Service difficulty report · Transmitter · Boeing 777222

Difficulty date
March 24, 2011
Submitted
March 25, 2011
Operation
Air carrier
Aircraft
N782UA
Make and model
Boeing 777222
Aircraft serial
26948
Aircraft time
62,036 hours, 9,051 cycles
Engine
Pwa PW40903
Part
Transmitter
Part number
301360107
Condition
Faulty
Location
Potable Water
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

POTABLE WATER SYSTEM SERVICED TO FULL, BUT INDICATIONS SHOW 3 QTR. SERVICED TO FULL, INDICATIONS INOP IN CABIN AND SERVICE PANEL. WHEN CLEARING DEFER ITEM REMOVE DF-CF PLACARD FROM INTERIOR OF BOTH POTABLE WATER SERVICE PANEL. ALL QTY INDICATORS SHOWS 3 QTR, WITH TANKS FULL. MAY REQUIRE SUMMATION UNIT M38004, (566-0143). 1EA 566-02143 RCS 769-56M AT SFOJL HB. REPLACED SUMMATION UNIT 3-23-11, NO HELP. STILL SHOWS 3 QTR FULL. CTR TANK TRANSMITTER WILL NOT CALIBRATE. L+R CALIBRATED. TRANSMITTER 483-2065 IS LOB AFT PIT. WILL NEED TEST CABLE 926-3500 FOR QTY ADJ AFTER TXMTR REPLACED. IF UNABLE TO CALIBRATE REPLACEMENT TRANSMITTER, KNOWN FLEETWIDE ISSUE OF INTERIOR TANK DETERIORATION SUSPECTED. TANK PCN 12