIN AND FLIGHT DECK, SMOKE, HAZE OBSERVED BY F/A ON LANDING AN EICAS MESSAGE ABOUT THE LT ACM SHOWED UP. MX FOUND THE LT ACM SEIZED.SDR DALA1023431802Indicator · malfunctionedAFTER T/O, STANDBY ATTITUDE INDICATOR FAILED. R & R STANDBY ATTITUDE INDICATOR IAW AMM CHECKED GOOD.SDR DALA1023161809Fuse · failedEMERGENCY LIGHTS AT SEATS 6A-10A ARE INOPERATIVE. MX REPLACED A FUSE IN M7235. SYS OPS IS NORMAL.SDR DALA1022611810Wire · pinchedEMERGENCY ESCAPE PATH LIGHTS AT SEAT 27B ARE INOPERATIVE. MX REPAIRED PINCHED WIRE ON SEAT BETWEEN 26 AND 27B. SYS OPS IS NORMAL.SDR DALA1021651808Socket · intermittentEMERGENCY ESCAPE PATH LIGHT INOPERATIVE AT 6D. LIGHT SOCKET IS INTERMITTENT. CURRENTLY ON MCO.SDR DALA1020411811Battery Pack · inoperativeEMERGENCY PATH LIGHTS FROM SEATS 38B-44B AND 38F-44F FAILED OP 6804. MX REPLACED BATTERY PACKS M734 AND M738 IAW AMM. SYS OPS IS NORMAL.SDR DALA1020401811Battery Pack · inoperativeEMERGENCY PATH LIGHTS FROM SEATS 5B TO 27B FAILED OP 6804. MX REPLACED BATTERY PACKS M7235 AND M 737 IAW AMM. SYS OPS IS NORMAL.SDR DALA1020391807Bulb · missingEMERGENCY PATH LIGHT AT SEAT 15A IS INOPERATIVE. MX FOUND LIGHT BULB MISSING AND REPLACED. SYS OPS IS NORMAL.SDR DALA1018491806Warning System · false activationAT APPROX 60 KTS UNSCHEDULED STAB TRIM EICAS CAUTION MESSAGE WITH BEEPER CAME ON. ABORTED TAKEOFF. MAX SPEED 75 KTS. RETURNED TO GATE PER FIM 27-09-00 FIG 106. BITE TEST OF STAB TRIM MODULE FAULTS FLAP/SLAT POSITION MODULE 27-41026 MESSAGE CLEARED. TESTESDR DALA10186761804Charger · inoperativeEMERGENCY ESCAPE FLOOR LIGHTS BETWEEN SEATS 1AB TO 5AB ARE INOPERATIVE. MAINTENANCE REPLACED EMERGENCY LIGHT CHARGER M736. SYSTEM OPERATION IS NORMAL (2010-D0961)(DL764102081).SDR DALA1018671804Battery Pack · dischargedDURING OPERATIONAL CHECK OF EMERGENCY LIGHTS FOUND RIGHT AFT EMERGENCY OVERWING EXIT DOOR INOPERATIVE. REPLACED BOTH CHARGER BATTERY PACKS FOR EQUIPMENT M1671 (2010-D0948)(DL764102081).SDR DALA1018181801Shutoff Valve · malfunctionedAFTER T/O RECEIVED RT HPSOV EICAS MSG. UNABLE TO RESET. RETURN TO ATL DUE TO GATE AND CREW AVAILABILITY. FWD TO MCO /PLAC PER MEL 36-11-02 HPSOV LOCKED CLOSED NR 2 ENG (ODI 2010-D0925) (DL764101994).SDR DALA1018101804Charger · inoperativeEMERGENCY ESCAPE FLOOR LIGHTS INOP FROM SEATS 1AB TO 5AB. REPLACED EMERGENCY ESCAPE LIGHTS CHARGER ASSY M736 PER AMM. ALL EMERGENCY ESCAPE LIGHTS NOW CHECK GOOD PER AMM (DL764101995).SDR CALA2010072700346Squib · blownSQUIB TEST NR 1 DOESN’T COME ON (LIGHT) REF W/C 64-2620-1-7102. REMOVED AND REPLACED FLOW VALVE SQUIBS PER MM 26-23-06. OPS CHECKED OK FWD CARGO.SDR DALA1017101813Connector · disconnectedDURING SCHEDULED MAINTENANCE THE EMERGENCY ESCAPE PATH LIGHTING FROM ROW 21 FG TO 28 FG WAS FOUND TO BE INOPERATIVE. MAINTENANCE FOUND AN ELECTRICAL CONNECTOR HAD BEEN DISCONNECTED AT SEAT 21F AND RECONNECTED THE EEPLS TO THE POWER SOURCE. SYSTEM OPERATION SDR DALA1017311806Fuse · blownDURING DRC FOUND EMERGENCY PATH LIGHTS AT 1D-4D INOPERATIVE. MAINTENANCE FOUND FUSE IN THE BATTERY CHARGER PACK M6756 BAD AND REPLACED. SYSTEM OPERATION IS NORMAL (2010-D0868)(DL764101943).SDR DALA1017301818Connector · unsecureEMERGENCY PATH LIGHTS AT ROW 21-27 RIGHT ARE INOPERATIVE. MAINTENANCE SECURED WIRE CONNECTOR AT ROW 20. SYSTEM OPERATION IS NORMAL (2010-D0867)(DL7646101942).SDR DALA1016521819Hydraulic Line · brokenTHE FLIGHT RETURNED TO JFK DUE TO LOSS OF THE CENTER HYDRAULIC SYSTEM AND A FLAPPING NOISE FROM UNDER THE RIGHT WING AREA. THE FLIGHT CREW DECLARED AN EMERGENCY AND LANDED OVERWEIGHT AT 351,000 POUNDS. TOUCHDOWN WAS AT 170 KTS BUT NO DESCENT RATE WAS GIVEN.SDR DALA1017351802Connector · looseEMERGENCY LIGHTS AT ROW 16A-21A ARE INOPERATIVE. MAINTENANCE RE-SECURED LOOSE CONNECTOR UNDER SEAT 17B. SYSTEM OPERATION IS NORMAL (2010-D0874)(DL764101947).
Back to Boeing 767-432ER