What was found
SMELLED ELECTRICAL ODOR BRIEFLY. THEN SAW STATUS MESSAGE EQUIP COOLING FAN RT. ON ARRIVAL, FOUND NO ODOR AND MESSAGE 21-14022. CHECKED AREA BY COOLING SUPPLY FAN, FOUND NO DAMAGE OR DEFECT. C/B COLLARED AND DISCONNECTED CONNECTOR PER MEL. REPLACED R-EQ COOLING FAN, MAT GROUND TEST PASSED, OPS NORMAL, NO FAULTS, NO LEAKS. NOTE: REMOVED FAN WAS CONFIRMED BURNED INTERNALLY.