SDR 2007UALA01288Skin · crackedRT WING L/E AFT OF NR 9 SLAT CRACKED OUT FROM RESTORATION SEAL CUTOUTS. [SUP 05-18-07] RT WING L-E AFT OF NR 9 SLAT CRACKED OUT FROM RESTORATION SEAL CUTOUTS. REPAIRED PER OV WRITE-UP W1682T AND R&R R41952.SDR 2007UALA01284Battery Pack · dischargedC XOME AT PED NR 4 RT AND LT OVERHEAD PANEL EMERG LIGHTS INOP. REPLACED BATTERY PACK ABOVE DOOR 4 RIGHT. OP CHECKED GOOD.SDR 2007UALA01283Battery Pack · dischargedM2 GALLEY UNITS BOTH RT AND LT EEL LIGHT STRIPS INOPERATIVE. REPLACED BATTERY PACK IN DOOR OVERHEAD PANEL AT 2 LEFT. OP CHECKED GOOD.SDR 2007UALA01259Pcu · leakingARRIVAL CHECK FOUND RUDDER UPPER POWER CONTROL PACKAGE HYD HEAVY LEAK. [SUP 05-18-07] REPLACED UPPER RUDDER POWER CONTROL UNIT. REF MM 27-21-11 P401. COMPLETED OPERATIONAL CHK AND LEAK CHECK . BOTH CHECKED OK.SDR 2007UALA01197Bottle · lowCREW OXYGEN PRESSURE LOW 900 PSI. [SUP 05-16-07] REPLACED OXY BOTTLE. LEAK CHKD AND INDICATED OK. SUSPECT LOW PRESSURE THE RESULT OF CREW SNIFF TESTS DURING CHECK LIST.SDR 2007UALA01159Structure · damagedNUMBER 13 SLAT APPEARS DAMAGED. REPLACED NR 13 SLAT REF: MM 27-81-15. OP CHECKS GOOD. NO MESSAGES. A/C RETURNED TO SERVICE. SUSPECT SLAT DAMAGED BY FOD DURING TAKEOFF OR LANDING.SDR 2007UALA01183Light · detachedEMERGENCY EXIT PATH LIGHTING STRIP ON LEFT SIDE OF SEAT 1E FELL OFF AGAIN. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR 2007UALA01119Light · damagedEMERGENCY LIGHT DAMAGED AT SEAT 2E. REPLACED AFT EMERGENCY LIGHT ON SEAT 2E. OPS CHECK GOOD.SDR 2007UALA01118Lamp · inoperativeAFT EMERGENCY LIGHT AT SEAT 8D IS OUT. RELAMPED EMERGENCY LIGHT.SDR 2007UALA01051Light · brokenFOUND EEL LIGHT AT 34C BROKEN. REPLACED EEL LIGHT AT 34C. OP CHECKS GOOD.SDR 2007UALA01045Engine · overservicedNR 1 ENGINE HIGH OIL CONSUMPTION AND REPORTS OF OIL LEAKS UNDER COWLING IN THE VICINITY OF THE HIGH STAGE BLEED VALVE. [SUP 5-1-07] NO LEAKS DISCOVERED OR EXCESSIVE OIL ON COWLING. ENGINE OVERSERVICED AT GATE AFTER COOLDOWN. OIL CONSUMPTION NORMAL; RETURNEDSDR 2007UALA01023Wire Harness · disconnectedEMERGENCY LIGHTS AT SEAT 2E INOPERATIVE. FOUND HARNESS DISCONNECTED. CONNECTED HARNESS, TESTED GOOD.SDR 2007UALA01001Battery Pack · faultyPASSENGER ENTRY DOOR 2R, EPAS BATTERY PACK GREEN TEST LIGHT NOT ON. [SUP 5-1-07] INSTALLED NEW BATTERY . GREEN TEST LIGHT ILLUMINATES. DOOR EPAS & AIRCRAFT READY FOR SERVICE.SDR 2007UALA00983Light · missingSEAT 3F ARMREST EMERGENCY LIGHT MISSING. REPLACED EEL LIGHT ASSY & OPS CHECKED OK.SDR 2007UALA00982Lamp · brokenEMERGENCY PATH MARKING LIGHT ONE BROKEN AT SEAT 2F. REPLACED LIGHT STRIP.SDR 2007UALA01002Engine · vibrationNR 2 ENGINE VIBRATION. [SUP 5-1-07] ACCOMPLISHED TRIM BALANCE RUN PER MM72-31-00. ACCOMPLISHED INSPECTIONS OF ALL CHIP DETECTORS PER 79-22-01, AND ACCOMPLISHED INSP. PER FIM 71-05 TASK 821, ITEM B1,C2,3,4,5,6 ONLY ALL ITEMS CHECK OK. A/C RETURNED TO SERVICSDR 2007UALA00958Ground Stud · corrodedCEILING LIGHTS AT SEAT 3E & SEAT 9D ARE OUT. FOUND EMERGENCY AREA LIGHTS INOP AT SEVERAL SEATS. TROUBLESHOOTING REVEALED THAT GROUND BLOCK CORROSION IS INHIBITING STRUCTURAL GROUND. REPLACED GROUNDING STUD. EEL SYSTEM OP CHECKS OK.SDR 2007UALA00952Light · damagedSEAT 2F EVACUATION LIGHT IS DAMAGED. REPAIRED LIGHT. OP CHECKS OK.SDR 2007UALA00933Connector · meltedOVERHEAD ELECTRONICS UNIT DIRECTLY BELOW CENTER VHF ANTENNA FOUND BURNT AND MELTED. [SUP 4-24-07] REPLACED OVERHEAD ELECTRONICS UNIT CONNECTOR. SUSPECT ELECTRICAL SHORT IN OEU CONNECTOR CAUSED MOMENTARY HIGH CURRENT CONDITION.SDR 2007UALA00895Wire Harness · damagedSEAT 25G EMERGENCY ESCAPE PATH LIGHT INOPERATIVE. EEL FEEDER CABLE HAD FAULTY CONNECTION. REPAIRED HARNESS PER GNMM 2-0-15-1. TESTED OKSDR 2007UALA00909Wire Harness · damagedLEFT FUEL QTY INTERMITTENT. [SUP 4-20-07] AFTER TROUBLESHOOTING DETERMINED THAT LT MAIN FUEL QTY HARNESS NEEDED REPLACING. FINISHED REMOVAL AND INSTALLATION OF LT MAIN FUEL QTY HARNESS PER MM 28-41-05. DUE TO LT WING FUEL QTY HARNESS REPLACEMENT NEED TO OPS SDR 2007UALA00838Light · missingAFT SEAT MOUNTED EMERGENCY LIGHT AT SEAT 2E IS MISSING. REPLACED AFT SEAT 2E EEL LIGHT ASSY. EEL LIGHTING SYSTEM CHECKS OKSDR 2007UALA00823Light · inoperativeAFT EMERGENCY LIGHT INOP AT SEATS 1E & 2E. REPLACED LAMP IN AFT EMERGENCY LIGHTS AT SEATS 1E & 2E. OP CHECKS NORMALLY.SDR 2007UALA00816Light · inoperativeEMERGENCY SEAT LIGHT OUT AT 1E. *S/D* RELAMPED, EEL SYSTEM TESTED GOOD.SDR 2007UALA00830Door · obstructedFLT ATTENDANT REPORTED UNABLE TO ARM DOOR 4L. *S/D* REMOVED FOREIGN OBJECT OPERATES NORMAL. AIRCRAFT RETURNED TO SERVICE. SUSPECT FOREIGN OBJECT WAS PIECE OF CABIN SERVICE MATERIAL.SDR 2007UALA00825Packing · leakingPOSSIBLE CENTER HYDRAULIC LEAK. NO EMERGENCY DECLARED. *S/D* FOUND C2 ELECTRIC PRESSURE OUTPUT PACKING LEAKING. REPLACED PACKING NO LEAKS NOTED. HYDRAULIC QTY LOW C CENTER HYDRAULIC SYSTEM LOW RESERVOIR QUANTITY. SERVICED CENTER HYD SYSTEM TO FULL. MSG SDR 2007UALA00815Light · inoperativeTHE AFT EEL PROX LIGHT AT SEAT 3F IS INOP. REPLACED LAMP ASSEMBLY. OP CHECKS OK FOR SERVICE.SDR 2007UALA00814Wire · damagedBOTH EEL PROX LIGHTS AT 1F ARE INOPERATIVE. REPAIRED WIRE TO EEL LIGHTS. ALSO RELAMPED, OP CHECKS GOOD.SDR 2007UALA00784Skin · damagedRIGHTT HORIZONTAL STABILIZER LOWER SKIN HAS IMPACT DAMAGE. RT HORIZONTAL STABILIZER REPAIR ACCOMPLISHED PER UAL EVA 70128. A/C READY FOR RETURN TO SERVICE. SUSPECT DAMAGED BY GROUND EQUIPMENT OR RUNWAY KICK-UP FOREIGN OBJECT.SDR 2007UALA00773Lamp · inoperativeSEAT 43D EEL LIGHT IS INOPERATIVE. RELAMPED. OPS CHECKS GOOD .SDR 2007UALA00772Light · inoperativeFWD EEL LIGHT AT SEAT 3F IS INOPERATIVE. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR 2007UALA00762Valve · stickingFLIGHT DIVERTED DUE TO RIGHT A/C PACK PROBLEM. TROUBLESHOOTING IDENTIFIED PARTIALLY OPEN PACK FLOW CONTROL VALVE. REPLACED RIGHT HAND FLOW CONTROL VALVE. A/C PACK SYSTEM OP CHECKED OK FOR SERVICE.SDR 2007UALA00732Light · inoperativeEEL LIGHT AT 34C INOP. REPLACED LIGHT ASSY, OPS CHECK GOOD.SDR 2007UALA00689Outflow Valve · stuckFLIGHT DIVERTED DUE TO NO WATER PRESSURE. PRE-SELECT OVERFLOW VALVE FOUND TO STICK IN SEMI-CLOSED POSITION. PRIOR TO REPLACEMENT- CHECKED LINKAGES, INDICATION & VALVE OPERATION. VLV OPERATION NORMAL WITH PRE-SELECT KNOB MOVEMENT AT FWD SERVICE PANEL. PRECASDR 2007UALA00673Light · unsecureWIRE HANGING OUT ON AISLE SIDE OF SEAT 1E POSSIBLY FROM EMERGENCY LIGHTING. RESECURED EMERGENCY LIGHT STRIP TO MOVEABLE ARMREST AND EMERGENCY LIGHTS OPERATION TESTED NORMALLY.SDR 2007UALA00653Lamp · inoperativeEEL LIGHT OUT AT 18 C&G. RELAMPED. TESTED GOOD.SDR 2007UALA00652Light · missingSEAT 3E AISLE SIDE MOVABLE ARM REST AFT EEL LIGHT IS MISSING. *S/D* REPLACED EEL LIGHT. OP CHECKS OK.SDR 2007UALA00651Lamp · inoperativeEXTERIOR EMERGENCY LIGHTS INOPERATIVE AT DOOR 3L. CLEANED SOCKET, RELAMPED AND CHECKED PER MM 33-51-04. CHECKS NORMALLY.SDR 2007UALA00631Skin · damagedLIGHTNING STRIKE DAMAGE TO RIGHT NLG DOOR. REPAIRED LIGHTNING STRIKES REF SRM 52-80-01. REPAIR TAP CKS GOOD. A/C OK FOR SERVICE.SDR 2007UALA00578Unknown · smokeSMOKE COMING FROM FWD OUTFLOW VALVE AFTER ENGINE START.SDR 2007UALA00587Oxygen System · reads lowCREW OXYGEN PRESSURE AT ZERO. FOUND LEAKING OXYGEN PRESSURE TRANSDUCER. REPLACED X-DUCER. SERVICED CREW OXYGEN. CHECKED SYSTEM AND FOUND NO LEAKS. SUSPECT LEAKING AT TRANSDUCER CAUSED BY SEAL LEAKAGE.SDR 2007UALA00585A/C Pack · inoperativeLOST RIGHT PACK AFTER DEPARTURE. REPLACED RIGHT SYSTEM LOWER SHUTOFF-PACK FLOW CONTROL VALVE PER MM 21-51-02, PASSED TEST & CLEARED MESSAGE 21-24304 . SUSPECT VALVE STUCK DUE TO FRICTIONAL-INDUCED WARE.SDR 2007UALA00596Warning System · activatedSTATUS MSG -APU-, BUT APU NEVER SHUT DOWN. REBOOTED ACFT, BUT NO HELP. AFTER TROUBLESHOOTING, DETERMINED THAT APU FIRE-OVERHEAT DETECTOR CARD WAS FAULTY. REPLACED CARD & APU OPERATED OK FOR SERVICE. SUSPECT DISTURBED CIRCUIT PATH ON CARD.SDR 2007UALA00582Charger · faultyBATTERY MAIN CHARGER STATUS MESSAGE. MAIN BATTERY CHARGER FAILURE MESSAGE. ACTIVE ES HARD FAULT. AFTER TROUBLESHOOTING, REPLACED MAIN BATTERY. SYSTEM CHECKS OKSDR 2007UALA00576Connector · burnedCONNECTOR DM29311A BURNED FOR THE NR 2 ACMP (CENTER PUMP) RIGHT WHEEL WELL. PUMP REPLACED. CONNECTOR IS TAPED AND TIED OFF IN THE AREA. REPLACED CONNECTOR AND PINS. SYSTEM OP CHECKS OK FOR SERVICE. SUSPECT PUMP ARMATURE DETERIORATION CAUSED GREATER THAN NOSDR 2007UALA00572Switch · inoperativeABOUT 5 SECONDS AFTER GEAR HANDLE TO DOWN POSITION HEARD LOUD BANG IN VICINITY OF NOSE GEAR. ABOUT 2 SECONDS LATER GOT NORMAL GEAR DOWN INDICATION. *S/D* FOUND STRUT PRESS-EXTENSION LOW. NO FLUID LEAKS. REPLACED NOSE GEAR PRESSURE SWITCH SYSTEM CHECKED NOSDR 2007UALA00560Connector · disconnectedFOUND SEAT 3F AISLE EEL LIGHT INOPERATIVE, CONNECTOR DISCONNECTED. RECONNECTED CONNECTOR UNDER THE SEAT AND OP CHECKED OK.SDR 2007UALA00522Light · brokenFOUND SEAT 3E, AFT EMERGENCY PATH LIGHT BROKEN AND INOP. REPLACED LIGHT, OP CHECKS GOOD.SDR 2007UALA00511Light · missingFOUND 2E AFT SEAT SIDE MOUNT EMERGENCY PATH MARKING LIGHT MISSING. REPLACED LIGHT, OP CHECKS GOOD.SDR 2007UALA00524Lamp · inoperativeFOUND SEAT 2F (AFT) AND SEAT 3F AISLE EMERGENCY EVACUATION LIGHTS ARE NOT WORKING. REPLACED LAMP. OP CHECKED OK.
Back to Boeing 777-222