Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA003084Skin · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SKIN CRACKED ON THE AFT SKIN LAP AFT OF MEG SPLICE AT STA 1690-1763 AND L28L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ISDR RRXA003076Structure · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT LWR FWD CORNER IN THE AFT BAGG COMPT DOOR 'D' INNER DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAAW DC-8 SRM 51-1-9.SDR RRXA003073Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT I/B SIDE OF FRAME IN THE CABIN CUSP EXTRUSION AT STA 1040 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-SDR RRXA003072Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN 2 PLACES ON THE AFT CARGO COMPT DOOR 'D' SEAL RETAINER ON AFT LWR CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALSDR RRXA003070Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FRAME LEG IN THE AFT CARGO COMPT AT STA 1420 AND L34R-L36R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTASDR RRXA003067Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPT FRAME SPLICE AT STA 1420 ABD L34R-L36R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLEDSDR RRXA003066Skin · misinstalledDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE FWD PASSENGER DOOR EXTERIOR SKIN UPPER AFT CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0 FIG 2.SDR RRXA003065Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPT FRAME LEG FWD SIDE AT STA 1260 AND L33R-L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSSDR RRXA003059Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE AFT CARGO COMPT. OVERHEAD ANGLE SUPPORT FOR BAGG LINER AT STA 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ASDR RRXA003056Angle · crackedDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE CABIN RT CUSP EXTRUSION AT STA 1680, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0.SDR RRXA003694Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE OVERHEAD ANGLE SUPPORT AFT SIDE FOR BAGG LINER AT STA 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2SDR RRXA003693Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME SPLICE AT STA 1420 AND L34R-36R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE IAW DC-8 SRM 51-1-21. (CORROSIONSDR RRXA003692Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME LEG FWD SIDE AT STA 1260 AND L33R - 34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-4 FIG 23, 53-2SDR RRXA003686Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE OVERHEAD ANGLE SUPPORT FOR BAGGAGE LINER AT STA 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (SDR RRXA003071Cable Drum · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND ENTIRE PARAMETER O/B SIDE 'A' CARGO DOOR CONTROL CABLE DRUM HUB AT STA 290 AND L21R-L22R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRMSDR UPS00833375Indicator · damagedINSPECTION TYPE:N/A, PASSING 13,000 FT A SWEET CHEMICAL SMELL OR ODOR WAS NOTICED. TURNED A/C PACKS OFF ONE AT A TIME AND WHEN LEFT PACK WAS OFF ODOR DECREASED. AFTER LEVEL OFF ODOR GOT WORSE. DECIDED TO DIVERT TO MCO AND RAN FUMES EVACUATION CHECKLIST. AFSDR RRXA001015Gyro · failedNR 1 COMPASS FAIL. REMOVED AND REPLACED NR 1 DG NR 1 COMPASS, OP CHECKS GOOD IAW DC-8 M/M CH 34-21.SDR RRXA003057Doubler · crackedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE EXISITING REPAIRS ON THE EXTERIOR OF CARGO DOOR IN THE CARGO COMPT. A, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW SDR DHL2000801147Pressure Panel · crackedSMALL CRACK O/B SIDE LEFT MLG WHEEL WELL. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER ON INDICATED AREA PER SRM 53-2-0.SDR RRXA002864Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SHEARED FASTENERS ON THE LWR SURFACE AT THE I/B SIDE ON THE LT WING O/B AILERON, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAWSDR RRXA002863Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING LWR SKIN AT A FASTENER HOLE AT STA XFS 435, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW SERVICE REWORK DWG 08570013 ANSDR RRXA002862Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT A FASTENER HOLE AT THE LWR L/E CAP AT THE FWD SPAR ATTACHMENT ON THE RT WING L/E 6 INCHES I/B OF STA XFS 710, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED ASDR RRXA002861Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE BOTTOM OF THE FUSELAGE WHERE THE NR 1 ADF ANTENNA MOUNTS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0SDR RRXA002860Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM AT FS 920 AND LBL 48 - 53, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DALFORT AEROSPACE LP XEA X8-53-880 REVSDR RRXA002859Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT FS 41 - 58 AND LBL 31 - LBL 44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSISDR RRXA002858Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME AT FS 25 AND STR 36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-20D. (CORROSION DAMASDR RRXA002857Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INNER SKIN OF THE NR 2 ENGINE I/B THRUST REVERSER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 78-31-10.SDR RRXA002856Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LOWER SIDE OF THE FLOOR WEB AT FS 25 - 55 AND LBL 57, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (SDR RRXA002855Shear Tie · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SHEAR TIE AT FS 640 AND STR 27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA002854Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ATTACH ANGLE AT THE LT WING T/E FLAP WELL PANEL AT STA XCW 69.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 ASDR RRXA002853Shear Tie · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SHEAR TIE AT FS 640 AND STR 27L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA002852Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE WEB AT FS 70 AND STR 21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-21.SDR RRXA002851Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE FLOOR PLANK AT FS 1020 - 1023 AND RBL 17, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (SDR RRXA002850Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM ON THE FWD AND AFT FLANGES AT FS 940 AND RBL 53, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DALFORT AEROSPACSDR RRXA002849Lever · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT THE NECK DOWN AREA WITH HFEC ON THE NR 1 THROTTLE LEVER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA002848Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SUPPORT ANGLE IN THE LT W/W FOR THE SPOILER MIXER ASSY, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21.SDR RRXA002847Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON THE LT WING FLAP HINGE SUPPORT FITTING ASSY ON O/B SIDE OF FITTING AT STA XF 409.667, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PART IAW SDR RRXA002846Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LONGERON END FITTING AT FS 8 AND L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA002845Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON THE FRAME AT FS 260 AND STR 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA002844Lever · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT THE NECK DOWN AREA WITH HFEC ON THE NR 1 THROTTLE LEVER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA002843Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SUPPORT ANGLE IN THE LT W/W FOR THE SPOILER MIXER ASSY, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21. SDR RRXA002842Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING FLAP HINGE SUPPORT FITTING ASSY ON THE O/B SIDE OF FITTING AT STA XF 409.667, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW SDR RRXA002841Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE END FITTING OF LONGERON 30R AT FS 8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8S RM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA002840Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE FLOOR PLANK AT FS 1260 AND LBL 17, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA002839Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT FS 770 AND BL 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDSDR RRXA002838Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT FASTENER HOLE ON THE RT WING L/E LWR SURFACE AT STA XFS 301.888, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DALFORT AEROSPACE LP XESDR RRXA002837Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT WHEEL WELL PRESSURE FLOOR AT FS 930 - 943 AND RBL 56 - 64 WL-1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DALFORT SDR RRXA002836Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FRAME AT FS 260 AND STR 33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR RRXA002788Actuator · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING FLAP ACTUATOR CRANK (KNUCKLE) AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW MM 27-51-9.SDR RRXA003068Pan · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN THE LOWER PAN AT THE END OF DOOR ON THE AFT BAGGAGE DOOR "D", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-24, 51-1-4
Back to Douglas DC-8-73F