Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS00831575Fitting · crackedINSPECTION TYPE:C123 STA 940 LONGERON 19R INTERCOSTAL TO FRAME FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779874, AND SRM 51-1-20D.SDR UPS00831562Fitting · crackedINSPECTION TYPE:C123, STA 960 LONG 19R INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779874 AND SRM 51-1-20D.SDR UPS00831561Fitting · crackedINSPECTION TYPE:C123, STA 742 LONG 11L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4750418 AND SRM 51-1-20D.SDR UPS00831560Fitting · crackedINSPECTION TYPE:C123, STA 857 LONG 20L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779979 AND SRM 51-1-20D.SDR UPS00831557Fitting · crackedINSPECTION TYPE:C123, STA 1180 LONG 17R INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4750419 AND SRM 51-1-20D.SDR UPS00831556Fitting · crackedINSPECTION TYPE:C123, STA 759 LONG 18R INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779874 AND SRM 51-1-20D.SDR UPS00831555Fitting · crackedINSPECTION TYPE:C123, STA 857 LONG 13R INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750025 AND SRM 51-1-20D.SDR UPS00831553Fitting · crackedINSPECTION TYPE:C123, STA 660-680 LONG 11R END FITTING CRACKED. REMOVED AND REPLACED FITTING IAW DWG 5750540, SRM 51-1-21, 51-1-20D.SDR UPS00831549Fitting · crackedINSPECTION TYPE:C123, STA 220 LONG 11R SPLICE FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 5644985 AND SRM 51-1-20D.SDR UPS00831547Fitting · crackedINSPECTION TYPE:C123, STA 1040 LONG 19L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779978 AND SRM 51-1-20D.SDR UPS00831546Fitting · crackedINSPECTION TYPE:C123, STA 1020 LONG 20L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779978 AND SRM 51-1-20D.SDR UPS00831544Fitting · crackedINSPECTION TYPE:C123, STA 920 LONG 20L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779874 AND SRM 51-1-20D.SDR UPS00831540Fitting · crackedINSPECTION TYPE:C123, STA 1020 LONG 20L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779978, AND SRM 51-1-20D.SDR UPS00831539Fitting · crackedINSPECTION TYPE:C123, STA 902 LONG 20L INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750025 AND SRM 51-1-20D.SDR UPS00831526Rib · crackedINSPECTION TYPE:C123, LEFT WING L/E UPPER RIB CRACKED AT XILD.7095. REPAIRED IAW SRM 57-2-0 FIG 2.SDR UPS00831525Rib · crackedINSPECTION TYPE:C123 LEFT WING L/E. UPPER RIB CRACKED AT XS227.335 REPAIRED I.A.W. SRM 57-2-0 FIG. 2SDR UPS00831524Rib · crackedINSPECTION TYPE:C123, RIGHT WING L/E AT STA XS 250.089 UPPER RIB WAS CRACKED. REPAIRED PER SRM 57-2-0 FIG 2.SDR UPS00831521Fitting · crackedINSPECTION TYPE:C123, STA 1180 LONG 20R INTERCOSTAL TO FRAME FITTING WAS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4750418 AND SRM 51-1-20D.SDR UPS00831590Seat Track · corrodedINSPECTION TYPE:C123 CABIN STA 960 SEAT TRACK PLANK AT RBL 48 CORRODED THROUGH. CUTOUT DAMAGED SECTION OF SEAT TRACK IAW DC8 SRM 53-2-3. FABRICATED SPLICES IAW DC8 53-2-3. TRIMMED NEW SECTION OF SEAT TRACK IAW DC8 SRM 53-2-3. ALODINED AND PRIMED IAW DC8 SRSDR UPS00831730Frame · crackedINSPECTION TYPE:C123, LEFT AFT ENTRY DOOR HAD A CRACKED FRAME. REPAIRED IAW SRM 52-2-0 FIG 2.SDR UPS00831551Splice · crackedINSPECTION TYPE:C123, STA 660 FRAME SPLICE WAS CRACKED BETWEEN LONG 21R TO 22R. REMOVED AND REPLACED FRAME SPLICE IAW DWG 5646688 AND SRM 51-1- 20D, 53-4-0 FIG 30.SDR UPS00831661Frame · corrodedINSPECTION TYPE:C1 STA 1380 FRAME LOWER FLANGE CORRODED BEYOND LIMITS AT LONGERON 33L. REPAIRED IAW DC8-53A-010, AND DC8-5310-11728-A.SDR UPS00831659Frame · corrodedINSPECTION TYPE:C1 STA 1040 FRAME UPPER FLANGE AT LONGERON 31L IS CORRODED BEYOND LIMITS. REPAIRED IAW SRM. ADDENDUM DC8-5310-11728-A.SDR UPS00831586Frame · corrodedINSPECTION TYPE:C1 STA 280 FRAME HAS HEAVY CORROSION BETWEEN 35L TO 35R UNDER FLANGE. REPAIRED IAW SRM 53-2-0 FIG 23.SDR UPS00831462Seat Track · corrodedINSPECTION TYPE:C1, STA 1380 RBL 24 SEAT TRACK CORRODED BEYOND LIMITS. REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 8A.SDR UPS00831461Seat Track · corrodedINSPECTION TYPE:C1, STA 1380 RBL 24 SEAT TRACK CORRODED BEYOND LIMITS. REMOVED AND REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 8A, 51-3-0.SDR RRXA000431Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SHEAR TIE FITTING FWD BAGGAGE AT STA 420 AND LONGERON 35L - 36L. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGED FITTING, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLED IAW DC8 SRMSDR RRXA000430Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FWD BAGGAGE AT STA 340 AND LONGERON 32, 33, & 34. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED FITTINGS IAW DC8 SRM 53-2-0 AND 53-1-02 FIG 1F. TREATED AREA IAW DC8 SRM 51-1-8. CORROSIONSDR UPS00831738Fitting · crackedINSPECTION TYPE:C123, AT RT WHEEL WELL, WING TO FVS FAIRING, VERTICAL SUPPORT FITTING CRACKED. FOR FABRICATION OF NEW VERTICAL SUPPORT FITTING SEE TIMCO PRINTED OP ERATION 50017. LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1-24. INSTALLED NEW FITTING IAWSDR UPS00831658Fitting · corrodedINSPECTION TYPE:C1 STA 1160 LONGERON 34L BATH TUB FITTING IS CORRODED BEYOND LIMITS. REMOVED AND REPLACED FITTING IAW DWG 3755845, AND SRM 51-1-20D.SDR UPS00831574Rib · damagedINSPECTION TYPE:C1 RIGHT WING L/E RIB AT XW 257.5 IS DAMAGED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED RIB IAW DWG 5769517, AND SRM 51-1-20D.SDR RRXA000450Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT CARGO COMP RIB AT STA 1120 AND LONGERON 34L - 32R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLED IAW DC8 SRM 53-20 AND EAPD08-5SDR UPS00831741Seat Track · corrodedINSPECTION TYPE:C123, MAIN CABIN SEAT TRACK 'F' STA 1440-1540 HAD CORROSION ON BOTTOM. REMOVED FLOORBOARD SEAT TRACK. DRILLED SEAT TRACK AND SPLICES IAW DC8 SRM 53-2-3. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED SEAT TRACK, SPLICES AND FLOORBOARD IAWSDR UPS00831655Longeron · corrodedINSPECTION TYPE:C1 STA 1020 AND 1040 LONGERON 31L ATTACHMENT FLANGES ARE CORRODED BEYOND LIMITS. REPAIRED IAW 8110-3 APPROVED DH SK 703-287.SDR UPS00831620Floor Beam · corrodedINSPECTION TYPE:C1 STA 80 RBL 50 UPPER AFT FLOOR BEAM FLANGE IS CORRODED BEYOND LIMITS. REPAIRED IAW 8110-3 APPROVED DH SK 703-301.SDR UPS00831445Intercostal · corrodedINSPECTION TYPE:C1, STA 1390 AT LONG 34R INTERCOSTAL AND INTERCOSTAL SPLICE CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED IAW DWG 56166674 SRM 51-1-20D, 51-1-21.SDR UPS00831444Intercostal · corrodedINSPECTION TYPE:C1, STA 1440-1447 LONG 34R INTERCOSTAL UPPER FLANGE CORRODED BEYOND LIMITS. REMOVED, FABRICATED, REPLACED INTERCOSTAL IAW DWG 5616674, SRM 51-1 -21, 51-1-20D.SDR RRXA000418Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING, BOTTOM AFT CORNER OF DOOR JAMB AT STA 1220. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED FITTING IAW DC8 SRM 53-1-0 AND 53-2-0 FIG 1F. TREATED AREA IAW DC8 SRM 51-1-8. CORROSIONSDR UPS00831593Fitting · crackedINSPECTION TYPE:C123 RT WHEEL WELL BATH TUB FTG AT STA 920 IS CRACKED. REMOVED CRACKED FITTING, LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1-24. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D AND 51-3-0.SDR RRXA000445Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO Z FITTING AT STA 1220 AND LONGERON 34R - 33R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED Z FITTING IAW DC8 SRM 53-2-0. TREATED AREA IAW DC8 SRM 51-1-8, CORROSION DAMAGE RECORDEDSDR RRXA000444Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FUSELAGE INTERIOR SKIN AFT BAGGAGE COMP AT STA 1120 TO 1260 AND LONGERON 33L TO 27R., DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLEDSDR RRXA000437Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT CARGO COMP SKIN AT STA 1230 - 1260 AND LONGERON 36R - 32R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8, FABRICATED PART AND INSTALLED IAW DC8 SRM 53-2-0 ANDSDR RRXA000422Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BELLY SKIN AT STA 1150 TO 1130 AND LONGERON 36. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED BELLY SKIN IAW EAPD 08-53-029 AND DC8 SRM 53-2-0. TREATED AREA IAW DC8 SRM 51-1-8. CORROSION SDR UPS00831708Floorbeam · corrodedINSPECTION TYPE:C123 FLOORBEAM FS 1660 INBD AFT ENTRY DOOR HAS CORROSION. FABRICATED REPAIR ANGLE AND FILLER IAW REO G07052. INSTALLED REPAIR IAW REO G-07052 AND DC8 SRM 51-1-20D.SDR UPS00831662Doubler · corrodedINSPECTION TYPE:C1 STA 920-940 LBL 62 PRESSURE WEB AND FINGER DOUBLER ARE CORRODED BEYOND LIMITS. REPAIRED IAW 8110-3 DH SK 703-151, AND DWG 5645332.SDR RRXA000436Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO DOOR STOP FITTING 2ND FROM TOP RIGHT AFT SERVICE DOOR AFT JAMB. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-8 AND 51-3-0 FIG 2D. TREATED AREA IAW DC8 SRM 51-1-8.SDR UPS00831641Fitting · crackedINSPECTION TYPE:C1 STA 924 LBL 62 FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3649114, AND SRM 51-1-20D.SDR UPS00831640Fitting · crackedINSPECTION TYPE:C1 STA 1140 LONGERON 35R AFT FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3758497, AND SRM 51-1-20D.SDR UPS00831639Fitting · crackedINSPECTION TYPE:C1 STA 1140 LONGERON 35L AFT. FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3758497, AND SRM 51-1-20D.SDR UPS00831412Fitting · crackedINSPECTION TYPE:C1 LONGERON 31L SPLICE FITTING IS CRACKED AT STA 440-460. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-1-20D.
Back to Douglas DC-8-71F