Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IXX2008F00103Skin · dentedDURING ROUTINE C-CHECK INSP, FOUND RT WING INBD L/E UPPER SKIN DENTED AT STA SFS 120.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN, DOUBLER, ANGLES, FILLER, AND FAIRING. PERFORMED HEAT TREATMENT TO REPAIR ANGSDR IXX2008F00102Skin · misrepairedDURING ROUTINE C-CHECK, FOUND LWR FWD FUSELAGE BELLY AFT OF FWD BASKET DOOR HAS IMPROPER REPAIR AT STA FS403, LONGERON 35.5 LT. REMOVED FASTNERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR DOUBLER. REMOVED DAMAGED AREA. FABRICATED NEW SKIN, REPAIRSDR IXX2008F00100Skin · misrepairedDURING ROUTINE C-CHECK INSPECTION, FOUND LT FWD FUSELAGE AFT AND BELOW EMERGENCY EXIT DOOR HAS IMPROPER REPAIR AT FS 447 LOGN 25.5 LT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN, EXTERNAL SDR IXX2008F00099Skin · misrepairedDURING ROUTINE C-CHECK INSPECTION, FOUND AFT LOWER FUSELAGE AFT AND BELOW L-2 AND R-2 DOORS HAS IMPROPER REPAIR AT STA FS 1695, LONGERON 36. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN. REPASDR UPS08853152Floor Panel · gougedINSPECTION TYPE:C1 FLOOR PANEL FROM STA 660 TO STA 760 RBL 24 TO 44 HAS 14 INCH GOUGE PENETRATING OUTER SKIN. FABRICATED AND REPLACED FLOOR PANEL IAW EO DC8-5320-9691C.SDR UPS08852997Line · leakingCREW LOST HYDRAULIC QTY AND PRESSURE. AFTER TOP OF CLIMB, CREW DECLARED AN EMERGENCY. LANDED SAFELY AND A/C WAS TOWED TO GATE. FOUND HYD LINE FOR BOGIE TRIM CYL LOCATED ON REAR SIDE OF THE LT LANDING GEAR, LEAKING. REMOVED AND RE-INSTALLED A FLEX LINE AS NEESDR UPS08853194Stringer · crackedINSPECTION TYPE:C1 FOUND CRACK ON STRINGER 53 AT O/B DRAG ANGLE NR 4 ALT. REMOVED AND REPLACED STRINGER IAW SRM 51-1-8, 57-2-2 FIG 3D, 57-4-0 FIG 11.SDR UPS08853149Fitting · crackedINSPECTION TYPE:C1 NR 4 ALT Z-FITTING CRACKED. REMOVED CRACKED FITTING IAW SRM 51-01-20D. FABRICATED AND INSTALLED REPLACEMENT FITTING IAW DWG 3644046, SRM 51-01-24, AND 51-01-20D.SDR UPS08853131Fitting · crackedINSPECTION TYPE:C1 NR 1 ALT Z-FITTING IS CRACKED. REMOVED Z-FITTING IAW SRM 51-01-20D. FABRICATED AND INSTALLED REPLACEMENT FITTING IAW DWG 364046, SRM 51-01-20D.SDR IXX2008F00107Seat Track · damagedDURING ROUTINE C-CHECK INSPECTION, FOUND P-1-5 SEAT TRACK DAMAGED. REMOVED DAMAGED TRACK SEGMENT. FABRICATED SPLICES. CLEANED, TREATED, AND PRIMED AREA AND SPLICES. INSTALLED NEW TRACK SEGMENT AND SPLICES IAW SRM 53-7-1, FIG 4, SHEET 1 ITEM C, SRM 51-2-0, SDR IXX2008F00106Skin · misrepairedDURING ROUTINE C-CHECK, FOUND FWD OF FLAT AFT PRESSURE BULKHEAD HAS IMPROPER REAPIR AT LONGERON 28. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR DOUBLERS. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. NO CRACK, NO CORROSION. FSDR UPS08853230Stringer · crackedINSPECTION TYPE:C1, NR 4 ALT THRU 505B, STRINGER 54 CRACKED AT APPROX XRS 490. FABRICATED AND INSTALLED 2 REPAIR SPLICES IAW SAA EA 088-5710-01-1474.SDR UPS08853132Attach Fitting · corrodedINSPECTION TYPE:C1 B-PIT STA 520 LONGERON 21R FLOORBEAM ATTACH FITTING HAS CORROSION. REMOVED FITTING IAW SRM 51-01-20D. INSTALLED REPLACEMENT FITTING IAW SRM 51-01-20D, AND 51-03-00.SDR UPS08853128Intercostal · crackedINSPECTION TYPE:C1 CRACKED CHANNEL AND GOUGED INTERCOSTAL AT THE SAME LOCATION ON RT FWD SERVICE DOOR LOWER AFT CORNER. REMOVED EDGE CRACK ON CHANNEL BY BLENDING IAW SRM 53-02-00. FABRICATED AND REPLACED INTERCOSTAL IAW DWG 5615762 SRM 51-01-21, AND 51-01-20SDR UPS08853089Floor Panel · damagedINSPECTION TYPE:C1 MAIN CABIN FLOORBOARD AT STA 880-1000 LBL 44.60 HAS 3EA MISSING & 1 EA DAMAGED INSERT. REPLACED 4EA INSERTS IAW DPS 1.9023 REPAIR 4.3-1 PAGE 4.SDR UPS08853088Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN FLOORBOARD AT STA 680-780 RBL 44.60 HAS 2 EA CRUSHED AREAS. FABRICATED REPLACEMENT FLOOR PANEL IAW EO DC8-5320-9691.SDR UPS08853083Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN FLOORBOARD AT STA 680-780 LBL 25.44 IS CRUSHED AT FWD & AFT ENDS. FABRICATED REPLACEMENT FLOOR PANEL IAW EO DC8-5320-9691.SDR UPS08853081Doubler · gougedINSPECTION TYPE:C1 RT WING O/B FLAP STA XF 228 HAS A ROUND DOUBLER GOUGED AT UPPER SKIN, NEXT TO L/E AREA. REMOVED EXISTING DOUBLER IAW SRM 51-1-21A. FABRICATED AND INSTALLED REPLACEMENT REPAIR DOUBLER IAW SRM 57-07-01 FIG 004, 57-02-0 FIG 002A, AND SRM 51-1SDR UPS08853070Door Frame · crackedINSPECTION TYPE:C1 CRACKED FWD JAMB JUST ABOVE UPPER HINGE ON RT FWD SERVICE DOOR. BLENDED EDGE REMOVING CRACK IAW SRM 53-02-00, AND 51-01-08.SDR UPS08853069Floorboard · damagedINSPECTION TYPE:C1 MAIN CABIN FLOORBOARD AT STA 800-1000 RBL 25.44 HAS 1 EA MISSING & 3EA DAMAGED INSERTS. REMOVED AND REPLACED 4EA INSERTS PER B DPS 1902-3 REPAIR 4.3.1 PG 4.SDR UPS08853067Floorboard · crackedINSPECTION TYPE:C1 COURIER AREA FLOORBOARDS 2EA ARE DELAMINATED AND CRACKING. SANDED, CLEANED AND REPAIRED 2EA COURIER AREA FLOORBOARDS AT DELAMINATED AND CRACKED AREAS IAW SRM 51-01-19.SDR UPS08853049Intercostal · crackedINSPECTION TYPE-C1, FWD LOWER CARGO COMP FLOOR SUPPORT BRACKET CRACKED AT FUS STA 80 LONGERON 36 AS MARKED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL (BRACKET) IAW SRM 51-01-20D,DWG 4619078, AND SRM 51-03-01.SDR UPS08853047Doubler · corrodedINSPECTION TYPE-C1, CORROSION ON A DOUBLER INSIDE RT FWD SERVICE DOOR FWD TORQUE BOX JUST BELOW LOWER HINGE. REMOVED AND REPLACED FITTING (DOUBLER) SRM 51-01-20D,51-03-00.SDR UPS08852993Skin · gougedINSPECTION TYPE:C1, RT WING OB FLAP STA XF 228 HAS EXISTING REPAIR DOUBLER GOUGED AT UPPER FLAP SKIN, NEXT TO AFT FIXED PANEL OF FLAP HINGE COVER REMOVED EXISTING DOUBLER FABRICATED AND REPLACED REPAIR DOUBLER IAW SR M 51-1-21A, 57-2-8 FIG 2A,57-7-01 FIG 4SDR IPXA09855161Door Frame · damagedINSPECTION TYPE:C1 A HOLE DRILLED THROUGH AFT DOOR JAMB ON LT CTR SERVICE DOOR. STOP DRILLED DAMAGE AREA, FABRICATED AND INSTALLED REPAIR ANGLE DOUBLER IAW DC-8 SRM 52-03-01-0 FIG 3.SDR UPS08853157Skin · wornINSPECTION TYPE:C1 2 WORN AREAS EITHER SIDE OF O/B FLAP STA 340 LT FLAP. FABRICATED AND INSTALLED REPAIR DOUBLER ON O/B SIDE OF STA 340 IAW SRM 57-07-01 AND 51,1-21A.SDR UPS08853129Angle · damagedINSPECTION TYPE:C1 MAIN CABIN SUBFLOOR "L" ANGLE CUTOFF THROUGH BOLT HOLE RADIUS BOLT INSTALLED (HALF ON AND HALF OFF CUT) STA 857 RBL 23, AT BOTTOM OF PRESSURE PNL. REMOVED AND REPLACED "L" ANGLE IAW SRM 51-1-24, 51-3-0, 51-1-20D, 51-1-21.SDR UPS08853090Floorbeam · crackedINSPECTION TYPE:C1 D PIT STA 1360 LONGERON 31R FLOORBOARD SUPPORT CRACKED. REPAIRED FLOORBOARD SUPPORT AT STA 1360 L31R IAW EO DC8-5320-6176.SDR UPS08853078Fitting · corrodedINSPECTION TYPE:C1 C PIT STA 1275, LONGERON 36, FITTING HAS CORROSION. CORROSION ON FITTING OUT OF LIMITS IAW SRM 53-2-0 FIG 1F. REMOVED FITTING IAW SRM 51-1020D, REPLACED FITTING IAW 51-01-24, 51-01-20D, AND 51-03-01.SDR UPS08853071Skin · gougedINSPECTION TYPE:C1 RT WING NR 3 SPOILER HAS TWO DEEP GOUGES AT LOWER SKIN AREA. REMOVED DAMAGE IAW SRM 51-01-09A. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW SRM 57-07-01 AND 51-01-09A.SDR UPS08853068Intercostal · damagedINSPECTION TYPE:C1 A HOLE DRILLED THROUGH INTERCOSTAL ON RT CTR SERVICE DOOR STRUCTURE 10, 10 INCHES BELOW UPPER HINGE. REMOVED DAMAGED INTERCOSTAL, FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 51-01-21, DWG 5615762, AND SRM 51-03-00, 51-1-20.SDR UPS08853048Fitting · gougedINSPECTION TYPE-C1, D PIT STA 1345 LONGERON 28L, LONGERON FITTING GOUGED AT RADIUS. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D,51-3-2.SDR UPS08853004Intercostal · damagedINSPECTION TYPE-C1, TWO MOUNT TABS SHEARED THRU ATTACH RIVETS FOR INTERCOSTAL IN COCKPIT SUBFLOOR STA 8 TO -12 BL 0. FABRICATED AND INSTALLED 2EA REPAIR DOUBLER IAW SRM 53-02-00 FIG 1B 51-1-21.SDR UPS08852994Structure · damagedINSPECTION TYPE:C1, TWO HOLES IN LT FLAP EITHER SIDE OF FLAP STATION 219 BACKSIDE OF FLAP. CUT OUT DAMAGE, FABRICATED AND INSTALLED 2EA REPAIR DOUBLERS IAW SRM 5 7-02-01 FIG 2Q,51-01-09, AND 51-01-21ASDR UPS08852949Skin · gougedINSPECTION TYPE-C1 GOUGE ON INNER SKIN OF RT CTR SERVICE DOOR JUST ABOVE BAYONET. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 52-03-00 AND 51-01-21- 0 FIG 033.SDR UPS08852946Seat Track · damagedINSPECTION TYPE-C1 MAIN CABIN, SEAT TRACK PLUG DAMAGED AND ATTACH SCREWS (2EA) TOO HIGH-S TA. 240 LBL 45. REMOVED AND REPLACED PLUG AT MAIN CABIN SEAT TRACK STA 240 LBL 45 IAW SRM 51-3-00 PG1.SDR UPS08853234Frame · damagedINSPECTION TYPE:C1 MAIN CABIN DOUBLE DRILLED HOLE IN BELTFRAME STA 781L-15R. FABBED AND INSTALLED REPAIR DOUBLER IAW SRM 51-1-8, 53-2-0.SDR UPS08853228Frame · damagedINSPECTION TYPE:C1 MAIN CABIN, DOUBLE DRILLED HOLE IN BELTFRAME STA 781 L15R. FABBED AND INSTALLED REPAIR DOUBLER IAW SRM 51-1-8, 53-2-0 FIG 1B.SDR UPS08853134Pressure Panel · crackedINSPECTION TYPE:C1 PRESSURE WEB CRACKED AROUND RIVET HEAD, RT NOSE A/C TUNNEL CEILING STA -54, RBL 35. REPAIRED CRACK PER SAA EA 008-5330-01-A1489.SDR UPS08853006Door Frame · damagedINSPECTION TYPE-C1, MAIN CARGO DOOR UPPER FRAME CENTER DOOR JAM HAS A DOUBLE DRILLED HOLE AT STA 220 & 6L. CUTOUT DAMAGE IAW SRM 53-02-00, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-02-00,51-1-20D, AND 51-1-21.SDR UPS08852996Fitting · crackedINSPECTION TYPE-C1, MAIN CABIN, FUSELAGE SPLICE FITTING CRACKED STA 680 L-6R. REMOVED AND REPLACED FITTING IAW SRM 51-03-01.SDR UPS08853155Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN, FLOOR PNL HAS CRUSHED HONEYCOMB STA 1120 RBL 14. FABRICATED AND REPLACED FLOOR PNL IAW EO DC8-5320-9691C.SDR UPS08853086Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN, FLOOR PANEL HAS CRUSHED HONEYCOMB STA 1180 RBL 14. REMOVED FLOOR PANEL IAW MM 53-21-02, FABRICATED AND INSTALLED REPLACEMENT PANEL IAW EO DC8-5320-9691C, AND MM 53-21-02.SDR UPS08853080Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN FLOOR PANEL HAS CRUSHED HONEYCOMB STA 1490 RBL 57. REMOVED FLOOR PANEL, FABRICATED AND INSTALLED REPLACEMENT PANEL IAW MM 53-21-02, EO DC8-5320-9691.SDR UPS08853079Floor Panel · puncturedINSPECTION TYPE:C1 MAIN CABIN, FLOOR PANEL PUNCTURED STA 1220 RBL 58. REMOVED FLOOR PANEL IAW MM 53-21-02, REPAIRED PER SRM 51-01-19, REINSTALLED PANEL IAW 53-21-02.SDR UPS08853077Floor Panel · crushedINSPECTION TYPE:C1 MAIN CABIN, FLOOR PANEL HAS CRUSHED HONEYCOMB STA 1490 RBL 36. REMOVED PANEL, FABRICATED AND INSTALLED REPLACEMENT FLOOR PANEL IAW MM 53-21-02, AND EO DC8-5320-9691C.SDR UPS08853076Floor Panel · damagedINSPECTION TYPE:C1 MAIN CABIN, FLOOR PNL HAS CRUSHED HONEYCOMB STA 1500 LBL 29. REMOVED PNL, FABRICATED AND INSTALLED REPLACEMENT FLOOR PNL IAW MM 53-21-02, EO DC8-5320-9691C.SDR UPS08853013Longeron · crackedINSPECTION TYPE-C1, MAIN CABIN, L16L CRACKED AT BS 1746 CANT FRAME, FABRICATED AND INSTALLED REPLACEMENT LONGERON SECTION IAW SRM 53-02-02 FIG 10,51-01-20D,51-03-01.SDR UPS08853133Torque Box · crackedINSPECTION TYPE:C1 A FITTING CRACKED IN LEFT FWD EMERGENCY EXIT DOOR FWD JAMB TORQUE BOX STA 380 L19L. FABRICATED AND INSTALLED REPAIR FITTING IAW SAA EA 008-5310-01-A1486-1.SDR UPS08853014Longeron · crackedINSPECTION TYPE-C1, L14R CRACKED IN LOWER RADIUS AT BS 1754 APPROX (SEEN IN BACKSIDE OF LONGERON) AT LONGERON SPLICE IN MAIN CABIN. FABRICATED AND INSTALLED REPLACEMENT LONGERON SECTION IAW SRM 53-02-02 FIG10, 53-05-03, 51-01-20D, AND 51-03-01.
Back to Douglas DC-8-71F