Cameron Balloons U S A-300
Service difficulty reports · 3,457
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202210063851Battery · noneAIRCRAFT WAS NOT GROUNDED: CIDS EMERGENCY POWER SUPPLY UNIT SYSTEM TEST DISPLAYED FAULT MESSAGE FOR EMERGENCY POWER SUPPLY UNIT 15WL. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 15WL BATTERY PER AMM 33-51-38. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISSDR AALA202210136447Apu · overservicedAIRCRAFT WAS GROUNDED: MILD TO MODERATE OIL ODOR NOTICED IN FLIGHT DECK AND CABIN. ON GROUND WITH APU BLEED AND IN-FLIGHT DURING CRUISE, DESCENT, APROACH AND LANDING. MAINTENANCE FOUND EVIDENCE OF OIL ON APU PLENEUM AND APU AIR INTAKE. **SUPPLEMENTAL REPORT FOSDR AALA202210052287Chiller · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL FLIGHT ATTENDANT REPORTED ACRID , PUNGENT ANTI FREEZE SMELL THAT LASTED 2 TO 3 MINUTES THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DETERMINED THE SOURCE OF THE ODOR WAS THE CHILLER. **SUPSDR AALA202210042287Chiller · odorAIRCRAFT WAS NOT GROUNDED: ON FINAL FLIGHT ATTENDANT REPORTED ACRID , PUNGENT ANTI FREEZE SMELL THAT LASTED 2 TO 3 MINUTES THEN DISSIPATED. MAINTENANCE FOUND AFT GALLEY CHILLER CIRCUIT BREAKER POPPED AND DETERMINED THE SOURCE OF THE ODOR WAS THE CHILLER. **SUPSDR AALA202210046447Apu · odorAIRCRAFT WAS GROUNDED: MILD TO MODERATE OIL ODOR NOTICED IN FLIGHT DECK AND CABIN. ON GROUND WITH APU BLEED AND IN-FLIGHT DURING CRUISE, DESCENT, APROACH AND LANDING. MAINTENANCE FOUND EVIDENCE OF OIL ON APU PLENEUM AND APU AIR INTAKE. **SUPPLEMENTAL REPORT WISDR AALA202210032129Battery · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 13WL BATTERY FAILED SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202210036165Battery · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 14WL BATTERY FAILED SYSTEM TEST. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202210033427None · low pressureAIRCRAFT WAS NOT GROUNDED: CIDS PANEL DISPLAYING CHECK 4L DOOR PRESSURE. MAINTENANCE SERVICED 4L DOOR ASSIST BOTTLE PER AMM 52-10-00SDR AALA202210032504Slide · noneAIRCRAFT WAS GROUNDED: DURING CIDS BITE TEST: ESCAPE SLIDE LIGHT/EMERGENCY POWER SUPPLY UNIT (15WL) MID LEFT MESSAGE DISPLAYED. MAINTENANCE ACCOMPLISHED TSM 25-62-00-810-815A AND REPLACED THE 2L DOOR SLIDE PER TASK CARD 26L00025012. A SATISFACTORY OPERATIONAL SDR AALA202210037945None · low pressureAIRCRAFT WAS GROUNDED: FORWARD FLIGHT ATTENDANT PANEL SHOWS CHECK DOOR PRESSURE FOR 2R. MAINTENANCE SERVICED 2R DOOR ASSIST BOTTLE PER AMM 52-22-00.SDR AALA202210033898Lever · noneAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS 2L MID CABIN EMERGENCY EXIT DOOR ARM LEVER IS CROOKED. MAINTENANCE ADJUSTED ARM/DISARM LEVER FOR L2 EXIT DOOR PER AMM 52-22-22.SDR AALA202210035003Wire · brokenAIRCRAFT WAS GROUNDED: ISLE EMERGENCY LIGHTS AT SEAT ROW 32, 33 AND 34 ARE OUT. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT BATTERIES AT EMERGENCY POWER SUPPLY UNIT 11WL (AALA202210036600) AND EMERGENCY POWER SUPPLY UNIT 15WL (AALA202210037569) PER AMM 33SDR AALA202210037569Battery · noneAIRCRAFT WAS GROUNDED: ISLE EMERGENCY LIGHTS AT SEAT ROW 32, 33 AND 34 ARE OUT. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT BATTERIES AT EMERGENCY POWER SUPPLY UNIT 11WL (AALA202210036600) AND EMERGENCY POWER SUPPLY UNIT 15WL (AALA202210037569) PER AMM 33SDR AALA202210036600Battery · noneAIRCRAFT WAS GROUNDED: ISLE EMERGENCY LIGHTS AT SEAT ROW 32, 33 AND 34 ARE OUT. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT BATTERIES AT EMERGENCY POWER SUPPLY UNIT 11WL (AALA202210036600) AND EMERGENCY POWER SUPPLY UNIT 15WL (AALA202210037569) PER AMM 33SDR AALA202210036446Power Supply · noneAIRCRAFT IN BASE MAINTENANCE: DURING THE OPERATIONAL TEST OF EMERGENCY LIGHTS, EMERGENCY POWER SUPPLY UNIT 13WL FAILED TO COMMUNICATE WITH THE CIDS. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 13WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMMSDR CALA2022093002581Panel · crackedCTR FUSELAGE LH FR 36 PRESSURE PANEL CRACKED I/B HOLES #9, #20, #26 ACCOMPLISHED ON VTMAE NR 36413 BY VTMAE EMPLOYEE V933870. N PRESSURE PANEL HOLES AREA PER PART 2 OF THE LATEST REVISION OF OR BEFORE MARCH 23, 2023, PERFORM AN INSPECTION OF THE LH FR 36 ECRA SDR CALA2022093002580Fastener · missingPDA 3 REF LOG PAGE 9639140 CREW REPORTED MISSING FASTENER, REF ORIGINAL LOG PAGE 9639140 MISSING FASTENER REPLACED.SDR CALA2022093002579None · noneAFT PIT, THRESHOLD METAL STICKING UP EF5300010-1 REF. ECRA 5322-01050 REV. H AND INITIATED A DIP TO REPAIR WITHIN 7 CALENDAR DAYS. REINSPECT TAPE PER PART 2 DAILY AND TO PERFORM PART 3 PERMANENT COMPLIED WITH PART 1C INTERIM REPAIR, TRIMMED AND TAPED THRESHOLDSDR AALA202210036568Engine · stalledAIRCRAFT WAS GROUNDED: ENGINE 2 STALL INDICATION AT CRUISE ECAM WITH A 3 TO 4 SECOND POWER DECREASE HOWEVER NO AUDIBLE BANG WAS HEARD. MAINTENANCE ACCOMPLISHED INSPECTION OF THE ENGINE AND FOUND EXTENSIVE DAMAGE TO THE 3RD AND 8TH STAGE HPC BLADES. REPLACED #2SDR AALA202210038163Battery · noneAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 14WL FAULT DURING CIDS EMERGENCY POWER SUPPLY UNIT SYSTEM TEST. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY UNIT 14WL BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202209304999None · lowAIRCRAFT WAS GROUNDED: L4 DOOR ASSIST BOTTLE LOW. MAINTENANCE SERVICED L4 DOOR ASSIST BOTTLE PER AMM 52 -10-00.SDR AALA202209308782Cylinder · low pressureAIRCRAFT WAS GROUNDED: CIDS CAUTION LIGHT ILLUMINTATED FOR R4 DOOR. MAINTENANCE SERVICED R4 DOOR EMERGENCY OPERATION CYLINDER PER AMM 52-10-00-614-001-A.SDR AALA202209306399Cylinder · low pressureAIRCRAFT WAS GROUNDED: CIDS CAUTION LIGHT ILLUMINTATED FOR L3 DOOR. MAINTENANCE SERVICED L3 DOOR EMERGENCY OPERATION CYLINDER PER AMM 52-10-00-614-001-A.SDR CALA2022093002571None · crackedLEFT FR 68 AT STR 22 (UNDERSIDE) HAS CRACK INDICATION ALONG RADI US OF STR FLANGE, .30 INCHES FROM CAP, .70 INCHES LONG. GENERATE D BY V892444 ON HAECO LCQ NR 9290411/40411 LISH INITIAL INSPECTIONS ON FRAME REPAIR AT LH FR68 STR22 PER PA AIRCRAFT REACHES 54,08SDR CALA2022093002570None · crackedRIGHT FR 68 AT STR 22 (UNDERSIDE) HAS CRACK INDICATION ALONG RAD IUS OF STR FLANGE, .40 INCHES FROM CAP, .50 INCHES LONG. GENERAT ED BY V892444 ON HAECO LCQ NR 9290412/40412 PLISH INITIAL INSPECTIONS ON FRAME REPAIR AT RH FR68 STR22RH PER THE AIRCRAFT REACHES SDR CALA2022093002569None · corrodedCORROSION ON RH DOOR SILL AT FR68 INBD CORNER (2 PLACES). GENERA TED BY V892443 ON HAECO LCQ NR 9290188/40188 CORROSION REMOVAL RH DOOR SILL AT FR 68 FOUND TO BE BEYOND LIMIT S IAW A320 SRM 53-41-14-283-002, REMOVED AND REPLACED R2 DOOR SI LL FR 66-68 STR 23R SDR AALA202209296849Battery · noneAIRCRAFT WAS NOT GROUNDED: FORWARD LEFT DOOR EMERGENCY POWER SUPPLY UNIT 10WL BATTERY FAULT. REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202210100343Apu · overservicedAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED STRONG ELECTRICAL / BURNING PLASTIC SMELL IN THE FLIGHT DECK / CABIN INBOUND TO CLT AND AT THE GATE AFTER ENGINE SHUTDOWN. MAINTENANCE FOUND EVIDENCE OF AN APU OIL LEAK AT THE INLET AND DETERMINED THE APU WAS THE SOUSDR AALA202210031005Door · detachedAIRCRAFT WAS GROUNDED: AFTER LANDING AT PVD, A LOOSE CATERING CART FROM THE REAR OF THE FUSELAGE ROLLED FORWARD AND SLAMMED INTO THE FLIGHT DECK DOOR, TEARING OFF THE DOOR FROM ITS HINGES. MAINTENANCE REPLACED THE FLIGHT DECK DOOR PER AMM 52-51-11.. (NOTE: ENGSDR YENA2022093000978Detector · failedFLT#1621, LHR-BOS. (ETOPS) 'ENG 1 FIRE LOOP "A" FAULT; PERFORMED FIM TASK 26-12-00-810-803-A FOUND AGB CORE LOOP A SHORTED TO GROUND. REMOVED AND REPLACED AGB CORE LOOP A 4002WD1 IAW AMM 26-12-17-000-802. OPS CHECK GOOD AT THIS TIME.' (SUPPLEMENTAL INFORMATIONSDR AALA202209309956Cooling Fan · leakingAIRCRAFT WAS GROUNDED: WITH THE RIGHT HAND ENGINE GENERATOR INOPERATIVE AND ON MEL, THE APU AUTO SHUT DOWN ON INITIAL CLIMBOUT AT FL 290. THE AIRCRAFT RETURNED TO PDX AND DECLARED AN EMERGENCY DUE TO THE AIRCRAFT WAS DOWN TO 1 GENERATOR. THE AIRCRAFT LANDED SASDR AALA202209301860Light · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT AT SEAT 16C INOPERATIVE. MAINTENANCE REPLACED EMERGENCY LIGHT AT SEAT 16C AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-50-00.SDR AALA202209301901None · contaminatedAIRCRAFT WAS GROUNDED: WITH THE RIGHT HAND ENGINE GENERATOR INOPERATIVE AND ON MEL, THE APU AUTO SHUT DOWN ON INITIAL CLIMBOUT AT FL 290. THE AIRCRAFT RETURNED TO PDX AND DECLARED AN EMERGENCY DUE TO THE AIRCRAFT WAS DOWN TO 1 GENERATOR. THE AIRCRAFT LANDED SASDR CALA2022093002565None · crackedCRACK INDICATION ON FRAME 68 WEB HORIZONTAL FLANGE AT STGR22 LEVEL LH SIDE, CRACK LENGHT IS 1.218 INCH APPROX, CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS BEFORE NEXT FLIGHT AT AFT GALLEY AREA (1 EA) SEE AEROMAN NON ROUTINE 2022-308627 NITIAL INSPECTIONS OF RSDR CALA2022093002564Skin · noneDURING PERFORMED AGING AIRCRAFT INSPECTION FOUND EXISTING REPAIR DOUBLER LOCATED LOWER FUSELAGE SKING AT FR31 TO FR32 BTW 38L TO STRG 39L. SEE AEROMAN NON ROUTINE 2022-308900 01-E FIGURE 005 VIEW B (SHEET 02) DOUBLER REPAIR MATERIAL: DAMAGE IAW NTM 51-90-00, TSDR CALA2022093002562None · corrodedCORROSION LOWER SILL LOCATED FR66 AT AFT GALLEY AREA SEE AEROMAN NON ROUTINE 2022-308753 MEASURES AFTER REWORK WAS L:2.388 INCH W:1.169 INCH, ELECTRONIC CRACK AND CORROSION INDICATION NOT FOUND, IAW SRM A320 53-41-14-283-002 FIGURE 002 SHEET 01, THIS IS CALIPSDR AALA202209290343Apu · odorAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED STRONG ELECTRICAL / BURNING PLASTIC SMELL IN THE FLIGHT DECK / CABIN INBOUND TO CLT AND AT THE GATE AFTER ENGINE SHUTDOWN. MAINTENANCE FOUND EVIDENCE OF AN APU OIL LEAK AT THE INLET AND DETERMINED THE APU WAS THE SOUSDR AALA202209299956Apu · shutdownAIRCRAFT WAS GROUNDED: WITH THE RIGHT HAND ENGINE GENERATOR INOPERATIVE AND ON MEL , THE APU AUTO SHUT DOWN ON INITIAL CLIMBOUT AT FL 290. THE AIRCRAFT RETURNED TO PDX AND DECLARED AN EMERGENCY DUE TO THE AIRCRAFT WAS DOWN TO 1 GENERATOR. THE AIRCRAFT LANDED SSDR AALA202209291901None · low pressureAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS L2 DOOR ASSIST BOTTLE LOW. MAINTENANCE SERVICED L2 DOOR ASSIST BOTTLE PER AMM 52-22-00.SDR CALA2022092802530None · noneLEVEL 1 CHRONIC - DOOR 2 RIGHT DOES NOT INDICATE ARMED ON DOOR/OXY PAGE WITH DOOR LOCKED AND ARMED. PLEASE T/S PER TSM 52-13-00-810-805-A. IF FAULT CANNOT BE DUPLICATED AND NO OTHER ISSUES ARE FOUND, PLEASE REPLACE PROX SW 7WN2. REPORT ALL FINDINGS AND ACTION SDR CALA2022092802529Fastener · missingPDA 3 FASTENER MISSING ON LEFT LOWER AILERON TRAILING EDGE. SEE PHOTO. ADDED PHOTO. UPON FURTHER INVESTIGATION LOWER AILERON HAVE FASTENER INSTALLED. NO DEFLECT FOUNDSDR CALA2022092802527Drain Line · noneTR 2 INDICATIONS INOP ON ELEC SYSTEM ECAM PAGE - ELEC TR2 FAILED APROX 100KTSON TAKE OFF. DURING T/S NOTED ACTIVE WATER LEAK DIRECTLY ABOVE TR2 IN SUSPECT LEAK COMING FROM FORWARD GALLEY AREA AND NEEDS TO BE LEAK APPEARS TO BE COMING FROM #1 GALLEY WATER DRAINSDR CALA2022092802526None · corrodedBRAKE ACCUMULATOR BLEEDING OFF WITH PARKING BRAKE SET. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN MAC METER INITIATED FOR WITH VENDOR ID V926493 PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. CHECK ACCUM MAC RELATED WORK ORDER 000000003057621 AND PRTR NSDR CALA2022092802528Doubler · noneDURING PERFORMED AGING AIRCRAFT INSPECTION FOUND EXISTING REPAIR DOUBLER LOCATED LOWER FUSELAGE SKING AT FR31 TO FR32 BTW 38L TO STRG 39L. SEE AEROMAN NON ROUTINE 2022-308900 01-E FIGURE 005 VIEW B (SHEET 02) DOUBLER REPAIR MATERIAL: DAMAGE IAW NTM 51-90-00, TSDR AALA202210033993Apu · odorAIRCRAFT WAS GROUNDED: A DIRTY OILY RAG SMELL COMING FROM THE AIR VENTS WAS REPORTED BY THE FLIGHT ATTENDANTS DURING BOARDING AND THE ODOR CONTINUED THRU ALL PHASES OF THE FLIGHT. MAINTENANCE FOUND EVIDENCE OF OIL ON THE APU PLENUM INTAKE AREA AND DETERMINED SDR AALA202209285396Door · out of adjustAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY ENTRY DOOR DIFFICULT TO OPEN AND CLOSE. MAINTENANCE ADJUSTED DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-51-21.SDR AALA202209284202Slide · deformedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND FORWARD SLIDE HITS FUSELAGE WHEN DOOR IS OPEN. REPLACED SLIDE PER TASK CARD 26L00025010.SDR AALA202209280230Gust Lock · lack of lubeAIRCRAFT WAS NOT GROUNDED: GATE AGENT REPORTED DOOR L1 DIFFICULT TO OPERATE. MAINTENANCE LUBRICATED GUST LOCK MECHANISM AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-10-00.SDR CALA2022092802541None · noneFABRICATE CLEAT FOR FWD CARGO PIT FR30 PER HAECO LCQ N/R 9290783 /30783 GEN BY V052030 REMOVED AND REPLACED CLEAT AT FRAME 30 BETWEEN STRINGERS 42R-43R IN THE FORWARD CARGO BAY IAW A320 SRM 51-72-11 BY MECH V052030 I NSP BY V061647SDR CALA2022092802539Floor Support · noneCORROSION LOWER SILL LOCATED FR66 AND STR 23L IN PASSENGER CABIN.SEE AEROMAN NON ROUTINE 2022-308750 PERFORMED PERMANENT REPAIR ON LOWER SILL LOC. AT FR.66 AND STR. AREA IS: 0.091", NOMINAL THICKNESS ON AREA IS: 0.150" PERFORMED IAW NTM NTM 51-10-02 AND NTM 51
Back to Cameron Balloons U S A-300