Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011032101355Gcu · inoperativeCREW REPORTS APU GEN WILL NOT COME ON LINE. APU GEN INOP PER MEL. REPLACED GENERATOR CONTROL UNIT PER MM. RAN ENGINE. OPS CHECK OK.SDR UALA2011032101354Insulation · damagedELEC GEN OFF APU AUXILIARY POWER BREAKER (APB) OPEN AND AUXILIARY POWER UNIT (APU) GENERATOR RUNNING OR APU GENERATOR SWITCH OFF. LATCHED MSG 24-31663 ON ARRIVAL. ACCOMPLISHED RESET PER FIM, NO HELP. ELECTRIC PAGE SHOWS NIL VOLTAGE AND FREQUENCY. SUSPECT FASDR UALA2011032101356Light · inoperativeONE EA SEAT MOUNTED EMERGENCY EXIT LIGHT IS INOP AT SEAT 2E. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2011032101338Unknown · odorODOR OF OIL COMING FROM AROUND ROW 31. CHECKED AROUND ROW 31 AREA, NO OIL ODOR FOUND WITH APU RUN.SDR UALA2011032101330Unknown · odorPLASTIC BURNING ODOR IN MID GALLEY, ODOR CAME AND WENT AND WHEN IT CAME BACK A SECOND TIME REMOVED PWR FROM GALLEY AND THEN ODOR WENT AWAY PERMANENTLY. RAN ALL OVENS, WARMING OVENS, HOT-PLATES AND CHILLERS NO PLASTIC BURNING OR HOT ODORS. OPENED AND INSPECTESDR UALA2011032101327Light · inoperativeSEAT 3F FWD EEL LIGHT INOP. REPLACED LIGHT ASSY, OPS CHECK NORMAL.SDR UALA2011031801303Windshield · crackedCAPT WINDSCREEN DELAMINATING TOP RIGHT AND ALONG BOTTOM. SAMC TEXT: PER CREW, DELAMINATION AT L1 WINDOW IS 5X3 AND 1X6, DOES NOT AFFECT VISION. NEED TO CHECK PER MM. FOUND CRACKED ALONG TOP EDGE NEXT TO DELAM AREA. REMOVED AND REPLACED WINDSCREEN.SDR UALA2011031601276Light · detachedTHE 1F EMERGENCY LIGHT STRIP ON SIDE OF SEAT COMING OFF. RE-ATTACHED EMERGENCY LIGHT STRIP.SDR UALA2011031601282Wire · disconnectedALL EMERGENCY LIGHTS ZONE 2 AFT INOPERATIVE. FOUND WIRING OUT OF DISCONNECT AT SEAT 9H AND 10C SEAT LIGHT DISCONNECTED AND 10C FOOT GRD WIRE PULLED OUT OF CONNECTOR. REPAIRED WIRING, SYSTEM CHECKED OK.SDR UALA2011031601283Wire Harness · damagedEICAS STATUS MSG FLIGHT CONTROL SYS NOTE. NR 1 SPOILER DOESN'T FULLY STOW. REPLACED ACTUATOR. DURING OPS TEST FOUND RVDT OUT OF RANGE. CHANGED HARNESS, NO HELP. CONTINUING TO T-S. REPLACED PCU NR 1 SPOILER, CHECKED ADJUSTMENTS FELL WITHIN LIMITS IAW AMM.SDR UALA2012031601731Fastener · faultyPYLON ACCESS PANEL 443BL HAS 3 SCREWS AND 3 INDICATORS THAT NEED REPLACING. REPLACED FASTENERS AND REINSTALLED PANEL.SDR UALA2011031601275Tube · leakingNR 9 DRAIN TUBE LEAKING. RAN NR 2 ENG. FOUND NO LEAKS DURING RUN OR AFTER SHUTDOWN.SDR UALA2011031601274Lens · missingDOOR 4R FWD EXIT LENS IS MISSING. REPLACED EXIT LENS 4R.SDR UALA2011031601251Converter · faultyELEC BACKUP SYS BACKUP ELECTRICAL SYSTEM FAILURE. ADVISORY. CREW COMMENTS: BOTH BACKUP GENERATORS RESET MSG-2445001 LATCHD ER MODE MSG-2446090 LATCHD ER MSG-2445480 INACTV ER MODE MSG-2445002 INACTV ER MODE MSG-2445000 INACTV ER MODE INBOUND FLT DECK EFFSDR UALA2011031601250Audio Panel · faultyCAPT'S O2 MASK WILL NOT TRANSMIT. TROUBLESHOOTING REPLACED AUDIO MANAGEMENT UNIT PER MM, NO FIX. RE-INSTALLED ORIGINAL UNIT. RANG OUT WIRES FROM DM23009 TO DM23008AA TO S23001 & TO CAPT PTT ON GLARESHIELD. RANG OUT WIRES FROM AMU TO B23080, M23457 AND TO C2SDR UALA2011031501237Control Valve · faultyEICAS MSG " PACK FCV L " ON STATUS PAGE. MEL COMPLIED WITH MAT MSG: 21-24101 UPPER FLOW CONTROL VALVE LT PACK. REPLACED UPPER FLOW CONTROL VALVE AND OPS CHECKED NORMAL.SDR UALA2011031501233Valve · wornOUTBOARD IP VALVE WORN ON NR 1. REPLACED VALVE. OPS NORMAL.SDR UALA2011031501236Connector · damagedNR 2 ENG FUEL VALVE DID NOT COMPLETELY CLOSE AT SHUT DOWN, STILL SHOWED FUEL FLOW. SUGGEST REPLACING RELAYS K76204 PCN 566-0640 AND K76207 PCN 566-0648. RELAY K76204 REPLACED, NO HELP. FOUND INTERMITTENT CONNECTIONS AT D71074P AND D71024P. REPAIRED CONNECSDR UALA2011031401219Structure · damagedA/C SUSTAINED LIGHTNING STRIKE DAMAGE. REMOVED PAINT FROM ALL AREAS & REPAIRED PER SRM 51-00-01 REPAIR 8.SDR UALA2011031401211Gcu · faultyREPLACED RIGHT GCU.SDR UALA2011031401210Idg · faultyACFT BACK TO GATE DUE IDG MSG.GET MSG 2431662, REF FIM 2 421 TASK 812, RESET SWITCH AND RUN ENG, NO HELP. NOTIFIED DD & MAKE DEF. RIGHT IDG OIL SHOULD BE CHANGED WHEN DEFERRAL IS CLEARED IAW MEL 2411A. REPLACED AND OPS CHECK RIGHT ENG IDG PER MM.SDR UALA2011031401216Engine · smokeREPORTED SMOKE FROM RIGHT ENGINE ON TAKEOFF. CREW DID A VISUAL CHECK FROM CABIN - SAW NOTHING. NOTHING ON DOWNLINKS FROM THE ACFT. ALL INDICATORS IN COCKPIT NORMAL. ALL IN AGREEMENT AT THIS TIME TO MONITOR AND CONTINUE ON TO ORD.SDR UALA2011031401208Electronic Unit · malfunctionedLOWER LOBE REST AREA CONTROL PANEL HAS NO POWER. DEFERRED. LOWER LOBE DEFERRED NOT TO BE USED. CABIN ALL TEST FAULTS OEU M23446 WITH MESSAGE 23-03402. OEU CB AND ZMU CB RESET, NO FIX. ALL TEST AND CABIN OPS SOFTWARE RELOAD CARRIED OUT, NO FIX. FOUND OEU SDR UALA2011031401207Converter · faultyBOTH BACKUP GEN LIGHTS CAME ON SAME TIME. RESET PER CHECKLIST. ALL OK. REPLACED BACKUP GEN CONVERTER PER MM. GROUND CHECKS PASSED.SDR UALA2011031401206Connector · looseSEAT ROW 2E AND 2F ALL 4 EMERGENCY LIGHT INOP. FOUND CONNECTOR LOOSE AT SEAT 2E AND REPLACED LIGHTS AT SEAT 2F, ALL LIGHTS OP CHECK GOOD.SDR UALA2011031401191Engine · crackedNR 1 ENG FOUND RADIAL CRACKS IN AREA "A" OF HPT. CURRENTLY ON INTVL NR 3, RVI PIX POSTED. ENGINE CHANGE REQUIRED. WIDE LOAD CA TRUCK PERMIT NOT AVAIL WEEKENDS. ENGINE ETA 17MAR 1400. OLD ENG OFF. FIREWALL READY FOR ENG. INSTALLED NEW ENGINE.SDR UALA2011031101180Battery Pack · dischargedNR 3L AND NR 3R AISLE EXIT SIGNS INOPERATIVE. REPLACED POWER SUPPLY BATTERY PACK AT LOCATION M33406. OPS CHECKED NORMAL.SDR UALA2011031101179Battery Pack · dischargedNR 3L EXIT SIGN ABOVE DOOR IS INOPERATIVE. REPLACED POWER SUPPLY BATTERY PACK AT LOCATION M33406, OPS CHECKED NORMAL.SDR UALA2011031001165Pin · damagedNR 1 ENG AFT RT CORE COWL RT AFT HOP TIE BAND PIN DAMAGED. INSTALLED NEW PIN. UNIT NOW SERVICEABLESDR UALA2011031001158Bracket · damagedNR 1 ENG AFT RT CORE COWL AFT HOP TIE SUPPORT DAMAGED. REMOVED BRACKET ASSY. INSTALLED BRACKET ASSY.SDR UALA2011031101187Power Supply · inoperativeEMERGENCY LIGHTS AROUND GALLEY BETWEEN DOORS 2L AND 2R ARE INOP. REPLACED POWER SUPPLY M33096 ABOVE DOOR 2L. OPS CHECKED GOOD.SDR UALA2011031001155Filter · contaminated'ENG FUEL FILTER L' EICAS, FLIGHT DIVERTED. STATUS AND ADVISORY MESSAGES CAME ON INTERMITTENTLY, NOT CONTINUOUSLY. REPLACED NR 1 FUEL FILTER AND DPI SWITCH. RAN ENGINE, OPS CHKS NORMAL. NO MESSAGES.SDR UALA2011031001159Fire Bottle · dischargedNR 1 ENG FIRE EXTINGUSHING BOTTLE EICAS MESSAGE AND BOTTLE ENG NR 1 INDICATING LIGHT ILLUMINATED. FOUND NR 1 FIRE BOTTLE DISCHARGED. REPLACED NR 1 FIRE BOTTLE PER MM. OPS CHECKED AND TESTED FIRE BOTTLE SYSTEM PER MM.SDR UALA2011031001157Actuator · faultyDURING A8 CHECK, ACTUATOR CONFIDENCE TEST LEFT WING SHUTOFF VALVE ON P61 VALVE CLOSED LIGHT WILL NOT EXTINGUISH. MAT SHOWS MAINT MESSAGE 27-17019. TROUBLESHOT CHECKED 28VDC POWER AT VALVE AT DV27100 3 AND 2 WITH GROUNDS AT 9 AND 1 AND CASE GROUND AT 8 ALL NOSDR UALA2011030901150Bracket · bentNR 1 ENG FOUND INBD REV V-BAND MILLED BRACKET BENT.SDR UALA2011030901148Hinge Fitting · damagedDOOR 1L UPPER HINGE ASSY CLEVIS ATTACH FTNG SHEARED OFF AT FRAME ATTACH 4 BOLTS, 3 HOLES ELONGATED. INBD UPPER HOLE GOUGED AND EXTRUDED. REMOVED SHEARED BOLTS BLENDED STRESS RISERS. ACCOMPLISHED HFEC INSPECTION PER NDTM. REPLACED NR 1 LT DOORWAY HINGE FITTSDR UALA2011030801133Sign · looseAISLE EXIT LIGHT SUPPORT IS WEARING AND LOOSE ON THE INBD CEILING CONNECTION. REPLACED CROSSAISLE EXIT SIGN PER MM.SDR UALA2011030901147Unknown · leakingFUEL LEAKING FROM NR 11 DRAIN TUBE NR 2 ENGINE (13 DROPS PER MINUTE). NR 2 ENGINE WAS IDLE, RAN FOR 5 MINUTES. INSPECTED DRAIN TUBE 30 MINUTES AFTER SHUT DOWN. NO DROPS NOTED.SDR UALA2011030801125Hydraulic Line · leakingHYDRAULIC PRESSURE SYS C LOW CENTER HYDRAULIC SYSTEM PRESSURE. SYSTEM PRESSURE LESS THAN 1200 PSI. CAUTION MSG01- ACTIVE APPROACH HARD; RESERVOIR (CENTER) FLUID QUANTITY IS LOW. DB- HYDRAULIC INTERFACE MODULE (HYDIM)(CL) MSG-2910150 ACTIVE AP HARD. FOUND INBD SDR UALA2011030701117Light · brokenEMERGENCY LIGHT ON SEAT 3E BROKEN OFF. REPLACED EMERGENCY LIGHT. OPS CHECKED GOOD.SDR UALA2011030701116Coupler · faultyLEFT HF WILL NOT TRANSMIT. REPLACED LEFT HF COUPLER PER AMM. OPS CHECK NORMAL.SDR UALA2011030701122Controller · faultyOPBC L OVERHEAD PANEL BUS CONTROLLER (OPBC) FAULT. STATUS MSG-2348801 ACTIVE MT HARD. REPLACED THE LEFT OPBC PER MM, ACCOMPLISHED MAT TEST, TESTED NORMAL, NO FAULTS.SDR UALA2011030701079Girt Bar · brokenDOOR 1L DIFFICULT TO CLOSE. CHECKED MED 1L FOR PROPER OPERATION. DOOR 1L SLIDE REMOVED FOR ACCESS. REPLACED SLIDE AT DOOR 1L. AFT SLIDE GIRT BAR BRACKET ON DOOR 1L WAS REMOVED ON ACCOUNT IT IS BROKEN. REPLACED BROKEN BAR BRACKET.SDR UALA2011030701078Chain · out of adjustDOOR 1L HARD TO OPEN AFTER ADJUSTING PROG CHAIN. ADJUSTED AS FOLLOWS SHORTENED SHORT CHAIN 2 FLATS LENGTHENED LONG CHAIN 2 FLATS. ADJUSTED PROGRAMMING BOLT AND TESTED CHAIN.SDR UALA2011030701092Light · inoperative1 SEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT 1F IS INOPERATIVE. RELAMPED, OPS CHECKS GOOD.SDR UALA2011030401070Power Supply · inoperativeEMERGENCY FLOOR PROXIMITY LIGHTS INOP RT AISLE BETWEEN DOOR 3R & 4R. REPLACED POWER SUPPLY M33401 REF AMM, OPS CHECKED OKAY.SDR UALA2011030401074Bearing · migratedNR 2 ENG AFT ENG MOUNT CENTER BEARING OF CENTER LINK ASSY. BEARING MIGRATED AFT APPROX 7-16 INCHES. REMOVED AFT MOUNT PER MM. REPLACED NR 2 ENG AFT LOWER ENG MOUNT PER MM. ACCOMPLISHED RII INSPECTION OF NR 2 ENG AFT LOWER ENG MOUNT PER MM. INSTALLATION ISDR UALA2011030401071Cover · missingSEAT 41G AISLE EEL COVER MISSING. REPLACED COVER.SDR UALA2011030401069Spar · corrodedLT WING REAR SPAR WEB CORRODED AROUND FASTENERS BETWEEN IRSS 340 AND IRSS 350 WHERE A FUEL BOOST PUMP IS INSTALLED. REPAIRED IAW 777EN-57-0156.SDR UALA2011030401058Processor · malfunctionedFUEL IMBALANCE LT AND RT MAIN TANK QUANTITIES DIFFER BY A PRE-DETERMINED AMOUNT. 3700 LB IMBALANCE. BALANCED FUEL BY CHECKLIST. ALL SYS NORMAL. CREW REPORTED THE IMBALANCE OCCURRED AFTER THE FUEL WAS USED FROM THE CENTER TANK. THE RT WING WAS LOWER THAN LEFT
Back to Boeing 777-222