Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS01834841Fitting · crackedINSPECTION TYPE:C1&3, STA 440 - 460 LONG 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257, AND SRM 51-1-20D.SDR UPS01834836Fitting · crackedINSPECTION TYPE:C1&3, STA 600 - 620 LONG 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257, AND SRM 51-1-20D.SDR UPS01834834Fitting · crackedINSPECTION TYPE:C1&3, STA 440 - 460 LONG 34R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750330, AND SRM 51-1-20D.SDR UPS01834817Rib · crackedINSPECTION TYPE:C1&3, RIGHT INBOARD FLAP RIB IS CRACKED AT AFT SPAR MOST I/B RIB AT XCW 64. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS01834783Doubler · crackedINSPECTION TYPE:C1&3, RIGHT WING CENTER L/E LOWER INTERNAL DOUBLER IS CRACKED AT XFS 335. 250. REMOVED, FABRICATED, AND REPLACED DOUBLER IAW DWG 5769589, AND SRM 51-1-20D, 51-1-21.SDR UPS01834781Rib · crackedINSPECTION TYPE:C1&3, RIGHT WING L/E UPPER RIBS ARE CRACKED AT FASTENER END AT XFS 297.5, XFS 354. REPAIRED RIBS IAW SRM 57-2-0 FIG 2.SDR UPS01834777Rib · crackedINSPECTION TYPE:C1,3 RIGHT WING L/E UPPER RIBS ARE CRACKED AT FASTENER END AT XS442.185, XS448.581, XS467.323, XS478.897. REPAIRED RIBS IAW SRM 57-2-0 FIG 2.SDR UPS01834731Battery Pack · inoperativeINSPECTION TYPE:PFLT EMERGENCY EXIT LIGHTS INOP ON PREFLIGHT SAFETY CK. REMOVED AND REPLACED EMERGENCY BATTERY PACK. OPS CK GOOD.SDR RRXA10833Doubler · crackedDURING A MAINTENANACE VISIT FOUND CRACK DAMAGE TO C-PIT DOOR AT FWD. RT. DOUBLER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA10821Seat Track · wornDURING A MAINTENACE VISIT FOUND WORN DAMAGE TO SEAT TRACK AT STA. 220-240 X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0 AND DC-8 SRMSDR RRXA10816Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO F/E SEAT TRACK AT FWD & AFT FE'S SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA10815Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO CO-PILOTS SEAT TRACKS AT LT. AND RT. CO-PILOTS SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51SDR RRXA10814Seat Track · wornDURING A MAINTENANCE VISIT FOUND WORN DAMAGE TO PILOTS SEAT TRACKS AT LT AND RT PILOTS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA10779Vane · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLE DAMAGE TO LT WING O/B SLOT VANE AT O/B SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-4 AND DC-8 SRM 57-2-1 AND DC-8 SDR RRXA10778Panel · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT WING I/B SLOT PANEL AT LT I/B SLOT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. PEMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010614Seat Track · wornDURING A MAINTENANCE VISIT FOUND A WORN SEAT TRACK AT STA 857-879 X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG8A.SDR RRXA010613Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 320-340 X=+20, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 & 53-2-3 FIG.8A.SDR RRXA010612Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 320-340 X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG.8A.SDR RRXA010611Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 859-879 X-49, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG.8A.SDR RRXA010610Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 420 X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG.8A.SDR RRXA010609Seat Track · wornDURING A MAINTENANCE VISIT FOUND EXCESSIVE WEAR TO THE SEAT TRACK AT STA 940-960 X-49, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 & 53-2-3 FIG.8A.SDR RRXA010608Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 297.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010607Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 304.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010606Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 372.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010605Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 442.185, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-1-SDR RRXA010604Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 454.976, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-SDR RRXA010603Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 461.372, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-SDR RRXA010602Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 467.323, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-1-SDR RRXA010601Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XS 478.897, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 & 51-1-SDR RRXA010600Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 797.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0.SDR RRXA010599Former · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP T/E FORMER AT STA XFS 735, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0SDR UPS01834880Fitting · corrodedINSPECTION TYPE:C1, 3 STA 940 FRAME FITTING AT RBL 60 IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED FRAME FITTING IAW 8110-3 APPROVED 8110-3 DH SK 701-332, AND SRM 51-1-20D, 51-1-21, 53-1-0.SDR UPS01834875Seat Track · corrodedINSPECTION TYPE:C1, 3 STA 590 RBL 24 SEAT TRACK CORRODED BEYOND LIMITS. REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 8A.SDR UPS01834870Fitting · crackedINSPECTION TYPE:C1,3 STA 340 LONG 33R O/B BANANA FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755847, AND SRM 51-1-20D.SDR UPS01834865Seat Track · brokenINSPECTION TYPE:C1,3 STA 250 BL 0 MAIN CABIN SEAT TRACK HAS A BROKEN TANG. REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 6D.SDR UPS01834843Fitting · crackedINSPECTION TYPE:C1&3, STA 680 BL 0 FLOORBEAM VERTICAL SUPPORT FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 5773275, AND SRM 51-1-20D.SDR UPS01834842Fitting · crackedINSPECTION TYPE:C1&3, STA 742 LBL 24 FLOORBEAM ATTACH FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755222, AND SRM 51-1-20D.SDR UPS01834840Fitting · crackedINSPECTION TYPE:C1&3, STA 720 LBL 63 FLOORBEAM VERTICAL SUPPORT FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3616948, AND SRM 51-1-20D.SDR UPS01834839Floorbeam · crackedINSPECTION TYPE:C1&3, STA 680 LBL 48 VERTICAL FLOORBEAM SUPPORT ANGLE IS CRACKED. REMOVED, FABRICATED AND REPLACED ANGLE IAW DWG 5773275, AND SRM 51-1-20D.SDR UPS01834835Longeron · crackedINSPECTION TYPE:C1&3, STA 1740 LONG 15R IS CRACKED. REMOVED, FABRICATED, AND REPLACED LONGERON SECTION IAW DWG 5649327, AND SRM 53-2-2 FIG 10.SDR UPS01834814Fitting · crackedINSPECTION TYPE:C1&3, STA 781 LBL 24 FLOORBEAM ATTACH FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3773906, AND SRM 51-1-20D.SDR UPS01834813Fitting · crackedINSPECTION TYPE:C1&3, STA 822 LBL 24 FLOORBEAM ATTACH FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755222 AND SRM 51-1-20D.SDR UPS01834812Fitting · crackedINSPECTION TYPE:C1&3, STA 717 LBL 24 FLOORBEAM ATTACH FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3773906, AND SRM 51-1-20D.SDR UPS01834789Fitting · crackedINSPECTION TYPE:C1&3, STA 822 RBL 63 INTERCOSTAL TO FRAME FITTING IS CRACKED. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 4753360, AND SRM 51-1-20D.SDR UPS01834779Fitting · crackedINSPECTION TYPE:C1&3, STA 781.5 FLOORBEAM ATTACH FITTING IS CRACKED AT RBL 24. REMOVED AND REPLACED FITTING IAW DWG 3755222 AND SRM 51-1-20D.SDR UPS01834879Floor Support · corrodedINSPECTION TYPE:C1, 3 STA 1766 RBL 10 - 18 FLOOR SUPPORT IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED SUPPORT IAW DWG 5753522, AND SRM 51-1-20D, 51-1-21A.SDR UPS01834871Fitting · crackedINSPECTION TYPE:C1,3 STA 834 - 857 LONG 1 SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4750521, AND SRM 51-1-20D.SDR UPS01834866Fitting · crackedINSPECTION TYPE:C1,3 STA 857 LONG 7R END FITTING IS CRACKED. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 3779659, AND SRM 51-1-20D, 51-1-21.SDR UPS01834846Fitting · crackedINSPECTION TYPE:C1&3, STA 675 LONG 4L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3779762, AND SRM 51-1-20D, 51-1-21, 51-1-23.SDR UPS01834837Fitting · crackedINSPECTION TYPE:C1&3, STA 759 LONG 18L INTERCOSTAL TO FRAME ATTACH FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4751640, AND SRM 51-1-20D.
Back to Douglas DC-8-71F