Boeing 777-222
Service difficulty reports · 9,718
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013032501814Charger · failedMAIN BATTERY DISCHARGED. MAIN BATTERY DISCHARGING OR HOT BATTERY BUSS NOT POWERED. REPLACED MAIN BATTERY CHARGER AS PER AMM, INSTALLATION TEST PASSED.SDR UALA2013032201804Shutoff Valve · faultyCREW REPORTS LOWER LOBE CREW REST AREA AIR FLOW CHIME SOUNDING CONTINOUSLY, UNABLE TO RESET. LOWER LOBE CREW REST SOV LOCKED OUT PER MEL. POSSIBLE HOT AIR TYPE ODOR IN AREA OF DOOR 3R. RECIRC FANS TURNED OFF & ODOR DID DISSIPATE SLIGHTLY. REPLACED RELAY K2SDR UALA2013032101780Controller · faultyWINDOW HEAT RT FWD, EICAS MESSAGE ON ARRIVAL. REPLACED RT FWD AND LT SIDE WINDOW HEAT CONTROLLER PER MM. ACCOMPLISHED MAST TEST, ALL OPS NORMAL.SDR UALA2013032101765Gcu · faultedAPU GEN WON`T GO ONLINE. REPLACED APU GCU PER AMM AND AUX PWR BREAKER (C24335). INSTALLATION TEST PASS. SOFTWARE CONFIG CHECKS WITH PROPER SOFTWARE. NO FAULTS NOTED.SDR UALA2013032101778Line · leakingON ARRIVAL, FOUND HYDRAULIC FLUID LEAKING FROM AREA AROUND TOP ON LEFT MAIN LANDING GEAR. FOUND FLEX BRAKE LINE LT MLG ANTI SKID SHUTTLE VALVE MODULE LEAKING. REPLACED FLEX HYDRAULIC LINE. LEAK CHECKED OK.SDR UALA2013032101777Thermocouple · faultyDURING EEC SYS TEST FAULT MAINTENANCE MESSAGE 73-51082 OCCURRED MORE THAN ONCE IN LEG 0 THROUGH 5. T3 THERMOCOUPLE PROBE RT ENG, CHANNEL B. REPLACED T3 THERMOCOUPLE.SDR UALA2013032001707Connector · failedSCREWS FOR CONNECTORS BROKE DURING REMOVAL. REPLACED CONNECTOR. OPS CHECKED GOOD IAW AMM 24-09-00.SDR UALA2013032101779Control Panel · inoperativeCAPTAIN`S RADIO TUNING PANEL HAS HR RIGHT MICROPHONE SWITCH LIGHT INOPERATIVE. REPLACED CAPTAIN`S RADIO TUNING PANEL WITH SECOND OBSERVER PANEL.SDR UALA2013032001708Actuator · failedLEFT ENGINE HIGH PRESSURE TURBINE CASE COOLING ACTUATOR IS STUCK OR REVERTED TO ITS FAIL/SAFE POSITION. REPLACED NR 1 ENGINE TCC ACTUATOR. RECONNECTED AND RIGGED TCC CONTROL. REPINNED CONNECTOR DM75004 TO NORMAL POSITION. PASSED GROUND TEST 15 AND 3.SDR UALA2013031801640Smoke Detector · false activationSTATUS MESSAGE "DET FAN 2 CARGO FWD" DISPLAYED. ACCOMPLISHED MAT TEST IAW MM 26-16-01, NO FAULTS.SDR UALA2013032101781Valve · faultyLEFT PACK ECONOMY COOLING VALVE IS NOT IN COMMANDED POSITION. REPLACED THE COOLING VALVE AND TESTED OK.SDR UALA2013031801659Shutoff Valve · malfunctionedPRSOV R STATUS MESSAGE. REPLACED CONTROLLER FOR CABIN AIR SUPPLY. EXAMINED PRSOV SENSE LINES PER FIM 36-11 TASK 805. UNLOCKED VALVE. BLEW OUT SENSE LINE. WRENCHED CHECKED SENSE LINE 'B' NUTS. GROUND RAN RT ENG PER JRH 2-2-1. MAT SHOWS PRSOV NOT ACTIVATESDR UALA2013031801642Circuit Card · failedRECIRCULATION FAN EICAS MESSAGE. MAINTENANCE PAGE SHOWS LT LOWER RECIRCULATION FAN AND FWD UPPER RECIRCULATION FAN. ELMS CPU AND SIG CARDS WERE REPLACED.SDR UALA2013031801597Controller · failedBLEED PRSOV R RIGHT ENGINE BLEED PRESSURE REGULATING SHUT OFF VALVE (PRSOV) FAILED OPEN OR CLOSED OR RIGHT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. REPLACED CONTROLLER AND PRSOV, OPS CHECKED OKAY.SDR UALA2013031801599Solenoid · failedFLAPS PRIMARY FAIL PRIMARY (HYDRAULIC) FLAPS DRIVE FAILURE. FLAPS OPERATING IN SECONDARY (ELECTRIC) MODE. CAUTION MSG02- NOT ACTIVE CLIMB MODE DEPENDENT; FLAPS PRIMARY LOW SPEED SOLENOID CIRCUIT IS OPEN. DB- FSEU 2MSG-2720360 ACTIVE CL HARD MSG-2720372 INACSDR UALA2013031501579Oxygen Bottle · dischargedOXYGNE BOTTLE DISCHARGED. REPLACED OXYGEN BOTTLE AMM.SDR UALA2013031501585Isolation Mount · damagedREMOVED OUTBOARD FAN ASSY AND FOUND FORWARD UPPER ISOLATOR MOUNTS DAMAGED ON BOTH. INSTALLED OUTBOARD LAV GALLEY VENTILATION FAN PER AMM, OPS CHECKED OKAY USING MAT SYSTEM TEST.SDR UALA2013031401562Sdu · malfunctionedSATCOM EICAS. STATUS MSG SATCOM SYSTEM MAT SHOWS MAINT MSG 23-60021 SATELLITE DATA UNIT (LEFT) HAS AN INTERNAL FAULT. CB'S P110 E17, E20 AND E21 PULLED AND COLLARED PER MEL PROCEDURES. REPLACED SDU, OPS NORMALSDR UALA2013031501569Sensor · faultyPRIOR TO DEPARTURE, APU AUTO SHUTDOWN TWICE. REPLACED APU OIL TEMP SENSOR PER MM, OPS CHECKED OK, APU MESSAGE CLEARED, MAT MESSAGE NOT ACTIVE. APU OIL FULL. ACFT RETURN TO BLOCKS SECOND TIME. SAME PROBLEM HIGH OIL TEMP DETECTED BY APUC. FOUND 1 X 1.5 HOLSDR UALA2013031501584Windshield · delaminatedNR 1 RIGHT AND LEFT WINDSHIELDS NEED REPLACEMENT. WINDOW LEFT NR 1 DELAMINATING ACROSS TOP. COMPLETED INSTALLATION OF NR 1 RIGHT AND LEFT WINDSHIELDS, IAW MM 56-11-01.SDR UALA2013031401559Fitting · leakingNR 2 ENGINE PDOS INBD FAN COWL ACTUATOR FLEX LINE COUPLING LEAKING AT FIREWALL CONNECTION. LINE ON AOM#Z6066 PCN 125-3173. LINE REMOVED. INSTALLED NEW LINE. STILL LEAKING AT QUICK DISCONNECT. ON AOG #C1034 PCN 120-2249. NEW LINE DISCONNECTED DUE STATIC LSDR UALA2013031401511Bolt · brokenFOUND AIR SENSE LINE FROM PNEUMATIC CLUSTER UNSECURED FROM PLENUM. FOUND STATIC PRESSURE LINE TO PLENUM RETAINING BOLT HEAD BROKEN OFF DURING INSPECTION OF PNEUMATIC CLUSTER AND SENSE LINES ITEM 33. DRILLED OUT BOLT, THREADS NEED TO BE CLEANED UP OR HELI COSDR UALA2013031301485Circuit Card · unknownNEED TO REPLACE SIGNAL COND CARD ASSY IN P110 PANEL. REPLACED SIGNAL COND CARD ASSY.SDR UALA2013031301484Circuit Card · unknownCPU CARD HAS AN INTERNAL FAULT, CMC MESSAGE ACTIVE. REPLACED CPU CARD IN P110 PANEL.SDR UALA2013031401558Thermocouple · faultyENG EEC C1 R DISPLAYED ON STATUS PAGE. DO NOT USE THERMOCOUPLE 280-4257, THE CORRECT PW4090 PCN IS 223-1593. REPLACED 'B' CHANNEL THERMOCOUPLES ON THE 2.9 START STABILITY BLEED VLV 2 EACH AT 2 AND 10 O'CLOCK POSITION ON NR 2 ENGINE IAW AMM.SDR UALA2013031401510Tube · missingDURING INSPECTION, FOUND RIGHT ENGINE STARTER GUIDE TUBE MISSING. REPLACED MISSING TUBE AND HARDWARE.SDR UALA2013031401561Smoke Detector · faultySTATUS MESSAGE DET CHANEL 2 E-E SMOKE. UNABLE TO CLEAR MESSAGE. REPLACED E-E COOLING SMOKE DETECTOR PER AMM, BITE TEST OK PER AMM.SDR UALA2013031401560Controller · faultyAPU BLEED AIR STATUS MSG DISPLAYED AFTER APU START. FAULT CODE LATCHED 495 00 1 00, NO CORRELATED MSGS. APU BLEED AIR STATUS MSG CLEARS AFTER APU SHUT DOWN AND RE-APPEARS DURING START, ALL SYNOPTIC INDICATION AND DUCT PRESSURE NORMAL. REMOVED AND REPLACED ASDR UALA2013031301481Connector · unsecureRIGHT ENGINE WILL NOT START AFTER PUSHBACK. SECURED AND CLEANED CONNECTOR FOR FMU ERU FOR RIGHT SIDE ENGINE. RAN ENGINE, OPS OK.SDR UALA2013031401509Handset · faultyCABIN INTERPHONE INOPERATIVE. REPLACED HANDSET AND CORD IAW MM.SDR UALA2013031201474Fan · failedRECIRCULATION FAN FAILURE OF ONE OR MORE CABIN AIR RECIRCULATION FANS. REPLACED RIGHT RECIRCULATION FAN PER MM21-25-07 P401 AND OPS CHECKED OK. ACP BOTH ENGINE RUNS AND TRANSFERRED POWER FROM DIFF SOURCES, FAN OPS OK.SDR UALA2013031201460Fan · failedRECIRCULATION FAN FAILURE. REPLACED RECIRCULATION FAN PER MM. OPS AND MAT CHECKED OK.SDR UALA2013031201463Electronic Unit · failedNO MID GALLEY POWER, REPLACED ELCU M25135 IN P100 PER AMM 24-51-05, MID GALLEY ELECT POWER ALL NORMAL WITH GROUND POWER. ELCU M25044 IN P100 WAS ALSO REPLACED PER FIM 25-31 TASK 804 FOR MSG 25-31001.SDR UALA2013031201461Relay · failedLAVATORY/GALLEY FAN LEFT FAILED. REPLACED LAVATORY/GALLEY FAN RELAY K21262, REPLACED I-O CARD M24400- A4 IAW AMM 24-09-00-805 & 806-001. OPS CHECKED FAN, PASSED. NO ACTIVE MAINTENANCE OR EICAS MESSAGES.SDR UALA2013031301483Bearing · leakingDUE TO EVIDENCE OF OIL IN NR 4 BEARING AIR SEAL, REPLACED NR 1 ENGINE PER AMM.SDR UALA2013031101446Shutoff Valve · faultyCREW REST LOWER LOWER LOBE ATTENDANT REST SHUTOFF VALVE IS NOT IN THE COMMANDED POSITION. REPLACED SHUTOFF VALVE PER MM, OPS CHECKED GOOD AND NO LEAKS. ALL MESSAGES CLEAR AND TEST PASSED.SDR UALA2013031101451Solenoid Valve · faultyRIGHT GEAR DOOR WILL NOT CLOSE USING GROUND CONTROL SWITCH. REPLACED SAFETY SOLENOID VALVE, OPS CHECKED NORMAL. NO LEAKS NOTED. SERVICED HYD FLUID.SDR UALA2013031301497Seal · leakingDUE TO EVIDENCE OF OIL IN NR 4 BEARING AIR SEAL, REPLACED NR 1 ENGINE PER AMM.SDR UALA2013031101447Actuator · leakingLEFT HYDRAULIC SYSTEM SHOWED 60 PERCENT ON TD. FOUND HYD FLUID LEAKING FROM RUDDER MID PCU DYNAMIC SEAL MORE THAN NORMAL LIMIT BUT LESS THAN DISPATCH LIMIT PER AMM, WITH SYSTEM PRESSURIZED. LEFT HYD SYSTEM SERVICED TO FULL. ACFT CONTINUES TO SERVICE MAXIMUMSDR UALA2013031101437Valve · faultyDURING REFUELING BOTH WING TANKS INBD VALVES AND CENTER TANK LEFT VALVE WOULDN'T OPEN. DEFERRED CENTER LEFT REFUEL VALVE. APPLIED STICKER. REFER LOG 3 AND LOG 4 FOR LEFT WING INBD VLV AND RIGHT WING INBD VLV RESPECTIVELY.SDR UALA2013031101438Module · faultyAFTER ENGINE STAR CREW HAD GROUND PROX ADVISORY MSG ALONG WITH TERRAIN SYS STATUS MSG. REPLACED CORE PROCESSOR MODULE GRAPHICS GEN. LOADED SOFTWARE, OPS CHECK OKAY.SDR UALA2013030601332Indicator · faultySTANDBY ALT KEEPS FLICKERING AND RESETS TO LOCAL-ALT SETTING. REPLACED INDICATOR.SDR UALA2013030601336Circuit Card · malfunctionedRECIRCULATION FAN STATUS MESSAGE. RESEATED "M24400-A16" FILTER MODULE CARD IN P110 -- REF SSM 21-25-11 & 24-09-03 PG 101 SHEET 2 AND FIM 21-25 TASK 807 PG 217. ACCOMPLISHED GROUND TEST, RECIRCULATION FAN SYS TESTED OK. NO ACTIVE MESSAGES ON MAT.SDR UALA2013030501321Controller · faultyCABIN TEMP REFERENCE IS BLANK ZONE B. REPLACED TRIM VALVE PER MM, OP CHECKED GOOD. CHECKED ALL WIRES FROM CTC TO ZONE 'B' TRIM AIR MODULATING VALVE, CHECKED GOOD. SWAPPED VALVE WITH KNOWN GOOD VALVE, CHECKED GOOD. CONFIRMED BAD VALVE. RESET CTC AND OPERASDR UALA2013030501306Line · chafedDURING VISUAL INSPECTION, FOUND CLAMP CHAFING INTO NR 4 BEARING SCAVENGE TUBE LR06. REPLACED OIL LINE. FOUR CLAMPS REMAIN TO BE ATTACHED TO 12TH STAGE BLEED DUCT. COMPLETED SECURING CLAMPS ATTACHING NR 4 BEARING SCAVENGE TUBE TO 12TH STAGE BLEED DUCT. ENSDR UALA2013030501305Alternator · faultyLEFT EEC IS IN A 'NO DISPATCH' CONFIGURATION. EEC MAY BE OPERATING WITH A LIMITED SET OF ENGINE CONTROL PARAMETERS AND MAY NOT BE CAPABLE OF CONTROLLING ALL ASPECTS OF ENGINE OPERATION. REPLACED PMA AS PER AMM, ALL OK NOW AFTER ENG OPERATION.SDR UALA2013030401296Idg · leakingRIGHT IDG FAULT, LOW INTERNAL OIL PRESSURE. FOUND OIL LEAK FROM BOSS FILTER ON OUTSIDE OF IDG. REPLACED RIGHT IDG IAW MM, CHECKED OKAY. ACCOMPLISHED IDG POWER PLANT TEST AND IDG OPERATIONAL TEST ALL OKAY.SDR UALA2013030401271Sleeve · crackedNR 2 ENGINE HAS CRACKED BLUE TERMINAL SLEEVE AT IDG TERMINAL BLOCK. FOUND BLUE SHRINK TUBING ON UPPER & LOWER IDG CABLES.SDR UALA2013030401265Vane · damagedNR 2 ENGINE HAS 1 STG VANE ID PLATFORM FILLET RADIUS BURN THRU LOCATED 3 O'CLOCK POSITION THAT EXCEEDS ADDITIONAL REDUCED INSPECTION LIMITS PER MM 72-00-00. REPLACED NR 2 ENGINE IAW AMM.SDR UALA2013030401264Oxygen Mask · damagedFIRST OFFICERS O2 MASK HAS BROKEN 100%-N SWITCH. REPLACED FIRST OFFICERS O2 MASK PER AMM35-11-18 PG 201.
Back to Boeing 777-222