Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA02178Button · missingDOOR 4 RIGHT IS MISSING EPIS BUTTON. [07-20-07] NEW TYPE OF EPAS BATTERY PACK INSTALLED PER AMM 52-11-20 CONFIG 2 PG401 & TEST OK PER AMM. PUSH BUTTON SECURED. OK FOR SERVICE.SDR 2007UALA02157Light · faultyFWD PIT LIGHTS DIM AND CIRCUIT BREAKER F8 IN PNL P35 KEEPS POPPING WHEN CEILING LIGHT AT STA 980 RT IS PUSHED ON. REPLACED LIGHT ASSEMBLY.SDR 2007UALA02125Charger · faultyAT DEPARTURE MAIN BATTERY CHARGER MESSAGE. [07-17-07] REPLACED MAIN BATTERY CHARGER PER MM 24-31-02 . SUSPECT INTERNAL SHORT IN CHARGER.SDR 2007UALA02145Battery Pack · inoperativeALL EEL LIGHTS IN -D SECTION- INOPERATIVE. *S/D* AFTER TROUBLESHOOTING, DETERMINED THAT BATTERY PACK M33401 HAD FAILED. INSTALLED SERVICABLE PACK. SYS OPS NORMAL. RETURNED AC BACK TO NORMAL, OK FOR SERVICE.SDR 2007UALA02144Lamp · inoperativeTHE 18C & 32G EEL LIGHTS ARE INOP. RELAMPED, OP CHECKS GOOD.SDR 2007UALA02092None · noneFLIGHT DIVERTED DUE TO REPORT OF FUMES IN THE CABIN ISOLATED TO THE NR 2 ENGINE. [07-17-07] CHECKED APU INLET & FOUND INTAKE SCREEN FULL OF CICADAS. SUSPECT ALL SMOKE AND ODOR RELATED LOG ITEMS CAUSED BY CICADAS WHICH WERE BURNED BY LOAD COMPRESSOR OF APUSDR 2007UALA02079Apu · smokeAPU SMOKING FROM TAIL PIPE. [07-17-07] REPLACED APU PER MM 49-11- 01. SUSPECT APU INTERNAL OIL LINE LEAK CAUSED SMOKE.SDR 2007UALA02048Blades · damagedRTFL DUE TO NR 2 ENGINE COMPRESSOR STALL. [08-21-07] SURGED IN CLB. EGT EXCEEDED RL FOR 2:37; PEAK 733¡C. SHUTDOWN. METAL IN TAILPIPE. ENGINE REPLACED AT ORD. SHOP DISASSEMBLY REVEALED EXTREME DAMAGE INSIDE THE HP COMPRESSOR. ALL BLADES SHOWED SEVERESDR 2007UALA02078Lamp · inoperativeDOOR 1R EXTERIOR EMERGENCY EXIT SLIDE LIGHT INOP. *S/D* REPLACED LAMP, OP CHECKED OK.SDR 2007UALA02080Oxygen System · reads lowCREW OXYGEN 1200 PSI. [07-17-07] SERVICED CREW OXYGEN. NO LEAKS DETECTED. OK FOR SERVICE.SDR 2007UALA02077Light · inoperativeTHE 3F EMERGENCY LIGHT INOP. *S/D* REPLACED LIGHT.SDR 2007UALA02023Skin · damagedREWORKED SKIN GOUGE AT STA 397 BETWEEN STR 30L-31L IS CRACKED. MARKED ENDS OF CRACK. [07-13-07] DOUBLER INSTALLED PER SRM 53-00-01 REPAIR 10. A/C OK FOR RETURN TO SERVICE.SDR 2007UALA02006Filter · cloggedLEFT ENG IDG DPI POPPED. [07-13-07] REPLACED INTEGRATED DRIVE GENERATOR. OP CHECKS GOOD FOR SERVICE. SUSPECT INTERNAL DEBRIS CLOGGED FILTER & CAUSED DPI TO POP.SDR 2007UALA01979Light · inoperativeFLOOR EMERGENCY LIGHTS BY 11D INOP. [06-26-07] RESET SYSTEM. OPS CHECK OKSDR 2007UALA01981Module · failedSPOILERS FAILURE OF ONE OR MORE SPOILER PAIRS. [07-13-07] PULLED CIRCUIT BREAKER. RERACKED ACTUATOR CONTROL ELECTRONICS (ACE) - L2 MODULE. RESET CB AND PERFORMED PRIMARY FLIGHT CONTROL MAINT ACCESS TERMINAL (MAT) TEST, PASSED. MSG NOT ACTIVE AND SPOILER ADVSDR 2007UALA01980Wire Harness · malfunctionedEVAC LIGHTS INOP AT 3F & 2F. [06-26-07] REPLACED WIRE HARNESS AT SEAT 2F, OP CHECKS GOOD. RELAMPED AFT LIGHT AT 3F, OP CHECKS GOOD.SDR 2007UALA01963Light · detachedEMERGENCY PATH LIGHT AT 3F AFT SIDE CAME OFF. [06-26-07] REPLACED EMERGENCY EVACUATION LIGHT AT 3F AFT SIDE. EMERGENCY LIGHT SYS TEST OK.SDR 2007UALA01926Transducer · fluctuatesFLIGHT DIVERTED DUE TO CREW OXYGEN INDICATION. [07-13-07] REPLACED OXYGEN PRESSURE TRANSDUCER. NO ADDITIONAL FLUCTUATION NOTED. A/C OK FOR SERVICE.SDR 2007UALA01915Tank · leakingFUEL IMBALANCE. EICAS FUEL HAS HISTORY. [07-13-07] TROUBLESHOOTING FUEL IMBALANCE. FOUND LEAK IN LT MAIN TANK, DEFUELED, SUMPED TANK. FND AFT BOOST PUMP DISCHARGE CHECK VALVE BAD. INSTALLED REPLACEMENT FLAPPER FUEL TANK OVERRIDE VALVE & SYSTEM CHECKED OKSDR 2007UALA01894Lamp · missingFOUND SEAT 1E HAS AFT EMERGENCY LIGHT MISSING. [06-26-07] RELAMPED. TESTED GOOD.SDR 2007UALA01886Blade · wornRTFL DUE TO NR 1 ENGINE SURGE. ENGINE SURGED IN CRZ APPROX 2-1/2 HRS OUT FROM IAD EN ROUTE MUC. DECISION TO RETURN TO IAD. AFTER LDG, IAD MM FOUND METAL IN TAILPIPE. ENG REPLACED AT IAD. [08-14-07] TEARDOWN REVEALED THAT 4 LP TURBINE TRANSITION DUCTS (PSDR 2007UALA01857Unknown · smokeRTFL WITH SMOKE IN THE CABIN. [07-06-07] FOUND MAT MSG 49-11150 "APU CONTROLLER FAILED". CONTINUED TROUBLE SHOOTING & DETERMINED SOURCE OF SMOKE WAS APU. REPLACED GTCP331-500B APU. ACCOMPLISHED APU VERIFICATION FLIGHT. AIRCRAFT OK FOR SERVICE. SUSPECT ISDR 2007UALA01816Sign · unsecureMAIN AISLE EXIT SIGN AT 3L FOUND HANGING BY WIRE HARNESS. [07-06-07] ACCOMPLISHED INTERIM REPAIR OF EXIT SIGN. RECHECK SECURITY OF INTERIM REPAIR AT EACH NR 3 SVC. MF8689 CREATED TO MONITOR FINAL FIX. SUSPECT SIGN IMPACTED BY LONG PASSENGER CARRY-ON OBJECTSDR 2007UALA01791Electrical Sys · no testELEC STANDBY SYS ELECTRICAL DC-STANDBY POWER SYSTEM FAILED THE SYSTEM SELF-CHECK. [07-06-07] REPLACED BUSS TIE, MAIN BATTERY RELAY. AIRPLANE OK FOR SERVICE.SDR 2007UALA01790Idg · faultedELEC GEN DRIVE L LEFT IDG FAULT. [07-06-07] REPLACED IDG PER MM 24-11- 01, SUBSEQUENT VERIFICATION FLIGHT CONFIRMED CORRECTION OF PREVIOUS PROBLEM. AIRPLANE OK FOR ETOPS.SDR 2007UALA01769Cylinder · unreliableFOUND DOOR 4R EPAS DOOR CYLINDER SQUIB TO HAVE NO EXPIRATION DATE. [07-06-07] REPLACED EPAS DOOR ASSIST CYCLINDER SQUIB WITH ONE THAT HAS AN EXPIRATION DATE & AIRPLANE OK FOR SERVICE.SDR 2007UALA01768Battery Pack · unreliableFOUND 4R DOOR BATTERY PACK SERVICEABLE DATE SMUDGED AND HARD TO READ. [07-06-07] REPLACED EPAS BATTERY PACK ASSY PER MMOV 52-11-20 CONFIG 1 AND CONFIG 2. AIRCRAFT READY FOR SERVICE.SDR 2007UALA01722Valve · leakingLOW BOTTLE PRESSURE. THERE WAS A SMALL LEAK IN THE FILLER VALVE. REPLACED WITH NEW FILLER VALVE. REPLACED BOTTLE WITH A STOCK BOTTLE AND REPAIRED THE OLD BOTTLE AND PUT BACK IN STOCK.SDR 2007UALA01719Sensor · failedFUEL IMBALANCE LEFT AND RIGHT MAIN TANK QUANTITIES DIFFER BY A PRE-DETERMINED AMOUNT. ADVISORY CREW COMMENTS: UNEXPLAINED IMBALANCE - LEFT WING TANK LOW. TOTAL FUEL USED NORMAL. REPLACED RIGHT WING NR 10 TANK FUEL QUANTITY UNIT AND WATER-IN-FUEL DETECTOR PSDR 2007UALA01645Switch · faultyCABIN MED 3RT FAILED EPAS BATTERY OPERATIONAL TEST. [06-20-07] REPLACED MODE SELECTOR SWITCH AND OPS CHECK PER MM 52-11-28, AND COA208701. TEST OK. A/C OK FOR SERVICE.SDR 2007UALA01632Engine · stalledCREW REPORTED A SURGE - STALL IN CRUISE (STEADY STATE) NR 2 ENG, "AUDIBLE" TO FLT AND CABIN CREW. [07-17-07] ENGINE REPLACED. TEARDOWN SHOWED HEAVY HPC BLADE AIRFOIL DAMAGE FROM THE 6TH STAGE AFT. 1/8TH STAGE BLADE AIRFOIL WAS BROKEN OFF 1/2-INCH ABOVE TSDR 2007UALA01603Power Supply · inoperativeEMERGENCY EXIT LIGHTS ON SEATS ROWS 11-15 BOTH AISLES ARE INOPERATIVE. [SUP 06-06-07] REPLACED POWER SUPPLY.SDR 2007UALA01602Lamp · inoperativeEXTERIOR EMERGENCY EXIT LIGHTS ADJACENT TO DOORS 3 LEFT AND 2 RIGHT ARE INOPERATIVE. [SUP 06-06-07] RELAMPED.SDR 2007UALA01629Circuit Breaker · faultyEVACUATION TEST BUTTON ACTIVATES THE EVAC WARNING SYSTEM. [06-15-07] PULLED EVAC SIGNAL CB K4 AT THE P 310 PANEL IN THE EE COMPARTMENT PULLED PER CREW REQUEST. RESET CIRCUIT BREAKER AND ACCOMPLISHED SYSTEM TEST PER MMOV 25-63-02, SYSTEM CHECKS NORMALLY.SDR 2007UALA01583Unknown · odorCREW REPORTS ON TAKE OFF TOWER REPORTED SMOKE FROM ENG 1, NO ABNORMAL ENG PARAMETER OR EICAS MSG, IT WAS A FULL POWER TAKE OFF DUE TO EPR MODE BEING INOP. VISUAL INSP OF ENG AREA DURING FLIGHT WAS NORMAL, NO ODOR IN COCKPIT OR CABIN (CONFIRMED BY CREW). [06SDR 2007UALA01585Seal · out of adjustDOOR 2L WON'T ARM. *S/D* ADJUSTED LOWER DOOR SEAL ON DOOR 2L. OP CHECKS NORMALLY.SDR 2007UALA01582Lamp · inoperativeEXTERIOR EMERGENCY LIGHT AT DOOR 2R IS OUT. [SUP 06-06-07] RELAMPED.SDR 2007UALA01519Generator · disconnectedLEFT GENERATOR DISCONNECTED DUE TO LOW OIL PRESSURE. FLIGHT DIVERTED. [06-14-07] REMOVED AND REPLACED LEFT IDG. ACCOMPLISHED SERVICE AND LEAK CHECK. ACCOMPLISHED 5 MIN IDLE RUN AND FOUND NO LEAKS. OK FOR SERVICE. SUSPECT SEAL LEAKAGE PROBLEM.SDR 2007UALA01463Idg · failedCREW REPORTS RIGHT GENERATOR FAILURE. APU BEING USED & APU INLET DOOR OPEN. APU AUTO SHUTDOWN AT 16500 FT 310K & AGAIN AT 14500 FT 250K IDLE POWER. [SUP 06-06-07] NR 2 ENGINE IDG WAS REPLACED, BUT CAUSE OF W-U WAS APU AUTO SHUTDOWN. AFTER TROUBLESHOOTING,SDR 2007UALA01462Module · malfunctionedRIGHT HYDRAULIC SYSTEM INOP. QTY SHOWS ZERO. [SUP 06-06-07] REPLACED HYDRAULIC INTERFACE MODULE (HYDIM) (R) CARD. ACTIVE DC HARD FAULT. AFTER REPLACEMENT, INDICATIONS RETURNED TO NORMAL.SDR 2007UALA01460Lamp · inoperativeSEATS 18C, 19C, 19G, 22G, 32G & 39G EEL LIGHTS ARE INOPERATIVE. RELAMPED EEL LIGHTS. OK FOR SERVICE.SDR 2007UALA01455Skin · damagedLIGHTNING STRIKE DAMAGE ABOVE COCKPIT AT STA 219 LBL 9.5 AND STA 201 LBL 8. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2007UALA01443Skin · damagedUPPER FUSELAGE SKIN AT STA 247 STR 1L LBL 4 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: INSTALLED TRIPLER REPAIR.SDR 2007UALA01442Structure · damagedSTA 360.0 STR 2L IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE STA 360 STR 2L. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.SDR 2007UALA01441Structure · damagedSTA 285.5 STR 2L IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE STA 285.5 STR 2L. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.SDR 2007UALA01440Structure · damagedSTA 256 LBL 10 IS DAMAGED. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED DUE TO LIGHTNING STRIKE DAMAGE ON UPPER FUSE BS 256 LBL 10. REPAIR ACCOMPLISHED AND INSPECTED. A/C OK FOR RETURN TO SERVICE.SDR 2007UALA01437A/C Pack · unknownLEFT AIR COND PACK PROB CAUSED DIVERSION. [SUP 06-01-07] REPLACED RT HAND FLOW CONTROL VALVE PER MM21-51-02. FAULT CLEARED AND OP CHECKED GOOD.SDR 2007UALA01357Fan · odorF/A'S REPORTED SLIGHT SMOKE OR ELECTRICAL ODOR IN CABIN ORIGINATING FROM BUSINESS CLASS. REPLACED RIGHT HAND RECIRCULATION FAN PER MM 21-25-07, ALL OPS GOOD,TEST PASS PER MAT OF RECIRC FAN SYS.SDR 2007UALA01356Light · brokenAFT EMERGENCY LIGHT ON SEAT 2F IS BROKEN. REPLACED LIGHT.SDR 2007UALA01355Light · unsecureEEL STRIP ON SEAT 2E LOOSE. SECURED STRIP ON SEAT. NO DEFECTS NOTED.
Back to Boeing 777-222