Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2006UALA00104Light · damagedEMERGENCY EXIT LIGHTS DAMAGED AT 1E.SDR 2006UALA00105Converter · faultyBOTH BACKUP GENERATORS FAILED. RESET ATTEMPT FAILED. ALSO SMELLED SMOKE ODOR. A BURNED BACKUP CONVERTER CAPACITOR FOUND BY SHOP 147 WAS LATER CONFIRMED BY HAMILTON SUNDSTRAND WHO SERVICES THE UNIT AS THE CAUSE OF FAILURE. THE CAPACITOR WAS REPLACED AND THE USDR 2006UALA00103Fairing · damagedNR 1 ENGINE PYLON AFT FAIRINGS HAVE SUSTAINED HEAT DAMAGE TO LWR WEBS, STIFFENERS, CHORDS AND LWR PORTION OF THE FRAMES. NR 1 ENGINE PYLON AFT FAIRINGS HAVE SUSTAINED HEAT DAMAGE TO LWR WEBS, STIFFNERS, CORDS AND LWR PORTION OF THE FRAMES. INTERIM REPAIR WSDR 2006UALA00092Lamp · inoperativeSEAT 1E AFT EMERGENCY LIGHT INOP.SDR 2006UALA00087Lamp · inoperativeAFT EMERGENCY PROX EEL LIGHT AT SEAT 11D IS INOP.SDR 2006UALA00048Warning Light · illuminatedON TAKEOFF, NOSE GEAR DELAYED RETRACTION. MOMENTARY GEAR DOOR DISAGREE EICAS. NOSE GEAR SLOW TO RETRACT. FERRIED A/C TO SFO FOR RETRACTION TEST. WITH A/C JACKED, PERFORMED GEAR SWING. UNABLE TO DUPLICATE "SLOW TO RETRACT." AFTER A/C REPEATED SLOW TO RETRASDR 2006UALA00044Bulb · burned outEXTERIOR EMERGENCY SLIDE LIGHT INOP AT DOORS 1R AND 2L.SDR 2006UALA00024Lamp · inoperativeEEL LIGHT INOP 19C.SDR 2005UALA01536Lamp · inoperativeEMERGENCY LIGHT AT SEATS 18C, 20G, 14F FWD WILL NOT LIGHT.SDR 2005UALA01505Skin · damagedSKIN DAMAGE BELOW DOOR ONE RIGHT.SDR 2005UALA01504Lamp · brokenARMREST SIDE ONE EMERGENCY PATH MARKING LIGHT BROKEN AT SEAT 1E. REPLACED LAMP ASSY.SDR 2005UALA01483Rod · disconnectedDECISION WAS MADE TO RTF AFTER CREW HEARD LOUD VIBRATION COMING FROM THE FRONT OF THE AIRCRAFT AFTER GEAR WAS RETRACTED. ON ARRIVAL FOUND LEFT AFT NOSE LANDING GEAR DOOR STRUT ROD DISCONNECTED FROM DOOR. NOSE LANDING GEAR LEFT AFT DOOR STRUT ASSY PULLED OUT SDR 2005UALA01476Slide · unserviceableASPIRATORS, TOP & BOTTM LEAKING FROM THE FLAPPER VALVES. SLIDE/RAFT WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. ASPIRATOR FLAPPER VALVES WERE OBSERVED LEAKING DURING SLIDE/RAFT OVERHAUL AIR RETENTION TEST. SPECIFIC CAUSE OF LEAK WAS NOT DETERMISDR 2005UALA01466Light · inoperativeSEAT 2E BOTH EMERGENCY LIGHTS INOP. RELAMPED BOTH EMERGENCY LIGHTS. OP CHECKS GOOD.SDR 2005UALA01444Skin · dentedDENT WAS FOUND AT SKIN OF BULK CARGO DOOR STA 1916. DAMAGE EXCEEDED LIMIT SO MAJOR REPAIR WAS ACCOMPLISHED. DENT WAS FOUND IN SKIN OF BULK CARGO DOOR STA 1916, WIDTH=1.18" DEPTH=.063". ACP PERM REPAIR PER SRM 52-30-01. REPAIR 12, PARA 4(D). DAMAGED DUE TO ISDR 2005UALA01464Wire · burnedNR 2 ENG IDG WIRING BURNED. NR 2 ENG IDG FEEDER CABLE TERMINAL LUGS FOUND CORRODED AT ENG DISCONNECT. REPLACED LUGS. ALSO FOUND GENERATOR FEEDER CABLE BURNED & CHAFED AT TERMINAL STRIP. SPLICED IN 3 FT SECTION OF NR 2 CU WIRE. REPLACED FEEDER CABLE SEALS ANSDR 2005UALA01463Pbe · unknownPBE'S PACKAGE DEFECTS AT 1L, 2R, 2L, 3L, 4L, AND 4R. THESE PBES WERE PULLED PREMATURELY AND DID NOT HAVE THE VACUUM SEALS BROKEN. MAINTENANCE CONTROL REVIEWED REMOVAL CRITERIA WITH AMTS INVOLVED AND EMPHASIZED THE USE OF THE SEAL INTEGRITY INDICATOR BUTTON.SDR 2005UALA01414Fitting · damagedNR 1 ENGINE AFT SAILTAIL COMPT LWR BKHD FITTING FAIL CONDUCTIVE TEST. NR 1 ENGINE AFT SAILTAIL COMPT LWR BKHD FITTING FAILED CONDUCTIVE TEST BECAUSE OF HEAT DAMAGE. MAJOR REPAIR WAS ACCOMPLISHED PER EVA UA-EVA-50816B.SDR 2005UALA01378Wire Harness · inoperativeSEAT 1E BOTH EEL LIGHTS INOP. SEAT 2E BOTH EMERGENCY LIGHTS INOP/DAMAGED BY PAX ACTIVITY. FOUND EEL HARNESS GOING TO BOTH LIGHTS DAMAGED.SDR 2005UALA01379Light · looseEXIT PATH LIGHT AT 2E IS LOOSE. SECURED LOOSE EEL EXIT PATH LIGHTING AT 2E. JARRED LOOSE DURING PASSENGER ENTRY OR EGRESS.SDR 2005UALA01283Odor · detectedEQUIPMENT COOLING FAULT ON STS PAGE AND BURNING SMELL IN CABIN. EQUIPMENT COOLING FAN ASSEMBLY FAILED. FAN ASSEMBLY REPLACED.SDR 2005UALA01281Connector · looseSEAT 2F AFT EMERGENCY LIGHT INOP. CONNECTOR LOOSE.SDR 2005UALA01280Lamp · failedSEAT 1F AFT EMERGENCY LIGHT INOP. REPLACE BULB.SDR 2005UALA01263Warning Light · illuminatedFLIGHT DIVERTED UNDER AMBER ALERT DUE TO MULTIPLE AIR DATA SYSTEM PROBLEMS, OVERWEIGHT LANDING. FOUND DAMAGED QUICK DISCONNECT FOR RIGHT AIR DATA MODULE (ADM) CAUSING INVALID SIGNAL. THE QUICK DISCONNECT WAS REPLACED. THERE WERE 3 ADMS BEING REPLACED AND 2 ASDR 2005UALA01250Lamp · inoperativeEMERGENCY WHITE AISLE LIGHT INOP AT SEAT 35G. SUPPLEMENTAL DATA UPDATE REPLACED LAMP.SDR 2005UALA01249Lamp · inoperativeSEAT 1E AFT EMERGENCY LIGHT ASSEMBLY BROKEN. SUPPLEMENTAL DATA UPDATE RELAMPED AFT EMERGENCY LIGHT AT 1E.SDR 2005UALA01223Skin · delaminatedNR 2 SLAT LWR SURFACE DELAMINATED AT INBOARD END 3 INCHES FROM THE TRAILING EDGE. INTERIM REPAIR PER 777 AMM 57-43-99. ACP AN INITIAL INSP AT 50 CYCLE AND EVERY 500 FLT CYCLE UNTIL PERMANENT REPAIR ACPL AT NEXT HMV (5JUNE06). OK TO CF PER AMM AND SFOIQ WALSDR 2005UALA01222Skin · delaminatedNR 3 SLAT LWR SURFACE DELAMINATED AT OUTBOARD END 4 INCHES FROM TRAILING EDGE. INTERIM REPAIR PER 777 AMM 57-43-99. ACP AN INITIAL INSP AT 50 CYCLE AND EVERY 500 FLT CYCLE UNTIL PERMANENT REPAIR ACPL AT NEXT HMV (5JUNE06). OK TO CF PER AMM AND SFOIQ WALSH.SDR 2005UALA01221Skin · delaminatedNR 5 SLAT LWR SURFACE DELAMINATED AT INBOARD END NEAR TRAILING EDGE. INTERIM REPAIR PER 777 AMM 57-43-99. ACP AN INITIAL INSP AT 50 CYCLE AND EVERY 500 FLT CYCLE UNTIL PERMANENT REPAIR ACPL AT NEXT HMV (5JUNE06). OK TO CF PER AMM AND SFOIQ WALSH.SDR 2005UALA01220Oxygen Mask · leakingCREW OXYGEN WAS LEAKING. REPLACED SECOND OBSERVER'S FULL FACE MASK. THIS MASK WAS ORIGINALLY INSTALLED IN THE CAPT'S POSITION AND THEN SWAPPED. OXYGEN LEAK FOLLOWED AFTER SWAP. NO NEW WRITE UPS FOR OXYGEN AFTER THE MASK WAS REPLACED.SDR 2005UALA01208Light · inoperativeSEAT 1E EMERGENCY PROX LIGHT INOP. REPLACED FOWARD EEL LIGHT AT 1E.SDR 2005UALA01188Light · dislodgedEEL LIGHT AT 1F HAS FALLEN OFF. REPLACED FOWARD EEL LIGHT AT 1F.SDR 2005UALA01179Target · out of alignmentEICAS MSG FOR FORWARD CARGO DOOR OPEN. INSPECTED DOOR WHEN AIRCRAFT ARRIVED AND FOUND TARGETS NOT ALIGNED. DOORS WERE CYCLED: DOOR LATCHES AND TARGETS ARE ALIGNED. MESSAGE IN MAT IS NOT ACTIVE. NO LOSS OF PRESSURE.SDR 2005UALA01169Skin · dentedFOUND DENT 3 FT FWD OF DOOR 4L, AND 1 FT BELOW DOOR THRESHOLD. SKIN DENT REPAIRED PER SRM.SDR 2005UALA01160Wedge · damagedNR 9 LEADING EDGE SLAT HAS INTERIM REPAIR INSTALLED INBOARD T/E WEDGE ON LWR SKIN. LOCALIZED DELAMINATION ON THE LOWER SKIN AT THE ENDS OF THE TRAILING EDGE WEDGE OR JUCT AFT OF THE ACTUATOR ATTACH POINTS IS COMMONPLACE FOR THE 777 SLATS. THE 777 AMM 57-43-99SDR 2005UALA01144Housing · damagedLOSS OF LEFT BLEED AIR. MAINTENANCE FOUND A 5 INCH DIAMETER HOLE IN FAN INLET DIFFUSER HOUSING (FIDH) DUE TO BROKEN FLANGE ATTACHING THE FIDH TO THE HEAT EXCHANGER. REPLACE FAILED FIDHSDR 2005UALA01145Light · inoperativeEEL LIGHT AT 18G AND 39G INOP. REPLACED EEL LIGHT.SDR 2005UALA01136Odor · detectedELECTRICAL BURNING SMELL AND HUMMING NOISE FROM DOOR 2 AFT CHILLER. MANUFACTURER REPORTS COMPRESSOR CRUSH WASHERS RELIEVED, ALLOWING RELEASE OF REFRIGERANT AND OIL. NO CAUSE FOR OVERPRESSURE FOUND. MANUFACTURER REPORTS PERIOD OF QUALITY DEPARTURE DESCRIBED ASDR 2005UALA01124Smoke · detectedELECTRICAL ODOR (HEAT) APPARENT AROUND DOOR 2R. OPENED CLOSET AT 2R AND SMOKE WAS SEEN TO EXIT. GALLEY POWER TURNED OFF AND ODOR DISSIPATED. REPLACED TRANSFORMER 10/11/05. SYSTEM HAS BEEN FUNCTIONING NORMALLY AS OF 11/10/05. PROBLEM APPEARS TO HAVE BEEN A OSDR 2005UALA01096Light · looseAFT EEL LIGHT 1F RIPPED FROM POS. REPLACED EEL LIGHT.SDR 2005UALA01095Light · inoperativeAFT EEL LIGHT 2E INOP. REPLACED EEL LIGHT.SDR 2005UALA00986Odor · detectedCREW REPORTED ELECTRICAL ODOR OR SMELL AROUND DOOR 2R. FOOD/DEBRIS BURNT IN WARMING OVEN. OVENS WERE CLEANED.SDR 2005UALA00975Lamp · inoperativeEMERGENCY LIGHT AT SEAT 2E INOP. RELAMPED.SDR 2005UALA00976Sensor · unknownFLIGHT LOST APU. *S/D* LT IDG WAS INOPED 09SEP05. THE RT IDG WAS INOPED, REPLACED. ON 10SEP05 THE APUC GAVE THE MSG COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH LT AND RT 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TESDR 2005UALA00943Smoke · detectedCREW REPORT OF SMOKE SMELL IN THE AREA OF LAV 3L. ODOR REPORTED INSIDE LAV 3L ONLY; FIRE OFFICIALS INSPECTED AREA ABOVE AND INSIDE LAV WITH HEAT DETECTION EQUIPMENT; NO PROBLEMS FOUND. NO FURTHER OCCURRENCES OF SMOKE OR ODOR NOTED SUBEQUENT TO THIS REPORT. RSDR 2005UALA00917Odor · detectedELECTRICAL ODOR IN CABIN. RAN BOTH ENGINES AND APU WITH PACKS AND ALL RECIRC ON; POWERED GALLEYS, PAX ENTERTAINMENT SYSTEM; CHECKED E/E COMPARTMENT AND CABIN CEILING AREA; NO ODORS DETECTED. ROOT CAUSE UNKNOWN.SDR 2005UALA00918Terminal Block · overheatedNR 1 ENGINE UPPER IDG TERMINAL BLOCK HAS MELTED AREAS AND MISSING SHRINK WRAP ON WIRES. THE IDG STRUT DISCONNECT TERMINAL BLOCK INSPECTION/TORQUE CHECK ACCOMPLISHED AT THE SEGMENTED 'A' DISCOVERED THE OVERHEATED TERMINAL BLOCK. REVIEW OF IDG WRITE-UPS, LOGBOSDR 2005UALA00903Lamp · inoperativeSEAT MOUNTED FLOOR PROXIMITY LIGHT AAT SEAT 1E INOP. REPLACED EEL LAMP ASSY.SDR 2005UALA00904Lamp · inoperativeEEL LIGHT INOP 21G. REPLACED LAMP ASSY.SDR 2005UALA00877Charger · faultyRECEIVED BATTERY CHARGER FAULT. MECHANICS FOUND CIRCUIT BREAKER FOR MAIN BATTERY CHARGER TRIPPED. THE BATTERY AND CHARGER WERE REPLACED PER MM 24-31-01 AND 24-31-02. REMOVED BATTERY PN 263BA101-2 SN 1049A HAS BEEN SENT TO THE VENDOR FOR REPAIR. BATTERY CH
Back to Boeing 777-222