SDR UPS01834818Floor Support · corrodedINSPECTION TYPE:C1&3, STA 1717 TO 1725 LBL 10 FLOOR SUPPORT IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED SUPPORT IAW DWG 5755032 AND SRM 51-1-20D.SDR UPS01834816Clip · corrodedINSPECTION TYPE:C1&3, STA 1766 LONG 6L INTERCOSTAL TO BULKHEAD ATTACH CLIP IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED CLIP IAW DWG 5773844, AND SRM 51-1-20D.SDR UPS01834810Fitting · crackedINSPECTION TYPE:C1&3, STA 680 LONG 11L INTERCOSTAL TO FRAME FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4751625, AND SRM 51-1-20D.SDR UPS01834799Fitting · crackedINSPECTION TYPE:C1&3, STA 717 LONG 18L INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 4751640, AND SRM 51-1-20D.SDR UPS01834785Seat Track · corrodedINSPECTION TYPE:C1&3, STA 1670 - 1705 SEAT TRACK IS CORRODED BEYOND LIMITS AT RBL 24. REPAIRED SEAT TRACK SECTION IAW SRM 53-2-3 FIG 14.SDR UPS01834869Fitting · crackedINSPECTION TYPE:C1,3 STA 67 LONG 24R END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4611067, AND SRM 51-1-20D, 51-1-21.SDR RRXA10858Web · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO CABIN FLOOR BEAM WEB AT STA. 140-220 X=45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51SDR RRXA10834Bracket · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO D-PIT DOOR AT AFT ROLLER ATTACH BRACKET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 MM 52-32-1.SDR RRXA010663Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 140-160 X+45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG. 14.SDR RRXA010660Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN BETWEEN STA 1080-1100 BETWEEN L31L TO L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ---------------CX--------------- (WITHIN LIMITS)SDR RRXA010590Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 1040 X+46", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG.8A.SDR RRXA010589Seat Track · wornDURING A MAINTENANCE VISIT FOUND DEEP WEAR TO THE FO'S LT FWD SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA010588Seat Track · wornDURING A MAINTENANCE VISIT FOUND DEEP WEAR TO THE FO'S RT FWD SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA010587Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE FO'S LT AFT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 AND DC-8 SRM 51-1-20D.SDR RRXA010586Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES TO THE FO'S RT AFT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 AND DC-8 SRM 51-1-20D.SDR RRXA010585Seat Track · wornDURING A MAINTENANCE VISIT FOUND DEEP WEAR AREAS TO THE CAPT'S RT FWD SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D AND DC-8 SRM 53-2-3.SDR RRXA010584Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES TO THE CAPT'S LT AFT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA010583Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES TO THE CAPT'S RT AFT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA010582Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL AT STA XFS 163.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA010580Skin · damagedDURING A MAINTENANCE VISIT FOUND AN ELONGATED SCREW HOLE TO THE TOP T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-1.SDR RRXA010579Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE I/B END AT STA XFS 23.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. -----------------CX--------------(WITHIN LIMITS)SDR RRXA010577Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT AT O/B END OF THE L/E WITH BODY PUTTY INSTALLED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ----------CX---------- (WITHIN LIMITS)SDR RRXA10825Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FRAME AT FRAME 460-440 AND LONGERON 32L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O.#01-0SDR RRXA10666Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 70 X+45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG.14 AND DC-8 SRM 51-3-0.SDR RRXA010671Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN AND DOUBLER AT STA 1160 TO 1170 L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.OSDR RRXA010670Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE INSIDE LIGHT HOLE TO THE SKIN AND DOUBLER AT STA 11160-1170 L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSSDR RRXA010669Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN AND DOUBLER AT STA 1160-1170 L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O#01SDR RRXA010668Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN & DOUBLER AT STA 1160-1140 L36, DAMAGE EXCEEDED LIMITATIONS IAW SC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW E.O.#01-0SDR RRXA010667Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 240-260 X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG. 14.SDR RRXA010665Seat Track · crackedDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 120-140 X-45", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3.SDR RRXA010664Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 140-160 X+-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG. 14.SDR RRXA010662Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 140-160 X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0 AND DC-8 SRM 53-2-3 FIG. 14.SDR RRXA010661Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 140-160 X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-2-3.SDR RRXA010659Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN R/H AFT FILLET AREA BETWEEN STA 1100-1080 L29R TO L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ---------------CX--------------- (WITHIN LIMITS)SDR RRXA010657Spoiler Panel · tornDURING A MAINTENANCE VISIT FOUND A TEAR TO THE I/B END OF RT WING O/B FLIGHT SPOILER LWR EDGE TRIM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SDR RRXA10857Floor Panel · damagedDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO FLOOR PANEL AT STA. 55 X= -40, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4 & 53-2-0.SDR RRXA10826Plate · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO B-PIT DOOR KICK PLATE AT B-PIT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW E.O.01-006 WITH APPROVED 8110-3 DATED 01/12/01.SDR RRXA10782Skin · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLE DAMAGE TO SEVERAL L/E FASTENERS THRU EDGE OF SKIN AT STA. XFS 470, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0 SDR UPS01834633Rod End · brokenINSPECTION TYPE:N/A, CLIMBING THRU FL260 AT 320 KIAS A SUDDEN DEAFENING NOISE ACCOMPANIED BY CONSIDERABLE VIBRATION STARTED. SLOWING TO 200 KTS REDUCED THE NOISE AND VIBRATION TO TOLERABLE INTENSITY. NO PRESSURIZATION PROBLEMS WERE NOTED. VISUAL INSP THRU NSDR RRXA10832Doubler · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMGE TO C-PIT DOOR AT FWD. LT DOUBLER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA10818Doubler · bentDURING A MAINTENANCE VISIT FOUND BENT DAMAGE TO A-PIT DOOR CUTOUT AT UPPER AFT ADGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLEDM IAW DC-8 SRM 51-1-21.SDR RRXA010658Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE R/H RIB ATTACH ANGLE KEEP BEAM BETWEEN MAIN GEAR DOORS AT STA 940 RBL 3 1/2", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PASDR RRXA10796Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO RT. WING I/B FLAP T/E LOWER SURFACE AT RT. WING I/B FLAP AND BEHIND #8 TIRE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARSDR RRXA10795Skin · damagedDURING A MAINTENANCE VISIT FOUND HOLE DAMAGE TO RT. WING I/B FLAP LWR. SURFACE AT RT WING I/B FLAP BEHIND NR 7 TIRE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED IAW DC-8 SRM 51-1-8. FRABICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-1 FIGSDR RRXA10780Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO L/H WING T/E AT STA. XRS 19 TO XRS 90 AND UPPER SURFACE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIRS AND INSTALLED SDR RRXA10774Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT. WING I/B FLAP SKIN IB SURFACE AT STA. XW106, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SDR RRXA10820Skin · misrepairedDURING A MAINTENANCE VISIT FOUND IMPROPER REPAIR DAMAGE TO D-PIT DOOR KICK PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA10808Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO SKIN AT O/B AFT END OF R/H W/W BELOW FIRE BOTTLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE,TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC8- SDR RRXA003718Skin · crackedDURING A MAINTENANCE VISIT FOUND A SMALL CRACK JUST O/B OF EXHAUST ON THE RT WING O/B FLAP T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR FWT2001F00001Altimeter · erraticON CLIMB OUT MIA AT 17,000 CAPT. ALTIMETER BECAME ERRACTIC AND STICKING AND GIVING ERRONEOUS READINGS, LOG BOOK, PAGE 201510. REMOVED AND REPLACED CAPT. ALTIMETER, ACCOMPLISHED PITOT STATIC SYSTEM LEAK CHECK AND OPS CHECK- FOUND NORMAL IAW MM. PITOT STATIC T
Back to Douglas DC-8-71F