SDR VNAA0209033Light · looseTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING AT ROW 4 TO 6 WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND RESECURED THE EMERGENCY FLOOR LIGHTING STRIP IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THESep 23, 2002 · N425JS · Dorner DO328100 · Emergency LightingSDR VNAA0209032Battery · dischargedTHE CREW REPORTED THAT THE LAST ROW OF EMERGENCY FLOOR LIGHTING WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 7LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS Sep 23, 2002 · N437JS · Dorner DO328100 · Emergency LightingSDR VNAA0209031Generator · failedDURING TAKE OFF, THE CREW RECEIVED A LEFT HAND DC GENERATOR FAIL CAS MESSAGE AND ABORTED TAKE OFF. MAINTENANCE INSPECTED AND CLEANED THE GENERATOR CANNON PLUG AND SWAPPED GENERATOR CONTROL UNITS FROM SIDE TO SIDE IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL Sep 22, 2002 · N424JS · Dorner DO328100 · Electrical Power SystemSDR VNAA0209030Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING AT ROWS 7 TO 9 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 6LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT Sep 22, 2002 · N459PS · Dorner DO328100 · Emergency LightingSDR A6WA200230034Channel · crackedCENTER AISLE FLOOR CHANNEL .28 INCH CRACK AT CENTER SCREW LOCATION ON FRAME 17. MAINTENANCE REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS AND INSTALLED REF DO328 SRM 53-00-50 AT FRAME 17. (M)Sep 20, 2002 · N328MX · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230033Channel · crackedCENTER AISLE FLOOR CHANNEL CRACKED .25 INCH AT CENTER SCREW LOCATION ON FRAME 18. MAINTENANCE REMOVED DAMAGED AREA FABRICATED REPAIR PARTS AND INSTALLED REF DO328 SRM 53-00-50 AT FRAME 18. (M)Sep 20, 2002 · N328MX · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230032Floorbeam · corrodedLAVATORY AREA FRAME 35 CORRODED BEYOND LIMITS. MAINTENANCE REMOVED FLOOR FRAME 35 AT LAVATORY AREA. FABRICATED REPLACEMENT FRAME AND INSTALLED REF HHC-02-348 REPAIR PROCEDURE AND DO328 SRM 51-10-01. (M)Sep 20, 2002 · N328MX · Dorner DO328100 · Fuselage Main, Floor BeamSDR A6WA200230031Floor Support · crackedWHILE CLEANING CORROSION FROM TWO CLIP NUT ATTACHED HOLES ON FRAME 38 FOUND TWO HOLES IN FLOOR SUPPORT ANGLE TO BE CRACKED. MAINTENANCE STOP DRILLED CRACKS AT FRAME 38. FABRICATED AND INSTALLED REPAIR DOUBLER REF HHC-02-349. REPAIR PROCEDURE AND SRM DO328 SSep 20, 2002 · N328MX · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230035Floorbeam · crackedFLOOR BOARD SCREW HOLE ON FRAME 14 CRACKED AT CENTER AISLE 4H SIDE. MAINTENANCE REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS AND INSTALLED RED DO328 SRM 53-00-50 AT FRAME 14. (M)Sep 20, 2002 · N328MX · Dorner DO328100 · Fuselage Main, Floor BeamSDR VNAA0209029Light · looseTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING AT ROWS 10 TO 12 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND RESECURED THE EMERGENCY FLOOR LIGHTING IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRSep 20, 2002 · N457PS · Dorner DO328100 · Emergency LightingSDR A6WA200230030Door Frame · corrodedBOTTOM OF CARGO DOOR FRAME UNDER THRESHOLD PLATE HAS CORROSION. MAINTENANCE REMOVED AND BLENDED CORROSION ON UPPER SURFACE OF CARGO DOOR FRAME THRESHOLD (DOORSILL). FABRICATED AND INSTALLED REPAIR DOUBLER REF REPAIR PROCEDURE HHC-02-358. (M)Sep 19, 2002 · N328MX · Dorner DO328100 · Cargo/Baggage DoorsSDR VNAA0209028Control Unit · failedON SHORT FINAL, THE CREW RECEIVED A NOSE WHEEL STEERING FAIL CAS MESSAGE AND DECIDED TO DO A MISSED APPROACH. THE CREW RESET THE SYSTEM IN ACCORDANCE WITH THE QUICK REFERENCE HANDBOOK AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NOSE WSep 19, 2002 · N438JS · Dorner DO328100 · Landing Gear SystemSDR VNAA0209027Control Unit · failedON SHORT FINAL, THE CREW RECEIVED A NOSE WHEEL STEERING FAIL CAS MESSAGE AND DECIDED TO DO A MISSED APPROACH. THE CREW RESET THE SYSTEM IN ACCORDANCE WITH THE QUICK REFERENCE HANDBOOK AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NOSE WSep 19, 2002 · N438JS · Dorner DO328100 · Landing Gear Steering SystemSDR VNAA0209026Pseu · failedDURING CLIMB OUT, THE CREW RECEIVED A PROXY SYSTEM FAIL CAS MESSAGE AND WERE INSTRUCTED TO RETURN TO PIT. MAINTENANCE INSPECTED AND REPLACED THE PSEU IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 32-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT Sep 18, 2002 · N472PS · Dorner DO328100 · Landing Gear SystemSDR VNAA0209025Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING AT ROW 11 WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 7LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RESep 17, 2002 · N470PS · Dorner DO328100 · Emergency LightingSDR VNAA0209024Propeller · failedDURING CLIMB, THE CREW NOTICED A VIBRATION SUSPECTED FROM THE LEFT HAND PROPELLER AND RETURNED TO PIT. MAINTENANCE INSPECTED AND THEN BALANCED THE LEFT HAND PROPELLER IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 61-00-00. OPERATIONAL CHECKS WERE PERFORMED ASep 16, 2002 · N423JS · Dorner DO328100 · Propeller SystemSDR VNAA0209023Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY LIGHTING AT ROW 9 WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 7LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED Sep 16, 2002 · N457PS · Dorner DO328100 · Emergency LightingSDR VNAA0209022Light · inoperativeTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING STRIP WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE LIGHTING STRIP IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR Sep 15, 2002 · N457PS · Dorner DO328100 · Emergency LightingSDR VNAA0209019Control Unit · malfunctionedDURING LANDING, FLIGHT 4180 EXPERIENCED A NOSE WHEEL STEERING FAIL CAS MESSAGE AND EXECUTED A MISSED APPROACH. THE CREW FOLLOWED THE QUICK REFERENCE HANDBOOK AND TURNED OFF THE NOSE WHEEL STEERING AND ANTI-SKID. FLIGHT 4180 THEN LANDED WITH NO FURTHER INCIDESep 15, 2002 · N438JS · Dorner DO328100 · Landing Gear Steering SystemSDR VNAA0209018Circuit Breaker · trippedFLIGHT 4056 WAS ON THE RUNWAY READY FOR TAKEOFF AND RECEIVED A LEFT HAND PACK OVERHEAT MESSAGE AND ABORTED TAKEOFF. MAINTENANCE INSPECTED AND RESET THE L2 CIRCUIT BREAKER IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 21-00-00. OPERATIONAL CHECKS WERE PERFORMSep 15, 2002 · N432JS · Dorner DO328100 · Cabin Cooling SystemSDR VNAA0209017Warning System · malfunctionedDURING TAKEOFF, THE CREW EXPERIENCED A DISPLAY UNIT 5 AND A WEIGHT ON WHEELS 1 FAIL CAS MESSAGE AND ABORTED TAKEOFF. MAINTENANCE INSPECTED AND HAD THE CREW CYCLE THE POWER THEN PERFORMED OPERATIONAL CHECKS IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 31-00-0Sep 14, 2002 · N461PS · Dorner DO328100 · Central WarningSDR VNAA0209016Battery · overheatedAFTER TAKEOFF, THE CREW RECEIVED A NR 2 MAIN BATTERY OVERHEAT CAS MESSAGE AND RETURNED TO BNA. MAINTENANCE WAS DISPATCHED, INSPECTED, AND REPLACED THE NR 2 MAIN BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONAL CHECKS WERE PERFORMEDSep 14, 2002 · N459PS · Dorner DO328100 · Battery/Charger SystemSDR A6WA200230028Floor Support · corrodedFLOOR SUPPORT BEAM AT FRAME 36 RIGHT SIDE OUTBOARD FLANGE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED CORROSION DAMAGE AT FRAME 36. FABRICATED REPAIR PARTS AND INSTALLED RED DO328 SRM 53-00-50 FLANGE REPAIR. (M)Sep 10, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230027Cap · crackedROW 1DF SEAT BOTH HAVE CRACKED INBOARD ATTACH CAPS. MAINTENANCE REMOVED AND REPLACED ROW 1 DF INBOARD ATTACH CAPS RED DO328 SRM 51-43-20. (MSep 10, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230029Floor Support · corrodedFLOOR SUPPORT AT FRAME 38 HAS MINOR SURFACE CORROSION MAINTENANCE REMOVED CLIP NUTS FROM AFFECTED HOLES ON FRAME 38 FLOOR SUPPORT, REMOVED CORROSION FROM AREA BY MECHANICAL MEANS, ETCHED, ALODINED, PRIMED, TOPCOAT AFFECTED AREAS. REINSTALLED CLIP NUTS.Sep 10, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR VNAA0209015Apu · deterioratedTHE CREW REPORTED A BURNING SMELL IN THE COCKPIT THAT SEEMS TO BE COMING FROM THE RIGHT HAND PACK. MAINTENANCE INSPECTED AND FOUND THAT THE APU WAS FAILING THE COMPRESSION CHECK. THE APU WAS THEN DEFERRED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.Sep 10, 2002 · N463PS · Dorner DO328100 · APU Core EngineSDR VNAA0209014Warning System · malfunctionedDURING TAKEOFF, THE CREW RECEIVED AN ECU FAIL CAS MESSAGE AND ABORTED TAKEOFF. THE CREW THEN EXITED THE RUNAWAY AND THE MESSAGE CLEARED BY ITSELF. THE CREW CALLED MAINTENANCE CONTROL AND THE DECISION WAS MADE TO TRY ANOTHER TAKEOFF ATTEMPT. FLIGHT 4123 THENSep 10, 2002 · N439JS · Dorner DO328100 · Central WarningSDR VNAA0209013Ecu · faultyDURING TAKEOFF, THE CREW RECEIVED A NOSE WHEEL STEERING FAIL CAS MESSAGE AND ABORTED TAKEOFF. MAINTENANCE INSPECTED AND REPLACED THE NOSE WHEEL STEERING ELECTRONIC CONTROL UNIT IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 32-00-00. OPERATIONAL CHECKS WERE PSep 10, 2002 · N430JS · Dorner DO328100 · Steering UnitSDR VNAA0209012Connector · dirtyDURING TAKEOFF, THE CREW RECEIVED AN AC VOLT FAIL AND ECU FAIL MESSAGE AND ABORTED TAKEOFF. MAINTENANCE INSPECTED AND CLEANED THE CANNON PLUG ON THE IBV VALVE AND ECU IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 75-00-00. OPERATIONAL CHECKS WERE PERFORMED ASep 10, 2002 · N439JS · Dorner DO328100 · Compressor Bleed ControlSDR VNAA0209010Warning System · malfunctionedDURING TAKEOFF, THE CREW RECEIVED A NOSE WHEEL STEERING CAS MESSAGE AND ABORTED TAKEOFF. THE CREW EXITED THE RUNWAY AND THE MESSAGE CLEARED BY ITSELF. THE DECISION WAS MADE TO ATTEMPT ANOTHER TAKEOFF. FLIGHT 4124 THEN DEPARTED WITH NO FURTHER INCIDENTS.Sep 9, 2002 · N430JS · Dorner DO328100 · Landing Gear Steering SystemSDR VNAA0209009Warning System · malfunctionedDURING TAKEOFF, THE CREW RECEIVED A NOSE WHEEL STEERING CAS MESSAGE AND ABORTED TAKEOFF. THE CREW EXITED THE RUNWAY AND THE MESSAGE CLEARED BY ITSELF. THE CREW CALLED MAINTENANCE CONTROL AND THE DECISION WAS MADE TO ATTEMPT ANOTHER TAKEOFF. FLIGHT 4085 THENSep 9, 2002 · N439JS · Dorner DO328100 · Landing Gear Steering SystemSDR VNAA0209011Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING AT ROWS 4-7 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 5LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WASSep 9, 2002 · N458PS · Dorner DO328100 · Emergency LightingSDR A6WA200230023Floor Support · crackedCENTER AISLE FLOOR SUPPORT BEAM AT FRAME 16 CRACKED AT CENTER SCREW HOLE. MAINTENANCE REMOVED DAMAGED AREA AT FRAME 16. FABRICATED REPAIR PARTS AND INSTALLED REF DO328 SRM 53-00-50 CHANNEL REPAIR. (M)Sep 8, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230024Floor Support · crackedCENTER AISLE FLOOR SUPPORT ROOM AT FRAME 17 CRACKED AT CENTER SCREW HOLE. MAINTENANCE REMOVED DAMAGED AREA AT FRAME 17. FABRICATED REPAIR PARTS AND INSTALLED REF DO328 SRM 53-00-50 CHANNERL REPAIR. (M)Sep 8, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230025Floor Support · crackedCENTER AISLE FLOOR SUPPORT BEAM AT FRAME 18 CRACKED AT CENTER HOLE. MAINTENANCE REMOVED DAMAGED AREA AT FRAME 18. FABRICATED REPAIR PARTS AND INSTALLED REF DO328 SRM 53-00-50 CHANNEL REPAIR. (M)Sep 8, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230022Floor Support · crackedCENTER AISLE FLOOR SUPPORT BEAM AT FRAME 14 CRACKED .28 INCH AT CENTER SCREW HOLE. MAINTENANCE REMOVED DAMAGED AREA AT FRAME 14. FABRICATED REPAIR PARTS AND INSTALLED RED DO328 SRW 53-00-50 CHANNEL REPAIR. (M)Sep 8, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230026Floor Support · crackedCENTER AISLE FLOR SUPPORT BEAM AT FRAME 20 CRACKED AT CENTER SCREW HOLE. MAINTENANCE REMOVED DAMAGED AREA AT FRAME 20. FABRICATED REPAIR PART AND INSTALLED REF DO328 SRM 53-00-50 CHANNEL REPAIR. (M)Sep 8, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230019Rib · crackedLEFT WING LEADING EDGE 512AL HAS A .25 INCH RIB CRACKED ON FLANGE AT TWO PLACES. DAMAGE LOCATED ON 2ND RIB INBOARD. MAINTENANCE REMOVED DAMAGED AREA FROM LEFT LEADING EDGE 512AL RIB. FABRICATED REPAIR PARTS AND INSTALLED REF DO 328 SRM 51-27-0 AND REPAIR PRSep 7, 2002 · N341PH · Dorner DO328100 · Wing, Rib/BulkheadSDR A6WA200230018Sill · corrodedSURFACE CORROSION FOUND ON CARGO DOOR SILL AT ATTACH HOLES FOR SCUFF PLATE. MAINTENANCE REMOVED SURFACE CORROSION ON CARGO DOOR SILL, CORROSION WAS FOUND TO BE OUT OF LIMITS IAW DO 328 SRM 53-51-65. FABRICATED REPAIR DOUBLERS AND INSTALLED AT CARGO DOOR SILLSep 7, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230017Floor Support · corrodedFLOOR SUPPORT AT FRAME 39 HAS MINOR SURFACE CORROSION ON TOP SURFACE AROUND CLIP NUT HOLES. REMOVED LIGHT SURFACE CORROSION FROM FLOOR SUPPORT. REINSTALLED CLIPS. (M)Sep 7, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230016Sink · corrodedTHE LAVATORY SINK HAS CORROSION AT THE SINK STOPPER. MAINTENANCE REMOVED CORROSION ON LAVATORY SINK STOP IAW DO 328 SRM 51-21-00 AND FIXED REPAIR OF PAINT COATING IAW DO 328 51-93-21. (M)Sep 7, 2002 · N341PH · Dorner DO328100 · Waste Disposal SystemSDR A6WA200230021Channel · corrodedFLOOR CHANNEL UNDER LAVATORY AT FRAME 35 CORRODED BEYOND LIMITS. MAINTENANCE REMOVED DAMAGED FLOOR CHANNEL AT FRAME 35. FABRICATED REPLACEMENT PARTS AND INSTALLED RED DO328 SRM 51-27-0 AND REPAIR PROCEDURE NR HHC-02-327. (M)Sep 7, 2002 · N341PH · Dorner DO328100 · Fuselage Miscellaneous StructureSDR A6WA200230020Rib · crackedRIGHT LEADING EDGE 612CR HAS CRACKED RIB DAMAGE ON 1ST RIB FROM INBOARD AT UPPER SURFACE. MAINTENANCE REMOVED DAMAGED AREA FROM RIGHT WING LEADING EDGE 612CR RIB. FABRICATED REPAIR PARTS REF D0328 DRM 51-27-0 AND INSTALLED REF DO328 SRM 57-41-23 AND DER REPOSep 7, 2002 · N341PH · Dorner DO328100 · Wing, Rib/BulkheadSDR VNAA0209008BrakeDURING TAKE OFF, THE CREW RECEIVED A HIGH BRAKE TEMPERATURE INDICATION AND ABORTED TAKE OFF. THE CREW TAXIED OFF THE RUNWAY AND WAITED FOR THE BRAKE TEMPERATUES TO COOL. THE DECISION WAS THEN MADE TO ATTEMPT ANOTHER TAKE OFF. FLIGHT 4048 THEN DEPARTED WITH Sep 7, 2002 · N328JS · Dorner DO328100 · Landing Gear SystemSDR VNAA0209007Blade · out of adjustDURING CLIMBOUT, THE CREW REPORTED THAT THE LEFT HAND FUEL SHUT OFF VALVE IS CLOSED AND THERE WAS A TORQUE SPLIT OF 5 PERCENT. THE CREW ELECTED TO RETURN TO YOW. THE AIRCRAFT WAS THEN FERRIED TO PIT WHERE MAINTENANCE PERFORMED OPERATIONAL CHECKS ON THE FUEL Sep 5, 2002 · N441JS · Dorner DO328100 · Propeller Blade SectionSDR VNAA0209006Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY LIGHTING AT ROWS 6 TO 9 WILL NOT ILLUMINATE. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASEDSep 5, 2002 · N459PS · Dorner DO328100 · Emergency LightingSDR VNAA0209005Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY LIGHTING AT ROWS 4 TO 5 WILL NOT ILLUMINATE. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASEDSep 5, 2002 · N425JS · Dorner DO328100 · Emergency LightingSDR VNAA0209001Brake Assy · malfunctionedTHE CREW REPORTED THAT THE FIRST OFFICER'S LEFT BRAKE WAS NOT OPERATING AND RETURNED TO THE GATE. MAINTENANCE INSPECTED AND BLED THE BRAKE AND THE BRAKE METERING UNIT IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 32-00-00. OPERATIONAL CHECKS WERE PERFORMED ASep 1, 2002 · N462PS · Dorner DO328100 · BrakeSDR VNAA0208045Battery · dischargedTHE CREW REPORTED THAT THE EMERGENCY LIGHTS AT ROWS 4 AND 5 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 5LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS REAug 30, 2002 · N429JS · Dorner DO328100 · Emergency LightingSDR VNAA0208044Battery · dischargedTHE CREW REPORTED THAT THE LAST TWO EMERGENCY FLOOR TRACK LIGHTS WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 4LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAAug 29, 2002 · N457PS · Dorner DO328100 · Emergency Lighting
Back to Dornier Luftfahrt DO 328-100