Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2023051101457Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FND BATTERY PACK LOW CAPACITY ON M33409 REF HAECO NON-ROUTINE NO.9456145 - ORIGINATED BY EMP V905467, SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356,REPALCED THE BATTERY PACK ON M33409 AND TEST OK AS PER SDR CALA2023051201483Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FND BATTERY PACK LOW CAPACITY ON M33408 REF HAECO NON-ROUTINE NO.9456145 - ORIGINATED BY EMP V905467, SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356,REPLACED THE BATTERY PACK ON M33408 AND TEST OK AS PER SDR CALA2023051201475Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FND BATTERY PACK LOW CAPACITY ON M33407 REF HAECO NON-ROUTINE NO.9456145 -. SPEC NO.B777-33-3-7019. REPLACED THE BATTERY PACK ON M33407 AND TEST OK AS PER AMM 33-51-06-960-802 REV.97.SDR CALA2023051201474Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FND BATTERY PACK LOW CAPACITY ON M33098 REF HAECO NON-ROUTINE NO.9456145 -. ,SPEC NO.B777-33-3-7019. REPLACED THE BATTERY PACK ON M33098 AND TEST OK AS PER AMM 33-51-06-960-802 REV.97.SDR CALA2023051001451Skin · chafedFUS SKIN (STA 2108 - STA 2150, S2L - S3L) FOUND CHAFING, REFER TO HAECO NR NO. 9410956, SPEC NO. B777-55-3-7032. FUSELAGE SKIN REPAIRED AS PER SRM 53-70-01 REPAIR 2 REV 91 AND ECRA 5370-01079 REV -.SDR CALA2023050901448Battery Pack · inoperative{B777-33-3-7031} EMERGENCY EXIT SIGN AT DR 2R AFT FOUND DIM POWER SUPPLY (M33098) LOCATED AT DR 2R HEADER PANEL. TRANSFER REF. NON-ROUTINE HX NRC WO.1781313 AND ORIGINATED BY EMP V920586 EMERGENCY LT BATTERY PACK (M33098) REPLACED AND INSTALLATION TEST RESULSDR CALA2023050901447Battery Pack · inoperativeEMERGENCY EXIT SIGN AT DR2L AFT FOUND DIM POWER SUPPLY (M33099) LOCATED AT DR 2L HEADER PANEL. TRANSFER REF. NON-ROUTINE HX NRC WO.1781314 AND ORIGINATED BY EMP V920586 EMERGENCY LT BATTERY PACK AT M33099 REPLACED AND INSTALLATION TEST RESULT NORMAL AS PER AMMSDR CALA2023050901446Battery Pack · inoperative{B777-33-3-7031} EMERGENCY FLOOR PROXIMITY LIGHT AT ZONE C FOUND DIM. TRANSFER REF. NON-ROUTINE HX NRC WO.1781315 AND ORIGINATED BY EMP V920586. EMERGENCY LT BATTERY PACK AT (M33409) REPLACED AND INSTALLATION TEST RESULT NORMAL I.A.W. AMM 33-51-06. WORK ACCOSDR CALA2023050901445Skin · damagedFUS SKIN (STA 2108 - STA 2150, S2L - S3L) FOUND CHAFING, REFER TO HAECO NR NO. 9410956, SPEC NO. B777-55-3-7032. PERFORMED BY EMP V905787 RII BY TA589, FUSELAGE SKIN REPAIRED AS PER SRM 53-70-01 REPAIR 2 REV 91 AND ECRA 5370-01079 REV -. RII BY TA589.SDR CALA2023050901423Skin · unknownPREVIOUS REPAIR DOUBLER FOUND ON FUSLAGE SKIN AT STA 1916 STR S-42L. WORK TRANSFER NON ROUTINE WO.1767552 AND ORIGINATED BY V897425. FUSELAGE SKIN AT STA 1916 STR S-42L REPAIRED PER SRM 53-00-01-2R-3 REPAIR 3 RII APPROVED BY HX126723 FUSELAGE SKIN AT STA 191SDR CALA2023041701136Battery Pack · unknownEMERGENCYLIGHT BATTERY PACK M33409 AT DOOR R4 INOP. EPLACED BATTERY PACK M33409 AT R4 DOOR PER AMM 33-51-06-960-802. OPS CCHECKS GOODSDR CALA2023041701135Battery Pack · unknownENTRY FOR SDR REPORTING. REF ST ENGINEERING N/ R 98886, EMERGENCY LIGHTS INOP AT DOORS L1, L2, L3 &. R3. EPLACED BATTERY PACK M33405 AT R3 DOOR PER AMM 33-51-06-960-802.SDR CALA2023041701140Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33098 REF HAECO NON-ROUTINE NO.9452854 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33098 AND TEST OK AS PESDR CALA2023041701139Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33408 REF HAECO NON-ROUTINE NO.9452854 -ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33408 AND TEST OK AS PERSDR CALA2023041701138Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACI TY ON M33405 REF HAECO NON-ROUTINE NO.9452854 -ORIGINATED BY EMP V905467 SEPC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33405 AND TEST OK AS PERSDR CALA2023041701137Battery Pack · dischargedDURING BATTERY PACK CAPACITY CHECK FOUND BATTERY PACK LOW CAPACITY ON M33097 REF HAECO NON-ROUTINE NO.9452854 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7019. PERFORMED BY EMP V905467,IDT BY EMP V924356.REPLACED THE BATTERY PACK ON M33097 AND TEST OK AS PERSDR CALA2023041701128Battery Pack · inoperativeREF ST ENGINEERING N/R 98887. EMERGENCY LIGHTS IN FIRST CLASS CEILING INOP. REMOVED & REPLACED POWER SUPPLY BATTERY PACK M33924 AT L1 DOOR. OPS CHECKS GOOD AS PER AMM 33-51-06-960-802. LOG ENTRY FOR SDR REPORTING. WORK PERFORMED BY V943097SDR CALA2023041201105Thrust Reverser · unknownPDA 3 #1 ENGINE THRUST REVERSER O/B AFT UPPER SIDE HAS 9 FASTENERS MISSING. SEE PHOTO. ADDED PHOTO. INSTALLED NEW FASTENERS REF. SRM 51-40-02, NO DAMAGE TO PANEL NOTED, OK FOR SERVICE.SDR CALA2023041001085Lamp · inoperativeDURING EMERGENCY LIGHT OPERATIONAL CHECK FOUND R/H DOOR NO.2 SLIDE OVERWING LIGHT INOP REF HAECO NON-ROUTINE NO.9452361 - ORIGINATED BY EMP V905467 SPEC NO.B777-33-3-7031. PERFORMED BY EMP V903219,IDT BY EMP V905467. REPLACED THE R/H DOOR 2 SLIDE/OVERWING LIGHSDR CALA2023041001083Servo · unknownHIGH ENG OIL TEMP R-ENG TEMP 166...HIGHEST 177. FUMES IN CABIN. NOT CKPT. NO.2 OIL TANK #2 ENG IDG GEAR BOX (GARLOC) SEAL REPLACED AND SERVICED IDG TO FULL. {PARTS USED: 76-7261-3-0028 }. REMOVED FUEL OIL COOLER AND BYPASS VALVE ON #2 ENG {PARTS USED: 27-SDR CALA2023040401019Battery · failedB777-33-3-7019 LLAR EMER LIGHT BATTERY CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582466 AND ORIGINATED BY EMP V898181. LLAR EMER LIGHT BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSPECTED BY SDR CALA2023040301009Sensor · unknownAPU SHUTDOWN EICAS ADVISORY APU AUTO-SHUTDOWN HAS OCCURRED. APU SURGE BLEED SYSTEM SENSORS FOUND COMPLETELY CLOGGED. THE CIFFERELLO ADDITIONAL MESH FILTER SCREEN LOCATED AT THE INLET PRESSURE CLEARED BLOCKAGES FROM PNEUMATIC LINES AND CLEANED THE INTAKE 40-11-SDR CALA2023040301007Battery · dischargedEMER LT BATT PACK M33405 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564425 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33405 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301006Battery · dischargedEMER LT BATT PACK M33096 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564428 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33096 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301005Battery · dischargedEMER LT BATT PACK M33424 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564433 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33424 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301004Battery · dischargedEMER LT BATT PACK M33409 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564384 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33409 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301003Battery · dischargedEMER LT BATT PACK M33407 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564395 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33407 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301002Battery Pack · dischargedEMER LT BATT PACK M33401 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564405 AND ORIGINATOR BY V924748 REPLACED EMER LT BATT PACK M33401 AND TESTED NORMAL PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301001Battery · dischargedEMER LT BATT PACK M33093 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564434 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33093 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040301000Battery · failedEMER LT BATT PACK M33400 CAPACITY CHECK FAILED. WORK TRANSFER NON ROUTINE WO.1672144 AND ORIGINATOR BY V927704. REPLACED EMER LT BATT PACK M33400 AND TESTED NORMAL AS PER AMM 33-51-06SDR CALA2023040300999Battery · dischargedEMER LT BATT PACK M33408 CAPACITY CHK FAILED. WORK TRANSFER NON ROUTINE WO.1564390 AND ORIGINATOR BY V924748. REPLACED EMER LT BATT PACK M33408 AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECH V927704 AND INSPECTED BY V896992.SDR CALA2023040300997Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33404 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582473 AND ORIGINATED BY EMP V898181. DR R3 EMER LIGHT BATTERY M33404 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300996Charger · failedB777-33-3-7019 DR R2 EMER LIGHT BATTERY CHARGER M33097 TEST FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1591852 AND ORIGINATED BY EMP V898181. DR R2 EMER LIGHT BATTERY CHARGER M33097 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. ATTACH FORM 44-0008 ITEM 1 TO SDR CALA2023040300995Charger · failedB777-33-3-7019 DR R1 EMER LIGHT BATTERY CHARGER M33094 TEST FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1668731 AND ORIGINATED BY EMP V898181. DR R1 EMER LIGHT BATTERY CHARGER M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC SDR CALA2023040300994Battery · failedB777-33-3-7019 DR R1 EMER LIGHT BATTERY M33094 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582468 AND ORIGINATED BY EMP V898181. DR R1 EMER LIGHT BATTERY M33094 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.WORK ACCOMPLISHED BY MECHANIC V89818SDR CALA2023040300993Battery · failedB777-33-3-7019 DR R3 EMER LIGHT BATTERY M33401 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582469 AND ORIGINATED BY EMP V898181. DR R3 EMER LIGHT BATTERY M33401 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300992Battery · failedB777-33-3-7019 DR L3 EMER LIGHT BATTERY M33400 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582476 AND ORIGINATED BY EMP V898181. DR L3 EMER LIGHT BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023040300991Battery · failedB777-33-3-7019 DR L1 EMER LIGHT BATTERY M33424 CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.1582477 AND ORIGINATED BY EMP V898181. DR L1 EMER LIGHT BATTERY M33424 REPLACED AND TESTED NORMAL AS PER AMM33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181SDR CALA2023032900908Unknown · corrodedB777-53-3-7062 , CABIN L2 DR SILL SURFACE CORRODED TRANSFER REF. NON-ROUTINE HX NRC WO.1583570 AND ORIGINATED BY ENP V923416 CABIN L2 DOOR CUTOUT LOWER SILL WEB REPLACED AND INSTALLED AS PER EC/RA 5330-07068 REV-,FORM 44-0008 ITEM 1-12 ACCOMPLISHED . WORK ACCOSDR CALA2023032900907Unknown · corrodedB777-06-3-7171 BULK CARGO COMPT LH SLOPE AT STA2017 S-43L TO S-44L 1EA SHEAR TIE FOUND HEAVY CORROSION TRANSFER REF. NON-ROUTINE HX NRC WO.1596243 AND ORIGINATED BY EMP V917657 BULK CARGO COMPT LH SLOPE AT STA 2017 BETWEEN STR-43L AND STR-44 L SHEAR TIE REPLACSDR CALA2023032700890Idg · unknownELEC GEN DRIVE L EICAS ADVISORY LEFT IDG FAULT (LOW INTERNAL OIL PRESSURE). REPLACED BOTH L&R GCU PER AMM 24-22-02-000-801. GCU POST INSTLATION TESTED. FOUND OK. RAN BOTH ENG. GEN OPS NORMAL. PARTS USED: 1211678,QTY :1 27-2421-9-0001,QTY :1 ROTABLE PARTS CHANGSDR CALA2023032700874Idg · unknownREPLACE LEFT IDG IAW AMM 24-11-01-000-801-001 DUE TO OVERSERVICING AND GEN DROPPING OFFLINE IN FLIGHR LOCKED UNLOCKED REPLACED LH IDG PER AMM 24-11-01-000-801-001. RAN ENG PER AMM 24-11-00-700-801. OPS CHKD OK. PARTS USED: 25-2411-9-0002,QTY :1 ROTABLE PARTS CSDR CALA2023031500763Battery · failedB777-33-3-7019 DR L1 EMER LT BATTERY M33093 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.1483007 AND ORIG BY V898181 DR L1 M33093 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX0855SDR CALA2023031500762Battery · failedB777-33-3-7019 DR R2 M33098 EMER LT BATTERY DEEP CYCLE FAIL. TRANSFER REF NON - ROUTINE WO.1549655 AND ORIG BY V898181 DR R2 M33098 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HXSDR CALA2023031500761Battery · failedB777-33-3-7019 DR R4 EMER LT BATTERY M33408 TEST FAILED TRANSFER REF NON - ROUTINE WO.1563384 AND ORIG BY V898181 DR R4 EMER LT BATTERY M33408 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX08554SDR CALA2023031500760Battery · failedB777-33-3-7019 DR R2 M33097 EMER LT BATTERY DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549666 AND ORIG BY V898181 DR R2 M33097 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031500759Battery · failedB777-33-3-7019 DR L2 EMER LT BATTERY M33099 DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549668 AND ORIG BY V898181 DR L2 EMER LT BATTERY M33099 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031500758Battery · failedB777-33-3-7019 DR L2 M33096 EMER LT BATTERY DEEP CYCLE FAIL TRANSFER REF NON - ROUTINE WO.1549678 AND ORIG BY V898181 DR L2 M33096 EMER LT BATTERY REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V934240 AND INSP BY V896992 IDT APPROVED BY HX0SDR CALA2023031700769Engine · abnormalASYMMETRIC THRUST ON T/O RIGHT ENGINE MAX LEFT ENG LAGGED. ACCOMPLISHED "LEFT & RIGHT TMC - AUTOTHROTTLE SERVO LOOP - SYS TEST" PER AMM TASK 22-31-00-730-802-- PASS. ALSO ACCOMPLISHED "TO/GA SW TEST" PER AMM 22-11-00/501 -- OK. PRESENT LEG & FAULT HISTORY ON MSDR CALA2023031500756Battery · failedB777-33-3-7019 DR L3 EMER LT BATTERY M33400 CAPACITY LOW TRANSFER REF NON - ROUTINE WO.1482995 AND ORIG BY V898181 DR L3 EMER LT BATTERY M33400 REPLACED AND TESTED NORMAL AS PER AMM33-51-06 WORK ACCOMP BY MECH V898181 AND INSP BY V896992 IDT APPROVED BY HX0855
Back to Boeing 777-222