Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2006UALA01384Light · malfunctionedTHE 3LR, 4LR OVERHEAD EMERGENCY LIGHTS BLINK ON AND OFF. UNABLE TO DUPLICATE BLINKING PROBLEM WITH EMEG LTS ARMED. CLEANED SWITCH S1 ON P5 MODULE M30001 AND TESTED SYSTEM. EMERG LTS OPS CHK OK.SDR 2006UALA01383Light · inoperativeTHE 24G EEL LIGHT INOP. INSTALLED SVCBL ASSY, OPS CKD PER SAME. SYS OPERATES NORMALLY, AIRCRAFT RETURNED TO SERVICESDR 2006UALA01378Lamp · inoperativeTHE 24G EEL LIGHT INOPERATIVE. INSTALLED SVCBL ASSY, OPS CKD PER SAME. SYS OPERATES NORMALLY, AIRCRAFT RETURNED TO SVC.SDR 2006UALA01367Lamp · inoperativeEXIT EMERGENCY LIGHT BY DOOR 3R INOP. *S/D* RELAMP LIGHT AND OPS CHECK. OP'S CHECK OK.SDR 2006UALA01377Light · inoperativeBOTH LWR EMERGENCY LIGHTS INOP AT DOOR 1L, BOTH AFT LIGHTS ON SEATS 1F & 2F & SEATS 19C & 25C. REPLACED BATTERY PACK FOR DOOR 1L LIGHTD, REPLACED LIGHT ASSY'S FOR 1F, AND 2F. AND RELAMPED SEATS 19C & 25C. ALL OP CHECKED OKSDR 2006UALA01290Wire · exposedEEL LIGHT WIRING EXPOSED AND DAMAGED AT SEAT 8D. REPLACED WIRE WITH CONNECTOR TO AFT ELL LIGHT. OPS CK GOOD. SUSPECT DAMAGE CAUSED BY PASSENGER CARRY-ON LUGGAGE OR CABIN SERVICE EQUIPMENT IMPACT.SDR 2006UALA01279Adc · inoperativeACTIVE CRUISE HARD;SECONDARY ATTITUDE AIR DATA REFERENCE UNIT HAS NO OUTPUT ON ANY BUS. FIM: 34-21T TASK 874LONMSG-3438801 ACTIVE ER HARD MSG-3438801 ACTIVE ER HARD. REPLACED SECONDARY ATTITUDE AIR DATA REFERENCE UNIT. HAS NO OUTPUT ON ANY BUS. AIRCRAFT SSDR 2006UALA01261Skin · damagedDENTS AT STA 1660 BETWEEN STR 43R & STR 44R AND BETWEEN STR 44R & STR 45R. BOTH DENTS ARE APPROX 7 INCHES IN DIAMETER, SMOOTH BUT WITH A .25 INCH DEPTH. FWD OF AFT PIT BELOW FLOOR LEVEL. DENT AT STA1660 BETWEEN STR 43R & STR 44R, DENT AT STA 1660 BETWEEN STR4SDR 2006UALA01257Vacuum Sys · obstructedLAV PROBLEMS. AFT VACUUM SYS LAVS BLOCKED. FOUND WASTE SYSTEM VACUUM BLOWER INOPERATIVE. ALSO, DAMAGE TO DUCTING AND CLAMP AROUND DUCT. ACCCOMPLISHED DUCT REPAIR & CLAMP REPLACEMENT. REPLACED VACUUM FAN BLOWER. SECURED UNIT IN AFT CARGO COMPARTMENT. REACTISDR 2006UALA01251Engine · malfunctionedFLT ENCOUNTERED HIGH EGT WITH EPR DECREASE FOR 5 SECS ON NR 2 ENGINE AT FL390. EGT READING 466. UNABLE TO CONFIRM "SURGE" OR "BURP" IN ON-BOARD ELECTRONIC RECORD. NO FLAGGED EVENT IN ENGINE CONDITION MONITORING RECORD. PERFORMED PRECAUTIONARY BORESCOPE OF HSDR 2006UALA01235Light · ground damageFOUND SEAT MOUNTED EMERGENCY LIGHT BROKEN OFF AT SEAT 2E. REPLACED LIGHT ASSY. OPE' C'K OK. SUSPECT CONTACT BY PASSENGER CARRY-ON LUGGAGE OR CABIN SERVICE EQUIPMENT.SDR 2006UALA01196Odor · detectedFLIGHT ATTENDANTS REPORTED SEEING HAZE AND SMELLING STRANGE ODOR FROM AFT SECTION OF CABIN. UNABLE TO DUPLICATE HAZE OR ODOR DURING 40 MINUTE TAXI WITH ALL CABIN SYSTEMS ON, COFFEE MAKERS, HOT PLATES, OVENS, WARMERS, CHILLERS, VTR'S, LAV LIGHTS, GALLEY LIGHTSDR 2006UALA01149Skin · lightning strikeLIGHTNING STRIKE WAS FOUND ON OUTER SKIN AROUND FASTENER OF LT FUSELAGE STA 446, ABOUT 1.5" UNDER S-26L. REMOVED DAMAGED SKIN AND ACCOMPLISHED HIGH FREQ EDDY CURRENT INSP ON DAMAGE AREA. MANUFACTURED AND INSTALLED DOUBLER PER SRM 53-00-01, REPAIR 6.SDR 2006UALA01055Skin · dentedDENT UNDER LT WING 6 FEET OUTBD OF NR 1 PYLON AND 5 FT AFT OF FUELING PANEL. IT MEASURES 3-16TH DEEP AND APPROX 2 INCHES DIAMETER. VISUALLY INSPECTED AREA, PREFORMED HFEC AND FOUND NO DEFECTS. MATERIAL LOSS MEASURED AT .040" STRGR 18 BS 630, BEYOND LIMITS OFSDR 2006UALA01053Light · missingAFT EMERGENCY LIGHT AT SEAT 1E IS MISSING. REPLACED LIGHT, OPS CK GOOD.SDR 2006UALA01039Light · missingEMERGENCY PATH MARKING LIGHT MISSING FROM SEAT 3C. REPLACED LIGHT ASSEMBLY, OPS C HECKS GOOD. PROBABLE IMPACT BY CABIN OCCUPANT.SDR 2006UALA01013Frame · out of limitsFOUND HEAT DAMAGE. THE READING OF THE WEB AND THE BULKHEAD FRAME AT SAF STA 3.62 WERE OUT OF LIMITS. DURING THE ACCOMPLISHMENT OF COA 208490, CONDUCTIVITY TEST FOUND HEAT DAMAGE. THE READING OF THE WEB, 313W3811-13, AND BULKHD, 313W3812-4, AT SAF STA 3.62 WESDR 2006UALA01012Structure · misdrilledA FASTENER HOLE WAS FOUND HAVE FREEZE PLUG AND SHORT EDGE MARGIN FOR MLG WHEEL WELL MOD RT AT STR 36R 2ND FASTENER FROM I/B END. ACCOMPLISHMENT OF SB 777 53A0015, A FASTENER HOLE WAS FOUND TO HAVE A FREEZE PLUG INSERTED AS A REPAIR FOR AN OVERSIZED HOLE. AS SDR 2006UALA01022Gauge · leakingLOW BOTTLE PRESSURE GAUGE THREADED INSTALLATION TO INFLATION VALVE WAS LEAKING DUE TO MISSING TEFLON TAPE THREAD SEALANT. THREAD SEALANT WAS APPLIED AND PRESSURE GAUGE REINSTALLED.SDR 2006UALA00997Shim · migratedFOUND STA 1434, RT KEEL BEAM FITTING, SHIM IS MIGRATED. BS 1434, RH KEEL BEAM FITTING, SHIM IS MIGRATED. REMOVED BROKEN SHIM, ACP HEFC INSP OF HOLES AND SPLICE PLATES FOR CRACK, NO CRACK FOUND. MANUFACTURED SOLID SHIM AND REINSTALL. SHIM MIGRATION TYPICALLY SDR 2006UALA00811Terminal · overheatedINSULATION FOR (6) TERMINALS ON THE BACK ON CB 51 CHILLER AT AFT GALLEY ARE HEAT DAMAGED AND BLACK IN COLOR. PULLED PANEL ASSY FOR ACCESS. CUT OFF OVERHEATED TERMINALS TO PROVIDE SPECIMENS FOR BOEING INVESTIGATION. REPLACED CB (C51) WITH TERMINALS. RETERMISDR 2006UALA00749Skin · dentedFIVE DENTS ON LWR FUSELAGE BETWEEN STATIONS 498 & 504 & STRINGERS 44R & 49L. DENTS WERE REPAIRED PER SRM53-00-01, REPAIR 13.THE REPAIR TERMINATES THE REPETITIVE INSPECTION REQUIRED BY EVA 50760.DENTS CAUSED BY CONTACT WITH GROUND EQUIPMENT.SDR 2006UALA00783Slide · leakingTHE SEAM IS LEAKING BETWEEN THE UPPER AND LOWER TUBE ON THE LEFT SIDE OF THE SLIDE RAFT. OEM REPORTS THAT LEAKAGE WAS THE RESULT OF LOCALIZED PINHOLE LEAKS AND NOT A LEAKING SEAM. DAMAGE IS CONSISTENT WITH LOCALIZED IMPACT OR ROUGH CONTACT DAMAGE TO MATERIAL SDR 2006UALA00775Lamp · inoperativeEEL INOP AT SEAT 11F, 14F, 1F, 8D. RELAMPED FWD POS EEL LIGHTS AT 8D AND 14F. RELAMPED EEL LIGHTS AT 1F & 11F. ALL POSITIONS OP CHECKS NORMALLY.SDR 2006UALA00763Frame · damagedFOUND STA 298.5 LT FRAME OUTER CHORD AT STR 28-30 IS DAMAGED. TEMPORARY REPAIR AND REPETITIVE INSPECTION WAS PERFORMED PER EVA G95-7785A. PERMANENT REPAIR OF THE DAMAGE WAS ACCOMPLISHED PER EVA G95-7785B .SDR 2006UALA00633Light · inoperativeEMERGENCY LT INOP AT SEAT 25C. RELAMPED, TESTED GOOD.SDR 2006UALA00635Switch · malfunctionedSMOKE FROM SEATS 12A/B. AREA VERY HOT TO THE TOUCH. PANEL MATERIAL BEGAN TO MELT. POWER REMOVED FROM SEAT ENTERTAINMENT SYSTEM. FLT ATTENDANT TURNED OFF SEAT POWER AT CACP. FLT CREW CONFIRMED POWER REMOVED FROM SEAT ENTERTAINMENT SYSTEM. REPLACED BOTH SESDR 2006UALA00632Lamp · inoperativeFOUND EMERGENCY LIGHT AT SEAT 34C AND AFT LIGHT ON SEAT 3E ARE INOP. RELAMPED. TESTED GOOD.SDR 2006UALA00631Starter · malfunctionedLEFT IDG FAILED EN ROUTE, APU NO START. APU ELECT STARTER FAILS CHRONIC APU ELECTRIC STARTER PROBLEMS - 7 STARTERS SINCE APU INSTALLATION JAN 05, + 3 START CONTACTORS 2 APU BATTS, 2 CHARGERS SEVERAL APUC'S, AUTO START CONT RELAYS AND VARIOUS OTHER APU COMPONESDR 2006UALA00618Lamp · missingEEL LIGHT AT 39G MISSING. SUPPLEMENTAL DATA UPDATE NSTLD SVCBL ASSY PER MM 33-51-05, OPS CKD PER SAME. SYS OP CHECKED NORMALLY.SDR 2006UALA00597Lamp · missingFOUND AISLE SEAT 3E MISSING EEL LIGHT AT AFT END.SDR 2006UALA00588Lamp · missingFOUND SEAT 3E AFT AISLE EEL LT IS MISSING.SDR 2006UALA00579Light · inoperativeEMERGENCY LIGHT INOP OR MISSING AT SEATS 8F FWD, 3F AFT.SDR 2006UALA00555Hinge Fitting · lightning strikeLIGHTNING STRIKE WAS FOUND ON TOP RUDDER HINGE FITTING IN VERTICAL STAB. THE FITTING WAS DAMAGED BY LIGHTNING STRIKE AND IT WAS REPLACED.SDR 2006UALA00495Wire Harness · shortedSEAT 2F HAS BOTH EEL LIGHTS INOP.SDR 2006UALA00479Control Panel · damagedAFT GALLEY LOST POWER TO RIGHT SIDE. AFT GALLEY LOST POWER TO RIGHT SIDE. COULD NOT RESTORE POWER WITH CB RECYCLE. FOUND BURNED WIRING WITHIN THE AFT GALLEY POWER PANEL AND CIRCUIT BREAKER POPPED. SUSPECT CIRCUIT OVERLOAD FROM INCREASED RESISTANCE WITHIN GALSDR 2006UALA00400Light · brokenAFT EEL LIGHT STRIP AT SEAT 1E BROKEN.SDR 2006UALA00336Bleed Valve · malfunctionedON CLIMBOUT RECEIVED -BLEED OFF ENG L- EICAS MESSAGE. AT CRUISE, RESET LEFT ISO VALVE AND LEFT ENG BLEED VALVE. BLEED RESTORED 6 MINUTES THEN -BLEED OFF ENG L- MESSAGE AGAIN WITHOUT ISO VALVE CLOSING. TEMPERATURE SENSOR WAS REPLACED AT ORD. TESTING OF REMOSDR 2006UALA00580Wedge · delaminatedTHE NR 2, 3 AND 13 LEADING EDGE SLATS HAVE LOCALIZED DELAMINATION ON THE LOWER SKIN OF THE TRAILING EDGE WEDGE. DELAMINATION REPAIRED TEMPORARILY WITH STRUCTURAL ADHESIVE INJECTION UNTIL PERMANENT REPAIR CAN BE ACCOMPLISHED AT THE NEXT HMV. AN NDT INSPECTIONSDR 2006UALA00308Lamp · inoperativeEMERGENCY LIGHTS INOP AT SEATS 1F FWD LT, 3F REAR LT, 9F FWD LT & 22C.SDR 2006UALA00307Battery Pack · failedALL EEL LIGHTS INOP FROM SEAT ROW 17 THROUGH 27.SDR 2006UALA00287Fitting · brokenDOOR 4 RIGHT AFT GIRT BAR SUPPORT FITTING ASSY BROKEN. DOOR 4 RH AFT GIRT BAR SUPPORT FITTING ASSY WAS FOUND BROKEN. BROKEN FITTING ASSY WAS REPLACED WITH NEW FITTING. DAMAGE CAUSED BY SERVICE TRUCK IMPACT WITH SLIDE PACK & GIRT BAR.SDR 2006UALA00280Precooler · damagedRIGHT ENGINE PNEUMATIC STRUT PRECOOLER HAS A 5 INCH BY 1-4 INCH GAP AT BOTTOM LEFT SIDE. REPLACED RIGHT ENGINE PRECOOLER. OP CHECKS OK. THE DAMAGE FOUND WAS TYPICAL FOR THIS UNIT. THE CYCLING OF THE HPSOV AND THE ASSOCIATED PRESSURE SPIKES CAUSE FATIGUE CRSDR 2006UALA00275Wire · brokenWIRES STICK OUT OF 2E: EMERGENCY LIGHT ON SIDE OF SEAT 1E IS BROKEN.SDR 2006UALA00480Slide · misinstalledNR 1 LT DOOR SLIDE IMPROPERLY PACKED. SLIDE HAD BEEN REMOVED FROM A/C AT C-CHECK FOR ROUTINE DOOR INSPECTION REQUIREMENTS. UPON REINSTALLATION SLIDE WAS REPORTED TO HAVE IMPROPERLY PACKED ASPIRATORS AND WAS REPLACED. MAINTENANCE SHOP CONFIRMS REMOVAL REASON. ISDR 2006UALA00259Lamp · burned outEEL LIGHT INOP AT AFT 3E AND 22G.SDR 2006UALA00225Wire Harness · damagedBOTH EEL LIGHTS INOP AT 3E.SDR 2006UALA00224Lamp · burned outAFT EEL LIGHT INOP AT 1E.SDR 2006UALA00212Lamp · burned outEMERGENCY LIGHTS INOP AT SEATS 21C & 3E FWD LEFT.SDR 2006UALA00177Wire Harness · damagedEEL LIGHTS, SEAT 1F INOP AT BOTH EEL PROX LIGHTS POSITION.
Back to Boeing 777-222