Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS01836147Skin · crackedINSPECTION TYPE:C1 NR 4 PYLON O/B WEB PNL FWD ACCESS HOLE HAS APPROX 1 INCH CRACK ON LWR SIDE. REMOVED FASTENER -22 & -28 IAW REO G08127 DC8 SRM 51-1-21 51-1-20D & 51 -3-0 MAT ID FOR -3 -5 DOUBLERS .125 7075-T6 PO 340779 IAW REO G08127. LOCATED AND DRILLED -SDR RRXA11215Doubler · chafedDURING A MAINTENANCE VISIT FOUND CHAFFED DAMAGE TO L/H MLG DOOR LOWER AFT STMP AND CORNER OF DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 52-2-0, 51-1-20A SDR RRXA11214Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO A-PIT FRAME FITTING AT STA.270 AND L30R-L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51SDR RRXA11213Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO INTERCOSTAL ATTACH FITTING AT STA.1240 AND L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRMSDR RRXA11212Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TOINTERCOSTAL ATTACH FITTING AT STA.1140 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM SDR RRXA11211Splice · brokenDURING A MAINTENANCE VISIT FOUND BROKEN DAMAGE TO MAIN CABIN SEAT TRACK SCALLOPS AT STA.540 AND RBL60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 53-2-3.SDR RRXA11210Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO L/H AFT WING TO BODY FAIRING SUPPORT BRACKETT, LOWER FORWARD ANGLE AT STA.910, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PSDR RRXA11209Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER LIP OF FRAME AT STA.1120 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 5SDR RRXA11208Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 31L AT STA.660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-0. (SDR RRXA11207Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO AFT ACCY. COMPARTMENT FLOOR BEAM FITTING AT STA1660 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR RRXA11206Intercostal · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO D-PIT INTERCOSTAL AT STA.1520-1540 AND L33L AND UNDER CARGO TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTSDR RRXA11205Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO AFT ACCY. COMPARTMENT FLOOR BEAM AT STA.1660 AND RBL31, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-11 AND DSDR RRXA11204Bracket · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO RT AFT WING TO BODY FAIRING SUPPORT BRACKET LOWER FORWARD ANGLE BRACKET AT STA.910, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DSDR UPS01836150Stop Fitting · corrodedINSPECTION TYPE:C1 AFT PIT D-DOOR LT STOP CORRODED. REPLACED DOOR STOP IAW DC8 SRM 51-1-24.SDR DHL2001805013Autopilot Sys · malfunctionedAUTOPILOT BANKS 40 DEGREES TO LEFT IN HDG MODE. OVERSHOOTS HEADING SELECTED BY 10 - 12 DEGREES. SWAPPED NR 1 & 2 FOGS. BOTH CK OK IAW LITTON EO 41007 DOC 464544. A/P CKS OK ON BOTH SIDES IAW 22-10-00. ROLL CHANNEL BITE CKS OK IAW 22-12-00.SDR RRXA11203Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING L/E RIB AT STA. XFS785, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 FIG.2, 5SDR RRXA11202Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E RIB AT STA. XFS778.25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 FSDR RRXA11201Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E UPPER RIBS AT STA. XFS716.25, 728.75, 735, 741.25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20DSDR RRXA11200Doubler · brokenDURING A MAINTENANCE VISIT FOUND BROKEN DAMAGE TO RT ELEVATOR O/B TIP CORNER BROKEN OFF, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 55-2-0, 51-3-0, 51-1-21.SDR RRXA11199Skin · puncturedDURING A MAINTENANCE VISIT FOUND PUNCTURE DAMAGE TO #1 ENGINE I/B T/R COWL INNER HEAT SHIELD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA11198Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO NR 2 ENGINE INLET COWL I/B STRAKE ON LOWER LATCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0, 51-1-21 AND DWG D5SDR RRXA11197Skin · gougedDURING A MAINTENANCE VISIT FOUND GOUGED DAMAGE TO L/H O/B FLAP BELOW FLAP HINGE AT STA. XRS340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRMSDR RRXA11196Panel · puncturedDURING A MAINTENANCE VISIT FOUND PUNCTURE DAMAGE TO FLOOR PANEL AT STA.1760, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-3, 51-1-21.SDR RRXA11195Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT WING O/B L/E LOWER SKIN AT STA.XFS597.5 AND DRAIN HOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 FIG.2A.SDR UPS01836149Fitting · crackedINSPECTION TYPE:C1 AFT PIT FS 1140 L35R INTERCOSTAL ATTACH FITTING IS CRACK. REMOVED AND REPLACED NEW FITTING IAW DC8 SRM 51-1-20D.SDR UPS01836016Light · inoperativeINSPECTION TYPE:N/A DURING BISE CHECK THE EMERGENCY LIGHT ON THE GLARESHIELD AND OVER CREW ENTRY DOOR DO NOT ILLUMINATE. REMOVED AND REPLACED BATTERY PACK AND RELAY UNIT, OPS CHECKS GOOD IAW MM 33-50-01.SDR RRXA11194Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT WING O/B L/E LOWER RIBS AT STA. XFS660-641.25-653.75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D, SDR RRXA11193Doubler · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING CENTER L/E INTERNAL DOUBLER LOCATED AT DRAIN HOLE AT STA. XFS337, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART SDR RRXA11192Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING L/E LOWER RIB AT STA. XFS653.75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0SDR RRXA11191Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E UPPER RIB AT STA.XFS616.25-622.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SSDR RRXA11190Splice · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO SPLICE AT STA.610 AND L31L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D, 53-1-01 ANSDR RRXA11189Frame · misdrilledDURING A MAINTENANCE VISIT FOUND MISSDRILLED HOLE DAMAGE TO MAIN CABIN LT LOWER SIDE OF FRAME AT STA.1560, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 FIG.1F, 5SDR RRXA11188Skin · chafedDURING A MAINTENANCE VISIT FOUND CHAFFING DAMAGE TO LT HORIZ STAB FIXED LOWER FAIRING AT AFT END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK 606-648.SDR RRXA11187Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACKED DAMAGE TO LT WING L/E UPPER RIB AT STA. XFS 610, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 SDR RRXA011045Transceiver · defectiveDURING CLIMBOUT, RADAR SMOKING CONTINUOUSLY AND TOTALLY UNUSABLE. REMOVED AND REPLACED WX R/T IAW DC-8 MM 34-40-2. GROUND CHECK AND OPS GOOD.SDR UPS01836148Fastener · looseINSPECTION TYPE:C1 1 FASTENER LEAKING FUEL AT XRS 500 BOTTOM NR 4 ALT. REMOVED FASTENER IAW DC8 SRM 51-1-20D OVERSIZED HOLE FOR BUSHING INSTALLATION AS REQD PER REO G0123, FABBED BUSHING AND INSTALLED PER REO G0812 3. INSTALLED NEW DOUBLER -502 IAW DC8 SRM 5SDR RRXA11186Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E RIBS AT STA. XFS672.5-678.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. NDT HFCC INSP IAW SPM06-10-01.001. FABRICATEDSDR RRXA11185Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FRAME AT STA.460 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS IAW DC-8 SRMSDR RRXA11184Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT WING O/B L/E LOWER RIB AT STA. XFS622.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0, 57-2-0 FIG.2.SDR RRXA11183Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H I/B FLAP I/B L/E IN TWO AREAS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 57-7SDR RRXA11182Skin · tornDURING A MAINTENANCE VISIT FOUND TORN SKIN DAMAGE TO L/H WING UPPER T/E SKIN AT #1 SPOILER O/B HINGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DCSDR RRXA11181Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FLOOR SUPPORT ANGLE AT STA.1260 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-2SDR RRXA11180Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E UPPER RIB AT STA.XFS610-566.25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. HFCC INSPECTION IAW SPM 06-10-01.001. FABRSDR RRXA11179Doubler · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO L/H WING O/B L/E LWR INTERNAL DOUBLER AT STA.XFS597.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D ANDSDR RRXA11178Rib · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO L/H WING L/E UPPER RIB AT STA.XFS691.25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-SDR RRXA11177Web · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO AFT LOWER CORNER WEB AT FORWARD ENTRY DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-SDR RRXA11176Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO L/H O/B LOWER T/E WEDGE LOWER SURFACE AT STA. 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA11174Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LOWER R/H FUSELAGE SKIN AT STA.1390 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SDR RRXA11173Intercostal · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO A-PIT DOOR RAMP FORWARD INTERCOSTAL SUPPORT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA11172Channel · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO A-PIT CROSS SLIDE DOOR RAMP AT HOLD OPEN STRUT ATTACH ANGLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED
Back to Douglas DC-8-73F