Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA10854Skin · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO R/H MLG UPPER O/B DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 32-12-1 AND DC-8 SRM 51-3-0.SDR RRXA10849Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO LT. WING UPPER SURFACE UX-SPAR PANEL OVER MAIN LANDING GEAR AT STA. XW5 TO XW33, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IASDR RRXA10846Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO LT. WING T/E PANEL LWR. SURFACE AT STA. XW350, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 57-30-0.SDR RRXA10845Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO LT. WING T/E PANEL LWR. SURFACE AT STA. XW106, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 57-30-0.SDR RRXA10842Boss · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RETRACT PIN BOSS AT MLG SHOCK STRUT ASSSEMBLY, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O. 01-006 WITH APPROVED 8110-SDR RRXA10785Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO RT. WING SCISSORS PANEL AT FLAP SCISSORS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 2SDR RRXA010531Shim · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SHIM UNDER LONGERON 32R INSIDE ACCESS HOLE #60 AT STA 1793, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED ISDR RRXA010530Fitting · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE AFT END OF THE CANOE FITTING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA10851Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO LWR. WING PANEL AT RT AUX. SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA10803Skin · tornDURING A MAINTENANCE VISIT FOUND TORN DAMAGE TO FLAP SKIN AT SAT. 219 AND I/B FWD. SECTION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57SDR RRXA10870Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUBE FITTING AT STA. 1690 AND L32R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-SDR RRXA10869Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL #678 UNDER F/E TABLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CSDR RRXA10867Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO COCKPIT FLOOR PANEL #676F, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CORROSIOSDR RRXA10866Panel · corrodedDURING A MAINTENACE VISIT FOUND CORROSION DAMAGE TO R/H COCKPIT FLOOR PANEL #676A, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4. (CORROSDR RRXA10865Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CO-PILOTS FLOOR PANEL #676B AROUND PERIMETER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA10853Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO RT LWR. T/E PANEL AT STA XRS 219 TO XRS 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA10871Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO GALLEY FLOOR TOP SURFACE PANEL #328 AT STA. 55-80 AND X+32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA10855Panel · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO CENTER FLOOR PANEL BEHIND CENTER PADISTAL EDGE BENT & CRACKED AT SCREW HOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED RESDR RRXA10852Panel · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO UPPER T/E PANEL HINGE FOR SPOILER AT STA. 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 & 57-2-0.SDR RRXA10840Brace · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO RUDDER LOAD FEEL UNIT SUPPORT SIDE BRACE AT UPPER AND LOWER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AND DCSDR RRXA10838Retainer · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO D-PIT DOOR AT LWR. AFT DOOR RETAINER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 AND DC-8SRM 51-1-20D AND DC-8SDR RRXA10837Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON FITTING L34L AT STA 1260 AND C-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVE DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 5SDR RRXA010532Boss · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION TO THE MLG STRUT ASSY. RETRACT PIN BOSS & RETRACK PIN BY DOING MA-AI-3210-01:03, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW MA-A1-3210-SDR UPS01834877Fitting · crackedINSPECTION TYPE:C1, 3 STA 742 LONG 18L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4751640, AND SRM 51-1-20D.SDR RRXA10801Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO STRINGER #75 AND FWD SIDE STRINGER SPLICE AT STA. XCW 23 X=0 AND INSIDE R/H CENTER TANK THRU MID SPAR ACCESS 560E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATSDR RRXA10800Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LWR STRINGER#76 AT STA. XCW47&23 AND INSIDE R/H CENTER TANK THRU MID SPAR ACCESS 560E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA10786Stringer · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO STRINGER #76 AT STA. XCW23 AND XCW46 AND INSIDE L/H CENTER WING TANK THRU MID SPAR ACCESS HOLE 560E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DCSDR RRXA10872Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO GALLEY FLOOR TOP SURFACE PANEL #327 AT STA. 55-80 AND X+16, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA10835Frame · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO D-PIT DOOR FRAME DOUBLER AT AFT TOP CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA10817Plate · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO D-PIT KICK PLATE AT D-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.#01-006 WITH APPROVEDSDR RRXA10811Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TOR/H KEEL BEAM PANEL AT PLATE ATTACH POINT 30" FROM FWD. EDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSSDR RRXA10758Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT LWR. CARGO BILGE INTERNAL DOUBLER AT STA. 1155-1170 AND L35L TO L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PSDR RRXA10757Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT LWR. CARGO BILGE FUSELAGE SKIN AT STA. 1140-1170 AND L35L TO L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPASDR RRXA10756Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT. SIDE T/E FORMER AT STA. ZFS 175, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA10755Former · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT. SIDE T/E FORMER AT STA. ZFS 117, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010555Skin · damagedDURING A MAINTENANCE VISIT FOUND A SCREW PULLING THROUGH SKIN AND HOLES ELONGATED ON THE SLOT L/E PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-1A AND 51-1-21SDR RRXA010552Gusset · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED GUSSET AT FORMER AT STA 195, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA010548Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 227.335, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 ANDSDR RRXA010541Gusset · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE GUSSET BETWEEN STA XFS 195 AND STA XFS 201.250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SR. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 5SDR RRXA010558Former · crackedDURING A MAINTENANCE VISIT FOUND A 6" CRACK TO THE TOP FORMER AT STA XS 251.089, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTIVE///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010557Skin · damagedDURING A MAINTENANCE VISIT FOUND SCREWS PULLING THROUGH THE SKIN AT THE I/B SLOT VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-9.SDR RRXA010556Angle · crackedDURING A MAINTENANCE VISIT FOUND A 1" CRACK TO THE ANGLE AT CAP AT STA XS 225, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED ARE IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4 AND DC-8 SRSDR RRXA010554Skin · crackedDURING A MAINTENANCE VISIT FOUND A 1" CRACK TO THE BOTTOM SKIN AT CUT-OUT FOR PYLON AT STAY XFS 253.150, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW SDR RRXA010553Doubler · damagedDURING A MAINTENANCE VISIT FOUND AN AREA OF METAL BROKEN OUT AT THE CORNER ON THE BOTTOM SKIN DOUBLER AT STA XS 250.089, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-SDR RRXA010551Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ANGLE AT FORMER AT STA XS 195, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA010550Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-0 AND DC-SDR RRXA010549Former · crackedDURING A MAINTENANCE VISIT FOUND A 2 1/2" CRACK TO THE TOP FORMER AT STA XS 250.089, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-3-0 ANSDR RRXA010547Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 213.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010546Skin · crackedDURING A MAINTENANCE VISIT FOUND A 1 1/2" CRACK IN THE TOP L/E SKIN AND TWO DENTS BETWEEN STA XFS 141.250 TO STA XFS 147.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED RESDR RRXA010545Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLE ON THE O/B TOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.
Back to Douglas DC-8-71F