Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011040101574Connector · dirtyTHE 3L EXIT LIGHT IN AISLE FLICKERS ON & OFF INTERMITTENTLY. CLEANED CONNECTOR ON LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2011040101567Seal · leakingENG 2 FUEL LEAK FROM DRAIN NR 9 (STRUT) FOUND ON PREFLIGHT CHECK. LEAK CHECK TO BE CARRIED OUT. SAMC TEXT: THIS IS NR 2 ENG THAT REQUIRES FUEL LINE LEAK CHECK DUE TO O-RINGS HAVE BEEN CHANGED ON THE STRUT COUPLING LOCATION. SAMC TEXT: REPAIR PER MM. FUEL SDR UALA2011033101545Display · inoperativeRT COPILOT PFD BLANK. SWAPPED LEFT DU INTO CENTER POSITION. CENTER DU IS INOP. REPLACED CTR LWR DU AS PER MM. INSTALLATION TEST, PASSED.SDR UALA2011033101544Cradle · defectiveINTERPHONE BUSY IN COCKPIT. SWAPPED IN PA-CI CONTROLLER PER MM, NO HELP. SWAPPED IN AUDIO MANAGEMENT UNIT PER MM, NO HELP. ALSO REPLACED COCKPIT INTERPHONE JACK, NO HELP. PROBLEM SEEMS TO BE WITH COCKPIT HANDSET CRADLE MAGNET LOCATION, CAUSING PHONE NOT TOSDR UALA2011033101558Cover · missingPER CM2020 EEL LIGHT COVER MISSING AT MID LAV. REPLACED COVER. EEL LIGHT CHECKS OKAY.SDR UALA2011033001532Battery Pack · dischargedEMERGENCY PATH LIGHTING INOP AROUND LEFT SIDE MID-CABIN COACH LAVATORIES. REPLACED ASSOCIATED BATTERY PACK AND CHARGER. OPS GOOD.SDR UALA2011033001531Battery Pack · dischargedEMERGENCY LIGHTS INOP IN THE LEFT AISLE CEILING PANELS FROM ROW 17 TO ROW 33. REPLACED ASSOCIATED BATTERY PACK. OPS GOOD.SDR UALA2011033001530Battery Pack · dischargedINTERNAL EMERGENCY LIGHTS INOP AT DOOR 3L ON THE FWD AND AFT SIDES OF DOOR. REPLACED ASSOCIATED BATTERY PACK. OPS GOOD.SDR UALA2011033001529Battery Pack · dischargedEXTERNAL EMERGENCY LIGHTS INOP AT DOORS 1L, 3L AND 4L. REPLACED ASSOCIATED BATTERY PACK, OPS GOOD.SDR UALA2011033001528Connector · unsecureEMERGENCY PATH LIGHT INOP AT SEAT 3E, AFT LIGHT. SECURED CONNECTOR. OPS GOOD.SDR UALA2011033001527Light · inoperativeEMERGENCY PATH LIGHT INOP AT SEAT 42D. REPLACED LIGHT AT SEAT. OPS GOOD.SDR UALA2011033001526Battery Pack · dischargedINTERNAL EMERGENCY LIGHTS INOP AT DOOR 2L ON THE TOP AND FWD SIDE OF DOOR. REPLACED ASSOCIATED BATTERY PACK. OPS GOOD.SDR UALA2011040101571Blade · chippedNR 1 ENG ONE EACH BLADE L/E TIP CHIPPED (SIX O'CLOCK POSITION). BLADE HAS PIECE MISSING AROUND .093 DEEP AND .156 LONG, BLADE IS OUT OF LIMITS PER MM. TALKED TO OPBEMC, BLADE OUT OF LIMITS. REPLACED DAMAGED BLADE PER EG 5443-1. REMOVED DAMAGE BLD S-N CBDUSDR UALA2011033001533Charger · faultyAPU AUTO SHUTDOWN WITH APU BATTERY MESSAGE, AND APU BATTERY CHARGER MESSAGE. REPLACED APU BATTERY AND APU BATTERY CHARGER. APU DEFERRED INOP, MESSAGES HAVE CLEARED. APU REPLACED (S/N P1119-331) PER MM, OPS NORMAL.SDR UALA2011033101557Light · detachedEEL LIGHT DETACHED FROM ENDBAY AT SEAT 2E. SECURED EEL TO ENDBAY.SDR UALA2011033101556Light · unsecureEEL NOT SECURED ON SEAT 3F (AFT SIDE). SECURED AFT EEL.SDR UALA2011033101555Cover · missingEEL LIGHT MISSING COVER AFT GALLEY. REPLACED COVER. EEL LIGHT CHECKS OKAY.SDR UALA2011033101554Light · brokenEEL LIGHT BROKEN HOUSING ASS'Y AT PARTITION MID GALLEY. REPLACED EEL LIGHT ASSY AND RESPLICED WIRING.SDR UALA2011033001522Coupler · faultyHF RADIO RIGHT WON'T TUNE. NEED HF ANTENNA COUPLER. REPLACED RT HF COMM COUPLER, MAT BITE TEST OK. DUE TO NR 2 HF COUPLER REPLACEMENT, NEED TO ACCOMPLISH SYSTEM OPS CHECK OUTSIDE THE HANGER. NR 2 HF SYS FAILS OPS CK. DF0928 FOR UPDATE. REPLACED RT HF COMSDR UALA2011033001521Power Supply · faultyM33097 EMER PWR SUPPLY DID NOT KEEP IT'S LIGHTS ILLUMINATED FOR 15 MINUTES AT R2 DOOR. REPLACED POWER SUPPLY, OP CHECK GOOD.SDR UALA2011033001520Power Supply · faultyM33406 EMER PWR SUPPLY DID NOT KEEP IT'S LIGHTS ILLUMINATED FOR 15 MINUTES AT L3 DOOR. REPLACED POWER SUPPLY. OP CHECK GOOD.SDR UALA2011033001541Slide Raft · damagedTHE NR 4 RT PAX ENTRY SLIDE-RAFT BACK-BOARD HAS PUNCTATION (0.4"*0.5").SDR UALA2011033001540Slide · crackedTHE NR 4 LT PAX ENTRY SLIDE-RAFT BACK-BOARD SURFACE CRACKED (0.7").SDR UALA2011033001539Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 1 LT UPPER EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TESTS OKAY.SDR UALA2011033001538Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 3 RT AROUND EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TESTS OKAY.SDR UALA2011033001537Window · defectiveFOUND MILKY WHITE AREA IN WINDOW NR 3 LT AROUND EDGE IN COCKPIT. REPLACED WITH NEW WINDOW PER AMM, WINDOW HEAT CONTROL SYSTEM TEST OKAY.SDR UALA2011033001519Strut · crackedNR 1 ENG REAR TRANSITION AREA OUTER DUCT STRUTS 3 THROUGH 10 HAVE CIRCUMFERENTIAL CRACKS STRUT NR 3-.75, 4-.875,5-.625, 6-1.125, 7-.875, 8-1.125, 9-1.0, 0-.875. REF MM 72-54-01,PG. 605 THROUGH CRACKS ONE MAX PER EACH STRUT PERMITTED. MAX LENGTH 2 IN. REQUESDR UALA2011032901501Seal · pinchedFUEL NOTED AT PRESSURE SWITCH OF APU DC FUEL PUMP AT LT FWD SPAR AREA. REPLACED APU PUMP SWITCH PER MM. NO FUEL LEAK FOUND AFTER RE-ACTIVATING PUMP AND FUEL PRESS SWITCH O-RING REPLACED. SWITCH WAS NOT FULLY SECURED UPON REMOVAL, SEAL WAS PINCHED.SDR UALA2011032801490Pcu · leakingWALK AROUND CHECK FOUND SPOILER NR 8 PCU LEAKING. RUNNING HYD LEAK FROM PCU CASE WHEN PRESSURIZED, CHKD HYD TUBE AND CONNECTORS NML. RPL'D PCU PER MM AND OPERATION TEST PER MM. ALL IS NORMAL. NO FAULT AND NO LEAKING FOUND.SDR UALA2011032901500O-Ring · leakingHYDRAULIC LEAK AT LEFT LANDING GEAR WELL. INPUT LINE TO SYS FLIGHT CONTROL SHUT-OFF VALVE IS LEAKING AT LINE FITTING (70 DROPS PER MINUTE). REPLACED BAD O-RING. LEAK CHECKED, NO LEAKS.SDR UALA2011033101562Seal · leakingFLUID LEAK FROM PYLON AREA. DUE TO A EARLIER ISSUE WITH POSSIBLE FUEL LEAK FROM THE TUBE IN THE NR PYLON AREA, NR 9 DRAIN LINE CLEARS THIS AREA, PLEASE REPLACE THE SEAL AT CONNECTION -C- IN IPC 28-22-51-002A PG2 ITEM REQUIRED IS 145, PCN 752-1263. TWO SEALS ASDR UALA2011032801487Pump · faultyFUEL BURNED OUT OF LEFT TANK W CTR PUMPS ON. 3800 LB IMBAL DEVELOPED. SAMC TEXT: FUEL BURN OUT OF LT MAIN TANK W CTR PUMPS ON. 3800 IMBAL. CREW BALANCED IT THEN RESTORED TO NORMAL OPS. FUEL KEPT PUMPING FROM LT TANK W CTR PUMPS ON UNTIL LT MAIN PUMPS SELECTSDR UALA2011032801480Apu · malfunctionedAPU CONTROL STATUS MSG. APU CHECK FOUND METAL IN FILTER. APU INOPED PER MEL. AT NEXT MAINTENANCE OPPORTUNITY WITHOUT DISRUPTING SCHEDULES, NEED TO REPLACE APU AT NEXT OPPORTUNITY. REPLACED APU PER MM.SDR UALA2011032801475Control Valve · faultyPACK FLOW CONTROL VALVE RT(BUT NOT BOTH) OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. STATUS MSG-2124102 LATCHD TA MODE. SUPPLEMENTAL DATA UPDATE REPLACED RH UPPER FLOW CONTROL VALVE, OPERATION CK'D NORMAL.SDR UALA2011032801468Converter · faultyLEFT BACKUP GENERATOR IS OFF OR HAS FAILED. ELECTRICAL BACKUP GENERATOR LT EICAS MESSAGE. ATTEMPTED RESET. MESSAGE RE-APPEARED. REPLACED BUG CONVERTER PER MM. NO FAULT NOTED.SDR UALA2011032801464Skin · damagedEXTERNAL FUSELAGE SKIN HAS DAMAGE AT S-45R LAP JOINT, STA 157.00 TO STA 164.00. EXTERNAL FUSELAGE SKIN REPAIRED AT S-45R LAP JOINT, STA 157.00 TO STA 164.00, THIS REPAIR APPROVED FOR STATIC STRENGTH ONLY, PENDING THE RESULTS OF A DAMAGE TOLERANCE ANALYSIS, A SDR UALA2011032801457Pressure Sensor · faultyEQUIPMENT COOLING ADVISORY MSG AS PER MT 21-004 R3, CLEANED SUPPLY FAN INLET AIR FILTER AND CLEANED FD PRESSURE TRANSDUCER PLUG. EQUIPMENT COOLING GROUND TEST PASSED WITH NO STATUS OR ADVISORY MESSAGE. IDENTIFIED THE PROBLEM RMVG THE CONNECTOR FROM FD PRESSUSDR UALA2011032501449Transceiver · missingPORTABLE VHF TRANSCEIVER MISSING AT DOOR 4R. REPLACED VHF TRANSCEIVER.SDR UALA2011032501440Sensor · faultyBLEED PRSOV-R STATUS MSG DISPLAYED. AHM PROGRAM HAS DETECTED FAULT MESSAGE 36-10380 PRSOV-R FAILED CLSD IN CRUISE. CREW REPORTS NORMAL BLEED OPERATION. THIRD CONSECUTIVE LEG WITH THE SAME FAULT. ACP FAULT ISOLATION PROCEDURE PER FIM OR APPLY MEL 3611G. REPLACESDR UALA2011032501416Transmitter · faultyPOTABLE WATER SYSTEM SERVICED TO FULL, BUT INDICATIONS SHOW 3 QTR. SERVICED TO FULL, INDICATIONS INOP IN CABIN AND SERVICE PANEL. WHEN CLEARING DEFER ITEM REMOVE DF-CF PLACARD FROM INTERIOR OF BOTH POTABLE WATER SERVICE PANEL. ALL QTY INDICATORS SHOWS 3 QTR,SDR UALA201108301401Windshield · delaminatedREPLACE L&R NR 1 WINDSHIELDS DUE TO REPORTS OF DELAM OF THE LEFT AND RIGHT NR 1 WINDSHIELDS. REPLACED BOTH NR 1 LT & RT COCKPIT WINDSHIELDS. NOW WITHIN LIMITS. (ORIGINAL CONTROL NUMBER UALA2011032401401, CHANGED DUE TO DUPLICATION WITH 2 VIABLE RECORDS)SDR UALA2011032401405Wire Harness · looseEMERGENCY LIGHTS INOP AT SEATS 1F (BOTH) & 2E (AFT). RELAMPED 2E, CHECKS GOOD. NO POWER AT 1F DUE TO LOOSE HARNESS CONNECTOR AT SEAT 1C. REMOVED CENTER CONSOLE ASSY AT 2E. FOUND HARNESS RUNS UNDERNEATH 1C. REPLACED BOTH SEAT 1F EMERGENCY LIGHT ASSY'S ANDSDR UALA2011032401406Generator · faultyPRIOR TO DEP, APU GEN DROPS OFF LINE, HISTORY. DUE HISTORY APU GEN INOP. APU GCU REPLACED PREVIOUSLY. SUSPECT APU GEN. APU GENERATOR PCN IS 661-9003. REPLACED APU GENERATOR, OPS CHECKS OKAY.SDR UALA2011032401401Windshield · delaminatedREPLACE L&R NR 1 WINDSHIELDS DUE TO REPORTS OF DELAM OF THE LEFT AND RIGHT NR 1 WINDSHIELDS. REPLACED BOTH NR 1 LT & RT COCKPIT WINDSHIELDS PER MM56-11-01.SDR UALA2011032401400Gcu · faultyAPU NO GO ON LINE WITH GENERATORS. AIR OUTPUT OK. NO TIME TO TS. REPLACED APU GEN CONTROL UNIT PER AMM. TEST OK, OPERATIONAL CHECK OKAY.SDR UALA2011032301398Generator · faultyAPU GEN INOP AT DEPARTURE. REPLACED APU GENERATOR AND T1 & T2 FEEDER CABLE PER MM. GEN OPS NORMAL.SDR UALA2011032301390Wire Harness · faultyEMERGENCY EVACUATION SIGNAL SYSTEM DEFECTIVE AT ATTENDANT SEAT AT DOOR 3L. 3L POSITION DOES NOT ALARM OR LIGHT WHEN SYSTEM TESTED AT OTHER LOCATIONS, IT DOES LIGHT AND ALARM WHEN TESTED AT 3L, BUT NO ALARM OR LIGHTS AT ANY OTHER LOCATION. PIGGYBACK GOOD EVACSDR UALA2011032201372Skin · damagedEXT FUSE BS 157 STR 34R & 39R, LIGHTNING STRIKE REPAIR AREA HAS EXCESSIVE MATERIAL REMOVED. ORIG THICKNESS .08 0 INCH THICK, U-S INSP FOUND .0562 INCH REMAIN. MAJOR REPAIR ACCOMPLISHED: UPPER DOUBLER REPAIR DONE, REINSTALLED EQUIPMENT IN E&E COMPARTMENT. REFSDR UALA2011032301399Insulation · damagedELEC GEN OFF APU AUXILIARY POWER BREAKER (APB) OPEN AND AUXILIARY POWER UNIT (APU) GENERATOR RUNNING OR APU GENERATOR SWITCH OFF - ADVISORY. LATCHED MSG 24-31663 ON ARRIVAL. ACCOMPLISHED RESET PER FIM, NO HELP. ELECTRIC PAGE SHOWS NIL VOLTAGE & FREQUENCY. SDR UALA2011032101364Pump · faultyA 4000 LB LATERAL FUEL IMBALANCE. SAMC TEXT: IAD MM ON ARRIVAL AND BEFORE REFUELING ACCOMPLISH A DRIP OF THE MAIN TANKS TO CONFIRM QUANTITY READINGS. TESTED PER MM. TEST PASSED. LEFT CENTER PUMP PRESSURE LIGHT ILLUMINATED AT 2300 LBS. REPLACED LEFT CENTER
Back to Boeing 777-222