Boeing 777-300ER
Service difficulty reports · 456
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '777300ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024102302717Battery · no testCABIN: R/H DOOR 2 AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33097 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302716Battery · no testCABIN: R/H SEAT 9-22 CEILING EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33304 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302715Battery · no testCABIN: L3 DOOR AREA EMERG LT CAPACITY TEST FAIL. EMER LT PWR PACK M33301 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302714Battery · no testCABIN: SEAT 30-43 CEILING EMERG LT CAPACITY TEST FAILED. EMER LT PWR PACK M33303 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302707Battery · no testCABIN: SEAT 9-16 FLOOR PROX LT CAPACITY TEST FAIL EMERG LT PWR PACK M33096 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102302706Battery · no testCABIN: DOOR 2 AREA & FWD ZONE R/H EMERG LT CAPACITY TEST FAIL. EMERG LT PWR PACK M33094 REPLACED AND TEST NORMAL AS PER AMM 33-51-06.SDR CALA2024102100885Indicator · faultyTIRE PRESS EICAS STATUS ABNORMAL TIRE PRESSURE CONDITION EXITS DEFINED AS: 1) ANY MAIN O R NOSE GEAR TIRE PRESSURE IS LESS THAN LOW PRESSURE THRESHOLD OR 2) ANY MAIN GEAR TIRE PRESSURE DEVIATES FROM THE AVERAGE MAIN G EAR TIRE PRESSURE BY MORE THAN A MAXIMUM ASDR CALA2024102202701Skin · damagedREF LOG PAGE 9352203 AND ENGINEERING REQUEST REMOVE PAINT AND BLIND FASTENER AT PREVIOUS LIGHTNING STRIKE REPAIR STATION 2018. REMOVED PAINT, BLIND FASTENER AND CREATED GRID MAP STA 2018 REF CONFIRMED HOLE SIZE IS .199" MEASURED DISTANCES FROM FRAMES AND STRINSDR CALA2024101400833Unknown · odorSTRONG SMELL OF ELECTRICAL BURN AFTER ENGINE SHUT DOWN T/S ACC EC/RA 0500-01016 REV H PERFORMED.INSPECTION ACC AMM 05-51-58-800-801-C3 REV 101 C/OUT. ENG GROUND RUN PERFORMED BY FLT CREW. PACKS OPERATIONAL TEST SATISFACTORY.FOUND NO SMELL/ODOR IN COCKPIT.IN ASDR CALA2024100900800Warning Message · false activationINTERMITTENT DOOR WING SLIDE LK L STATUS MSG FOUND MAINT MESSAGES 52-22360 AND 52-21920 NOT ACTIVE. PER FIM 52-11 TASK 836 AND 52-11 TASK 837 FAULT NOT ACTIVE REF PIC AND NO FURTHER MAINT ACTION REQUIRED.SDR CALA2024100700763Oven · dirtyMID GALLEY OVEN FIRE. REQUEST NEF OVEN 408 OVEN 408 EMITTED SMOKE, CONFIRMED OVEN 408 FOUND WITH CARAMEL ON HEATING ELEMENT/FAN. PERFORMED CONDITIONAL INSPECTION 05-51-58-800-801-C3. ALL OTHER OVENS / COFFEEMAKERS PERFORMED NORMALLY. NOC OK TO DEFER OVESDR CALA2024100300743Idg · faultedOIL QTY DROPPED TO 1 ENROUTE FOUND OIL LEAK FROMRH BUG CASE DRAIN AND RH BUG AGB PAD DRAIN LINE. REPLACED RH BUG AND ACCESAAORY GEARBOX SEALOL FACE SEAL AND PERFORMED HI POWER ENG RUN. NO LEAK FOUND. REF AMM 24-25-01 ,72-64-01.PARTS USED: 78-7921-3-0027,QTY SDR CALA2024101702673Channel · damagedREF LOG PAGE 9352088 STR 1R BETWEEN STA.1350 AND 1371 DAMAGED WHILE REMOVING LIGHTENING STRIKE DAMAGE. REMOVED ADF ANTENA DECAL REF IPC 34-57-02-01 AND REMOVED STRINGER FASTENERS REF SRM 53-00-03. ACPD FPI INSP. ON NEW STRINGER REF NTM 20-20-02 P 8..NO CRACKSSDR CALA2024092600694Relay · faultyDURING XFER GPU POWER TO APU POWER FOUND SEVERAL MSG MAIN BAT CH ARGER AND MAIN BAT CHARGER. XFER POWER TO GPU AND FOUND ALL MSGG ONE. SUSPECT SIU AT FAULT. WILL TRY TO SWAP 2133 SIU. REPALCE THREE SIU STILL NIL HELP PER AMM 24-09-00-000-814-002 AN D AMM 24-09SDR CALA2024092500689Idg · faultyELEC GEN OFF R EICAS ADVISORY RIGHT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL SWITCH OFF, AND ENGINE NOT SHUT DOWN. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2431562 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: GENERASDR CALA2024091602436Battery · no testL4 DOOR EMER LT BATTERY PACK M38405 CAPACITY CHK FAILED. L4 DOOR EMER LT BATTERY PACK M33405 REPLACED AND INSTALLATION TEST C/O NORMAL IAW AMM33-51-06.SDR CALA2024091602435Battery · no testR4 DOOR EMER LT BATTERY PACK M33401 CAPACITY CHK FAILED. R4 DOOR EMER LT BATTERY PACK M33401 REPLACED AND INSTALLATION TEST C/O NORMAL IAW AMM33-51-06.SDR CALA2024091602434Battery · no testL4 DR EMER LT BATTERY PACK M33400 CAPACITY CHECK FAIL TRANSFER REFER NON-ROUTINE. L4 DOOR EMER LT BATTERY PACK M33400 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024082600496Coffeemaker · leakingWATER LEAKING FROM CEILING BETWEEN FWD GALLEY AND 1L. WATER DI DNT STOPPER INBOUND CABIN CREW, LEAKAGE FROM FWD GALLY LT AFT CORNER, WATER NOTICED AT LOWER CORNER NEAR FLOOR. GROUND CHECKED DOOR 1 & FWD GALLEY CEILING AREA, ALL WATER SUPPLY HOSE SECURED & INTSDR CALA2024082200481Indication Sys · faultedAC DIVERSION TO HNL. PILOT REPORTED NR 2 ENG OIL QTY LOSS. ACCOMPLISHED SNIFF CHECK OF OIL FOR FUEL ODOR IN OIL SYS IAW AMM 12-13-01-130-803-002 STEP F. (1). NO FUEL ODOR PRESENT IN OIL. ALSO ACCOMPLISHED TEST NR 6 PART POWER LEAK CHECK REF AMM TASK 71-00-00-7SDR 2024FA0000616Skin · cracked9V-SWB STARTED “A” CHECK IN HANGAR ON 12/08/2024 AND RETURNING TO SERVICE ON 16/08/2024. DURING THE ACCOMPLISHMENT OF THE ADSI IB777570085 LH FIXED TRAILING EDGE UPPER SKIN, FOUND 02-OFF CRACKS ON THE LH UPPER WING SKIN AT FASTENER #5.SDR 2024FA0000615Skin · cracked9V-SWB STARTED “A” CHECK IN HANGAR ON 12/08/2024 AND RETURNING TO SERVICE ON 16/08/2024. DURING THE ACCOMPLISHMENT OF THE ADSI IB777570086 RH FIXED TRAILING EDGE UPPER SKIN, FOUND A CRACK ON THE RH UPPER WING SKIN AT FASTENER #5.SDR 2024FA0000497Shim · migrated9V-SWW STARTED “A” CHECK IN HANGAR ON 11/07/2024 AND RETURNING TO SERVICE ON 15/07/2024. DURING THE ACCOMPLISHMENT OF THE ADSI IB777570078, #7 FLAP SUPPORT FITTING SHIMS WERE FOUND MIGRATED.SDR 2024FA0000496Shim · migrated9V-SWW STARTED “A” CHECK IN HANGAR ON 11/07/2024 AND RETURNING TO SERVICE ON 15/07/2024. DURING THE ACCOMPLISHMENT OF THE ADSI IB777570077, #2 FLAP SUPPORT FITTING SHIMS WERE FOUND MIGRATED.SDR CALA2024062701907Table · inoperative21B TRAYTABLE INOPERATIVE LOCK IN STOW POSITION NEF MEL REF 2520R DEFER USING NEF MEL REF 2520R DEFER USING NEF MEL 2520R LOCKED IN STOWED POSITION NOC DESK: OM NAME: CS DATE: 23-JUN-24- APPROVED NEED CABLE PNSDR 2024FA0000429Skin · cracked9V-SWK IS CURRENTLY IN HANGAR FOR C06 CHECK. DURING THE ACCOMPLISHMENT OF ALERT SI: IB777570086(RH FIXED TRAILING EDGE UPPER SKIN), FOUND CRACK ON RHW UPPER WING SKIN AT #5 FASTENER HOLE.SDR 2024FA0000428Skin · cracked9V-SWK IS CURRENTLY IN HANGAR FOR C06 CHECK. DURING THE ACCOMPLISHMENT OF ALERT SI: IB777570085(LH FIXED TRAILING EDGE UPPER SKIN), FOUND CRACK ON LHW UPPER WING SKIN AT #5 FASTENER HOLE.SDR CALA2024040400976Access Panel · missingPDA 1 PANEL 196CR (GROUND AIR CONDITIONING PANEL) DELAMINATED AND 12X37 AREA BROKE OFF. REF IPC 53-96-51 ITEM 370. REF TO LOGPAGE 7519283.SDR CALA2024040200918Modulating Valve · inoperativeBLEED LOSS WING L EICAS MSG LOTS OF HISTORY DUE TO L ENG BLEED TRIPPING OFF. LOCKING LOG BLEED FAMV L STATUS MSG. MX MESSAGE 36-10180. UPDATED WITH PICS ADDED ORDER TWO OF OF THESE SEAL FOR FAMV R &;R 801A50-0006A. RECCOMED REPLACING L FAMV. COMPLETED HIGH SDR CALA2024041001027Wheel · fireFLAMES EXTIGUISHED AFT LDG GEAR BY EDDF FIRE BRIGADE. LOG FOR AFFECTED BRAKES (1,2,7,12) REMAINING WHEELS COOLED DOWN WITH AIRCOOLER. BRAKE 1 SMALL BRAKEFIRE, COOLED DOWN PER FIREGUARD WITH AIR AND WATERSPRAY HIGH ENERGY STOP INSPECTION PERFORMED PER AMM 05-5SDR CALA2024040200921Coupling · leakingALL LAVS LEAKING BROWN SEWAGE FROM SINKS.BIOHAZ ARD. FOUND BLOCKAGE AT WASTE LINE ELBOW INFRONT OF FWD DRAIN MAST. INNER COATING OF ELBOW IS DAMAGED AND CAUSING BLOCKAGE. FOR REF SEE IPC 38-31-53-81A ITEM 220 ELBOW HOSE M&E 99-3831-3-0025 MFG P/N BOE2013-0458SDR CALA2024040800999Sensor · inoperativeLEFT HAND IDG LEVEL , QUANITY, BLANK ON MAINTENANCE PAGE SERVICED IDG, FOUND MFD DISPLAY BLANK. MUST REPAIR THE INDICATION PROBLEM WITHIN 250 FLIGHT HOURS. AMM 12-13-03600-802, ACCOMPLISHED INTERIM REPAIR FOR LEFT HAND TOMC-APPROVAL FROM SC1ELBYC COMMENT IDGSDR CALA2024032200831Skin · damagedRIGHT SIDE FWD ACFT DAMAGE ABOVE EXTERNAL POWER DOOR. MORE PHOTO ATTACHED DAMAGE 3.75 IN WIDE BY 1.50 . .50 IN DEEP STARTED TO REMOVED FASTENERS AND DAMAGE CUTOUT REF. SRM REMOVED FASTENER AND CUT OUT DAMAGE AREA, REF: SRM 53-00-01-2R 53-10-01 RFPAIR4 -4 ADDSDR CALA2024031900791Rivet · missingLEFT WING #4 FLAP AFT FAIRING OUTBOARD TOTAL 20EA RIVETS MISSING OR LOOSE. RIGHT WING #5 FLAP AFT FAIRING OUTBOARD TOTAL 20EA RIVETS MISSING OR LOOSE. INBOARD TOTAL 10EA RIVETS MISSING OR LOOSE. ABOVE FAIRING POSITION IS LEFT WING #3 FLAP AFT FAIRING. ACPD PERSDR CALA2024031400732Hose · damagedHYD PUMP PRI C2 EICAS STATUS LOW CENTER SYSTEM HYDRAULIC PRIMARY PUMP #2 PRESSURE WHEN COMMAN DED ON, OR CENTER PRIMARY PUMP #2 OVERHEAT. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2910560 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: HSDR CALA2024031100682Skin · damagedDAMAGE TO AIRCRAFT FUSELAGE REPORTED BY A/C CLEANERS: LOCATION IS LEFT AFT AT APPROX STA 2000,JUST BEFORE AFT OUTFLOW VLV. TOTAL AREA OF DAMAGE MEASURES 18"X18". PUNCTURE IS 2"X1.5".GOUGE IS APPROX 9"X3".DENT IS MOST AFT (BARELY VISIBLE) AT 2"X1.5". STARTED SDR CALA2024030400626Idg · trippedELEC GEN DRIVE L CAUTION ON TO ROLL AGAIN ON TAXI IN PICTURE ADDED OF NUMBER 1 ENGINE IDG OIL LEVEL FOUND MX-MSG 24-31551, L-IDG SHOWS LOW OIL PRESSURE, SERVICED IDG TO NORMAL LEVEL. INSPECTED FOR LEAK, NO FINDINGS. INSPECTED IDG FILTER, NO METAL PARTICLES ANDSDR CALA2024012500226Battery · overheatedCABIN THERMAL CONTAINMENT BAG USED. REPLACED TCB. SEATS 58F/G HEAT DAMAGE FROM DEVICE - EXTRA BATTERIES IN PAX BACKPACK. DAMAGE TO SEAT CUSHION, SEATBELT AND BUMPER TRIM. THERMAL BAG WAS USED. REMOVED AND REPLACED SEAT CUSHIONS AND SEATBELTS AT 58G AND 58F.SDR CALA2024012400223Fan · failedCARGO VENT FAN BULK EICAS STATUS FAILURE OF BULK CARGO VENTILATION FAN. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2111013 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CRUISE NARRATIVE: ECSMC (LEFT) UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CSDR CALA2023122903754Hose · leakingHYD QTY LOW C EICAS ADVISORY CENTER HYDRAULIC SYSTEM LOW RESERVOIR QUANTITY. QTY < .40 FIM TASK REF : 29-11 TASK 894 CMC MSG# 2910150 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: HYDRAULIC INTERFACE MOD ULE (HYDIM)(CL) SEE ATTACHED PHOTOS OF HOSDR 2023FA0000770Link · brokenAIRCRAFT 9V-SWH WAS UNDERGOING “C06” CHECK IN HANGAR ENVIRONMENT. A LANDING GEAR ALTERNATE EXTENSION TEST WAS SCHEDULED. WHILE ON JACKS, THE INITIAL GEAR LEVER UP RETRACTION TEST
WAS COMPLETED SUCCESSFULLY. HOWEVER, WHILE STILL PERFORMING THE LANDING GEAR ALSDR CALA2023111003332Battery Pack · weakDR4 RH EMERGENCY LIGHT BATTERY (M33401)FOUND TO BE WEAK DURING TEST(P/N:D717-01-100 AND S/N:442042) DR4 RH EMERGENCY BATTERY(M33401)REPLACED AS PER AMM33-51-06-960- 802 REV 99 DATED 05 SEP 2023.INSTALLATION TEST CARRIED OUT AND F OUND WORKING SATISFACTORY. (ONSDR CALA2023110303280Fuse · inoperativeROWS 46DEFG THROUGH 51DEFG FLOOR PROXIMITY EMERGENCY LIGHTS INOP REQUEST TO PLACE AFFECTED PROXIMITY LIGHT(S) ON DEFERRAL MEL 3351A MAINT IS TRYING TO CLEAR THIS ITEM. REPLACED FUSE, OPS CHECK NORMAL AT THIS TIME REF AMM 33-51-06 & WDM 33-51-11SDR CALA2023100602983Light · crackedSEAT 22G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY FOUND CRACK. SEAT 22G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY REPLACED AND OPER ATIONAL TEST PERFORMED AS PER AMM33-51-05, FOUND SATISFACTORY.SDR CALA2023100602981Light · crackedSEAT 53G AND 54G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY FOUND CRACK. SEAT 53G AND 54G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY REPLACED AS PER CMM25-21-53 REV 1 INSTALLATION TEST PERFOR MED AND FOUND SATISFACTORY.SDR CALA2023100602979Charger · damagedDOOR 1 RIGHT (M33094) EPSU CHARGER ASSEMBLY TEST BUTTON FOUND MISSING. DOOR 1 RIGHT EPSU CHARGER ASSEMBLY REPLACED AS PER AMM33-51-06-9 REV 98 DATED 05 MAY 2023. INSTALLATION TEST CARRIED OUT AS PER AMM33-51-06-960-803 REV 99 DATED 05 SEP 2023 FOUND WORKING SASDR CALA2023100602977Housing · crackedM7 GALLEY RH FWD PROXIMITY LIGHT ASSY FOUND HOUSING CRACKED. M7 GALLEY RH FLOOR PROXIMITY LIGHT ASSY REPLACED AND OPERATIONAL CHECK FOUND SATISFACTORY AS PER AMM33-51-05. WORK ACCOMPLISHED BY V943554SDR CALA2023100602975Charger · damagedDOOR 4 LEFT(M33406)EPSU CHARGER ASSEMBLY TEST BUTTON FOUND MISSING. EPSU CHARGER ASSEMBLY REPLACED AS PER AMM33-51-06-960-803 REV 98 INSTALLATION TEST CARRIED OUT AS PER AMM33-51-06-960-803 REV 99 DATED 05 SEP 2023, FOUND WORKING SATISFACTORY.SDR CALA2023100602985Lamp · inoperativeFOUND FOLLOWING CABIN SEATS PEEPS LAMP (1 OFF EACH)BLOWN AT 34D, 42D, 41G, 40G, 38G, 32G, 22G, 46G, 48G, 49G, 50G, 53G, 54G, 56G, 58G, 57D, 54D, 49D AND 47D THE FOLLOWING SEATS PEEPLS LIGHT LAMP REPLACED AND OPERATION TES ALL LIGHTS WORKING GOOD. T CARRIED OUTSDR CALA2023091802811Battery · noneEMERGENCY FLASH LIGHT BATTERIES FOUND WITH SERVICE LIFE EXPIRING. EMERGENCY FLASHLIGHT BATTERIES 14 EACH REPLACED IAW AMM 25-60-07 BY MECH L3885. NRC 38593834
Back to Boeing 777-300ER