Douglas DC-8-62
Service difficulty reports · 2,778
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA002264Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 1420 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 ANSDR RRXA002258Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1360 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-4, 51-1-21 SDR RRXA002228Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1240 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NSDR RRXA002210Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW SDR RRXA002205Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT THE UPPER CARGO COMPT FS 1500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS AND FILLERS IASDR RRXA002202Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1020 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED STRAPS/FILLERS IAW EO NR 00-047 WITH ASDR RRXA002341Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM AT FS 780, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH ASDR RRXA002399Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FASTENER HOLE ON THE LT CHIN SCOOP RAM AIR DUCT SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002395Vane · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED ATTACHMENT HOLES AND T/E OF FLAP SEPARATING AT THE LT FLAP VANE AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW MM 27-51-14.SDR RRXA002388Vane · delaminatedDURING A MAINTENANCE VISIT FOUND ELONGATED AND DELAMINATED HOLES ON THE LEADING OF THE LEFT O/B FLAP VANE NR 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW MM 27-51-14. (CORROSDR RRXA002249Vane · delaminatedDURING A MAINTENANCE VISIT FOUND ELONGATED AND DELAMINATED SCREW HOLES ON THE RIGHT O/B FLAP VANE NR 3 ON THE L/E OF THE VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NR 3 FLAP VANE ISDR RRXA002498Frame · damagedDURING A MAINTENANCE VISIT NEED TO COMPLY WITH MA AM-5310-01:00 EWA FRAME REPAIR AT FS 920 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. C/W MA-AM-5310-01:00 AND RECEIVED AND INSTALLED REPAIR IAAW DC-8 SRM 51SDR RRXA002651Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN THE FLOOR SUPPORT ATTACHED TO FRAME AT STA 380 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110SDR RRXA002412Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 360-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPSDR RRXA002409Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 400-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-20D, 51-1-21 AND EO NR 00-04SDR RRXA002408Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 380-XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-4, 51-1-20D, 51-1-21 AND EO SDR RRXA002324Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A SEVERED FLOORBEAM AT FS 340 AND XCW 52.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH SDR RRXA002298Floor Support · crackedDURING A MAINTENANCE VISIT FOUND CRACKS IN THE FLOOR SUPPORT AT STA 440 BETWEEN L31R TO L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACKS IAW EO NR 00-047 WITH APPROVED 8110-3 DATSDR RRXA002254Link · gougedDURING A MAINTENANCE VISIT FOUND A PORK CHOP GOUGE TO THE LEFT HAND WING O/B FLAP STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RETURNED TO SERVICE IAW EO NR 00-047 WITH APPROVED 8110-3 DATED SDR RRXA0022532Panel · damagedDURING A MAINTENANCE VISIT FOUND HOLES ELONGATED ON THE LT WING T/E LWR HINGED PANEL 577A MOUNT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PANEL IS ACCEPTABLE AND RETURNED TO SERVICE IAW EO NR 00-047 WITH APPSDR RRXA002245Fitting · chafedDURING A MAINTENANCE VISIT FOUND CHAFING AND A GOUGED T/E ON THE RIGHT I/B FLAP CANOE FITTING AT STA 68, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RETURNED TO SERVICE IAW EO NR 00-047 WITH APPROVEDSDR RRXA002203Floorbeam · gougedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER CHORD FLOORBEAM AT STA 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED GOUGES SMOOTH IAW EO NR 00-047 WITH APPROVED 8110-3 DATSDR RRXA002417Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 500 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-SDR RRXA002213Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE, DOUBLE DRILLED HOLES, GOUGES AND MISSING NUT PLATES AT VARIOUS PLACES AT STA 225 TO 330 AND L21L TO L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.SDR RRXA003172Skin · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE NR 2 ENGINE PYLON, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW DC-8 SRM 51-1-20D.SDR RRXA003171Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LONGERON END FITTING AT FS 902 AND L10L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW SRM 51-1-20D, EA PD08-53-048 AND DWG 364585SDR RRXA003170Doubler · damagedDURING A MAINTENANCE VISIT FOUND A TEMP REPAIR ON FUSELAGE AT STA 879 TO 946 AND L5L TO L11L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EA PD08-53-047.SDR RRXA003169Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LONGERON AT FS 935 AND L9L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-2 FIG 1D, 51-1-24 AND 51-1-8 FIG 10.SDR RRXA003167Skin · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE NR 2 ENGINE PYLON, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA003166Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE END FITTING ON THE LONGERON AT FS 902 AND L10L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, EA PD08-53-048 AND DWG 3645859.SDR RRXA003165Doubler · damagedDURING A MAINTENANCE VISIT FOUND A TEMP REPAIR ON FUSELAGE AT STA 879 TO 946 AND L5L TO L11L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW EA PD08-53-047.SDR RRXA003164Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LONGERON 9L AT FS 935, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-2 FIG 1D AND 51-1-24.SDR RRXA002410Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL AT BOTH ENDS AT STA 1300 TO 1320 AND L4L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-21 AND SDR RRXA002652Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON 35L BETWEEN STA 1586 - 1568 LT SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0,SDR RRXA002407Keelbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE KEEL BEAM AT STA 815 - 781 AND L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, 51-1-4, SDR RRXA002402Duct · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED AND BLOWN OUT DE-ICE DUCT ON THE RT CHIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-1-7 ANDSDR RRXA002246Spar · crackedDURING A MAINTENANCE VISIT FOUND A 2 INCH CRACK TO THE LWR AUX SPAR ANGLE IN RADIUS OF THE RIGHT T/E REAR AUX SPAR AT XRS 86, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTSDR RRXA002240Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACKS AT RIVETS ON THE LT WING O/B SLOT LEADING EDGE VANE AT STA XS 472 AND XS 478, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED RIVETS IAW DC-SDR RRXA002238Skin · damagedDURING A MAINTENANCE VISIT FOUND SCREWS PULLING THROUGH SKIN ON THE LT WING O/B SLOT L/E VANE AT STA XFS 428 34 TO 48 INCHES FWD OF SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSDR RRXA002196Fitting · chafedDURING A MAINTENANCE VISIT FOUND CHAFING AT THE RT WING FLAP PORK CHOP FITTING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. ACCEPTABLE TO RETURN TO SERVICE PER EO NR 00-047 WITH APPROVED 8SDR RRXA002397Vane · damagedDURING A MAINTENANCE VISIT FOUND MISALIGNED HOLES ON THE NR 5 FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 4-28-0SDR RRXA002198Vane · misalignedDURING A MAINTENANCE VISIT FOUND A MISALIGNED HOLE FROM OVERHAUL ON THE NR4 MAIN FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SHIMS IAW EO NR 00-047 WITH APPROVED 8SDR RRXA002413Longeron · dentedDURING A MAINTENANCE VISIT FOUND A SMALL DENT AT FS 850 AND L9R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRS IAW DC-8 SRM 51-1-20D, 51-1-21 AND EO NR 00-047 WITH APPRSDR RRXA002469Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 300 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROSDR RRXA002468Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 270 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002423Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 520-XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. WITHIN ALLOWABLE LIMITS IAW DC-8 SRM 53-2-3, FIG 12 AND EO NR 00-047 WITH APPROVEDSDR RRXA002225Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1180 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NSDR RRXA002222Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1120 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SUPPORT IAW EO NR 00-047 WITH APPROVEDSDR RRXA002211Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW SDR RRXA002208Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-0047 WITH APPROV
Back to Douglas DC-8-62