Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013092691480Strip · crackedNR 2 GAP STRIP ON LT ENGINE PYLON CRACKED.SDR CALA2013092691478Seat · faultyFIRST OFFICER`S SEAT ELECTRIC MOTOR MAKES STRANGE NOISE DURING MOVEMENT. REPLACED FIRST OFFICER`S SEAT ASSEMBLY IAW AMM & OPERATIONS CHECKED OKAY.SDR CALA2013092691466Unknown · malfunctionedTROUBLESHOOTING SMC22, REPLACED BOTH OPIC AI & A2 CARDS BUT NO HELP. REINSTALLED BOTH INITIAL CARDS, REPLACED THE OPBC CONTROLLER, ALSO NO HELP. DASH NUMBERS NEED TO BE DOCUMENTED IN MRDATA AFTER REPAIR. MR23931 OFF-110 ON-63. PERFORMED MAT TEST AFTER OPBCSDR CALA2013092691465Bolt · looseFIRST OFFICER`S SEAT WILL NOT MOVE. SEAT FOUND JAMMED AT THE FULL AFT POSITION & UNABLE TO MOVE EITHER ELECTRICALLY OR MECHANICALLY DUE TO ELECTRICAL ACTUATOR MOVEMENT CAUSED BY LOOSE ATTACHMENT BOLTS. RETIGHTENED BOLTS, SEAT NOW OPERATES OK IN BOTH ELECTRICSDR CALA2013092591455Sliding Window · faultyWINDOW HEAT RT SIDE STATUS MESSAGE. RESET CIRCUIT BREAKER ON P110 & PERFORMED A MAT TEST. TEST PASSED HOWEVER, STATUS MESSAGE REMAINED DISPLAYED. SWAPPED WINDOW HEAT CONTROLLERS, NO HELP, SWAPPED BACK. RANG OUT WINDOW 2R HEATING ELEMENT, IAW WD 30-41-11 CONSDR CALA2013092591454Cover · damagedLEFT ENGINE NR 2 HEAT SHIELD GAP COVER STRIP TE CRACKED & SOME MISSING. BLENDED DAMAGE ON NR 2 GAP STRIP OF LT PYLON. TOTAL AREA OF EXPOSURE 12" BY .062" = .744 SQ IN OF TOTAL EXPOSURE. REPAIR AREA WILL REQUIRE HFEC. ACCOMPLISHED HFEC INSPECTION IAW PART 6SDR CALA2013092591450Seal · damagedSEAT 1C LIFE VEST COMPARTMENT SEAL IS DAMAGED. REPLACED SEAL.SDR CALA2013092591449Seal · damagedSEAT 2A LIFE VEST COMPARTMENT SEAL DAMAGED. REPLACED SEAL.SDR CALA2013092591448Shutoff Valve · faultyNR 2 ENGINE WHEN SUPPLY PRESSURE TO 19PSI, REFERENCE PRESSURE IS LESS THAN 15PSI OF HPSOV. INSTALLED WITH NEW HPSOV IAW AMM. TESTED THE HPSOV OK,SDR CALA2013092591445Coupler · faultyLT HF TRANSMIT ISSUES, DUE TO SEVERAL SQUAWKS OF LT HF NOT TRANSMITTING IN FLT BUT CHECKS GOOD ON GROUND. REPLACED LT HF ANTENNA COUPLER IAW AMM 23-11-03. OPERATIONS CHECKED GOOD.SDR CALA2013092491420Connector · damagedFOUND CONNECTOR D5251P ON OEU AT ROW 23 CENTER, CAUSING CIRCUIT BREAKER C23420 "OEU ZN 2 XFR BUSS" TO TRIP. REPLACED DAMAGED CONNECTOR IAW SWPM 20-72-22, WDM23-33-43 & 23-33-46, PSS. OP CHECKED NORMAL.SDR CALA2013092591452Switch · faultyAFT CARGO HEAT VALVE. DUE TO SEVERAL REPEATS FOR AFT CARGO HEAT TEMPERATURE CONTROL. THIS HAS NOW BECOME A LEVEL 2 CHRONIC. REPLACED AFT CARGO OVER HEAT SWITCH IAW AMM21-44-10 MAT TESTED PASSED.SDR CALA2013092591424Shutoff Valve · failedBLEED PRESSURE SENSOR LEFT INTERMEDIATE PRESSURE SENSOR FAULTS EXIST. REPLACED SHUTOFF VALVE.SDR CALA2013092591451Igniter · failedNR 2 ENGINE IGNITER FAILED. REPLACED RT ENGINE NR 2 IGNITER BOSS & PLUG IAW MM 74-21-02. OPS TESTED GOOD.SDR CALA2013092491391Circuit Card · failedHYDRAULIC PUMP EICAS MESSAGE DISPLAYED. REPLACED HYD IM CARD IAW AMM, MESSAGE CLEARED.SDR CALA2013092491416Seal · looseRT GEAR STRUT DOOR, FWD EDGE SEAL DAMAGED TWO PLACES. REPLACED DAMAGED BULB SEAL ON RT GEAR STRUT IAW GMM 5-30-06.SDR CALA2013092691484Unknown · malfunctionedHF RADIO - TRANSMISSION PROBLEM.SDR CALA2013092691481Shutoff Valve · faultyBLEED OFF ENGINE LT ENGINE BLEED VALVE CLOSED FOR SYSTEM FAULT OR SWITCH OFF & THE ENGINE IS NOT SHUTDOWN. PRSOV LOCKED OUT. NR 1 BLEED SYSTEM INOPERATIVE. MEL COMPLIED WITH, REPLACED VALVE.SDR CALA2013092591453Cover · damagedNR 1 ENGINE, NR 1 GAP COVER STRIP DAMAGED IN PREVIOUS REPAIR. HEAT SHIELD NR 2 OTBD SIDE .4" SECTION PROTRUDING PAST GAP COVER. NR 1 CONT OF AMIS ITEM 6602008. DRESSED UP PREVIOUS BLEND REPAIR OF NR 1 ENGINE GAP COVER IAW SRM 54-50-70. REMEASURED AT 3.625XSDR CALA2013092591446Warning System · activatedMAINT MSG 75-50721 'TURBINE CASE CLG AIR VLV ACTR (L ENG CH B) LPT POSITION FEEDBACK IS OUT OF RANGE' HITS OFTEN.SDR CALA2013092391355Skin Panel · delaminatedLT WING LE PANEL 511KB OUTER SKIN LIFTING AWAY FROM CORE OF PANEL 6 INCHES LONG 1 INCH IN WIDTH. R & R THE DELAMINATED PANEL 511KB ON LT WING LE IAW AMM.SDR CALA2013092391345Sdu · failedEICAS SATCOM & DATALINK LOST ANNUNCIATED 600NM FROM SFO. MAT FAILED WITH MSGS 23-68801 23-60571. L SDU HAS INTERNAL FAILURE. REPLACED SDU PERFORMED SELF-TEST OF SYSTEM, OPERATIONS CHECKED NORMAL IAW AMM.SDR CALA2013092391366Connector · looseR4 DOOR INTERPHONE INOPERATIVE. ACCOMPLISHED DATABASE & QUICK TESTS, NO FAULTS. FOUND CONNECTOR D00280P ON GALLEY A 3 WHEN LOOSE.SDR CALA2013092591423Charger · faultyBATTERY STATUS MESSAGE, REPLACED BATTERY IAW 24-31-01 & MAIN BATTERY CHARGER IAW MM 24-31-02.SDR CALA2013092691487Pump · inoperativeEICAS STATUS MESSAGE APU DISPLAYED. ACCOMPLISHED TROUBLESHOOTING IAW MAINTENANCE MESSAGE 49-07950, FOUND APU DC PUMP INOPERATIVE. ITEM DEFERRED IAW MEL 2825B PULLED CB P310B1 & INSTALLED COLLAR. REPLACED APU DC FUEL PUMP, CHECKED GOOD.SDR CALA2013092491419Unknown · faultyFLIGHT CREW COULD ONLY UPLOAD SOME DATA, BUT NOT ALL. CYCLED AIMS LT & RT CIRCUIT BREAKERS. REPLACED CENTER RADIO TUNING PANEL AS PRECAUTION, OPERATIONS CHECKED GOOD.SDR CALA2013092491418Transceiver · faultyVHF DATALINK FAILED AT THE GATE. MAINT RESET ONCE, FAILED AGAIN. REPLACED CENTER VHF COMM TRANSCEIVER IAW AMM, OPERATIONS CHECKED GOOD.SDR CALA2013092491415Headset · defectiveCAPTAIN`S HEADSET WONT TRANSMIT. REPLACED WITH SPARE HEADSET, SPARE WORKS OK. REPLACED SPARE MINITEL.SDR CALA2013092391365Control Unit · inoperativeWINDOW HEAT RT FWD STATUS MSG. RT FWD WINDOW HEAT INOPERATIVE LT. REPLACED WINDOW HEAT CONTROL UNIT IAW MM.SDR CALA2013092391356Pitot Head · malfunctionedHEAT PITOT LT LOSS OF LEFT PITOT HEAT. REPLACED LT PITOT IAW MM 34-11-01. NO LEAK FOUND & GROUND TEST PASSED.SDR CALA2013092391341Probe · faultyRT TANK INDICATED 3000 LBS LOW FOR AN EXTENDED PERIOD OF TIME BEFORE RETURNING TO NORMAL. SNAPSHOT OF EVENT SHOWED PROBES 14 & 16 IN RT TANK INDICATING 0 VS LT TANK OF 5.4 & 19.1. AFTER FUEL QUANTITY RETURNED TO NORMAL NR 16 PROBE INDICATED SIMILAR TO RT SIDSDR CALA2013092391339Charger · faultyMAIN BATTERY CHARGING AT 10 AMPS-28VDC INDICATED. MAIN BATTERY NOT CHARGING MORE ON GROUND. REPLACED BATTERY CHARGER IAW MM 24-31-02 AS PRECAUTIONARY.SDR CALA2013092391344Control Unit · faultySTATUS MESSAGE HYD ADP C1 MESSAGE APPLIED MEL. PUMP VERIFIED OFF WITH SWITCH OFF. ACCOMPLISHED ACP FIM 29-11 TASK 840 FOR MESSAGE 29-11020. REPLACED C1 ADP LOGIC SPEED CONTROL UNIT IAW MM.SDR CALA2013092391343Acm · faultyPACK MODE RT SMOKE & ELECTRIC SMELL IN CABIN. FOUND DURING TROUBLE SHOOTING ACM PACK RT AT FAULT. THIS CAUSED SMOKE IN CABIN. AFTER ACM PACK RT REPLACED RUN ALL PACKS 1.0 HR. NO SMOKE OR ELECTRIC SMELL IN CABIN NOTED. SYSTEM OK FOR SERVICE.SDR CALA2013092391340Nut · looseEGT PROBES RT ENGINE CH A SIGNAL IS OUT OF RANGE. TIGHTEN LOOSE NUTS ON EGT PROBE IWA 77-21-01. ACCOMPLISHED ENGINE RUN NO OTHER DISCREPANCIES OR ACTIVE FAULTS INDICATED.SDR CALA2013092491417Panel · faultyGREEN LIGHT IN CAPTAIN VHF-LT BUTTON ON RADIO TUNING PANEL IS INOPERATIVE. REPLACED RADIO TUNING PANEL LT, OPERATIONS CHECKED INCLUDING TX & RX TESTED OK.SDR CALA2013092091291Apu · faulty"APU CONTROL" MESSAGE ON EICAS. REPLACED THE APU. OPERATIONS CHECKED GOOD.SDR CALA2013092091290Apu · faultyAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF ONE ARINC 629 CHANNEL. REPLACED APU ASSEMBLY IAW AMM.SDR CALA2013092391342Hydraulic Line · leakingHYD QUANTITY LOW CENTER HYD SYSTEM LOW RESERVOIR QUANTITY. QTY < .40 ADVISORY MSG01- ACTIVE APPROACH HARD; RESERVOIR CENTER FLUID QUANTITY IS LOW. HYDIM CL MSG-2910150 ACTIVE AP HARD. IAW TO IPC 32-51-80-005 ITEM 40 HYD HOSE LEAKING. REPLACED HYD HOSE & SSDR CALA2013091191197Exciter · failedLEFT ENGINE FAILED TO IGNITE USING IGNITER 2. STATUS MESSAGE 7461501 INACTV ES MODE. EXAMINED NR 2 IGNITER CHECKED FROM IGNITER PLUG TO ERU, NO FAULTS FOUND IAW WDM74-11-71. REPLACED EXCITER, LEAD & PLUG IAW AMMS. ACCOMPLISHED IGNITER AUDIBLE TEST &TWO SUSDR CALA2013091091158Controller · failedLT EAI VALVE FAILURE TO THE CLOSED POSITION OR LT EAI CONTROL CARD FAILURE. ADVISORY MSG01- LATCHED DESCENT MODE DEPENDENT; EAI VALVE LT IS FAILED IN CLOSED POSITION. DB- ACIPS CONTROL CARD, LT EAI CARD MSG02- LATCHED DESCENT MODE DEPENDENT; EAI VALVE LT IS SDR CALA2013091091157Weu · faultyWEU CHANNEL L2 STATUS MSG. REPLACED WEU, OPERATIONS CHECKED NORMAL.SDR CALA2013091091184Connector · corrodedENGINE SLOW TO SHUT DOWN ON ARRIVAL & ENG FUEL VALVE STATUS MESSAGE DISPLAYED. MAINT MESSAGE 73-60211 IAW FIM 73-22 TASK 801. ACCOMPLISHED WIRING CHECKS, INCORRECT VOLTAGE NOTED AT FMU CONNECTOR DM76001C. FOUND HIGH RESISTANCE BETWEEN D71074P ENGINE RT CORESDR CALA2013090991134Pressure Switch · faultyENGINE FUEL FILTER RT DIFFERENTIAL PRESSURE ACROSS RT FUEL FILTER APPROACHES BYPASS CONDITION. STATUS MSG01- NOT ACTIVE DESCENT INTERMITTENT; FUEL PUMP FILTER DIFFERENTIAL PRESSURE SWITCH RT ENGINE SIGNAL IS OUT OF RANGE. DB- ELECTRONIC ENGINE CONTROL RT ENSDR CALA2013090991132Shutoff Valve · failedBLEED HIGH PRESSURE SHUTOFF VALVE RT ENGINE BLEED HIGH PRESSURE SHUTOFF VALVE FAILED OPEN OR CLOSED, OR RT AIR SUPPLY & CABIN PRESSURE CONTROLLER FAILURE. LATCHED DESCENT MODE DEPENDENT; HIGH PRESSURE SHUTOFF VALVE RT FAILED CLOSED. DB- AIR SUPPLY & CABIN PRESDR CALA2013090991115Pressure Switch · faulty"ENG FUEL FILTER 'L EICAS, RTFL FAULT CODE 73-60921. FOUND MSG73-60921, FIM 73-34 TASK 803. REPLACED CANNON PLUG DS73001 BUT STILL INTERMITTENT. FINALLY FOUND PREVIOUS REPLACED DIFF PRESS SW AT FAULT. PIN A TO GND HAS ONLY 1 HOM, IT SHOULD BE ISOLATED, REPLSDR CALA2013090991133Switch · brokenFUELER REPORTS UNDERWING FUELING PANEL RT MAIN TOGGLE SWITCH IS BROKEN. REPLACED FUELING PANEL IAW MM.SDR CALA2013090991117Sensor · dirtyATSCV SHOWS OPEN WHILE APU IS RUNNING. CLEANED CLUSTER PNENMATIC SENSORS RAN APU, ALL CHECKED NORMAL.SDR CALA2013090991116Repair · debondedNR 2 ENGINE INTAKE RUB STRIP-5 O'CLOCK POSITION. PREVIOUS REPAIR DISBONDED LESS THAN 3 INCHES. CARRIED FWD IAW THE AMM & TOMC FOR 500 HOURS OF 200 CYCLES. IF UNABLE TO REPAIR PLEASE UPDATE WITH TIME & PARTS REQUIRED.SDR CALA2013090991096Indication Sys · faultyDURING FUELING UNDERWING MAIN QUANTITY FLASHES. FLIGHT DECK INDICATOR OK. SHOULD READ TOTAL QUANTITY UNDERWING INDICATOR. INOPERATIVE IAW MEL. MEL IAW 2821AB. PARTS: 483-9211 MR28347.
Back to Boeing 777-222