What was found
NR 2 ENGINE PDOS INBD FAN COWL ACTUATOR FLEX LINE COUPLING LEAKING AT FIREWALL CONNECTION. LINE ON AOM#Z6066 PCN 125-3173. LINE REMOVED. INSTALLED NEW LINE. STILL LEAKING AT QUICK DISCONNECT. ON AOG #C1034 PCN 120-2249. NEW LINE DISCONNECTED DUE STATIC LEAK. REMOVED QUICK DISCONNECT REF IPC 71-12-51 ITEM 150. REMOVED AND REPLACED QUICK DISCONNECT FITTING AT TOP OF I/B PDOS FLEX LINE. OPS AND LEAK CHECK GOOD IAW MM.