Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2012052100793Battery · weakRT EXIT SIGN (TOP) & FWD CENTER EXIT SIGN INOP. T/S FOUND BAD BATTERY IN BOTTOM COAT CLOSET LOCATION R & R BATTERY. OPS CK GOOD IAW AMM 33-52-00 & W/C 33-50-03Q.SDR HNAA201205210079Shroud · crackedHOLE IN OTBD FWD SIDE OF NR 1 EXHAUST FINGER NAIL. R & R LT EXHAUSTS SHROUD WITH RETAINED FASTENERS.SDR HNAA2012052100791Pseu · faultedLEFT MLG AMBER DOOR LIGHT REMAINED ILLUMINATED AFTER MLG RETRACTION, CYCLED GEAR IAW CHECK LIST, ALL INDICATIONS ARE NORMAL. PERFORMED PSEU TEST FOUND CODE 54 CARD FAULT. R & R PSEU,CYCLED GEAR OPS CHECKED GOOD. ALSO CHECKED RIGGING OF DOOR SENSOR, NO DEFECSDR HNAA2012051400778Power Supply · intermittentEMERGENCY LIGHT COME ON AND THEN GO OFF AFTER A FEW SECONDS. PATH LIGHTING STAYS ON. R & R EMERGENCY LIGHT POWER SUPPLY UNIT IAW WC 33-50-05R.SDR HNAA2012051400777Battery · failedAFT CEILING AISLE EMERGENCY LIGHT AND LT AFT EMERGENCY EGRESS LIGHT ARE INOPERATIVE. R & R BATTERY ABOVE ROW 3AC. OPS CHECKED GOOD.SDR HNAA2012051400776Battery · failedLEFT FORWARD EMERGENCY EGRESS LIGHT AT AIRSTAIR DOOR IS INOP. R & R LIGHT BATTERY-TOP POSITION IN WARDROBE. OPS CHECKED GOOD.SDR HNAA2012051400774Indicator · failedSMOKE IN COCKPIT DURING FLIGHT. PERFORMED EMERGENCY CHECKLIST. SMOKE DID NOT DISSIPATE. DECLARED EMERGENCY. LANDED NORMALLY. FOUND CAPTAIN`S IVSI INOPERATIVE AND SCREEN BLANK. R & R IVSI. OK FOR SERVICE.SDR HNAA2012051400773Wire · looseROLL SPOILER INBD HYD CAUTION LIGHT ILLUMINATED IN FLIGHT. REPLACED CONNECTOR ON INBD ROLL SPOILER HYD PRESSURE SWITCH IN NR 1 NACELLE. GROUND RAN ACFT. COULD NOT DUPLICATE ON GROUND IAW -8 WIRING MM 27-19-01 AND MM 33-12-00. ALSO FOUND LOOSE WIRE AT CONNECSDR HNAA2012051400772Servo · malfunctionedAPPROXIMATELY FIVE SECONDS BETWEEN ELEVATOR COMMAND AND ELEVATOR REACTION. FOUND ELEVATOR SERVO MOTOR TIGHT. R & R ELEVATOR SERVO IAW -8 MM 22-13-00. OPS CHECKED SERVO IAW MM 22-10-01 USING STARDARD MX ENGAGING A/P ON GROUND, GOOD.SDR HNAA2012051100771Engine · surgesNR 1 ENGINE TORQUE SURGED ON TAKEOFF ROLL UP TO 99 PERCENT. R & R NR 1 ENGINE HMU AND FUEL PUMP IAW 73-20-01. GROUND RAN ACFT IAW SRT MANUAL. OPS CHECKED GOOD.SDR HNAA2012051100770Bulb · failedEMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 6. R & R EMERGENCY FLOOR PATH LIGHT BULB AT ROW 6. REINSTALLED FLOOR STRIP. OPS CHECKED GOOD.SDR HNAA2012051000769Battery Pack · failedFORWARD FUSELAGE RT EMERGENCY LIGHT IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PS2 IN COAT CLOSET IAW AMM 33-51-00.SDR HNAA2012051000767Windscreen · failedINFLIGHT, CREW NOTICED ELECTRICAL ODOR FROM F/O FRONT WINDOW. SELECTED HEAT TO WARM UP. ODOR DISSIPATED. NO CAUTION LIGHTS. CREW GROUND RAN ACFT. PERFORMED WINDSHIELD HEAT OPS CHECK. RT WINDSHIELD LOAD .06. LT WINDSHIELD NORMAL. REF SEQ NR 2. R & R F/OSDR CA120524002O-Ring · damaged(CAN) UPON TAKEOFF, THE CREW NOTED AN OIL PRESSURE FLUCTUATION ON THE RT ENGINE. THEY ELECTED TO SHUT IT DOWN AND AN UNEVENTFUL SINGLE ENGINE LANDING WAS MADE AT THE POINT OF DEPARTURE. POST FLIGHT INSPECTION FOUND AN OIL LEAK DUE TO DAMAGED O-RING ON THE OILSDR CA120511004Shaft · binding(CAN) AFTER LANDING, FLIGHT CREW SELECTED FLAP 0, FLAPS STARTED TO RETRACT BUT STOPPED AT 12 AND FLAP DRIVE CAUTION LIGHT ILLUMINATED. DURING TROUBLESHOOTING, MAINTENANCE FOUND THE RT WING FLEXIBLE SHAFT ASSY LOCATED BETWEEN THE TORQUE SENSOR AND COUPLING NEASDR CA120510004O-Ring · cut(CAN) DURING CLIMB OUT FROM YVO THE RIGHT HAND ENGINE LOSS OIL PRESSURE. THE OIL PRESSURE CAUTION LIGHT ILLUMINATED AND THE CREW SHUTDOWN THE RT ENGINE AND RETURNED TO DEPARTURE. MAINTENANCE FOUND A CUT O-RING TO THE INLET OF THE RT ENGINE OIL COOLER. THE OILSDR HNAA2012050400763Terminal · burnedSTRONG TO VERY STRONG BURNING ODOR NOTICED ONLY IN COCKPIT DURING THE LAST 100 MILES OF FLIGHT AND 5 TO 7 MINUTES THRU TAXI. FOUND F/O WINDSHIELD HEAT POWER LEAD RING TERMINAL HEAT DAMAGED. NO DAMAGE TO WINDSHIELD. R & R TERMINAL SCREW AND WASHER. GROUND RSDR HNAA2012050300762Lamp · failedDIM LEFT EMERGENCY EXIT EGRESS LIGHT. R & R LAMP. OPS CHECKED GOOD.SDR HNAA2012050300761Proximity Sensor · failedUPON GEAR RETRACTION, NOSE GEAR UNSAFE LIGHT ILLUMINATED. PERFORMED EMERGENCY EXTENSION. GOT GEAR DOWN AND LOCKED INDICATION. R & R NOSE GEAR DRAG STAY/UPLOCK PROX SENSOR AND ADJUSTED AS REQUIRED. CYCLED GEAR 20 TIMES. NO DEFECTS NOTED AT THIS TIME. OK FORSDR CA120504001Case · fractured(CAN) DURING THE TAXI OUT, CREW RECEIVED A 1 RUD HYD CAUTION LIGHT AND OBSERVED AN ABNORMAL LOW OIL QUANTITY ON THE ASSOCIATED SYSTEM GAUGE. CREW ELECTED TO RETURN TO THE GATE. MAINTENANCE WAS CALLED AND AN HYDRAULIC LEAK NOTICED UNDER THE LEFT WING. FURTHER SDR CA120502006Diode · burned(CAN) DURING HEAVY MAINTENANCE, VISUAL INSPECTION DIODE 3261-CR2 WAS FOUND BURNED IN HALF. THIS DIODE SUPPLIES DUPLICATE POWER FOR THE LANDING GEAR SYS. IT A LARGE DIODE PROTECTED BY HEAT SHRINK. NO FUNCTION THAT WOULD HAVE INDICATED THIS DIODE WAS FAULTY.SDR CA120501007Shaft · damaged(CAN) A RECENT INVESTIGATION REVEALED THAT 3 PROPELLER SHAFTS THAT WERE NI PLATED WITH EXCESSIVE PLATING TIME PRIOR TO THE PREVIOUS AD CF-2005-29 AND SB 21714 WERE NOT REPORTED AT THAT TIME. 1 OF THESE PROPELLER SHAFTS SHOULD HAVE BEEN INCLUDED IN GROUP 2 OF SDR HNAA2012043000758Contactor · inoperativeEMERGENCY LIGHTS FLICKERED INFLIGHT. R & R 2431-K18 SECONDARY BUSS CONTACTOR IAW STD PRACTICES, OPS CHECKED GOODSDR CA120430004Cap · fractured(CAN) DURING A ROUTINE SERVICE CHECK, A BROKEN PIECE OF METAL WAS NOTICED AT THE NOSE LANDING GEAR SHOCK STRUT LOWER SECTION. FURTHER INVESTIGATION REVEALED THE LIP OF THE SHOCK STRUT CAP 8829-5 HAD FRACTURED. THE CAP, -200 AND LINK -165 WERE REPLACED IAW CMSDR CA120502001Line · leaking(CAN) DURING CRUISE FLIGHT THE NR 2 HYD SYS QTY DROPPED TO ZERO WITH ASSOCIATED CAUTION LIGHTS COMING ON. AN EMERGENCY WAS DECLARED. THE LANDING GEAR WAS LOWERED SUCCESSFULLY WITH THE ALTERNATE EXTENSION SYSTEM AND THE ACFT LANDED UNEVENTFULLY. THE RUDDER RSDR HNAA2012042600755Brush Block · intermittentEMERGENCY LIGHTS FLICKERED INTERMITTENTLY. R & R BOTH PROP BRUSH BLOCKS IAW 61-10-00.SDR HNAA2012042600754Generator · failedLEFT AC "B" PHASE HAS ZERO LOADS AND VOLTS. LT STALL WARNING CAUTION LIGHT. LT PROP "B" PHASE ADVISORY LIGHT DID NOT INDICATE WHEN SELECTED ON. R & R NR 1 AC GENERATOR, GCU AND NR 1 BRUSH BLOCK IAW WC 24-20-11R AND WC 30-61-00. CHECKED GOOD.SDR HNAA2012042600753Pitot Head · failedCAPTAIN LOST AIRSPEED, HEADING DATA AND YAW DAMPER FAILED. REPLACED RUBBER PITOT HOSE BETWEEN CAPTS PITOT TUBE AND FLOOR V THROUGH. R & R CAPT'S PITOT TUBE. OPS CHECKED GOOD IAW MM 34-11-00.SDR HNAA2012042600752Starter Gen · failedNR 1 ENGINE START ASSOCIATED WITH BUSS FAULT. R & R NR 1 START GENERATOR IAW WC 24-30-02R. LEAKED AND OPS CHECKED GOOD.SDR HNAA2012042600751Sensor · malfunctionedWOW CAUTION LIGHT ILLUMINATED INFLIGHT FOR APPROX 1 MINUTE, THEN SELF CLEARED. R & R WOW 1 NLG SENSOR AND WOW 2 SENSOR. TARGET TEST GOOD AT PSEU. OK FOR SERVICE. ADJUSTED IAW AMM 32-20-11.SDR HNAA2012042600750Threshold · corrodedAIRSTAIR DOOR FLOOR THRESHOLD IS CORRODED. REMOVED CORROSION FLOOR THRESHOLD. INSTALLED NEW THRESHOLD ASSY AND RUBBING STRIP IAW 85321241.SDR HNAA2012042600748Bulb · burned outROW 1 FLOOR EMERGENCY PATH LIGHT HAS 1 RED LAMP INOPERATIVE. R & R LIGHT BULB. OPS CHECKED GOOD. REINSTALLED LENS.SDR CA120427003Bracket · cracked(CAN) WHILE CARRYING OUT AN INSPECTION OF ALL FLIGHT CONTROL SPOILER ACTUATOR ATTACH BRACKETS FOR AN IN-HOUSE TASK CARD 5740/99, THE AME FOUND CRACKS ON THE RT SIDE INBD ACTUATOR BRACKET. THE THRESHOLD FOR THIS IN-HOUSE TASK HAS BEEN SET AT 5500 HRS WITH A RSDR CA120502005Control Unit · failed(CAN) UNCOMMANDED FEATHER OF NR 1 ENGINE ON TAXI. ENGINE WAS S/D BY CREW.SDR HNAA2012042300746Wire · brokenRIGHT ELEVATOR HORN HEATER CAUTION LIGHT ILLUMINATED IN FLIGHT, IN ICING CONDITIONS, CAUTION LIGHT EXTINGUISHED AT 200 FEET WITH PLUS 11 DEGREES. R & R BROKEN MATRIX SPLICE BETWEEN 9811P33 PIN TO 3015S2. GROUND RAN IAW RUNUP MANUAL. OPS CHECKED GOOD.SDR HNAA2012042300745Indicator · fluctuatesABORTED TAKEOFF DUE TO NR 1 ENGINE TORQUE FLUX 20-40-PERCENT. OTHER PARAMETERS NORMAL. R & R NR 1 TORQUE INDICATOR IAW MM 77-10-00. GROUND RAN ACFT. OPS CHECKED GOOD AT THIS TIME. OK FOR SERVICE.SDR HNAA2012042000744Bulb · burned outFLOOR PATH EMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R BULB. OPS CHECKED GOOD.SDR HNAA2012042000743Holder · brokenFLOOR EMERGENCY LIGHT HOLDER IS BROKED AT ROW 1DF. R & R HOLDER. OPS CHECKED GOOD.SDR HNAA2012042000742Bulb · burned outFLOOR PATH EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R BULB. OPS CHECKED GOOD.SDR HNAA2012042007401Control Box · malfunctionedEMERGENCY LIGHTS FLICKERED THE ENTIRE FLIGHT. ALL FLOOR EMERGENCY AND ROW 1DF LOWER EXIT SIGN. R & R NR 2 BRUSH BLOCK. OPS CHECKED GOOD IAW MM 30-61-00. R & R EMERGENCY LIGHTS CONTROL BOX IAW MM 33-51-00. OPS CHECKED GOOD. RT TRU WAS ALSO CHANGED.SDR HNAA2012041800739Shaft · corrodedSHAFT ON FORK ASSY THAT ATTACHED TO THE BOTTOM OF LOWER DOOR STRUT ASSY AFT END IS CORRODED. REMOVED SHAFT AND FORK ASSY FROM PAX DOOR STEPS. INSTALLED NEW SHAFT ON FORK ASSY.SDR HNAA2012041800738Post · corrodedLOWER END OF FORWARD POST IS CORRODED. REMOVED LOWER FORWARD POST. REMOVED LIGHT CORROSION ON LOWER END OF FORWARD POST AND INSTALLED ON PAX DOOR SHAFT ASSY.SDR HNAA2012041800736Shaft · corrodedSHAFT ON FORK ASSY THAT ATTACHES TO THE BOTTOM OF LOWER PAX DOOR STRUT ASSY IS CORRODED. REMOVED SHAFT AND FORK ASSY FROM PASSENGER DOOR STEP. INSTALLED NEW SHAFT TO FORK ASSY AND INSTALLED FORK ASSY TO LOWER STRUT ASSY.SDR HNAA2012041807361Bulb · failedONE RED EMERGENCY LIGHT IS OUT AT RT FWD EXIT. RELAMP 1 RED EMERGENCY LIGHT AT RT FWD EXIT. OPS CHECKED GOOD. OK FOR SERVICE.SDR CA120419004Angle · cracked(CAN) WHILE PERFORMING TASK 5310/05, THE AME FOUND A CRACK JUST BELOW THE LT SIDE WINDSHIELD LOWER SILL TIE BEAM AT BS-X123.00+Z 144.00. A DAMAGE REPORT CHECKLIST WAS COMPLETED AND SENT TO TECH HELP DESK. A PERMANENT ALLOWANCE FOR THE CRACK DAMAGE TO THIS LT SDR CA120418003Spring · failed(CAN) CREW REPORTED THEY LOST NR 2 HYDRAULIC FLUID, WITH ASSOCIATED RUDDER ISO CAUTION AFTER CYCLE GEAR FOR LT GEAR DOOR LIGHT AND RETURNING TO DEPARTURE. MAINTENANCE, FOUND LT GEAR OTBD. REAR DOOR PUSHROD AND SPRING FAILED, AND SEVERED HYD LINE CAUSING HYD SDR CA120418002Pushrod · failed(CAN) CREW REPORTED THEY LOST NR 2 HYDRAULIC FLUID, WITH ASSOCIATED RUDDER ISO CAUTION AFTER CYC GEAR FOR LT GEAR DOOR LIGHT AND RETURNING TO DEPARTURE. MAINTENANCE FOUND LT GEAR OTBD REAR DOOR PUSHROD AND SPRING FAILED, AND SEVERED HYD LINE CAUSING HYD SYSTESDR HNAA2012041600735Lamp · failedEMERGENCY FLOOR PATH LIGHTS ARE INOPERATIVE AT ROW 1. R & R EMERGENCY FLOOR PATH LIGHT LAMPS AT ROW 1 AND CLOSED ACCESS PANEL.SDR CA120417001Fitting · cracked(CAN) DURING SCHEDULED INSPECTION OF THE MLG RETRACT JACK FITTING, A CRACK INDICATION WAS FOUND IN THE SPIGOT RADIUS. A NEW FITTING WAS INSTALLED. ACFT RETURNED TO SERVICE.SDR HNAA2012041300732Housing · corrodedFORWARD AND AFT SHAFT BEARING HOUSING CORRODED. R & R WITH NEW HOUSING IAW MFG DWG 85210004.
Back to Boeing DHC-8-102