SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0480031Lanyard · disconnectedSEA PREFLIGHT CHECK, FOUND AFT SERVICE DOOR L2 EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR ASAA0480044Skin · dentedOKC - DURING 15K CHECK, FOUND FUSELAGE SKIN IS DENTED AT FS 1398. INSTALLED DOUBLER PER SRM 53-04. (M)SDR ASAA0480049Flange · crackedOKC - DURING 15K CHECK, FOUND LEFT AFT LAVATORY WASTE CHUTE MOUNTING FLANGE CRACKED. STOP-DRILLED CRACKS AND INSTALLED DOUBLER PER EA 2540-01116. (M)SDR ASAA0480048Splice · corrodedOKC - DURING 15K CHECK, FOUND STRUCTURAL SPLICE IS CORRODED AT FS 1212 IN AFT CARGO BAY AREA. REMOVED CORROSION AND TREATED PER EA 5310-02309. (M)SDR ASAA0480047Floorboard · damagedOKC - DURING 15K CHECK, FOUND CABIN FLOOR PANEL HAS DAMAGED CORE AT FS 655. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480052Skin · corrodedOKC - DURING 15K CHECK, FOUND FUSELAGE SKIN CORRODED AT AFT LAVATORY SERVICE PANEL. REMOVED CORROSION AND INSTALLED REPAIR STRAP PER EA 5320-01635. (M)SDR ASAA0480051Longeron · corrodedOKC - DURING 15K CHECK, FOUND LONGERON 23R CORRODED AT FS 769-788. REMOVED CORROSION AND INSTALLED REPAIR U-CHANNEL PER SRM 53-02. (M)SDR ASAA0480050Trunnion · gougedOKC - DURING 15K CHECK, FOUND LEFT MLG FORWARD TRUNNION FITTING IS GOUGED ON LOWER SIDE. REMOVED DAMAGE, PERFORMED HFEC, FLAP PEEN, AND TREATED AND PRIMED AREA PER EA5740-01373. (M)SDR ASAA0480045Floorboard · delaminatedOKC - DURING 15K CHECK, FOUND CABIN FLOOR PANEL IS DELAMINATED AT FS 886-927. REPLACED FLOOR PANEL PER SRM 51-01. (M)SDR ASAA0480046Floorboard · puncturedOKC - DURING 15K CHECK, FOUND CABIN FLOOR PANEL IS PUNCTURED AT FS 1041. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR GTIA040119Floor Panel · delaminatedFTW - FOUND LEFT FLOOR PANEL STATION 200-256 DELAMINATED AND TWO INSERTS MISSING. FABRICATED NEW PANEL. (M)SDR GTIA040044Smoke Detector · malfunctionedLAS - FLT 1108 - RETURN TO LAS, SMOKE IN CABIN AND LAVATORY ALARMS WENT OFF. INSPECTED CARGO BINS, TAIL CONE AREA AND CABIN, NO DEFECTS NOTED. RAN ENGINES NO DEFECTS NOTED. OPERATED PACKS NO DEFECTS NOTED, INSPECTED COALESCER SOCKS. NO DEFECTS NOTED. (M)SDR GTIA040046Switch · malfunctionedDTW - FLT 9815 - AFTER TAKEOFF LAS ABOUT 30 SECONDS A/C GOT VERY HOT IN THE CABIN SOME HAZE, TURN RIGHT PACK OFF A/C COOLED OFF NO HAZE, RIGHT PACK NEEDLE FLUCTUATED FROM 10-2 O'CLOCK POS BEFORE TURNING OFF SUPPLY TEMP ONLY INDICATED 140. TESTED CABIN TEMP COSDR AALA20040134Light · inoperativeRDU EMERGENCY PATH LIGHT AT ROW 15D INOPERATIVE. REPLACED EMERGENCY PATH LIGHT ASSEMBLY FOR ROW 15D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0480036Longeron · corrodedOKC - DURING INSPECTION, FOUND MID CARGO PIT STATION 598-617 LONGERON 30 CORRODED AROUND FASTENERS. REPAIRED BY REMOVING CORROSION, SPOT FACED AREA, IAW EA 5310-02311 AND AAR EA 10234. (M)SDR ASAA0480035Floor Support · corrodedOKC - DURING INSPECTION, FOUND AFT CARGO FLOOR SUPPORT ANGLE EXFOLIATED STATION 1212 BETWEEN 28R AND 27R. REPAIRED BY REMOVING DAMAGED SUPPORT AND INSTALLED NEW SUPPORT IAW MD80 SRM 51-30-4. (M)SDR ASAA0480039Frame · corrodedOKC - DURING INSPECTION, FOUND CORROSION ON AFT SIDE OF FRAME AT STATION 1271 AND LONGERON 30. REPAIRED BY REMOVING DAMAGE. FABRICATED AND INSTALLED REPAIR FILLERS AND DOUBLERS IAW MD80 SRM 53-03. (M)SDR ASAA0480038Seat Track · corrodedOKC - DURING INSPECTION, FOUND MAIN CABIN STATION 628 X= -44 CORROSION ON SEAT TRACK. REPAIRED BY REMOVING DAMAGED SECTION. FABRICATED AND INSTALLED REPLACEMENT SEAT TRACK AND TWO SPLICES IAW MD80 SRM 53-05. (M)SDR ASAA0480034Floor Support · corrodedDURING INSPECTION, FOUND AFT CARGO FLOOR SUPPORT STATION 1080 HAS EXFOLIATION ON UNDERSIDE AT NUTPLATES ABOVE LONGERON 30 TO 28L. REPAIRED BY REMOVING EXFOLIATED PART AND INSTALLED NEW PART PER MD80 SRM 51-10-4. (M)SDR ASAA0480033Floor Panel · crackedOKC - DURING INSPECTION, FOUND CABIN FLOOR PANEL FOR STATION 693-769 BETWEEN RBL 44 AND RBL 54 HAT CHANNEL ON UNDERSIDE IS CRACKED. REPAIRED IAW MD80 SRM 51-70-5. (M)SDR ASAA0480032Skin · crackedDURING INSPECTION, FOUND SKIN CRACKED AT FORWARD HINGE RIGHT AFT NOSE GEAR DOOR EMINATING FROM RIVET HOLE FORWARD OF FORWARD HINGE CUTOUT. REPAIRED IAW SRM 51-10-2, 51-10-4 AND 51-30-2. (M)SDR ASAA0480042Beam · corrodedDURING INSPECTION, FOUND AFT PIT LOWER FLANGE ON BEAM AT CARGO DOOR IS CORRODED AT STATION 1182. REPAIRED BY REMOVED DAMAGED BEAM, INSTALLED NEW BEAM IAW MD80 SRM 51-30-2, 51-30-5, 51-10-3. (M)SDR ASAA0480037Floorboard · delaminatedDURING INSPECTION FOUND FLOORBOARD STATION 769 TO 826, LBL 22-44 HAS SEVERAL AREAS OF EDGE DAMAGE. REPAIRED BY FABRICATED REPLACEMENT FLOORBOARD IAW MD80 SRM 53-05. (M)SDR ASAA0480040Skin · tool damageOKC - DURING INSPECTION, FOUND RIVET SET MARK AT STATION 398, LONGERON 30, ON SKIN. REPAIRED BY COLD WORKED AREA, COMPLIED WITH HFEC, FABRICATED AND INSTALLED REPAIR DOUBLER IAW MD80 SRM 53-04. (M)SDR ASAA0480041Shear Tie · corrodedOKC - DURING INSPECTION, FOUND AFT PIT STATION 1193 BETWEEN STRINGER 20 AND 29L SHEAR TIE CORRODED. REPAIRED BY REMOVED DAMAGE, FABRICATED REPAIR SHEAR TIE AND SPLICE IAW MD80 SRM 53-03. (M)SDR AALA20040145Slide · displacedAUS L2 AFT SERVICE DOOR SLIDE FOUND BELOW GREEN BAND ON A CHECK. REPLACED L2 AFT SERVICE DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR GTIA040034Odor · detectedDTW - STRONG ODOR OF KEROSENE EXHAUST THROUGH OUT CABIN AND COCKPIT, ALL FLIGHT PHASES. CLEANED GROUND AIR CONDITIONING SUPPLY DUCT. AFTER CLEANING NOTED NO ODOR FROM RT PACK. (M)SDR AALA20040124Controller · arcedDFW INFLIGHT T802/25 FIRST OFFICERS WINDOW HEAT STARTED ARCHING ACROSS WINDOW AND WINDOW SHATTERED. RETURNED TO STATION. LANDED WITHOUT INCIDENT. REPLACED FIRST OFFICERS WINDOW AND CONTROLLER. SYSTEM GROUND CHECKED NORMAL OPERATION.--CLOSED--SDR ASAA0580041Access Panel · corrodedOKC - HV-CHECK, LEFT WING FUEL PANELS 1363 AND 1367 ARE CORRODED ON LANDINGS. REPLACED PANELS, AT XRS 267-295 AND XRS 295-353 RESPECTIVELY. (M)SDR ASAA0580040Access Panel · chafedOKC - HV-CHECK, LEFT WING FUEL PANELS 1307, 13333, AND 1379 ARE WORN AND CHAFED AT EDGE. REPLACED PANELS AT XFS 70-196, XCW58-70, AND XRS 445-447 RESECTIVELY. (M)SDR ASAA0580043Access Panel · corrodedOKC - HV-CHECK, RIGHT WING FUEL PANEL AT HEAT BLANKET IS CORRODED. REPLACED PANEL. (M)SDR ASAA0580042Access Panel · corrodedOKC - HV-CHECK, RIGHT WING FUEL PANELS 1436 AND 1464 ARE CORRODED. REPLACED PANELS, AT XFS 58-70 AND XRS 324-353 RESPECTIVELY. (M)SDR ASAA0580021Tab · damagedOKC - HV-CHECK, LEFT ELEVATOR ANTI-FLOAT TAB MISSING COMPOUND. REPLACED MISSING COMPOUND. (M)SDR ASAA0580027Skin · dentedOKC - DURING HV-CHECK, AFT CARGO BAY DOOR DENTED JUST BELOW TOP EDGE. RECONTOURED DOOR SKIN AND INSTALLED REPAIR DOUBLER. (M)SDR ASAA0580036Floorboard · damagedOKC - DURING C-CHECK, FOUND CABIN FLOORBOARD PANEL HAS PULLED FIBERGLASS STRANDS. APPLIED FIBERGLASS OVERLAY. (M)SDR ASAA0580028Vane · chafedOKC - HV-CHECK, LEFT OUTBOARD FLAP INBOARD VANE CHAFED. REMOVED DAMAGE. INSTALLED REPAIR FILLER AND DOUBLER. (M)SDR ASAA0580023Frame · gougedOKC - HV-CHECK, RIGHT TAIL COMPARTMENT FRAME IS GOUGED. REMOVED DAMAGE. INSTALLED REPAIR PLATE AND ANGLE. (M)SDR ASAA0580017Longeron · corrodedOKC - HV-CHECK, AFT CARGO BAY LONGERON 29R CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR ANGLE. (M)SDR ASAA0580014Structure · gougedOKC - HV-CHECK, AFT CARGO BAY DOOR LOWER AFT INTERIOR GOUGED. REMOVED DAMAGED SECTIONS. REPAIRED SECTIONS PER EA 5210-01168. (M)SDR ASAA0580012Cusp Web · crackedOKC - HV-CHECK, MID CARGO BAY CUSP WEB/MEMBRANE CRACKED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER. (M)SDR ASAA0580022Vane · chafedOKC - HV-CHECK, LEFT OUTBOARD FLAP VANE CHAFED INBOARD EDGE. REMOVED DAMAGE. INSTALLED FILLER AND REPAIR DOUBLER. (M)SDR ASAA0580015Bearing · wornOKC - HV-CHECK, RUDDER TORQUE TUBE BEARING IS WORN. REPLACED TORQUE TUBE ASSEMBLY. (M)SDR ASAA0580020Skin · gougedOKC - HV-CHECK, LEFT INBOARD FLAP LOWER SURFACE GOUGED. REMOVED DAMAGE. INSTALLED REPAIR DOUBLER. (M)SDR ASAA0580034Skin · dentedOKC - DURING C-CHECK, FOUND FUSELAGE SKIN DENTED. RECONTOURED SKIN WITH REPAIR DOUBLER. (M)SDR ASAA0580035Skin · dentedOKC - DURING C-CHECK, FUSELAGE SKIN DENTED. RECONTOURED SKIN WITH REPAIR DOUBLER. (M)SDR ASAA0580033Floor Panel · puncturedOKC - HV-CHECK, COCKPIT FLOOR PANEL PUNCTURED. REMOVED DAMAGED AREA. INSTALLED REPAIR DOUBLER. (M)SDR ASAA0580013Structure · corrodedOKC - HV-CHECK, AFT CARGO BAY DOOR CORRODED AT SEVERAL SLEEVE AND EXPANDER POINTS. REMOVED DAMAGED SECTIONS. INSTALLED REPAIR DOUBLERS. (M)SDR ASAA0580037Floorboard · damagedOKC - DURING C-CHECK, CABIN FLOORBOARD HAS PULLED FIBERGLASS STRANDS. APPLIED FIBERGLASS OVERLAY. (M)SDR ASAA050027Skin · dentedOKC - HV-CHECK, AFT CARGO BAY DOOR DENTED JUST BELOW TOP EDGE. RECONTOURED DOOR SKIN AND INSTALLED REPAIR DOUBLER. (M)SDR ASAA0580018Tab · dentedOKC - HV-CHECK, RIGHT ELEVATOR GEAR TAB UPPER SURFACE IS DENTED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER. (M)
Back to Boeing DC-9-83