Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010102904020Connector · shortedELECTRICAL PROBLEMS IN CABIN. FOUND OEU ZONE 1 TXFR BUSS CIRCUIT BREAKER POPPED ON P110 PANEL. TRIED TO RESET- HEARD LOUD BUZZ & SAW FLASH COME FROM L1 DOOR OVERHEAD PANEL. LOWERED PANEL. FOUND CHARRED WIRE BUNDLE. DISCONNECTED ALL CONNECTORS GOING TO L1 DOOR SDR UALA2010102803978Lamp · inoperativeEXTERNAL EEL LIGHT BY DOOR 3R IS INOP. RELAMPED. CHECKS GOOD.SDR UALA2010102803977Light · inoperativeAFT EMERGENCY LIGHT ON MID GALLEY WALL BY DOOR 2R INOP. REPLACED LIGHT ASSY. CHECKS GOOD.SDR UALA2010102803976Connector · unsecureSEAT 3F AFT EMERGENCY LIGHT INOP. SECURED CONNECTORS. CHECKS GOOD.SDR UALA2010102803975Lamp · inoperativeEMERGENCY EXIT SIGN AT DOOR 2R IS INOP. RELAMPED. CHECKS GOOD.SDR UALA2010102904021Converter · faultedSTATUS MSG ELEC BACKUP SYS DISPLAYED IN FLT. FOUND MX MESSAGE 24-48801, OCCURRED AT ENGINE START AND IN CRUISE. REPLACED BACKUP GENERATOR CONVERTER.SDR UALA2010102603962Oxygen Mask · missingMISSING 2 O2 MASKS STOWAGE COMPARTMENTS 502 AND 109. MASKS MISSING AT COMPTS 109 AND 502. NEW MASKS INSTALLED.SDR UALA2010102603958Converter · faultyOIL ODOR IN COCKPIT WITH APU AND PACKS ON. RAN BOTH PACKS WITH APU AND WITH LT PACK TRIM AIR SELECTED FULL HOT, AFTER REPLACING LT PACK OZONE CONVERTER. NO OIL OR FOUL ODORS AT THIS TIME. BORESCOPED APU DUCTS AND LT PACK ALSO AND NO EVIDENCE OF OIL.SDR UALA2010102503936Engine · faultyAPU AUTO SHUTDOWN ON START. UNABLE TO GET APU BACK ON LINE. REPLACED APU. OPS GOOD.SDR UALA2010102503938Idg · faultyCREW REPORTS EICAS MAINT PAGE SHOWING LEFT IDG FILTER AS "BLOCKED". AHM PROGRAM SNAPSHOT SHOWS IDG IS OPERATING NORMAL, AC-V 115, FREQ 400, LOAD .36. DISCONNECTED LT IDG. MAINT REPORTED THE DPI INDICATOR WAS EXTENDED, REPLACED NR 1 IDG PER MM. FILTER CHECK HADSDR UALA2010102503937Controller · faultyAPU CONT STATUS MESSAGE. REPLACED APU CONTROLLER, TESTS OKAY. MESSAGE CLEARED.SDR UALA2010102603959Cone · leakingHAZE SEEN IN F/C, FLIGHT DIVERTED. REMOVED NR1 ENG INLET CONE AND INSPECTED FOR OIL. FOUND INSIDE OF HUB & CONE WET WITH OIL. REINSTALLED INLET CONE. R & R ENGINE.SDR UALA2010102503929Shutoff Valve · faultyCREW REPORTS LT BLEED FAULT. STATUS PAGE INDICATES LT BLEED PRSOV. NEED TO INOP LT BLEED SYSTEM. ACCOMPLISHED NR 1 ENG PRSOV HEALTH CHECK. VALVE FAILED TO OPEN, CAPPED PRESSURE LINE, MUSCLE PRESSURE APPLIED NO LEAKS FOUND. REPLACED PRSOV. ACCOMPLISHED ENG RUNSDR UALA2010102503947Light · inoperativeEMERGENCY EXIT LIGHTS ARE OUT ON ENTIRE PLANE. PER INBOUND CABIN CREW ON FLIGHT 748-23. EMERGENCY LIGHTS OK, NO SMOKING OUTBOARD LIGHTS INOP, EACH CABIN SECTION WALL NO SMOKING LIGHTS OK. EMERGENCY LIGHTS CHECK NORMAL . NO SMOKING LIGHTS OPERATE NORMAL. NFF.SDR UALA2010102503945Insulation · saturatedINSULATION BLANKETS IN BELLY AFT PIT FAILED INSPECTION. REPLACED WET INSULATION BLANKETS AS REQUIRED.SDR UALA2010102203916Light · inoperativeEMERGENCY LIGHT AT MID GALLEY FLOOR LEVEL RT FRONT IS OUT. REPLACED EMERGENCY LIGHT MID GALLEY FLOOR LEVEL RT FRONT. CHECKS OK.SDR UALA2010102203917Lamp · inoperativeEMERGENCY LIGHT AT SEAT 12F AFT IS OUT. RELAMPED EMERGENCY LIGHT AT SEAT 12F. CHECKS OK.SDR UALA2010102103890Oven · smokeWARMING OVEN - SMOKING. DIRTY. CLEANED OVEN R32. OK FOR SERVICE.SDR UALA2010102203909Heater · failedHEAT PITOT L LOSS OF LEFT PITOT HEAT. STATUS MSG-3036121 INACTV CL MODE. SUPPLEMENTAL DATA UPDATE DEFERED FOR TIME AND TROUBLESHOOTING. STATUS AND ADVISORY MESSAGE COMES ON DURING INITIAL CLIMB AND THEN EXTINGUISH. CLEAR MESSAGE, BUT ITEM DEFERRED BECAUSE OF HSDR UALA2010102203912Oxygen Bottle · reads lowCREW OXYGEN READ 1640 PSI. LESS THAN LIMIT AS REQUIRED NR 3SVC CK. REPLACED OXYGEN BOTTLE. OPS & LEAK CHECKED , NO LEAK FOUND.SDR UALA2010102203900Generator · faultyELEC BACKUP GEN LT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP. STATUS MSG01- NOT ACTIVE CRUISE MODE DEPENDENT; BACKUP GENERATOR (L) TEMPERATURE IS HIGH. DB- BACKUP CONVERTER MSG02- ACTIVE CRUISE MODE DEPENDENT; BACKUP GENERATOR (L) TEMPERATURE IS HIGH. MSGSDR UALA2010102103892Oil Cooler · leakingNR1 ENG OIL LOSS. ACP OIL SERVICE FOR NR1 ENG BETWEEN 0.5 AND 1.5 HOUR AFTER ENGINE SHUTDOWN (ON ARRIVAL). ONCE AMOUNT OF OIL ADDED IS DETERMINED NEED TO ACCOMPLISH OIL SVC ASAP. SERVICED NR1 ENG OIL. 15 QUARTS ADDED. REPLACED NR 1 ENG NR 4 BEARING COMPARTMENSDR UALA2010102103891Light · unsecureEXIT ROW LIGHTING AT 1F, IS FALLING OFF. RESECURED EMERGENCY EXIT LIGHT AT SEAT 1F. OK FOR SERVICE.SDR UALA2010102003885Shutoff Valve · faultyTRIM AIR PRSOV LEFT TRIM AIR PRESSURE RELIEF SHUT OFF VALVE (PRSOV) FAILED. STATUS MSG-2124201 INACTV TA MODE. REPLACED LT TRIM AIR PRESSURE RELIEF VALVE, OPS CHECKED GOOD.SDR UALA2010102003883Controller · faultyAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF 1 629 CHANNEL. STATUS MSG-4911970 INACTV ER MODE. REPLACED APUC, GROUND CHECK NORMAL.SDR UALA2010102003882Shutoff Valve · faultyRT PACK WON'T SHUTOFF. REPLACED LOWER RT PACK SOV.SDR UALA2010102003884Sdu · intermittentSATCOM INTERMITTENT. LOG ON WITH INTERMITTENTLY ON ARRV, RERACK RFU, REPLACED SDU AGAIN AND OPS CHECKED NORMAL.SDR ASMF201010007Sensor · damagedACFT PERFORMED AN UNSCHEDULED LANDING, DUE TO DURING CLIMB THE ENG OIL FILTER SENSOR AND ENG OIL FILTER LIGHTS TURNED ON AND DURING CRUISE THE EICAS MESSAGE ENG OIL FILTER WAS SHOWN. THE FLIGHT CREW PERFORMED THE QRH 7.20 PROCEDURE, CONFIRMING THE FAILURE. DURSDR UALA2010102103894Controller · leakingBLEED PRSOV LIGHT STATIS MESSAGE ON TAXI OUT. SNAPSHOT SHOWS HI PRESSURE SOV CLOSED AT IDLE. BLEED OFF ENG-LT MESSAGE AND OFF LIGHT ILLUMINATED IN BLEED SWITCH. CYCLED SWITCH, NO HELP. ACCELERATED TO APPROX 50 PERCENT, N1 NO CHANGE. DUCT PRESS IS ZERO. LT BLESDR UALA2010102003886Light · unsecureSEAT 1E EMERGENCY LIGHT HANGING FROM SEAT. RESECURED EMERGENCY LED LIGHT ON SEAT 1E. OK FOR SERVICE.SDR UALA2010102003879Fan · failedSMELLED ELECTRICAL ODOR BRIEFLY. THEN SAW STATUS MESSAGE EQUIP COOLING FAN RT. ON ARRIVAL, FOUND NO ODOR AND MESSAGE 21-14022. CHECKED AREA BY COOLING SUPPLY FAN, FOUND NO DAMAGE OR DEFECT. C/B COLLARED AND DISCONNECTED CONNECTOR PER MEL. REPLACED R-EQ COOLINGSDR UALA2010102003887Light · looseSEAT 3F EMERGENCY LIGHT LOOSE. SECURED EMERGENCY LIGHT AND OK.SDR UALA2010101903875Generator · faultyIMMEDIATELY AFTER TOUCHDOWN, ELEC BACKUP SYS EICAS MESSAGE. ABLE TO UNLATCH AND CLEAR STATUS MESSAGE, HOWEVER DUE TO LONG HISTORY DF PER MEL 2425A AS PRECAUTION. PER FIM 24-25 TSK 802, AFTER BU CONVERTER AND RT BUG REPLACEMENT, NEXT STEP TO REPLACE LEFT BUG, PSDR UALA2010102003880Cover · crackedEMERGENCY LIGHT COVER AT 3F, 5E AND 5F CRACKED. REPLACED EMERGENCY LIGHT COVERS,SDR UALA2010101903871Unknown · odorLOWER LOBE CREW REST AREA HAS BURNING PLASTIC ODOR WHEN FIRST ENTERED, DISSIPATED, AIR ENTERING AREA HAS NO ODOR, CREW SHUTOFF ENTRY LIGHTS, AND HEATER OFF. ACCOMPLISHED CHECK OF AREA UNABLE TO DUPLICATE ODOR, AS PER FLT CREW VERBAL SUSPECT ODOR TO BE THAT OFSDR UALA2010101903862Generator · inoperativeCREW REPORTED BACKUP GEN TRIPPED OFFLINE TWICE DURING TAXI IN. MX CONTACTED, CHECKED THE CONVERTER AND FOUND CONDITION NORMAL. HOWEVER DUE TO HISTORY, ITEM TRANSFER TO MEL IAW 2425A. REPLACED NR2 ENGINE BACKUP GENERATOR AND ACCOMPLISHED BUG TEST.SDR UALA2010101803835Precooler · crackedNR 2 ENGINE PRECOOLER SPLIT OPEN AT BOTTOM. NR 2 PRECOOLER FOUND CRACKED DURING A CHECK INSPECTION. REMOVED CRACKED PRECOOLER. INSTALLED PRECOOLER. OKAY FOR SERVICE.SDR UALA2010102003881Engine · making metalDURING T-S FOR MAINTENANCE MESSAGE 49-07950 APU SPEED DROOP, FOUND LARGE AMOUNTS OF METAL ON GEARBOX CHIP DETECTORS. REMOVED APU. NEED TO COMPLETE INSTALLATION OF APU. COMPLETED INSTALLATION OF APU.SDR UALA2010101903861Relay · faultySTBY ELEC SYS STATUS MESSAGE WITH MAINT MESSAGE 24-13038. WHILE TROUBLESHOOTING PROBLEM, FOUND THAT MESSAGE WOULD GO AWAY AFTER RELAY K24016 TAPPED ON. MESSAGE REAPPEARS AFTER ACCOMPLISHING STANDBY POWER TEST. REPLACED RELAY K24016, OPS CKS OK.SDR UALA2010101803853Light · dislodgedSEAT 3F FWD EMERGENCY LIGHT FELL OUT OF SIDE PANEL. SECURED EMERGENCY LIGHT TO SIDE PANEL.SDR UALA2010101803854Valve · inoperativeBLEED FAMV RT STATUS MESSAGE RT ENGINE FAMV INOPERATIVE, LOCKED OPEN. REPLACED FAN AIR VALVE, RAN ENGINE AND OPS CHECKS GOOD.SDR UALA2010101803845Oven · faultyOVEN R31 STARTED TO OVERHEAT DURING THE PREPARATION OF THE MEAL SERVICE, EMITTED AN ELECTRICAL ODOR FLIGHT ATTENDANT SHUT OVEN DOWN IMMEDIATELY AND PULLED THE CIRCUIT BREAKER FOR THAT OVEN. REMOVED OVEN. CHK'D EVIDENCE OF ODOR FOUND NONE. DEACTIVATED OVEN PER SDR UALA2010101803858Converter · faultyBACKUP CONVERTER FAILURE. ACCOMPLISHED ALL WIRE CHECKS, NO DEFECTS FOUND. REPLACED CONVERTER, GROUND TEST AND ENG TEST PASS, NO STATUS MESSAGE.SDR UALA2010101803860Oil System · emptyAPU AUTO SHUT DOWN AFTER ENG START. OIL QTY READING LOW. PERFORMED VISUAL CHECK AT APU. FOUND NO OIL QTY IN SIGHT GAUGE AND MCD AND SCAVENGE CD HAVE METAL ON THEM. REPLACED APU, OPS CHECK GOOD.SDR UALA2010101803837Coffeemaker · sparksCOFFEE MAKER - SMOKING OR SPARKING M31. CLEANED ELECTRICAL CONNECTOR AND REPLACED COFFEE MAKER M31. OPERATION CHECKED OKAY. NO EVIDENCE OF BURN BEHIND COFFEE MAKERS.SDR UALA2010101803859Transceiver · faultyRH HF INOPERATIVE. TRANSCEIVER FOUND DEFECTIVE. RH HF TRANSCEIVER REPLACED & OPS TEST OKAY.SDR UALA2010101803842Fan · faultyBURNING ODOR IN CABIN, FLT DIVERTED. INSPECTED CABIN FOR SOURCE, RAN ENG ENGS AND PACKS, OPERATED RECIRC AND GASPER FANS, OPERATED LIGHTS, CHECKED LAVS AND LOWER LOBE. CHECKED CARGO BULK VENT FAN AN D E&E. DEFERRED ENG CARGO VENT FAN. NO OTHER DEFECTS FOUND. SDR UALA2010101803836Connector · unsecureDOOR 1L EMERGENCY LIGHTS COME ON INTERMITTENTLY. DOOR 1L FWD BATTERY PACK MODULE TURNS ON LIGHTS WHEN HANDLED. NEEDS NEW BATTERY PACK MODULE. RESEATED AND SECURED CONN D3101P AT MED 1L THRESHOLD PANEL. EMERGENCY LIGHTS OP CKD GOOD.SDR UALA2010101503826Oven · inoperativeOVEN R52 IN AFT GALLEY INOP. ODOR OF ELECTRIC SMOKE. INBOUND CREW REPORTED, ODOR BUT NO SMOKE. FOUND CIRCUIT BREAKER NOT TRIPPED. CLEANED SAUCE. OVEN R25 CHECKED WITH RUNNING FOR 20MIN, OPS NORMAL, NO ODOR.SDR UALA2010101503822O-Ring · leakingWHILE PERFORMING LEAK CHECK OF THE FUEL OIL COOLER, FOUND OUTLET MANIFOLD ASSEMBLY (LOCATED ON THE TOP OF THE COOLER) AND THE FUEL-OIL COOLER BYPASS VALVE (LOCATED ON THE BOTTOM OF THE COOLER) LEAKING OIL. RPL'D SEAL PLATE ON FUEL OIL BYPASS VLV. REPLACED O-R
Back to Boeing 777-222