Douglas DC-8-62

Service difficulty reports · 2,778

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC862'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA002488Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002487Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE NR 2 FLOOR PLANK CHANNEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH AMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002486Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE CENTER CHANNEL ON THE NR 2 FLOOR PLANK AT STA 800 - 1000 ROW 5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002484Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE FLOOR PANEL TO FLOORBEAM ATTACH FASTENER AT STA 1240 - 1460 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002483Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002482Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 6 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002478Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1460 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002477Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1240 ROW 1 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002476Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 320 - 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-04May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002458Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002457Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 230, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002456Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002455Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 520 - 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002454Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PANEL AT STA 225 - 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002453Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PANEL AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002451Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT FS 225, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002449Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES ON THE FLOOR PLANK AT STA 320 - 600 LT ROW 2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002447Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002445Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002444Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE UPPER AND LOWER SIDE AT STA 660 - 880 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002443Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOOR PANEL ON UNDERSIDE AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002442Floorboard · damagedDURING A MAINTENANCE VISIT FOUND LONGATED HOLES TO THE FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DAMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002441Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE CABIN FLOOR PANEL AT STA 255 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002440Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE CABIN FLOOR PANEL AT STA 215 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002367Floorboard · tool damageDURING A MAINTENANCE VISIT FOUND TOOLING MARKS GOUGED ON FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002360Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 400 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002353Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES IN THE CABIN FLOOR PLANK AT STA 1000 TO 1320 ROW 5 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES AND BLENDED IAMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002296Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002295Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 4-2-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002294Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002206Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT THE UPPER CARGO COMPT FS 1480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR STRAPS IAW EO May 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002650Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1040 RT ROW 8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002641Floorboard · damagedDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1320 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002496Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOORBEAM SPLICE AT STA 740 X+20, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 811May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002490Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT FS 1460 - 1580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002473Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 380 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002471Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 340 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002470Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 320 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002467Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 580 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002464Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 520 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002446Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 420 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002368Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1580 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002366Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 81May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002365Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 0May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002364Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APPROVED 8May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002363Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DAMAGE IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WITMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002362Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1480 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APMay 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002361Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 TO 1500 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES IAW EO NR 00-047 WITH APPROVED 8110May 15, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002349Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH AMay 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002342Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 700, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED May 15, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor Beam
Back to Douglas DC-8-62