Douglas DC-8-62F
Service difficulty reports · 1,163
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA991270Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK BETWEEN STA 300 AND STA 360 AT BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION OF SEAT TRACK AND SDR RRXA991269Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 700, BL 28 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND NEW SECTION OF FLOOR PANEL ISDR RRXA991268Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 670, BL 49 RIGHT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10.SDR RRXA991267Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 320 AT BL 54 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991203Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 730 AND BL 54 RIGHT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PAGESDR RRXA991275Floor Board · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOORBOARD, 1-1/2 AT STA 1520, BL 22 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGS 3SDR RRXA991274Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 690 AND STA 710 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991273Floor Panel · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 640 AND STA 660 AT BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM SDR RRXA991272Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 538 AND STA 548 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991474Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, SKIN, FWD CARGO COMPARTMENT AT STA 440, BETWEEN LONGERONS 35 LEFT AND 33 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER RSDR RRXA991476Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, MAIN CARGO DOOR PLANK BETWEEN STA 640 AND STA 700, AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. BI REPAIR DOUBLER IAW DC8 SRM 53-2-3, FIG 10. (CSDR RRXA991207Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1480 AND BL 34 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/40 FIG 1SDR RRXA991206Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1420 AND STA 1460 AT BL 6 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PSDR RRXA991205Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 880, BL 35 RIGHT AND WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/40SDR RRXA991204Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 640 AND BL 28 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PG 1, 53-2SDR RRXA991202Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 730 AND STA 760 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991201Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 717 AND STA 730 AT BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABARICATED AND INSTALLED DOUBLER IAW DC8 SRM 52-2-3 SDR RRXA991200Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANT AT STA 720 AND BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGSSDR RRXA991199Floorbeam · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 640 AND STA 720 AT BL 36 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51SDR RRXA991197Floorbeam · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 540 AND BL 42 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/4SDR RRXA991196Floorbeam · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 560 AND BL 56 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PAGES 30/4SDR RRXA991195Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 500 AND BL 42 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/4SDR RRXA991194Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 320 AND BL 54 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM 1-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PAGES 39/40. (CORROSION DAMAGE RECORDED IN EWA CSDR RRXA991193Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 330 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAWSDR RRXA991192Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 300 AT BL 4 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-SDR RRXA991191Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 300 AT BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991190Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 260 AND STA 300 AT BL 20 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5SDR RRXA991188Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, LONGERON NR 34 RIGHT, FWD CARGO COMPARTMENT FROM STA 500 TO STA 520. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED LONGERON SECTION IAW SDR RRXA991179Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, RT FUSELAGE SKIN AT STA 270 AND LONGERON 30 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-3-2 AND 5SDR RRXA991376Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, VERTICAL STABILIZER, RT SIDE ATTACH ANGLE BRACKET STRIP AT STA 1542, LONGERON 2 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE SECSDR RRXA991370Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 1420, BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SECTION AND SPLICE REPAIR IAW DC8 SRM 53-2-3 FIGSDR RRXA991369Seat Track · corrosionDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 1080, BL 45 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SECTION EXTRUSION AND SPLICES IAW DC8 SRM 53-2-SDR RRXA991222Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR TRACK AT STA 600, BL 59 LEFT AND WL O. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK SECTION IAW DC8 SRM 53-2-3 PSDR RRXA991221Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR TRACK AT STA 1000, BL 59 LEFT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK SECTION AND SPLICES IAW DC8 SRMSDR RRXA991220Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR TRACK BETWEEN STA 600 AND STA 690 AT BL 45 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION OF TRACK IAW DC8 SDR RRXA991218Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR TRACK AT STA 600, BL 0, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION IAW DC8 SRM 53-2-3 FIG 1SDR RRXA991217Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR TRACK BETWEEN STA 780 AND STA 840 AT BL 59 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION TRACK AND SPLICESDR RRXA991216Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, CABIN FLOOR TRACK AT STA 1000, BETWEEN BL 45 LEFT AND 49 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK SECTION AND SPLISDR RRXA991215Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 740 AND BL 49 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 51-1-8 AND 53-2-3 FIG 10SDR RRXA991214Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR TRACK BETWEEN STA 880 AND STA 920 AT BL 45 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION OF SEAT TRACK IASDR RRXA991213Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 980 AND BL 45 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SECTION OF SEAT TRACK IAW DC8 SRM 53-2-3 PSDR RRXA991212Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 1230 AND BL 59 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK SECTION AND SPLICES IAW DC8 SRM 53-SDR RRXA991211Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN SEAT TRACK AT STA 1100 AND BL 59 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK AND SPLICES IAW DC8 SRM 53-2-3 PGS SDR RRXA991210Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1300 AND STA 1340 AT BL 6 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC8 SRM 53-2-3 PASDR RRXA991209Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1340 AND BL 12 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/40 FIG SDR RRXA991208Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1360 AND BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 PAGES 39/4SDR RRXA991371Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 1480, BL 38 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-0 PGS 2P FIG 1SDR RRXA991372Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, WING, SKIN, LT O/B FLAP I/B BETWEEN STA XRS 178 AND XRS 217. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SKIN IAW DC8 SRM 57-7-1. (CORROSIOSDR RRXA991375Bulkhead · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BULKHEAD, ON FWD BULKHEAD, IN R/MLG W/W AT STA 870, BL 30 RIGHT, WL 10 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REAR SPAR TOSDR RRXA991374Bulkhead · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BULKHEAD, RT MLG W/W PRESSURE DECK, BL 48 RIGHT, STA 874, 4 AFT OF FWD BULKHEAD STA 870. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED D
Back to Douglas DC-8-62F