Boeing 777-224
Service difficulty reports · 1,592
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777224' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026022314000Charger · failedR3 DOOR EMERGENCY LIGHT BATTERY CHARGER TEST TO FAILED. EMERGENCY LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026022313998Charger · failedL2 DOOR EMERGENCY LIGHT BATTERY CHARGER TEST FAILED. EMERGENCY LIGHT BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06,SDR CALA2026022313981Fitting · crackedREF EA 5510-01896 REV C OP 011 ACCOMPLISH, PLEASE ACCOMPLISH EA 5510-01896 REV C OP 009 LH ELEVATOR OUTBOARD ACTUATOR FITTING ASSEMBLE REMOVAL AND REPLACEMENT G2 REFER HX NR CR. 6168114 AND ORIGINAL BY V940359 ENTERED THE ESFR FOR EA 5510-01896 REV C OP 09, WASDR CALA2026022013936Fitting · crackedREFER EA 5510-01896 OP 007, NDT INSPECTION FOUND LT ELEVATOR INBD ACTUATOR FITTING CRACK AT LOCATION E, LT ELEVATOR INBOARD ACTUATOR FITTING ASSEMBLY - REMOVE AND REPLACEMENT G2 - OP 11 ACCOMPLISHED RII INSPECTED AND OKAY.SDR CALA2026021713849Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY - ELECTRICAL CHARGE CHECK (PED 1, 2, 3, 4) EPAS BATTERY ELECTRICAL CHARGE CHECK - EPAS BATTERY DOESNT BLINK. REQUIRES BATTERY REPLACEMENT REPLACED 9V BATTERY PACK IAW AMM TASK 52-11-20-400-806-002.SDR CALA2026021613777Oven · odorPILOT STATES APROX 10 MIN UNTIL LANDING RECEIVED CREW REST SMOKE FD EICAS MESSAGE WITH AURAL ALARM IN CREWREST SPACE. NO FIRE/SMOKE INDICATIONS ON THE FLIGHT DECK. REPEAT FROM PREVIOUS WRITEUP FROM LAST FLIGHT. UPDATED SDR INFO AND ADDED PICS UPDATED SDR INFO SDR CALA2026021613771Smoke Detector · false activationDUE TO RECENT REPORTS OF LOWER PILOT CREW REST SMOKE DETECTOR ALARMING WITH NO EVIDENCE OF SMOKE/FUMES, REPLACED FLIGHT CREW REST LOWER SMOKE DETECTOR PER TECH SUPPPORT REQUEST. REF AMM 26-14-11. OPS CHECK GOOD.SDR CALA2026021813898Battery Pack · inoperativeDOOR 4R EPAS BATTERY PACK ASSY. INOPERATIVE WHEN REINSTALLING IAW WORK CARD 26-5211-9-9003. REMOVED AND REPLACED DOOR 4R EPAS BATTERY PACK IAW AMM 52-11-20. OPS TESTED OK.SDR CALA2026021213737Battery Pack · inoperativeEMERGENCY SIDEWALL LIGHT AT 2R AFT DOOR INOPERATIVE. CONFIRMED. R & R THE BATTERY PACK IAW 33-51-06-960-802, CHKD OK.SDR CALA2026021213735Battery Pack · inoperativeEMERGENCY CELLING LIGHT AT THE L3 DOOR INOPERATIVE, CONFIRMED. R & R THE PACK BATTERY IAW 33-51-06-960-802, CHKD OK.SDR CALA2026021213738Snubber · out of alignmentL4 DOOR DAMAGED, & OUT OF ALLIIGNMENT, NOT ABLE TO CLOSE, SUSPECT CONTACT WITH SERVICE TRUCK. VERIFIED DOOR 4L LATCHES IN DOWN POSITION WHILE DOOR IS OPEN WITH NO BINDING BUT EPAS GETS STUCK WHEN TRYING TO OPERATE DOOR. SUSPECT EPAS OR SNUBBER BINDING WHEN CSDR CALA2026021013645Converter · odorBURNING ODOR, FL250, SMOKE ODOR IN ACFT, VERY FAINT ODOR BRIEFLY THEN DISAPPEARS, OCASIONALLY REAPPEARS. IAW MM 05-51-58-800, RAN BOTH PACKS INDIVIDUALLY & TOGETHER WITH BOTH ENGINES & APU, REMOVED BOTH OZONE CONVERTERS, INSPECTED INSIDE & REINSTALLED, SDR CALA2026020413584Charger · failedR2 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY AND BATTERY CHARGER WERE REPLACED AND CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2026020213509Charger · failedL3 DOOR M33406 LT BATTERY CAPACITY CHK FAILED. IAW HX NR WO.6102589, THE EMERGENCY LIGHT BATTERY AND BATTERY CHARGER REPLACED & CHECKED NORMAL IAW AMM 33-51-06.SDR CALA2026020213510Battery · no testL1 DOOR M33424 EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. REF HX NR WO.6102595.SDR CALA2026020613616Not Reported · not reportedREJECTED TAKEOFF AT 50 KTS, CREW REPORTED REJECTED TAKE OFF AT LOW SPEED. NO HIGH ENERGY STOP CONDITIONS OBSERVED. OK FOR SERVICE IAW AMM 05-51-14-210-801.SDR CALA2026020213519Girt Bar · no discrepancyL1 & R3 DOORS YELLOW GIRT BAR INDICATING FLAG NOT FULLY VISIBLE. INSPECTED THE DOOR GIRT BAR INDICATION FLAGS WHILE FLIGHT ATTENDANTS ARMED DOOR. NO FAULT FOUND. FLAGS ARE IN VIEW. DOORS CONFIRMED ARMED IAW AMM 52-11-00. NO FURTHER MX ACTION REQUIRED.SDR CALA2026013013454Oven · dirtyPERFORM CONDITIONAL INSP IAW AMM TASK 05-51-58-800-801-C3, ACCOMPLISHED CONDITIONAL INSPECTION IAW AMM 05-51-58-800-801-C3. NO SIGNS OF ARCHING OR BURNING. UPON FURTHER VISUAL AND OPS INSPECTION, FOUND OIL ON BOTTOM INTERIOR OF OVEN AND ON HEATING ELEMENT OFSDR CALA2026012613316Bustle · damagedSLIDE COVER AT DOOR 3R HAS A HOLE IN THE TOP RIGHT CORNER AREA OF COVER OF ESCAPE SLIDE. ECRA 2560-03761 PART 1 PERFORMED SATISFACTORY. PART 2 INSPECTION REQUIRED EACH FC. PART 3 PERMANENT REPAIR REQUIRED IN 2 FC INTERIM REPAIR PART1 PER ECRA 2560-03761 ACCOMSDR CALA2026012613258Smoke Detector · false activationSMOKE CREW REST & FLT DECK, ACCOMPANIED BY AN ALARM NO SMOKE OR FUMES NOTED FLT CREW REST SMOKE DETECTION, OPS TEST PERFORMED IAW AMM: 26-14-10-710-801 REV 106.TEST SATIS. NO MESSAGE AT CSCP.SDR CALA2026012713330Battery · no testEMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026012713329Charger · no testEMERGENCY LIGHT BATTERY CHARGER TEST FAILED. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026012713328Battery · no testEMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026012713327Battery · no testEMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026012713326Battery · no testEMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE BATTERY WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026012013104Elec Connector · dirtyDOOR 2R SLIDE/OVERWING LIGHT INOP CLEANED POWER SUPPLY M33098 WIRE CANNON PLUG DM33098 REF WDM 33-51-42 AND SWPM 20-10-04.SDR CALA2026011913080Acm · overtempDIRTY SOCK/OIL OODR IN FLIGHT DECK WITH LEFT PACK OFF AND RIGHT PACK ON ODOR FADES AWAY. WITH LT PACK ON AND RT PACK OFF ODOR COMES BACK. FOUND MAINTENANCE MESSAGE 21-21191 AND 21-23401 LATCHED. LT PACK OPS FOR ABOUT 5 MINS & SHUTSDOWN DUE TO OVERTEMP. SUSPECSDR CALA2026011913081Light · faultedCHRONIC LVL 1 HIST OF FLT DECK ENTRY LIGHT NOT WORKING CORRECTLY. EXHAUSTED FIM 33-22 TASK 809. CLEARANCE BETWEEN SWITCH SENSORS IS WITHIN LIMITS. LIGHT IS CURRENTLY ON. REF SDS 33-22-00-005, ENGINES HAVE TO BE RUNNING FOR LIGHT TO GO OFF WHEN FLIGHT DECK DOOSDR CALA2026011512975Oil System · lowRIGHT ENG OIL QTY 0 QTS, OIL PRESS HOVERING AROUND 20 PSI. NR 1 ENGINE IS THE DISCREPANT ENGINE. INITIAL OIL SVC ACCOMPLISHED. ADDED NR 1 ENG 26QTS, AND NR 2 ENG-4QTS. 40 MIN IDLE RUN CARRIED OUT PER TEST NR 5 IDLE LEAK CHECK IAW AMM 71-00-00-700-805-G00. ASDR CALA2026010912833Battery Pack · inoperativeWHEN SET THE EMERGENCY LIGHT SWITCH TO THE ON MODE,FND M33094 POWER PACK CAN NOT STAY ON FOR 15 MINUTES REFER HAECO NON-ROUTIN E LOG PAGE:9492061,ORIGINATED BY EMP:V903529 ORIGINATING CARD:23 -3350-1-0001. REPLACED M33904 POWER SUPPLY BATTERY AND CARRY OUT OPSDR CALA2026010912830Battery Pack · no testOPERATIONAL TEST FOUND L1 DOOR M33302 BATTERY PACK INOPERATIVE. REPLACED THE L1 DOOR BATTERY PACK AND CARRY OUT OPS TEST IAW AMM 33-51-06-960-802, REV 106. RESULT WAS NORMAL.SDR CALA2026010912829Battery Pack · no testOPERATIONAL TEST FOUND R4 DOOR, POWER PACK BATTERY INOP. REPLACED THE R4 DOOR M33408 POWER PACK BATTERY AND CARRIED OUT OPS TEST IAW AMM 33-51-06-960 -802, REV 106, THE RESULT WAS NORMAL BATTERY R4 M33408 PACK INOP.SDR CALA2026010912825Heat Shield · crackedONE MLG TIRE FOUND BEYOND AMM LIMITS. MLG NR 1 WHEEL, HEAT SHIELD CRACKED, NR 1 MLG WHEEL ASSY REPLACED IAW AMM 32-45-01/401.SDR CALA2026010712732Battery · no testL3 DOOR EMERGENCY LIGHT BATTERY M33405 CAPACITY CHECK FAILED. THE BATTERY M33405 WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026010712731Charger · faultedR1 DOOR EXT EMERGENCY LIGHT FOUND DIM. R1 DOOR EXT EMERGENCY LIGHT LAMP AND BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-05 AND AMM 3 3-51-06.SDR CALA2026010712730Battery · no testDOOR L3 EMER LIGHT BATTERY M33400 CAPACITY CHECK FAIL. DOOR L3 EMER LT BATTERY M33400 REPLACED AND TEST NORMAL IAW AMM 33-51-06.SDR CALA2026010712729Battery · no testDOOR 4L EMER LIGHT BATTERY M33407 CAPACITY CHECK FAIL. DOOR 4L EMER LT BATTERY M33407 REPLACE AND TEST NORMAL IAW AMM 33-51-06.SDR CALA2026010912852Anti-Ice Valve · failedANTI ICE ENG L EICAS, LT ENG ANTI ICE VALVE DEACTIVATED IN OPEN POSITION WITH KIT WAITING FOR DEFERRAL. APPROVES MEL 3021T LT EAI VALVE DEACTIVATED OPEN WITH KIT DEFERRED EAI VALVE DEACTIVATED IN OPEN POSITION IAW AMM 30-00-00-040-809-001.SDR CALA2026010612701Power Supply · inoperativeOPERATIONAL TEST FND DOOR NO.4 R/H M33409 BATTERY PACK INOP. POWER SUPPLY REPLACED AND TESTED NORMAL IAW AMM 33-51-06-960-803 REV.105SDR CALA2026010212605Skin · damagedLIGHTNING STRIKE DAMAGE AT STA 845 AND BETWEEN S-27 - S-28 BETWEEN S-28 AND S-29 ACPD CONDUCTIVITY CHECK ON HEAT DAMAGED AREA. FOUND DAMAGE AREA AVERAGE READING OF 45. READING OF 38 AT POINT OF IMPACT. REMOVED THE EXISTING FASTNERS AND CUT OUT DAMAGED PART OF SDR CALA2025123012514Elec Connector · looseSMOKE REST UPPER DOOR 3 EICAS, FOLLOWED CHECKLIST, NO SMOKE FA & PILOTS REPORTED SMOKE ALARM WENT OFF IN CREW BUNK AREA. IT WAS RESET PER FAOM BUT A RED LIGHT ON SWITCH STAYED ILLUMINATED. PILOTS ALSO NOTICED THE LISTED EICAS FILED. NO SMOKE OR FIRE JUST HESDR CALA2025121912269Battery · inoperativeEMERGENCY POWER ASSIST SYSTEM (EPAS) RESERVOIR PRESSURE LEVEL CHECK PROCEDURE, R4 DOOR, EPAS BATTERY PACK GREEN TEST LIGHT INOPERATIVE. REPLACED EPAS 9V BATTERIES AT R4 DOOR IAW AMM 52-11-20-400-806-002. OPS CHECKED GOOD.SDR CALA2025122212309Engine · failedLEFT ENGINE FAILURE ON TAKEOFF. NR 1 ENGINE REMOVED AND REPLACED IAW TASK CARDS 25-0571-8-0052 AND 23-7100-1-4817. LEAK CHECKED. AIRCRAFT OK FOR SERVICE.SDR CALA2025121612173Battery Pack · no testDURING OHAR EMERGENCY LIGHT TEST, LIGHTS DO NOT TURN ON. BATTERY PACK REPLACED IAW TASK 33-51-15-800-801-C5. TEST PERFORMED OK IAW TASK 33-51-15-800-801-C3.SDR CALA2025121012010Smoke Warning · false activationDURING DESCENT, RECEIVED A SMOKE REST UPPER DOOR 3 NON NORM CHECK..NO SMOKE, PERFORMED ALL TEST & T/S IAW FIM TASK 26-14, TASK 809. R & R OEU BY DOOR 3R, IAW AMM 23-33-02-400-803. OPS CHECKED GOOD. NO FAULT NOTED. NO SMOKE NOR ODOR FOUND IN THE UPPER REST ASDR CALA2025120811897Battery · no testR4 DOOR EMERGENCY LIGHT BATTERY M33408 CAPACITY CHECK FAIL. BATTERY M33408 REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2025120811895Battery · no testR4 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. BATTERY REPLACED AND TESTED NORMAL IAW AMM 35-51-06.SDR CALA2025120811893Charger · no testR4 DOOR EMERGENCY LIGHT BATTERY CHARGER FAILED TO TEST. BATTERY CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2025120811891Battery · no testL3 DOOR EMERGENCY LIGHT BATTERY M33405 FAILED CAPACITY CHECK. BATTERY M33405 REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2025120811855Fan · seizedPER VERBAL FROM THE CAPTAIN, ELECTRICAL, ACRID ODOR IN CABIN AND FLT DECK. NO VISIBLE SMOKE NOTED. CONDITIONAL INSPECTION CARRIED OUT IAW AMM 05-51-58-800-801-C3, UP TO & INCLUDING BLOCK 1. B. NO DEFECTS NOTED BY CREW IN DE-BRIEFING, RECIRC FAN STATUS MESSA
Back to Boeing 777-224