Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009081402495Light · brokenEMERGENCY PATH LIGHT AT 18G BROKEN. REPLACED ASSY.SDR UALA2009081402496Valve · malfunctionedON ARRIVAL FOUND STATUS MESSAGE L ENGINE FUEL APR VALVE. REPLACED LEFT ENGINE FUEL SPAR VALVE PER MM 28-22-02. PARTS LOAN FROM AMERICAN AIRLINE P/N 20A1001-1 SN T39832.SDR UALA2009081302478Slide · faultyNR 4L MED SLIDE RELEASE HANDLE LOOSE. REMOVED AND INSTALLED NEW SLIDE AND RAFT ASSEMBLY.SDR UALA2009081302491Probe · faultyFUEL QUANTITY INDICATION ON EICAS DISPLAY - FLUCTUATES. CREW COMMENTS: FUEL QTY FLUCTUATES 2000 POUNDS. PERFORMANCE PAGE SHOWS CALC FUEL. RIGHT FUEL QTY SENSOR 19 SHOWS 0.0 SENSOR 18 SHOWS 8.6 SENSOR 20 SHOWS 0.7 RIGHT FUEL QTY INOP TOTAL FUEL QTY ALSO INOSDR UALA2009081302490Shutoff Valve · malfunctionedBLEED PRSOV R STATUS MSG. DUE TO FLIGHT CREWS & AHM REPORTING 'BLEED PRSOV R' STATUS MESSAGE WITH CORRELATED MMSG PRSOV REPLACED. PAID PARTICULAR ATTENTION TO CONDITION OF SENSE LINES FOR LOOSENESS OR DAMAGE. FOUND NO DEFECTS OF LOOSE LINES. REPLACED PRSOSDR UALA2009081302477Skin · damagedTWO (2EA) HOLES IN LT FUSELAGE BETWEEN STA 1937L AND STA 1958L AND STR 40L AND STR 41L. OPENED INSIDE AREA FOR INSPECTION AND ACCOMPLISHED HFEC OF AREA NO DAMAGE TO STRINGERS OR SHEAR TIES. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND LAID OUT RIVET PATTERSDR UALA2009081302473Controller · malfunctionedNR 2 ENG HP FAC CONTROLLER - INOPERATIVE. REPLACED HIGH PRESSURE FAC CONTROLLER AND TESTED GOOD.SDR UALA2009081102458Control Valve · faultyUPPER RT PACK FCV MSG ON STATUS PAGE AND LATCHED ON MAT. UPPER VALVE LOCKED CLOSED. REMOVED AND REPLACED RIGHT PACK FCV. OPS CHECKED GOOD AND MESSAGE CLEARED.SDR UALA2009081102456Lens · missingDOOR 2L EMERGENCY EXIT SIGN MISSING LENS COVER, REPLACED. EMERGENCY EXIT LIGHT OPS CHK CARRIED OUT SATISFACTORY.SDR UALA2009081102455Indication Sys · inaccurateFUEL QTY INDICATION FUEL TANK QUANTITY ACCURACY IS UNACCEPTABLE. STATUS MSG-2412250 ACTIVE ER MODE MSG-2411111 ACTIVE ER INTER MSG-2820150 ACTIVE ER INTER MSG-2820150 ACTIVE ER HARD. REPLACED FQPU AND LOADED SOFTWARE, OPS GOOD.SDR UALA2009081002440Panel · damagedELECTRICAL PANEL EXPOSED IN FORWARD LAV. FOUND MOTION DETECTOR IN FWD LAV DAMAGED BY PAX. REPLACED MOTION DETECTOR AND OPS CHECKS OK.SDR UALA2009081002431Battery · faultyBATTERY CHARGER MSG LWR EICAS. REPLACED MAIN AC BATTERY. EICAS MSG CLEARED UP & BATTERY CHARGING OKAY.SDR UALA2009081002407Pca · faultyFLIGHT CONTROL SYSTEM STATUS MESSAGE. UNABLE TO RESET. REPLACED AILERON PCA & PRIMARY FLIGHT CONTROL, CHECKED OKAY. OPS SOFTWARE LOADED, ALL MAT TESTS PASSED.SDR UALA2009080702404Circuit Card · failedFIRE LOOP 2 ENG L LEFT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01- ACTIVE CLIMB HARD; FIRE LOOP 2 (LEFT ENGINE) IS OPEN. DB- ENGINE FIRE DETECTION CARD (LEFT) MSG02- ACTIVE CLIMB HARD; FIRE LOOP 2 (LEFT ENGINE) IS SHORTED. DB- ENGINE FIRE DESDR UALA2009081002428Light · unsecureSEAT 1E EMERGENCY LIGHT ON AISLE KEEPS HANGING DOWN. LIGHT STRIP FIXED ON SIDE.SDR UALA2009081002427Lamp · inoperativeEMERGENCY LIGHT IS INOP AT SEAT 8D AFT POS. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR UALA2009080602385Engine · surgesENGINE HAD A SILENT SURGE.SDR UALA2009080502369Controller · failedASCP PRIMARY CTRL L LEFT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILED. REPLACED LEFT AIR SUPPLY CABIN PRESSURE CONTROLLER.SDR UALA2009080502368Apu · malfunctionedAPU WILL NOT START. APU HAS HISTORY OF 'APU CONTROL' EICAS MSG WITH NO FAULTS FOUND AND PREVIOUS PARTS REPLACED STARTER, I-O CARD, AND RELAY K49002. NO HELP. REPLACED APU.SDR UALA2009080502349Satcom · faultySATCOM STATUS MSG NO PROMPT ON PANEL DISPLAYED. REPLACED SDU, SYSTEM CHECKS OKAY.SDR UALA2009080302320Light · inoperativeTWO (2) EMERGENCY LIGHTS INOPERATIVE, DIRECTLY ACROSS FROM DOOR 4R ON GALLEY WALL. REPLACED LIGHT ASSY, LIGHTING TEST OKAY.SDR UALA2009080302331Generator · faultySTATUS MSG - 'ELEC BACKUP GEN R' DISPLAYED. WILL NOT RESET. REPLACED BACK UP GENERATOR, OPS GOOD.SDR UALA2009080302328Shutoff Valve · faultyRIGHT ENGINE DUCT PRESSURE FLUCTUATES 20 PSI IN CLIMB NORMAL REST OF TIME. REPLACED HPSOV. NR 2 ENG IDLE RUN AND OPS CHECK ACCOMPLISHED; OPS CHECK OKAY.SDR UALA2009080302327Module · failedACE MONITOR CHECK FAILED PER 3 SERVICE. FOUND FAULTY MODULE. REPLACED LEFT AIMS MODULE 1 AND LOADED SOFTWARE; MESSAGE CLEARED.SDR UALA2009080302306Idg · faultyEICAS MSG IDG FILTER DISPLAYED, FOUND RED DELTA P POPPED ON IDG. REPLACED RIGHT ENGINE IDG AND RAN ENG. OPS CHECKS OKAY.SDR UALA2009080302308Light · inoperativeEXTERIOR EMERGENCY LIGHT INOP AT DOOR 4R. REPLACED LAMP, OPS CHECKED OK.SDR UALA2009080302307Light · inoperativeEXTERIOR EMERGENCY LT INOP AT DOOR 4L. REPLACED LAMP, OPS CHECKED OK.SDR UALA2009073002286Oil System · overservicedNR 2 ENG OIL CONSUMPTION EXCEEDS LIMIT. NO HISTORY OF HOC, OIL HIDING, OR HIGH OIL TEMP. NO EVIDENCE OF OIL LEAK IN INLET OR EXHAUST. RAN ENG 2 AND CHECKED FOR EXTERNAL LEAKS. NO LEAKS NOTED AND NO LEAKS FROM ENG DRAINS. AFTER 30 MINS, REMOVED OIL CAP ANDSDR UALA2009072902283Coupler · faultyLEFT HF CAN BE TUNED AND RECEIVED BUT ONLY TUNING SQUEAL HEARD WHEN ATTEMPTED. MAINT MESSAGE 23-51010 LEFT COUPLER HAS INTERNAL FAULT. REPLACED COUPLER. GROUND CHECKED OK.SDR UALA2009072902282Accelerometer · inoperativeENG VIB MONITOR R RIGHT ENGINE AIRBORNE VIBRATION MONITORING (AVM) SYSTEM IS INOPERATIVE, OR LOSS OF TACHOMETER DATA. STATUS MSG-7706042 INACTV ER INTER -MAT MSG. 77-06042 INTERMIT. IN CRUISE. -INF- :MSG 77-06042 E-FLANGE ACCELEROMETER FAULT HIT AT HIGH INSDR UALA2009072902281Controller · malfunctionedAPU APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPS, OR COMPLETE LOSS OF APUC BUSS ACTIVITY (BOTH L & R 629) FOR 3 SECONDS AFTER APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDS. STATUS MSG01- NOT ACSDR UALA2009072802265Exciter · failedENG IGNITER L2 LEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; IGNITION SYSTEM NR 2 (L ENG) FAILED TO LIGHT ENGINE. DB- ELECTRONIC ENGINE CONTROL (L ENG, CH B) MSG-7461501 INACTV ES MODE. REPLACED EXCITERSDR UALA2009072802243Light · inoperativeSEAT 3F FWD EMERGENCY LIGHT INOPERATIVE. INSTALLED NEW EMERGENCY LIGHT, OPS CHECKS GOOD.SDR UALA2009072802242Light · inoperativeSEAT 2F AFT EEL LIGHT INOPERATIVE. REPLACED LAMP ASSY, OPS CHECK NORMAL.SDR UALA2009072802241Light · inoperativeSEAT 1F AFT EEL LIGHT INOPERATIVE. REPLACED LAMP ASSY, CHECK NORMAL.SDR UALA2009072802240Light · inoperativeSEAT 3E AFT EEL LIGHT INOPERATIVE. REPLACED LAMP ASSY, OPS OKAY.SDR UALA2009072702232Bleed Valve · faultyEXPERIENCED A RIGHT ISOLATION BLEED VALVE STATUS AT ENG START. REPLACED RIGHT ISOLATION BLEED VALVE. OPS CHECK ON MAT GOOD.SDR UALA2009072702231Stringer · corrodedAFT CARGO COMPT BOTTOM STRINGER HAS CORROSION AT STA 1455, STR 49R SIZE: 5 X 2.1 INCHES. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED PART. NO CRACK FOUND. PART REPAIRED PER EN:777EN-53-0050-01.SDR UALA2009072802264Light · inoperativeONE (1) EA EEL STRIP LIGHT ON SIDE OF SEAT 3F INOPERATIVE. REPLACED EEL STRIP LIGHT. OPS CHECKS GOOD.SDR UALA2009072702223Connector · unsecureEMERGENCY EXIT LIGHTS INOP AT SEAT 15F FWD AND AFT LIGHT ASSY'S. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2009072702222Connector · unsecureEMERGENCY EXIT LIGHTS INOP AT SEAT 15D FWD AND AFT LIGHT ASSY'S. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2009072702221Battery Pack · inoperativeEMERGENCY EXIT LIGHTS INOP FROM DOOR 2 RIGHT THRU ROW 11 RIGHT CEILING. REPLACED BATTERY, OPS CHECKS NORMAL.SDR UALA2009072702220Light · inoperativeEMERGENCY EXIT LIGHT INOP AT SEAT 3F FWD LIGHT ASSY. REPLACED LIGHT ASSY, OPS CHECKS NORMAL.SDR UALA2009072702224Ballast · failedODOR EMANATING FROM CEILING AREA ABOVE LAV AT DOOR 2L. SECURING LIGHTS, IFE, RECIRC FANS, NO HELP. ODOR NOT DISSIPATING. FOUND LAV FLO LIGHT ASSY LAMP HOLDER LOOSE AND EVIDENCE OF SMOKE, BURNT PLASTIC, EVIDENT. DUPLICATED DISCREPANCY. LIGHT ASSY AND BALLASDR UALA2009072802263Control Valve · faultyPACK FCV R ONE (BUT NOT BOTH) OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. REPLACED UPPER RIGHT FCV. OP CHECKS NORMAL.SDR UALA2009072802262Generator · failedELEC BACKUP GEN R EICAS MSG DISPLAYED AFTER START. SERVICED AND RAN ENGINE, NO HELP MAT SHOWS. MAINTENANCE MESSAGE 24-46010, SHEARED SHAFT. REPLACED BACKUP GENERATOR. ACCOMPLISHED LEAK CHECK, NO LEAKS.SDR UALA2009072702226Battery Pack · no testMED 1R HAS EPAS BATTERY THAT WON'T TEST. REPLACED EPAS BATTERY PACK. OP'S CHECKED GOOD.SDR UALA2009072702225Light · inoperativeSEATS 1E & 3E IN FIRST CLASS EMERGENCY FLOOR PROX LIGHTS INOP. REPLACED AFT EMERGENCY PROX LIGHT IN BOTH SEATS.SDR UALA2009072702213Starter · faultyAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF ONE ARINC 629 CHANNEL. STATUS MSG01- ACTIVE TAXI IN HARD; ELECTRIC STARTER MOTOR HAS BRUSH WEAR. DB- APU CONTROLLER (APUC) MSG02- ACTIVE TAXI IN HARD; ELECTRIC STARTER MOTOR HAS BRUSSDR UALA2009072702235Microphone · faultyFIRST OFFICER OXYGEN MIC INOPERATIVE. NEED NEW O2 ASSY PN MXP 402-3. NR INOP 02 ASSY WAS MOVED TO SECOND OBSERVERS SEAT, AND MEL USED REFLECTS THIS. 2ND OBSERVERS SEAT IS INOP (FIRST OFFICERS O2 ASSY IS OK)
Back to Boeing 777-222