Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011030401059Shutoff Valve · unserviceableNR 2 ENGINE OB TVBC INDICATOR PIN MISSING. NR 2 ENGINE OB TVBC VALVE INDICATOR PIN MISSING. REMOVED OB TVBC AIR SHUTOFF VALVE. REPLACED TVBC VALVE PER MM, OPS CHECK GOOD.SDR UALA2011030401057Bulb · defectiveSMOKE FROM LWR CREW REST READING LIGHT ASSY. NR 5 BUNK HAD DEFECTIVE BULB THAT APPEARS TO HAVE CAUSED PROBLEM. ALL LWR REST READ LIGHT BULBS REMOVED. ACCOMPLISHED CHECK PER EVA 80640. BULBS WERE ALREADY REMOVED, UNABLE TO ROUTE REMOVED BULBS TO SFOEG FITZPSDR UALA2011030301040Battery · overheatedBATTERY OVERHEAT STATUS MESSAGE. REPLACED APU BATTERY IAW AMM. APU STARTS OKAY.SDR UALA2011030301039Pressure Switch · leakingFUEL LEAK LEFT INBD AREA NEAR FUEL PUMP BAY AREA. APU DC FUEL PUMP ONLY LEAKING AT PRESS SWITCH WHEN PUMP IS RUNNING. WHEN PUMP IS OFF AND DURING FUELING VERIFIED NO LEAKS OUT OF PUMP.SDR UALA2011030201014Motor · failedFUEL IMBALANCE EICAS, RTFL. REPLACED THE LT CENTER OVERRIDE FUEL PUMP AND LOW PRESSURE SWITCH. ACCOMPLISHED OPS AND LEAK CHECK. REPLACED (M28109) CENTER LEFT OVERRIDE ELECTRONIC CONTROL UNIT. REPLACED FOR PRECAUTIONARY PURPOSES. ACCOMPLISHED FUEL SCAVENGE SDR UALA2011030201030Pressure Switch · faultyHYDRAULIC SYSTEM PRESSURE INDICATION FAULTS. REPLACED 'C' HYD RESERVOIR PRESSURIZATION MODULE AND PRESSURE RESERVOIR PRESSURE SWITCH, NO HELP. ACCOMPLISHED CHECKS PER LM 7807 AND CH1523, C HYD PRESSURE MODULE AND PRESSURE SWITCH S29306 REPLACED. REPLACED COSDR UALA2011030201019Switch · faultyLOSS OF THRUST ASYMMETRY COMPENSATION (TAC) FUNCTION. STATUS MSG01- LATCHED CLIMB MODE DEPENDENT; THRUST ASYM COMP SWITCH IS INVALID. DB- PRIMARY FLIGHT COMPUTER (LEFT) ITEM CNX PER PLF SHOWS NOT ACTIVE MSG-2710807 LATCHED CL MODE. REPLACED THRUST ASYM COMPSDR UALA2011022800989Skin · damagedDOOR 1L SKIN DAMAGED FWD FRAME ADJACENT STOP FTNG 2ND FROM TOP. SUPPLEMENTAL DATA UPDATE SKIN DAMAGE APROX 3.000 IN X 0,535, SEAL MATING FLNG DENTED. NOTE DEFECT HAS 1EA FASTENER DOES NOT MEET MINIMUM E.D. REQUIREMENTS. RMVD DAMAGED SKIN. ACCOMPLISHED HFEC NOSDR UALA2011022800969Feeder Cable · burnedNR 2 ENG. IDG FEEDER CABLE UPPER CONNECTION RED AND YELLOW INSULATION BURNT. REPLACED COLORED IDENTIFIERS.SDR UALA2011022800986Retainer · looseNR 2 NACELLE AFT STRUT FAIRING LOWER HEAT SHIELD SEAL RETAINER HAS 6 LOOSE ATTACHMENT FASTENER. ACCOMPLISHED INTERIM REPAIR REF MT 54-UA1. RE-INSPECT EVERY 3 SERVICE AND PERMANENT REPAIR AT C CHECK. OK TO CF9 PER OPBLM.INTERIM FASTENERS ARE 3,5, 9,11,15, AND SDR UALA2011022500954Duct · brokenLT AND RT HYD EDP INDICATE RUN ALL TIME IN AUTO POSITION. EDP REFERS TO THE ELEC DEMAND PUMPS. THEY WOULD SHUT OFF MANUALLY. MAINT TEXT: RAN AND OPS CKD LT AND RT EDP'S AND ACMP'S, FOUND LT ACMP OPERATED NORMAL, RT ACMP RUNS ALL THE TIME IN AUTO. SWAPPED LSDR UALA2011022400912Module · faultyCABIN AREA CONTROL PANEL AT DOOR 1L IS FAILING TO BOOT AT POWER UP. REPLACED AND TESTED CACP, PANEL OPS CHECKED GOOD.SDR UALA2011022400911Light · inoperativeSEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT 1F IS INOPERATIVE. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2011022400916Sdu · failedSATCOM EICAS. SDU FAILED. TRIED RESET & PERFORMED RUN-INSTALLATION TEST, NO HELP. REPLACED SDU IAW MM. SATCOMM CHECKED GOOD.SDR UALA2011022200900Connector · damagedHIGH PRESSURE (HP) FUEL SHUTOFF VALVE POSITION DISAGREES WITH COMMANDED POSITION. STATUS MSG-7360211 INACTV SD MODE. MAINT MSG 73-60021 PERFORM ED WET MOTOR NOW HELP. PERFORMED WIRE CHECK FOUND HIGH RESISTANCE BETWEEN PLUG D71024P AND D71074J, CLEANED BOTH CSDR UALA2011022200901Wire · shortedWIRE THAT GOES TO PIN NR 2 AT CONNECTOR DS29105 SHORTED TO GROUND SOMEWHERE, GENERATING THE LOW HYD RSVR PSI MESSAGE. WIRE SHORTED TO SHIELD BETWEEN D7180P AND DS29105. DISASSEMBLED AND DEPINNED BOTH CONNECTORS. STARTED REMOVING WIRE W8144-1002-18. UNABLESDR UALA2011022100884Valve · faultyPACK R2 AND TIME UNABLE TO RESET. RT PACK TEMP HIGH CAUSING PACK TRIP OFF. ACCOMPLISHED TROUBLESHOOTING IAW MAINT MSG, SWAPPED RT LOW LIMIT VALVE WITH RT TURBINE BYPASS VALVE IN ORDER TO DISPATCH USING MEL2152AE. REPLACED RT LOW LIMIT VALVE. SWAPPED TURBINESDR UALA2011022100851Circuit Card · faultyHYD RESERVOIR PRESSURE LT STATUS MESSAGE. REPLACED A17 HYD LOW PRESS CARD IAW MM. REPLACED PRESSURE SWITCH. REPLACED A4 HYD DIM CARD.SDR UALA2011022100875Heater · overheatedHAVE ELECTRICAL BURN ODOR AT LAV NEXT TO DOOR 2L. WATER HEATER EXTREMELY HOT, ESPECIALLY IN AREA OF THE ON-OFF SWITCH. SWITCH SELECTED TO OFF, ODOR DISSIPATED SLIGHTLY BUT STILL DETECTABLE. WATER HEATER LAV AT DOOR 2L. HAD ELECTRICAL BURNING ODOR. HEATER SWISDR UALA2011021800845Fuse · faultySEATS 31 TO 43 LT AND RT AISLES, EMERGENCY LIGHTS ON ARMREST ARE INOPERATIVE. REPLACED FUSE IN POWER SUPPLY. OPS CHECKS GOOD.SDR UALA2011022100857Battery · faultyMAIN BATTERY WILL NOT HOLD A CHARGE. REPLACED BATTERY IAW MM. REPLACED BATTERY CHARGER IAW MM. TESTS GOOD.SDR UALA2011021800849Fire Bottle · dischargedLOWER LOBE CREW REST FIRE BOTTLE DISCHARGED. COMPLIED WITH MEL REQUIREMENTS. LOWER LOBE CREW REST UNUSABLE. REPLACED LOWER LOBE FIRE BOTTLE.SDR UALA2011021700823Power Supply · inoperativeEMERGENCY LIGHTS INOP AT DOOR 3L. 1 EXTERIOR LIGHT INOP AND BOTH INTERIOR LIGHTS INOP FWD AND AFT OF THE MED. REPLACED POWER SUPPLIES, TESTS GOOD.SDR UALA2011022100856Connector · damaged"DC STANDBY CARD - A12" IN P310 ELMS PANEL FOR MAINT MSG 24-13037. REPLACED DC STANDBY CARD, NO HELP. FOUND CONNECTOR DM24412B DAMAGED ON DM24412, UPON OPENING UP CONNECTOR DM24412B FOR REPLACEMENT FOUND IMPROPER SPLICE UNDER BACKSHELL HOUSING ONE INCH FROMSDR UALA2011021600799Control Unit · faultyFUELER REPORTS RT WING WILL NOT ACCEPT FUEL. REPLACED FUEL QUANTITY PROCESSOR UNIT IAW MM, NO HELP. RH OTBD REFUEL VALVE MANUEL OVERRIDE FAILED. RT OTBD FUEL VALVE LEAKING AT CONTROLLER. FUEL CAME OUT OF OVERRIDE KNURLED KNOB. RT OTBD REFUEL VALVE CONTROLSDR UALA2011021600806Actuator · leakingNR 2 ENG SVA LEAKING FUEL. COMPLETED INSTALLATION OF ACTUATOR AND DRY MOTOR. CREATED SMC015 TO RUN ENGINE TEST. INFO ON WU K5220F.SDR UALA2011021800846Transducer · faultyEICAS STATUS MESSAGE OF ENG REVERSER L DISPLAYED UPON ARRIVAL. FOUND MAINT MESSAGE 78-51821 T-R POS TRANSDUCER (RT SLEEVE) (LT ENG CHAN B) SIGNAL OUT OF RANGE. DEFERRED. COMPLIED WITH. REPLACED RT SLEEVE RVDT IAW FIM. REVERSER FAILED WITH MSG 78- 61811 (CHASDR UALA2011021600805Rod End · missingLEFT INBD AFT FLAP OTBD DRIVELINK FWD ATTACH ROD END MISSING. REF OV WU T6290X. REPLACED LT INBD AFT FLAP OTBD DRIVE ROD ASSY AND ADJUSTED IAW MM. ACCOMPLISHED BY MECHANIC. ALSO, THE BELLCRANK ASSY WAS REPLACED IAW MM AND THE T/E FLAP WAS ADJUSTED IAW MM.SDR UALA2011021600804Skin · dentedSKIN DAMAGE NOTED ON DEPARTURE WALK AROUND FWD OF DOOR 4R. ACCOMPLISHED CLEAN UP FOUND DENT BEYOND LIMITS OF DETAIL DENT DEPTH .150 INCH AFTER CLEAN UP NO GAUGES OR SCRATCHES. ACCOMPLISHED DIE PENETRANT CHECK, NO CRACKS NOTED AND DAMAGE COMPLIANT WITH SRM. SDR UALA2011021600803Sync Lock · malfunctionedRT ENGINE THRUST REVERSER CONTROL SYS FAULT. STATUS MSG01- NOT ACTIVE TAXI IN INTERMITTENT; THRUST REVERSER SYNC LOCK (RT SLEEVE) (RT ENG) IS NOT IN COMMANDED POSITION. DUE TO PREV HISTORY, DEACTIVATED RT ENG REVERSER IAW MEL 7831A. REPORTING MMSG 78-00092SDR UALA2011021500793Controller · faultyBLEED FAMV L LT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED OR LT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG01- LATCHED APPROACH MODE DEPENDENT; FAN AIR MODULATING VALVE (LT) TORQUE MOTOR CIRCUIT IS OPEN OR SHORTED. SDR UALA2011021400782Actuator · stuckAPU VALVE STUCK IN OPEN POSITION. DEACTIVATED APU FUEL SHUTOFF VALVE IN THE CLOSED POSITION. DF-38 IS IN CONJUNCTION WITH THIS DEFERRAL. REPLACED APU FUEL SHUTOFF ACTUATOR. OP CHECKED NORMAL.SDR UALA2011021500794Drive Assy · inoperativeWEATHER RADAR FAIL BOTH RADAR SYS INOPERATIVE. REPLACED DRIVE ASSY, BOTH SYS PASS MAT TEST.SDR UALA2011021400774Video Unit · faultyALL VIDEO MONITORS ARE OFF LINE AND WILL NOT RESET. VIDEO INTERFACE UNIT ON ORDER. REPLACED VIDEO INTERFACE UNIT AND RECYCLED VIDEO MONITORS CB, NO HELP. NEED MORE TROUBLESHOOTING. REPLACED VIU, OPS CHECK OK.SDR UALA2011021400772Rub Strip · damagedNR 1 ENGINE ATTRITION LINER AT 6 O'CLOCK POSITION FILLER REPAIR, BREAKING LOOSE. APPROX 3"X 2". ON WALK AROUND FOUND NR 1 ENG RUB STRIP AT APPROX 6 O'CLOCK POSITION DAMAGED. DAMAGE IS WITHIN THE RUB STRIP INNER LAYER, MEASURING 3.5 INCHES WIDEST AREA. FAN RUSDR UALA2011021400786Processing Unit · inoperativeFUEL IMBALANCE LT AND RT MAIN TANK QUANTITIES DIFFER BY A PRE-DETERMINED AMOUNT. REPLACED FUEL QTY PROCESSOR UNIT (FQPU) IAW MM. REPLACED FUEL TANK UNIT (18L) IAW MM.SDR UALA2011021400785Converter · faultyELEC BACKUP SYS STATUS. DUE TO REPETITIVE REPORTS OF 'ELEC BACKUP SYS' STATUS MESSAGE WITH CORRELATED MESSAGE. IF NO FAULTS NOTED, REPLACE BUG CONVERTER (M24008) PCN 566-9012 & IF NECESSARY, CCB (K24202) PCN 566-0547. IAW MM REPLACED WITH NEW BUG CONVERTER & SDR UALA2011021400775Fseu · faultyFLAP-SLAT CONTROL 2 HIGH LIFT CONTROL LANE NR 2 HAS A FAULT. STATUS MSG-2720722 LATCHED ER MODE MSG-2720722 LATCHED ER MODE. REPLACED FSEU NR 2 IAW MM, CHECKED OK.SDR UALA2011021400763Oxygen Mask · unwanted deployO2 MASKS ABOVE 3HJ DROPPED DOWN. REPACKED MASKS AND SECURED COMPARTMENT DOOR CLOSED AND LATCHED.SDR UALA2011021400781Probe · faultyFUEL TRANSFER WHEN NOT COMMANDED. CTR TANK SCAVENGES EARLY AND ONLY TO LT MAIN TANK. APPROX 40,000 LBS IN THE WING TANKS, WHEN SCAVENGING STARTED, SUSPECT LT OUTLET FLOAT VALVE POSSIBLY OPENS TOO EARLY. NO TIME TO ACCOMPLISH TEST PER FIM. NO FAULTS FOUND OUSDR UALA2011021000697Lamp · inoperativeDOOR 2R EXTERIOR EMERGENCY LIGHT INOP. RELAMPED, OPS GOOD.SDR UALA2011021100729Pump · faultyC1 ADP NOISY-VIBRATING, AND IS LEAKING OIL. ALL OTHER REQUIRED SYS OPERATE NORMAL. PUMP SWITCH SELECTED OFF. NO ASSOCIATED EICAS. PUMP C1 IS CONSIDERED INOP. REPLACED C1 AIR-DRIVEN PUMP ASSY. PROBLEM STILL EXISTS. NEW PUMP INOP, MX MSG 29 -11020. ONCE RSDR UALA2011021000698Valve · stuckNO WATER PRESSURE, FLIGHT DIVERTED. SUPPLEMENTAL DATA UPDATE THIS FIRST REVENUE FLT SINCE ACFT IN FOR PAINT SCHEME. WATER SYSTEM WAS DRAINED DURING PAINT VISIT. PLEASE CHECK FWD AND AFT FILL VALVES FOR CORRECT CLOSURE. FREED OVERFLOW VALVE, OPS GOOD.SDR UALA2011021000700Controller · failedTRIM AIR PRSOV LT TRIM AIR PRESSURE RELIEF SHUTOFF VALVE (PRSOV) FAILED. STATUS MSG01- NOT ACTIVE TAXI OUT MODE DEPENDENT; TRIM AIR PRESSURE REGULATING AND SOV (LT) TORQUE MOTOR IS NOT IN COMMANDED POSITION. DB- CABIN TEMPERATURE CONTROLLER (L CHAN1) MSG-21SDR UALA2011021100747Apu · leakingOIL ODOR IN CABIN. DUE TO OIL ODOR IN CABIN BOROSCOPE APU LOAD COMPRESSOR AND LOOK FOR SIGNS OF OIL LEAKAGE. ACCOMPLISHED BOROSCOPE INSPECTION OF APU LOAD COMPRESSOR. EVIDENCE OF OIL LEAKAGE AND COKING. REPLACED NR 2 ENGINE, APU, LT ACM AND LT HEAT EXCHANGERSDR UALA2011021000701Pcu · leakingLT INBD FLAPERON PCU LEAKING BEYOND LIMITS. REPLACED LT INBD FLAPERON POWER CONTROL UNIT IAW MM. UNIT WITHIN TOLERANCE.SDR UALA2011021000699Connector · dirtyPACK MODE L. FAULTED LOW LIMIT VALVE LEFT PACK. V21533, WOULD NOT CLEAR. CLEANED LOW LIMIT VALVE CONNECTOR AND CYCLE VALVE, CHECKED VALVE OPERATION AND INDICATION NORMAL, LT PACK OPERATION NORMAL.SDR UALA2011021000712Unknown · odorPOSSIBLE ELECTRICAL ODOR ABOVE LAV 133. INSPECTED AREA AROUND LAV AT DOOR 3 LT AND NO OBVIOUS INDICATIONS OF ELECTRICAL ODOR, CREW REPORT ODOR CLEARED DURING TAXI.SDR UALA2011020800672Skin · delaminatedLT OTBD FLAP DELAMINATED. LOWER SURFACE APPROX 8" X 5". 15" FROM T/E AND 48" INBD EDGE. ACCOMPLISHED PERMANENT LAY-UP REPAIR.SDR UALA2011021000705Valve · faultyRT FUEL JETT NOZZLE VALVE FAILS TEST IN OPEN POSITION. VALVE TESTS GOOD IN CLOSED POSITION. REMOVED AND STARTED INSTALLATION OF RT FUEL JETT NOZZLE VALVE ACTUATOR. COMPLETED INSTALLATION, NEW VALVE NO HELP. SUSPECT VALVE IS BOUND UP AND STIFF.
Back to Boeing 777-222