Boeing DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20150914012Cusp Web · corrodedCORROSION AT STATION 1155 - 1165, RT CUSP. REMOVED DAMAGE, INSTALLED DOUBLER REPAIR IAW AARD 53-20-00-16.SDR AALA20150917008Unknown · faultyAIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB CREW NOTED FUEL MIGRATING INTO THE CTR TANK & WOULD NOT TRANSFER OUT. ACCOMPANIED BY A CTR LOW PRESS LOW LIGHT INDICATION. R & R CTR TANK, FWD & AFT UFIS. PERFORMED OPSDR AALA20150909022Pump · faultyAIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB CTR FUEL PRESS LOW LIGHT ILLUMINATED WITH 7000 LBS IN THE CTR TANK. R & R CTR FWD BOOST PUMP.SDR AALA20150909014Indication Sys · malfunctionedDURING CLIMB CREW NOTED FUEL MIGRATING INTO THE CTR TANK & WOULD NOT TRANSFER OUT. ACCOMPANIED BY A CTR LOW PRESSURE LOW LIGHT INDICATION. AIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL. R & R CTR TANK FWD & AFT UFIS. PERFORMED OPERATIONAL CHECK IAW SDR AALA20150909016Shear Tie · crackedSHEAR TIE CRACKED AT STATION 1446 BELOW L17R. STOP DRILLED CRACK & INSTALLED REPAIR ANGLE IAW AARD 53-10-00-20.SDR WX0A2015090972851Light · inoperativeAFT BETWEEN LAVATORY, EMER LIGHT DOESN`T WORK. AFT BATTERY PACKS RT LAVATORY NOT WORKING. R & R BATTERY PACKS & LAMPS. OPERATIONS CHECK IS GOOD IAW AMM 33-53-00 401.SDR AALA20150908025Frame · crackedCANT FRAME AT FS 1463 & L19R IS CRACKED. ACCOMPLISHED DOUBLER REPAIR IAW SRM 53-01-00-001 FIG 2.SDR AALA20151005005Volute · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB, CTR TANK FUEL BOOST PUMPS NOT FEEDING FROM CTR TANK. CTR LOW PRESS LIGHT ILLUMINATED. R & R CTR AFT BOOST PUMP IAW AMM 28-20-07, DIFFERENTIAL PRESS SWITCHES S1-266 & S1267SDR AALA20151005004Housing · crackedAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB, CTR TANK FUEL BOOST PUMPS NOT FEEDING FROM CTR TANK. CTR LOW PRESS LIGHT ILLUMINATED. R & R CTR AFT BOOST PUMP IAW AMM 28-20-07, DIFFERENTIAL PRESS SWITCHES S1-266 & S1267SDR AALA20151005003Switch · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB, CTR TANK FUEL BOOST PUMPS NOT FEEDING FROM CTR TANK. CTR LOW PRESS LIGHT ILLUMINATED. R & R CTR AFT BOOST PUMP IAW AMM 28-20-07, DIFFERENTIAL PRESS SWITCHES S1-266 & S1267SDR AALA20151005002Switch · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB, CTR TANK FUEL BOOST PUMPS NOT FEEDING FROM CTR TANK. CTR LOW PRESS LIGHT ILLUMINATED. R & R CTR AFT BOOST PUMP IAW AMM 28-20-07, DIFFERENTIAL PRESS SWITCHES S1-266 & S1267SDR AALA20150914005Pump · inoperativeCENTER TANK, FUEL BOOST PUMP INOPERATIVE. R & R CTR TANK VOLUTE & REPLACED CTR TANK BOOST PUMP PICKUP LINE PACKING’S.SDR AALA20150907002Pump · faultyDURING CLIMB, CTR TANK FUEL BOOST PUMPS NOT FEEDING FROM CTR TANK. CTR LOW PRESSURE LIGHT ILLUMINATED. DIVERTED, EMERGENCY DECLARED, & LANDING UNEVENTFUL. R & R CTR AFT BOOST PUMP IAW AMM 28-20-07, DIFFERENTIAL PRESS SWITCHES S1-266 & S1267 IAW AMM 28-41-0SDR WX0A2015090972856Warning System · false activationON CLIMB OUT AT APPROX 28000FT, THE NOSE GEAR LIGHT CAME ON. IT WENT OUT AFTER A LIGHT KNOCK BELOW THE FLIGHT DECK WAS HEARD. THE HYDS WERE NORMAL FOR QTY. QRH 32.9 WAS CONSULTED, BUT NOT PERFORMED DUE TO THE LIGHT GOING OUT. REF WO 268973 NLG UNSAFE LIGHTSDR WX0A2015090972850Fairing · damagedRIGHT WING ROOT LE FAIRING HAS EROSION DAMAGE, APPROX 12"" IN LENGTH & .070"" DEEP. PERFORMED INTERIM REPAIR IAW EA 20-2015-229. INSPECTION REQUIRED AT EVERY SERVICE CHECK.SDR WX0A2015090972853Light · inoperativeEMERGENCY STBY LIGHTS INOPERATIVE AT ROW 7. RELAMPED ROW 7 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A2015090972852Light · inoperativeEMERGENCY STBY LIGHTS INOPERATIVE AT ROW 11. RELAMPED ROW 11 IAW AMM 33-53-00. OPERATIONS CHECKED NORMAL.SDR WX0A2015090972849Bulkhead · crackedCANTILEVER BULKHEAD CRACKED ABOVE TAIL SLIDE STATION 1431, BETWEEN LONGERON 54 - 56, APPEARS 2.5"" LONG. REPAIRED CANTILEVER BULKHEAD IAW SRM 53-03 FIG 38C.SDR WX0A2015091572862Tab · delaminatedLEFT ELEVATOR CONTROL TAB INBD END, PREVIOUS REPAIR DELAMINATED AT STATION XE 14.525. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS, ACCOMPLISHED HOT BOND REPAIR IAW SRM 55-04 PARA 3 FIG 2 PAGES 9 & 10. WORK ACCOMPLISHED ON WO 262843 M301 ITEM 337, WO 101201SDR WX0A2015090972848Power Supply · inoperativeRIGHT & LEFT EMER EXIT LIGHTS AT ROW 25 ARE INOPERATIVE. R & R EMER LIGHT POWER SUPPLY AT ROW 27 IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.SDR WX0A2015090672847Battery · dischargedFOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROW 30. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR WX0A2015090672846Battery · dischargedFOUND ON WAKE UP, EMER LIGHTS INOPERATIVE AT ROW 27. REPLACED BATTERIES IN POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-01.SDR AALA20150904003Fitting · crackedRIGHT WING GND SPOILER CASTING CRACKED, INBD & OTBD SIDE. INSTALLED NEW RT GND SPOILER CASTING IAW SRM 51-01-00.SDR AALA20151221002Tube · corrodedLANDING GEAR SHOP REPORTS TUBE OD HAS EXCESSIVE CORROSION AROUND PIN BORE. ADDITIONAL MACHINING WILL BRING MAX REWORK BELOW LIMITS. PART SCRAPPED & DESTROYED.SDR AALA20150908019Pump · faultyAIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB THE CTR FUEL PRESS LOW LIGHT ILLUMINATED. BOTH CTR FUEL PUMPS INOPERATIVE. R & R FWD CTR FUEL BOOST PUMP IAW AMM 28-20-07-201 & AMM 57-30-03-401. OPERATIONAL & LEAK CHSDR AALA20150903017Acm · failedAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING TAKEOFF, TEMP COMPARTMENT HIGH WARNING ILLUMINATED. FOUND RT ACM FAILED. R & R ACM IAW CARD 21-94-02.SDR AALA20150903015Pump · faultyAIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB THE CTR FUEL PRESS LOW LIGHT ILLUMINATED. BOTH CTR FUEL PUMPS INOPERATIVE. R & R AFT CTR FUEL BOOST PUMP IAW AMM 28-20-07-201 & AMM 57-30-03-401. OPERATIONAL & LEAK CHSDR AALA20150903011Stop Fitting · crackedFORWARD CARGO DOOR, FWD LOWER DOOR STOP PAD CRACKED. INSTALLED NEW CARGO DOOR STOP PAD IAW AARD 51-00-01.SDR AALA20150903007Beam · crackedFORWARD ENTRY DOOR NR 6, BEAM IS CRACKED AT FASTENER HOLE, CTR BRACKET. STOP DRILLED CRACK & INSTALLED DOUBLER IAW AARD 52-10-00.SDR AALA20150903006Membrane · crackedE & E COMPARTMENT, 2 EACH CRACKS IN SUB-FLOOR MEMBRANE, STATION 180 APPROX 31" LT OF FLOOR CENTERLINE. INSTALLED DOUBLER IAW AARD 53-20-00-16 & EA 2545278 DATED 09 02 2015.SDR WX0A2015090372844Frame · crackedDURING A CFT LAYOVER, THE FS 1416 CANTED BULKHEAD WAS FOUND WITH A CRACK IN THE FRAME WEB. THE CRACK IS LOCATED APPROX BETWEEN LONGERON 4R - 5R & MEASURES APPROX 2.55 INCHES LONG, GOING THROUGH ONE FASTENER LOCATION. THE FRAME WEB IS MADE FROM 7075-T6 CLAD ASDR AALA20150902004Pressure Switch · malfunctionedDURING CLIMB THE CTR FUEL PRESS LOW LIGHT ILLUMINATED. AIR INTERRUPT, EMERGENCY NOT DECLARED, LANDING UNEVENTFUL. R & R FWD CENTER FUEL PRESSURE SWITCH IAW AMM 28-41-01. OPS & LEAK CHECKED OK.SDR AALA20150901009Shear Tie · crackedCRACKED SHEAR TIE AT STATION 1437, OTBD OF LT FITTING. REPLACED SHEAR TIE.SDR AALA20150901008Shear Tie · crackedSHEAR TIE CRACKED AT STATION 1437, OTBD OF RT FITTING. REPLACED SHEAR TIE.SDR AALA20150901007Intercostal · crackedCABIN CTR FLOORBOARD INTERCOSTAL STATION 1287 - 1309 IS CRACKED. REMOVED & INSTALLED NEW INTERCOSTAL.SDR AALA20150902003Light · inoperativeL1 DOOR, EMER LIGHT FAILS TO TEST. REPLACED LIGHT ASSEMBLY. OPERATIONALLY CHECKED NORMAL.SDR AALA20150831006Beam · corrodedAFT CARGO DOOR BEAM CORRODED STATION 1155 - 1212. INSTALLED BEAM DOUBLER IAW AARD 53-10-00-3.SDR AALA20150831001Cargo Track · corrodedAFT CARGO LT TIE DOWN TRACK CORRODED STATION 1117 - 1136. INSTALLED NEW SECTION OF AFT CARGO LT TIE DOWN TRACK SECTION.SDR 2WAA20150830009Control Valve · inoperativeAT 10,000 FEET, PRESSURIZATION FLOW LIGHT CAME ON, RETURNED TO DEPARTURE. T/S LT PACK CONTROL VALVE IAW AMM 21-31-02, PAGE 208, PARA 5 AND FOUND NOT OK FOR SERVICE. TRANSFERRED LT PACK FLOW CONTROL VALVE TO DMI 3097 IAW MEL 21-7, CAT "C" DUE 09/09/15. DDPG COSDR WX0A2015090172842Battery · dischargedROW 10 - 11 FED OVERHEAD EMER LIGHTS WON’T TURN OFF. R & R ROW 10 - 11 FED OVERHEAD EMER LIGHT BATTERIES IAW AMM 33-50-00. OPERATIONS CHECKED GOOD.SDR AALA20150829003Casting · crackedLEFT WING GND SPOILER ACTUATOR SUPPORT CASTING CRACKED. COMPLETED REPLACEMENT OF GND SPOILER CASTING IAW SRM 51-01-00-001.SDR WX0A2015090172841Light · inoperativeAFT FLIGHT ATTENDANT EMER EXIT LIGHTED SIGN INOPERATIVE. FOUND LIGHT TO BE DEACTIVATED IAW WDM 33-51-14.SDR WX0A2015090172840Skin · damagedON WAKE UP, FOUND LT HORIZONTAL STAB DAMAGED, NO OTHER INFORMATION AVAILABLE. ACFT ON GND & BEING REPAIRED, WILL SUBMIT ADDITIONAL INFORMATION WHEN AVAILABLE. WE HAVE AN AOG SITUATION WITH THE LT HORIZONTAL STAB SIDE LOAD STRUCTURE ASSEMBLY. THERE ARE NO RESDR AALA20150831002Seat Track · corrodedCABIN SEAT TRACK NR 3 CORRODED OUT OF LIMITS FROM STATION 1221 - 1309. COMPLETED INSTALLATION OF NEW SECTION OF NR 3 SEAT TRACK IAW SRM 53-05-00 FIG 4F.SDR AALA20150828006Frame · crackedFUSELAGE FRAME AT STATION 37, BULKHEAD IS CRACKED AT LT LOWER RADOME ALIGNMENT PIN LOCATION. INSTALLED DOUBLER REPAIR IAW AARD 53-10-00 REPAIR 19.SDR AALA20150828005Stop Fitting · crackedFORWARD CARGO DOOR STOP FITTING CRACKED, FWD SIDE OF DOOR, 2ND FROM BOTTOM. R & R FITTING IAW AARD 51-00-05-1, DWG 5910141 & DWG CDK2345.SDR 2CCA15082901926Fitting · crackedDURING HEAVY MAINTENANCE, 48 MO STRUCTURAL INSPECTION, MPD TASK 55-057-02-01, FOUND LT ELEVATOR GEARED TAB MOUNT FITTING CRACKED. R & R FITTING IAW AMM/SRM.SDR 2WAA20150827007Interphone · inoperativeCOCKPIT PA LIGHT DOES NOT STAY ON WHEN PRESSED. UNABLE TO USE PA INTERPHONE.SDR AALA20150827012Cusp Web · crackedRIGHT CUSP SHEET IS CRACKED BETWEEN STATIONS 218 & 237. R & R CUSP SHEET IAW AARD 51-00-05-1 & DWG 9930538.SDR AALA20150827010Seat Track · corrodedSEAT TRACK NR 6 CORRODED, BETWEEN STATIONS 218 & 588. R & R SEAT TRACK SECTION, BETWEEN STATIONS 216 & 588 IAW AMM 53-40-01-2.
Back to Boeing DC-9-83