SDR AALA20100907TUL13Cusp Web · damagedDAMAGE ON CUSP SHEET STATION 598 TO 617. INSTALLED SERVICEABLE CUSP SHEET PER AARD 53-20-00-16.SDR AALA20100907TUL12Longeron Splice · corrodedCORROSION ON LONGERON SPLICE FORWARD END STATION 1293 LONGERON 30. INSTALLED NEW SPLICE PER SRM 53-14-03.SDR AALA20100907TUL09Cusp Web · corrodedCORROSION ON CUSP RIGHT STATION 389. REMOVED CORROSION AND INSTALLED DOUBLER REPAIR PER AARD 53-20-00-16.SDR AALA20101207TUL11Battery Pack · dischargedFLOOR PROXIMITY EMERGENCY PATH LIGHTS FROM ROWS 3 TO 19 INOPERATIVE. REPLACED BATTERY PACK FOR FLOOR PROXIMITY EMERGENCY PATH LIGHTS AT ROWS 3 TO 19. OPS CHECK NORMAL.SDR AALA20100906LGA01Battery Pack · dischargedEMERGENCY LIGHTS AT RIGHT AND LEFT NUMBER DOORS INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS AT RIGHT AND LEFT NUMBER 1 DOORS. OPS CHECK NORMAL.SDR AALA20100906EWR01Computer · faultedEWR - CAPTAIN REPORTED SLAT DISAGREE LIGHT REMAINING ILLUMINATED AFTER SLAT RETRACTION. EMERGENCY DECLARED RETURNED EWR LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED DIRECT FLIGHT GUIDANCE COMPUTER NUMBER 2 THAT WAS AT FAULT. SYSTEM GROUSDR AALA20100903TUL02Skin · damagedDENT OVER SHEAR TIE AT STATION 1309, BETWEEN LONGERON 23 AND LONGERON 24, LEFT SIDE OF FUSELAGE. INSTALLED INTERNAL DOUBLER AS PER SRM 53-04-00 AND EA MD80-53-012815 AND THE SHEAR TIE REPAIR WAS DONE AS PER SRM 53-03 FIGURE 45 AND EA MD80-53-012815.SDR AALA20100902TUL02Cusp Web · damagedCORROSION ON CUSP SHEET STATIONS 165 TO 168. INSTALLED DOUBLER AND SERVICEABLE CUSP SHEET PER AARD 53-20-00-16, AARD 53-20-00-14, AND EA 80-53-012686 STATION 160-200 RIGHT SIDE.SDR AALA20100831TUL10Casting · corrodedCORROSION ON CASTING ABOVE ACCUMULATOR OUTBOARD OF HYDRAULIC LINE. REPLACED CASTING PER SRM 51-01-00.SDR AALA20100831TUL09Cusp Web · corrodedCORROSION ON LEFT CUSP AT STATION 470 OUT OF LIMITS. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.SDR AALA20100831TUL08Frame · damagedSIXTH HOLE UP FROM SUBFLOOR IN FRAME AT STATION 160 APPROXIMATELY 8 INCHES ABOVE FLOOR LINE IS DOUBLE DRILLED FORWARD SERVICE DOOR AREA. INSTALLED DOUBLER AND STRAP DOUBLER PER EA MD80-53-012704.SDR AALA20100831TUL07Seat Track · corrodedSEAT TRACK NUMBER 4 BLENDED OUT OF LIMITS AT STATION 757 TO 761. REMOVED DAMAGED MATERIAL AND INSTALLED REPAIR PLUG PER SRM 53-05-00 FIGURE 4A AND AARD 53-20-00-10.SDR AALA20100831TUL06Membrane · corrodedSUBFLOOR CORRODED AROUND POTABLE WATER LINE HOLE APPROXIMATE STATION 151 RIGHT SIDE. INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20100831TUL05Seat Track · corrodedSEAT TRACK NUMBER 4 BLENDED OUT OF LIMITS AT STATION 725 TO 730. REMOVED DAMAGED MATERIAL AND INSTALLED REPAIR PLUG PER SRM 53-05-00 FIGURE 4A AND AARD 53-20-00-10.SDR AALA20100831TUL04Skate Angle · crackedSKATE ANGLE DOUBLER IS CRACKED LOWER LEFT SIDE OF VERTICAL STAB AT CANT 1403. INSTALLED NEW SKATE ANGLE DOUBLER AT CANT 1403 LEFT SIDE PER AARD53-10-00-2.SDR AALA20100830TUL08Skin · damagedDOUBLER INSTALLED AT STATION 576 LONGERON 26 RIGHT DOES NOT CONFORM TO SRM REPAIRS IN CHAPTER 53-04-00 FIGURE 38 OR FIGURE 12. INSTALLED INTERNAL DOUBLER AND FLUSH DOUBLER PER EA MD 80-53-012708 DATED 8/20/2010, SRM 53-04-00 FIGURE 12C SHEET 3 AND BOEING DRAWISDR Y2PA2010083000020Power Supply · inoperativeWHILE PERFORMING A SERVICE CHECK, THE OVERWING EMERGENCY EXIT LIGHTS (ON FUSELAGE) WERE FOUND INOPERATIVE DUE TO A NON FUNCTIONING RECHARGEABLE BATTERY POWER SUPPLY. BATTERY WAS FOUND TO BE CHARGED BUT UNIT NOT PROVIDING POWER TO LIGHTS. UNIT TO BE REPLACED SDR AALA20100830TUL11Pan · crackedWINDOW PAN CRACKED RIGHT STATION 1022 UPPER AFT CORNER. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR AALA20100830TUL10Pan · crackedWINDOW PAN CRACKED RIGHT STATION 946 UPPER FORWARD CORNER. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR WX0A070593Fire Loop · failedFLIGHT PERSONNEL REPORTED UPON APPROACH CARGO FIRE (MID) ILLUMINATED. PER QRH 26.4 FIRED FIRE BOTTLES. AIRCRAFT FERRIED FROM ICT TO LAS. MAINTENANCE PERSONNEL TROUBLESHOOT AND TESTED, HAD INTERMITTENT FAILURE OF DETECTOR LOOP "B". REMOVED AND REPLACED THE SDR AALA20100829TUL02Frame · crackedAFT ACCESSORY FRAME CRACKED AT STATION 1418 LONGERON 2 LEFT. INSTALLED DOUBLER REPAIRS ON FORWARD AND AFT SIDE OF FRAME 1418 AT LONGERON 2 LEFT PER AARD 53-10-00-15 AND SRM 53-03-00.SDR AALA20100829TUL01Cusp Web · corrodedCORROSION ON SUBFLOOR AT STATION 200 BELOW FORWARD END OF FIBERGLASS SUPPORT NUMBER 6 SEAT TRACK. INSTALLED CUSP DOUBLER FROM STATION 200 TO STATION 218 PER AARD53-20-00-16.SDR AALA20100830LGA02Battery Pack · dischargedFOUND CEILING EMERGENCY LIGHTS IN ROWS 20 TO 25 INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT POSITION B5-106. OPS CHECKED NORMAL.SDR AALA20100830LGA01Battery Pack · dischargedFORWARD CEILING EMERGENCY LIGHTS IN FORWARD CABIN INOPERATIVE. REMOVED AND REPLACED BATTERY PACK IN FORWARD CEILING. OPS CHECKED NORMAL.SDR AALA20100829TUL07Cusp Web · corrodedLEFT CUSP SHEET STATION 1098 TO STATION 1174 HAS CORROSION. INSTALLED NEW LEFT CUSP SHEET STATION 1098 TO STATION 1174 PER AARD 53-20-00-16.SDR AALA20100829TUL06Seat Track · corrodedCORROSION REMOVAL AT SEAT TRACK NUMBER 2 IS OUT OF LIMITS. INSTALLED NEW SECTION OF NUMBER 2 SEAT TRACK STATION 1089 TO 1184 PER AARD 53-05-00 FIGURE 4F.SDR AALA20100829TUL05Frame · crackedAFT ACCESSORY STATION 1418 FRAME CRACKED LONGERON 2 RIGHT. INSTALLED REPAIR DOUBLER ON FORWARD SIDE OF FRAME STATION 1418 LONGERON 2 RIGHT PER SRM 53-03-00.SDR AALA20100829TUL04Longeron · crackedAFT ACCESSORY LONGERON 2 RIGHT CRACKED AFT OF STA 1418. INSTALLED SPLICE REPAIR AT STATION 1418 LONGERON 2 RIGHT PER AARD 53-30-00-2.SDR AALA20100829TUL03Longeron · crackedAFT ACCESSORY LONGERON 2 LEFT CRACKED AFT OF STATION 1418. INSTALLED LONGERON REPAIR SPLICE AT STATION 1418 LONGERON 2 LEFT PER ARRD 53-30-00-2.SDR AALA20100828TUL02Cusp Web · corrodedCORROSION OUT OF LIMITS AT STATIONS 680 TO 690 ON RIGHT CUSP. INSTALLED DOUBLER ON RIGHT CUSP PER AARD 53-20-00-16.SDR AALA20100828TUL01Cusp Web · damagedRIGHT CUSP STATION 683 HAS TOOLING MARKS. INSTALLED DOUBLER PER EA MD8053-012663.SDR AALA20100827TUL03Strap · gougedFRAME STRAP AT LEFT CUSP STATION 1136 GOUGED OUT OF LIMITS. REPLACED STRAP PER SRM 51-30-05.SDR AALA20100827TUL02Strap · gougedFRAME STRAP AT LEFT CUSP STATION 1127 FOUND GOUGED OUT OF LIMITS. REPLACED STRAP PER SRM 51-30-05.SDR AALA20100827TUL01Angle · crackedTAIL - UPPER EDGE OF ANGLE CRACKED INSIDE RIGHT HORIZONTAL STAB AT SIDE ROLLER AREA. REMOVED AND REPLACED DAMAGED RIGHT HORIZONTAL STAB ANGLE WITH NEW ONE IAW 55-10-00-4. ALSO CHANGED ROLLER BRACKET IAW AARD 55-10-00-5.SDR AALA20100824TUL05Cargo Track · corrodedFORWARD CARGO RIGHT TIE DOWN TRACK HAS CORROSION AROUND FLOOR AND SIDEWALL PANEL ATTACH HOLES AFT OF DOOR OPENING. TIE DOWN TRACK BLENDED BEYOND MANUAL LIMITS AT STATIONS 434 TO 446 PER SRM 53-01-00. INSTALLED REPAIR STRAP PER AARD 53-20-00-13.SDR AALA20100824TUL04Cusp Web · corrodedCORROSION BEYOND LIMIT RIGHT CUSP AT STATION 488 TO 489. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.SDR AALA20100823TUL06Cusp Web · corrodedINBOARD OF NUMBER 5 SEAT TRACK AT STATION 200 CORROSION ON SUBFLOOR. CUT OUT DAMAGED AREA OF CUSP AND INSTALLED NEW CUSP DOUBLER PER AARD53-20-00-16.SDR AALA20100824LGA03Battery Pack · dischargedCEILING EGRESS LIGHTS INOP ROWS 11 THROUGH 16. REMOVED AND REPLACED BATTERY PACK AT ROW 20 DEF.SDR AALA20100824LGA02Battery Pack · dischargedTAIL CONE CEILING EGRESS LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK AT ROW 20 DEF.SDR AALA20100824LGA01Battery Pack · dischargedCEILING EGRESS LIGHTS INOPERATIVE AT ROWS 18 THROUGH 21. REMOVED AND REPLACED BATTERY PACK AT ROW 20 DEF.SDR AALA20100823LGA02Battery Pack · dischargedEMERGENCY EXIT LIGHTS ARE INOPERATIVE FROM ROWS 7 TO 13. REPLACED BATTERY PACK.SDR AALA20100823TUL02Cusp Web · corrodedCORROSION FOUND OUT OF LIMITS LEFT CUSP AT STATIONS 454 TO 462 OUTBOARD LIGHTENING HOLES. CUT OUT DAMAGE AND INSTALLED DOUBLER ON CUSP PER AARD53-20-00-16.SDR AALA20100821DFW02Controller · failedDFW - ON CLIMBOUT AUTO PRESSURIZATION CONTROLLER NUMBER 2 FAILED. NUMBER 1 CONTROLLER ON PLACARD. FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED THE NUMBER 1 CONTROLLER DUE TO VALVE MOTOR FAULT NOT CLEARING. SYSTEM GRSDR AALA20100820TUL09Rib · crackedNUMBER 5 SLAT 2ND FROM OUTBOARD END SLAT RIB IS CRACKED. REPLACED DAMAGED NUMBER 14 2ND FROM OUTBOARD RIB PER IAW ESO 89117 27-80-1.SDR AALA20100820TUL08Rib · crackedNUMBER 5 SLAT OUTBOARD SLAT RIB IS CRACKED. REPLACED NUMBER 15 OUTBOARD RIGHT RIB PER IAW ESO 80117 27-80-01.SDR AALA20100819TUL08Mount · corrodedSTATION 207, 12 INCHES OF NUMBER 4 SEAT TRACK MOUNT IS CORRODED. INSTALLED NEW MOUNT SRM 51-01-00.SDR AALA20100818DFW04Reservoir · leakingDFW - CAPTAIN REPORTED THAT THE AIRCRAFT HAD LOST THE ENTIRE RIGHT HYDRAULIC SYSTEM. PRESSURE DROPPED TO ZERO WITH A SPIKE IN HYDRAULIC QUANTITY. EMERGENCY DECLARED LANDED DFW WITHOUT INCIDENT. MAIN LANDING GEAR DOOR SKIDS DAMAGED DUE TO NO RIGHT HYDRAULICSDR AALA20100816DFW04Clamp · looseDFW - CREW REPORTED TAIL COMPARTMENT HI LIGHT ILLUMINATED ON CLIMBOUT. EMERGENCY DECLARED RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND RIGHT AIR CONTROL MACHINE OUTFLOW MANIFOLD CLAMP LOOSE. TIGHTENED CLAMP NO DISCREPANCIES NOTSDR AALA20100816TUL06Shear Tie · crackedAFT ACCESSORY SHEAR TIE CRACKED. REMOVED AND REPLACED SHEAR TIE PER SRM 51-30-05.SDR AALA20100813LGA01Battery Pack · dischargedEMERGENCY LIGHTING AT AFT SERVICE DOOR INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT AFT SERVICE DOOR.
Back to Boeing DC-9-83