SDR RRXA002439Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1500 - 1560 XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW EO NR 77-995CF DATED 5-22-00 AND ROSEMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002438Seat Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED SEAT TRACK AT FS 1540 - 1560 XCW 22 LT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF DATEDMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002437Seat Track · misdrilledDURING A MAINTENANCE VISIT FOUND ELONGATED AND MISDRILLED HOLES TO THE SEAT TRACK AT FS 1360 - 1430, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002436Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE SEAT TRACK AT FS 1060-XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW EA NR 77-995CF DATED 5-22-00 AND ROSENBAMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002435Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1530 - 1560 XCW 22 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 53-2-0, FIG 12, EA NR 77May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002434Seat Track · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE SEAT TRACK AT FS 1380 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002433Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1300 - 1380 XCW 59.5 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002432Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1260 - 1380 XCW 22 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-3, FIG 12 AMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002431Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 980 - 1125 XCW 57 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 7May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002430Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 1400 - 1440 XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-9May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002429Seat Track · damagedDURING A MAINTENANCE VISIT FOUND GOUGES AND MISDRILLED HOLES IN THE SEAT TRACK AT FS 1220 - 1260, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002428Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 822-849 XCW 57 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW ROSENBALM DWG NR 24300 AND EA NR 77-9May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002427Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 960 - 980 AND XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 53-2-3, FIG 12, 51-1-3May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002426Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 883 - XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW TRACK IAW DC-8 SRM 51-3-0, ROSENBALM DMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002425Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 980 - XCW O, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW ROSENBALM DWG NR 24300 AND EA NR 77-995CF DATED May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002424Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 525 - XCW 22.5 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED TRACK IAW ROSEMBALM DWG NR 24300 AND EO NR 77-995CFMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002422Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 460-XCW 47 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EO NR 77-995CF DATED 5-22-00 ANMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002421Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE SEAT TRACK AT FS 690 - 702, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EA NR 77-995CF, ROSENBALM DWG NR 24May 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002420Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE SEAT TRACK AT FS 440-XCW 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW EA NR 77-995CF, ROSENBALM DRAWING NMay 24, 2000 · N995CF · Doug DC862 · Fuselage, Seat/Cargo Attach FittingsSDR RRXA002358Skin · dentedDURING A MAINTENANCE VISIT FOUND 2 DENTS BEHIND THE JACK PAD AT STA 280 BETWEEN L36L - L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DENTED AREAS IAW DC-8 EO NR 00-047 WITH APPROVED 8110-May 24, 2000 · N995CF · Doug DC862 · Fuselage Main, Plate/SkinSDR RRXA002352Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE FLOOR PLANK AT STA 1240 TO 1460 ROW 10 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8May 24, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002301Floorboard · damagedDURING A MAINTENANCE VISIT FOUND HOLES ELONGATED AND CHAFED UNDERSIDE ON NR 5 FLOOR PANEL 320 - 620 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH AMay 24, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002300Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CRACKED OUT FASTENER HOLES TO THE NR 7 FLOOR PANEL 320 - 620 FLOORBEAM ATTACH POINT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WMay 24, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002233Scoop · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT FWD W/W DRAIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0, 53-2-0 AND EO NR 00-047 WITH APPMay 23, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002354Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED VERTICALLY FROM FLOORBEAM ON THE DOUBLER ON INTERCOSTAL AT STA 670 X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. INSTALLED OVERSIZED FASTENERS AND RMay 22, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002234Scoop · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT DRAIN SCOOP FWD OF MAIN W/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0 AND EO NR 00-047May 22, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXA002243Skin · damagedDURING A MAINTENANCE VISIT FOUND COUNTER SINKS FOR ATTACHMENT FASTENERS EXCEED SRM LIMITATIONS ON THE LEFT O/B LEADING EDGE I/B SEGMENT AT XFS 560 - 710, DAMAGE EXCEEDS LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND May 20, 2000 · N995CF · Doug DC862 · Wing, Plate/SkinSDR RRXA002338Bracket · misinstalledDURING A MAINTENANCE VISIT FOUND IMPROPERLY INSTALLED BRACKETS INSTALLED ON THE LEFT I/B FLAP I/B UPPER FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW VANE IAW EOMay 18, 2000 · N995CF · Doug DC862 · Trailing Edge FlapsSDR RRXA002497Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT ANGLE FR 1320 X+36 Z-8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-89 SRM 51-1-4, 51-1-21 AND 51-1May 17, 2000 · N995CF · Doug DC862 · Fuselage Miscellaneous StructureSDR RRXQA002634Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002649Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN PLANK CHANNEL ON THE NR 4 FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002648Floorboard · damagedDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 3 FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002647Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PLANK AT STA 800 TO 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002646Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE FLOORBEAM TO PLANK ATTACH POINT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-May 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002645Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED ATTACH POINT HOLES ON THE FLOORBEAM AT NR 1 FLOOR PLANK FS 420 TO 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002644Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND LONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NRMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002643Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 320 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002642Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002640Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 230 - 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002638Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 9 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002637Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002636Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002633Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL NR 4 AT STA 235 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002632Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 660 - 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002631Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES ON THE FLOOR PANEL AT STA 860 - 1000 ROW 9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002494Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002493Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 1240 - 1460 ROW 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITHMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002492Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 3 FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002491Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND ELONGATED ATTACH FASTENER HOLES TO THE FLOOR PLANK TO FLOORBEAM ON NR 2 FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002489Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANKS AT FS 860 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor Panel
Back to Douglas DC-8-62