SDR RRXA991237Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1160 AND STA 1270 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991236Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1000 AND STA 1160 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLERS IAW DC8 SRM 51-1-8 PG 16SDR RRXA991235Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1460 AND STA 1500 AT BL 26 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER SDR RRXA991234Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1270 AND STA 1300 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991233Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 1360 AND STA 1420 AT BL 22 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991232Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1360 AND STA 1440 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991231Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 700 AT BL 28 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991230Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 760 AND STA 800 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM SDR RRXA991229Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 740 AT BL 6 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM 5SDR RRXA991228Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 420 AND STA 520 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991227Ffloorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 700 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991242Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE,CABIN FLOOR PLANK BETWEEN STA 1240 AND STA 1280 AT BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLESDR RRXA991241Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK AT STA 1220 AND BL 18 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PGS 39/4SDR RRXA991240Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1120 AND 1140 AT BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 FISDR RRXA991239Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1040 AND STA 1060 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991238Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION , FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1100 AND STA 1120 AT BL 32 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991251Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 700 AND STA 822 AT BL 49 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991250Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 460 AND STA 540 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991249Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 900 AND STA 920 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991248Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 700 BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR FILLER AND ANGLE IAW DC8 SRM 51-1-8 PG 16SDR RRXA991247Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC8 SRM 53-2-3 FIG 10 PSDR RRXA991246Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991245Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1400, BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 52-2-3 PGS 39/40 FIGSDR RRXA991244Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 880, BL 38 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGS 39/SDR RRXA991243Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 717 AND STA 759 AT BL 36 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991189Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, WEB, CABIN RT TOP OF LOWER CARGO DOOR BETWEEN STA 480 AND STA 520 AT BL 53 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DSDR RRXA991255Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 620 AT BL 8 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51SDR RRXA991254Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 660 AND STA 680 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991253Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 840, BL 4 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PG 16 AND 53-2-SDR RRXA991252Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 800, BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGSSDR RRXA991256Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 879 AT BL 13 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51SDR RRXA991257Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP W/W AT STA 980, BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-8 PG SDR RRXA991258Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOORBEAM AT STA 580, BL 45 RIGHT, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER ANGLE IAW FAA APPROVED JOSSAIR, COSDR RRXA991185Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE,FUSELAGE SKIN BETWEEN STA 1118 AND STA 1165 BETWEEN LONGERONS 32 RIGHT AND LONGERON 34 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DCSDR RRXA991184Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CENTER TANK AFT TOP SKIN PANEL AT STA 857, BL 46 RIGHT, 2 FORWARD OF REAR SPAR. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUSDR RRXA991183Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN TOP OF W/W UNDER FLOOR BETWEEN STA 902 AND STA 920 AT BL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW EAF-MSDR RRXA991263Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 330 AND STA 520 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM 5SDR RRXA991262Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1500 AND STA 1520 AT BL 42 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMSDR RRXA991260Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 360 AND STA 520 AT BL 54 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991259Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 360 AND STA 520 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 51-1-8 PGSDR RRXA991182Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP OF MLG W/W AT STA 980, BL 45 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 53-SDR RRXA991181Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP OF MLG W/W BETWEEN STA 879 TO STA 902 AT BL 69 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPASDR RRXA991180Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP OF MLG W/W BETWEEN STA 857 AND STA 879 AT BL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUSDR RRXA991223Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1300 AND STA 1430 AT BL 4 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRMSDR RRXA991266Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 380 AND STA 580 AT BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991265Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 640 AT BL 35 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991264Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 380, BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53SDR RRXA991178Floor Beam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, TOP SIDE OF PRESSURE WEB AND FLOOR BEAM JOINT AT STA 920, BL 67 RIGHT.. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAWSDR RRXA991177Floor Beam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, TOP SIDE OF PRESSURE WEB AND FLOOR BEAM JOINT AT STA 940, BL 67 RIGHT.. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAWSDR RRXA991271Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 280, BL 36 RIGHT AND WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW D
Back to Douglas DC-8-62F