SDR RRXA11124Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA.699-715 AND RBL46, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 53-2SDR RRXA11119Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA.500 AND L33R-L34R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 51-1-2SDR RRXA11118Splice · missingDURING A MAINTENANCE VISIT FOUND MISSING SPLICE FITTING AT STA.1557-1574 AND L36, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-2 FIG#10.SDR RRXA11117Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA.520 AND L33R-L34R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51SDR RRXA11116Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA.560 BETWEEN L31L-L32L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA11115Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AROUND PLUG REPAIR AT STA1420 AND LBL26, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG 12, 51-3-SDR RRXA11114Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO SKIN AT STA.1240 BETWEEN L30R-L27R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-1 FIG#SDR RRXA11113Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO CO-PILOTS AFT RT SEAT TRACK, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA11112Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT PILOTS AFT RT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA11111Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT CO-PILOTS LEFT FWD TRACK, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA11110Seat Track · wornDURING A MAINTENANCE VISIT FOUND WEAR DAMAGE TO SEAT TRACK AT PILOTS AFT LEFT SEAT TRACK, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8 FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA11109Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT CO-PILOTS RT FWD, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA11146Bracket · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E SLOT VANE, INBOARD ATTACH BRACKET AT STA. XOLD6225, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSDR RRXA11132Beam · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FWD ENTRY DOOR INNER SKIN LOWER FLANGE, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0SDR RRXA11131Angle · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO TORQUE BOX ATTACH ANGLE AT STA.375 AND L6L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D AND DWG 2773378.SDR RRXA11130Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO FE'S FWD SEAT TRACK, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0 AND DWG#5888367.SDR RRXA11108Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT 2ND OBSERVERS SEAT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 51-3-0 AND DWG#5888367.SDR RRXA11107Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO L/H SPLICE FITTING AT STA.605-615 AND L31L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-0, 51-1-20D.SDR RRXA11106Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUBE FITTING AT STA.500 AND L33R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-0FSDR RRXA11105Seat Track · brokenDURING A MAINTENANCE VISIT FOUND BROKEN DAMAGE TO SEAT TRACK AT STA.1420-1540 AND LBL26, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-11, SDR RRXA11104Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND MISSDRILLED DAMAGE TO R/H FWD SERVICE DOOR LWR CENTER INTERCOASTAL, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0 FIG#2, 51-1-21, SDR RRXA11103Splice · misdrilledDURING A MAINTENANCE VISIT FOUND MISSDRILLED DAMAGE TO FWD CARGO PIT FRAME AT STA.380 AND L32L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0 FIG 2.SDR RRXA11102Intercostal · damagedDURING A MAINTENANCE VISIT FOUND OPEN HOLE DAMAGE TO FWD ENTRY DOOR INNER SKIN WEB JUST ABOVE WING, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 52-3-2 FIG 3, DSDR RRXA11101Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA.1439-1442 AND LBL46, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 51-SDR RRXA11128Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO B-PIT DOOR FRAME VERTICAL SUPPORT FITTING AT STA.60 AND L27R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLEDSDR RRXA11100Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT STA.717-733 AND LBL60, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FSDR RRXA11099Pan · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FWD CARGO PIT DOOR PAN AT A-PIT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 51-1-21, 52-2-0 FIG 1F.SDR RRXA11098Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FLOORBEAM AT STA.1540 AND RBL44, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AND DHK 996-34S.SDR RRXA11141Pan · corrodedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO C-PIT DOOR PAN (FRAME) TO LWR FWD CORNER AT STA.1120 AND L32R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALSDR RRXA11147Angle · tool damageDURING AS MAINTENANCE VISIT FOUND DRILLED DAMAGE TO ANGLE AND WEB AT STA.350 BETWEEN L19R-L22R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK996-730.SDR RRXA11097Skin · gougedDURING A MAINTENANCE VISIT FOUND GOUGED DAMAGE TO R/H OUTBOARD FLAP UPPER SKIN AT FLAP HINGE 219, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRSDR RRXA11096Fairing · chafedDURING A MAINTENANCE VISIT FOUND CHAFING DAMAGE TO LT HORIZONTAL STAB LOWER FAIRING, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-0 FIG#6 AND DHSK 996-102.SDR RRXA11095Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO B-PIT DOOR FRAME TRIANGLE AT STA.500, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA11094Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUBE FITTING AT STA.940-960 AND L24R. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. NO MATERIAL LOSS NOTED AFTER CLEAN UP, FOUND TO BE WITHIN LIMITS IAW DC-8 SRM 53-2-0 FSDR RRXA11093Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA.525 AND BL=0, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG8A, 51-3-0SDR RRXA11092Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO B-PIT DOOR FRAME FWD BANANNA FITTING AT STA.500 AND L33R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED SDR RRXA11123Skin · chafedDURING A MAINTENANCE VISIT FOUND CHAFFING DAMAGE TO A-PIT DOOR EXTERNAL SKIN ABOVE LOWER NR 6 LATCH HOOK, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0 FIG2.SDR RRXA11122Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA.520 AND L31L-L32L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53SDR RRXA11121Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE BATHTUB FITTING AT STA. 520 AND L30L-L29L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2SDR RRXA11120Fitting · corrodedDURING A MAINTENACE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA.520 AND L34L-L33L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-SDR RRXA11090Doubler · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO MAIN CARGO DOOR CUT OUT AFT FRAME SEAL AT 18 INCHES FROM UPPER END, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0SDR RRXA11089Web · damagedDURING A MAINTENANCE VISIT FOUND 8EA OPEN HOLES AND DRILL BIT DAMAGE TO INTERNAL FRAME AT STA340 AND L11L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 52-2-0 FIG#2 AND 51SDR RRXA11088Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LONGERON END FITTING AT STA 1530-1540 AND L30R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D, DWG#464132SDR RRXA11087Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR BEAM AT STA. 1540 AND LBL26, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DHMSK996-554.SDR RRXA11086Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO END FITTING AT STA.1540 AND L34R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D AND DWSDR RRXA11085Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACKED DAMAGE TO END FITTING AT STA 1530-1540 AND L36, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D SDR RRXA11084Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO AFT LONGERON END FITTING AT STA. 1530 AND L28L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D.SDR RRXA11083Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO SEAT TRACK SCALLOPS AT STA. 1330 AND RBL26, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-7-3SDR RRXA11082Skin · scratchedDURING A MAINTENANCE VISIT FOUND SCRATCH DAMAGE TO EXTERIOR FUSELAGE SKIN AT STA. 410 AND L11R. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. BURNISHED SCRATCH IAW DC-8 SRM 53-2-0 FIG1F, NDT INSPECTED AND FOUND TO BE WITHIN LIMITS IAW DC-8 SRM 53-1-0.SDR RRXA11081Skin · nickedDURING A MAINTENANCE VISIT FOUND NICK DAMAGE TO FWD CARGO PIT CROOS SLIDE DOOR JAMB AFT CUT OUT EDGE OF EXT. AT STA 560 AND L26R-L31R. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. BLENDED AND FOUND TO BE WITHIN LIMITS IAW DC-8
Back to Douglas DC-8-62F