SDR UPS00832438Floor Support · corrodedINSPECTION TYPE:C2, FWD PIT STA 100 RT FLOORBEAM SUPPORT LOWER END CORRODED. REMOVED STANTION AT STA 100 RT IAW DC8 SRM 51-1-20D, OUT OF LIMITS IAW DC8 SRM 53-2-0. RECEIVED NEW STANTION (P/N 3773077-510N), PO 256499, DRILLED STANTION IAW DAC 3773077. ALODINSDR UPS00832437Fitting · crackedINSPECTION TYPE:C2 AFT LWR CARGO PIT AT FS 1270 LONG 31L SPLICE FITTING CRACKED. REMOVED AND REPLACED SPLICE FITTING IAW DC8 SRM 51-1-20D.SDR UPS00832496Frame · corrodedINSPECTION TYPE:C2, AFT PIT FS 1060 CORROSION ON LWR SURFACE OF UPPER FRAME FLANGE AT L36, L34L & L35L & ALSO ON FRAME CAP AT L36. REMOVED DAMAGED SECTION OF FRAME. FABBED REPAIR PARTS. ALODINED AND PRIMED REPAIR PARTS AND DAMAGED AREA. INSTALLED REPAIR IASDR UPS00832506Fitting · corrodedINSPECTION TYPE:C2, AFT LOWER CARGO PIT A FS 1195 BETWEEN L33R -L34R CROSS SLIDE DOOR 4TH FROM FWD LATCH FITTING CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REPLACED FITTING IAW DC8 SRM 51-1-20D & 53-2-0.SDR UPS00832457Web · corrodedINSPECTION TYPE:C2, AFT LWR PIT AT FS 1180 BETWEEN LONG 33R - 34R DOORWAY WEB IS CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8, FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0. GEN AND RECRFTS 818UP-14-20292 W/REO G07302. FAB DOUBLERS IAW REO G07302. ALODINESDR UPS00832456Fitting · corrodedINSPECTION TYPE:C2, AFT LWR CARGO PIT AT FS 1190 BETWEEN L33R - 34R 3RD FROM FWD CROSS SLI DE DOOR LATCH FITTING CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8. FOUND TO BE OUT OF LIMITS IAW DC 8 SRM 53-2-0. REMOVED FITTING IAW DC8 SRM 51-1-20D. LOCATED ANSDR UPS00832445Fitting · corrodedINSPECTION TYPE:C2, FITTING CORRODED AT FS 1200 L31L AFT LOWER CARGO COMPARTMENT. REMOVED CORRODED FITTING, LOCATE NEW FITTING AND DRILL EXISTING FAST ENER HOLES AND INSTALLED NEW FITTING.SDR RRXA002018Cowl Door · damagedDURING A MAINTENANCE VISIT FOUND A LARGE SCRATCH AND CREASE ACROSS RT FWD COWL DOOR LWR SECTION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-055 WITH APPROVED 8110-3 DSDR RRXA001884Cowl Door · damagedDURING A MAINTENANCE VISIT FOUND A LARGE SCRATCH AND CREASE ACROSS RT FWD COWL DOOR LWR SECTION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED CREASES AND GOUGES WITH A ERODINAMIC DECON PUTTY AND PAINTED ISDR UPS00832507Frame · crackedINSPECTION TYPE:C2, MAIN CABIN STA 1540 AT L21L (CUSP) FRAME ATTACHMENT. REMOVED AND REPLACED FRAME SECTION IAW DC8 SRM 53-2-0, FIG 2.SDR UPS00832465Attach Fitting · crackedINSPECTION TYPE:C2, CABIN STA 320 L21L, A FRAME TO CUSP ATTACH FITTING, CRACKED FRAME. REMOVED DAMAGED SECTION OF FRAME, INSTALLED NEW FRAME SECTION AND SPLICES IAW DC8 SRM 53-2-0 FIG AND 51-7-20D.SDR UPS00832464Frame · corrodedINSPECTION TYPE:C2, CABIN STA 1040 L21L AT ATTACH FITTING, FRAME, CRACKED AND CORRODED. REMOVED CORRODED FRAME SECTION AT FS 1040 TO L18L-L21L. FABRICATED NEW SECTION IAW DC8 SRM 53-0265. FABRICATED -29, -31, -33 & -35 REP AIR SPLICES IAW DC8 SRM 53-2-0. ASDR UPS00832463Web · corrodedINSPECTION TYPE:C2, CABIN STA 409 L21L CUSP CORRODED AS MARKED. REMOVED CORROSION AND REPAIRED AREA IAW REO-G07299.SDR DHL200080410CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 400 L-34 RT. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 51-1-21 AND 53-2-0.SDR RRXA002028Bulkhead · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT PRESSURE BULKHEAD AT STA 1766 RT AND RBL 25.5 INCHES TO 27 INCHES 34.5 INCHES TO 34.75 INCHES & 35.5 INCHES TO 35.75 INCHES Z AXIS + 65.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED ANSDR RRXA002027Bulkhead · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT PRESSURE BULKHEAD AT STA 1766 LT AND LBL 24.25 INCHES TO 27.25 INCHES & 33.5 INCHES TO 36.25 INCHES LBL Z AXIS + 65.5 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREASDR RRXA001916Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE UPPER SURFACE OF THE RT I/B AUX TANK FROM STA XFS 13 TO 135, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAWSDR RRXA001915Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGED AND A SCREW MISSING ON THE UPPER SURFACE RT LEADING EDGE STUB WING AT STA XFS 550, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLESDR RRXA001898Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT WING LWR AUX SPAR PANEL AT XW 90 TO XW 138, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PANEL IAW DC-8 SRM 51-3-0. CORROSISDR RRXA001897Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT WING LWR AILERON POWER PACK AT PANEL NR 540, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PANEL NR 540 IAW DC-8 SRM, SDR RRXA001894Bulkhead · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT PRESSURE BULKHEAD AT STA 1766 RT AND RBL 25.5 TO 27, 34.5 TO 34.75 AND 35.5 TO 35.75 Z AXIS + 65.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABSDR RRXA001893Bulkhead · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT PRESSURE BULKHEAD AT STA 1766 LT AND LBL 24.25 TO 27.25 & 33.5 TO 36.25 LBL Z AXIS + 65.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ASDR RRXA001780Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE UPPER SURFACE ON THE RT IB AUX TANK AT STA XFS 13 TO 135, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLER AND INSTALLED IASDR RRXA001779Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE SCREW HOLE ON THE UPPER SURFACE RT LE STUB WING AT STA XFS 550, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. INSTALLED FASTENER PER E.O. 00SDR RRXA001762Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING LWR. AUX SPAR PANEL AT XW 90 TO XW 138, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLEED NEW PANEL IAW DC-8 SRM 51-3-0.SDR RRXA001761Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING LWR. AILERON POWER PACK PANEL NR 540, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW PANEL IAW DC-8 SRM 51-3-0.SDR UPS00832508Fitting · corrodedINSPECTION TYPE:C2, AFT LWR CARGO PIT AT FS 1180 CROSSSLIDE DOOR WAY 2ND FROM FWD LATCH FITTING IS CORRODED AT LONG 33R. REMOVED CORROSION IAW DC8 SRM 51-1-8, FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0. REMOVED DAMAGE IAW DC8 SRM 51-1-20D. LOCATED AND DRSDR DHL200080411CFloor Support · crackedMAIN CARGO COMPARTMENT NR 1D FLOOR CRACKED 1 INCH. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-3 AND 51-1-8.SDR UPS00832317Angle · corrodedINSPECTION TYPE:C1, STA 270 - 280 LONG 27R INTERCOSTAL ATTACH ANGLE IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED ANGLE IAW DWG 9754020 AND SRM 51-1-20D.SDR UPS00832310Fitting · crackedINSPECTION TYPE:C1, WING BOX STA 680 LBL 60 FITTING IS CRACKED, UPPER SPAR CAP TO FRAME FITTING. REMOVED AND REPLACED FITTING IAW DWG 3642974 AND SRM 51-1-20D.SDR RRXA000225Oil Cap · unsecureLOST OIL PRESSURE & QUANTITY ON NR 4 ENGINE AT 1439Z. PERFORMED CHECKLIST FOR ABNORMAL OIL PRESSURE, SHUT ENGINE DOWN, MONITORED ALL OTHER ENGINE FUNCTIONS UNTIL LDG AT MCO. CORRECTIVE ACTION : FOUND OIL CAP OFF, PUT CAP BACK ON. SERVICED WITH OIL, RANSDR RRXA001938Skin · damagedDURING A MAINTENANCE VISIT FOUND THAT THE WING SKIN AT STR 64 LT WING NEEDED TO BE MODIFIED PER MA-AM-5732-03:00, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE. COMPLIED WITH LOWER WING SKIN MODIFICATION STRINGER 64 IAW EWA EO AM-5732-04:00.SDR RRXA001917Skin · damagedDURING A MAINTENANCE VISIT FOUND THE LWR WING SKIN AT STR 64 RT WING NEEDED MODIFICATION PER EWA MA-AM-5732-04:00, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE. MODIFIED LWR WING SKIN AT STR 64 RT IAW EWA EO AM-5732-04:00.SDR RRXA001803Skin · damagedDURING A MAINTENANCE VISIT FOUND THAT THE LWR WING SKIN AT STR 64 LT WING NEEDED TO BE MODIFIED PER EWA MA-AM-5732-03:00, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE. COMPLIED WITH LOWER WING SKIN MODIFICATION STRINGER 64 IAW EWA EO AM-5732-03:0SDR RRXA000685Door Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO DOOR 62 DOOR JAMB L/H FWD CORNER AND R/H CENTER AREA, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIRED PART AND INSTALLED IAW DC-8 SRM 53-2-0.SDR RRXA002023Skin · gougedDURING A MAINTENANCE VISIT FOUND SEVERAL GOUGES AROUND OUTSIDE OF C-PIT DOOR (EXTERNAL), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 52-4-2 AND 51-1-21.SDR RRXA001959Structure · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN TWO PLACES AT SCREW HOLES ON THE LT CHIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0 AND EO NR 00-055.SDR RRXA001950Plate · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE TO THE B-PIT KICK PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND EO NR 00-055 WITH APPROVED 8110-3 DATED 4-4-0SDR RRXA001932Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND THE SCREW HOLES AT THE LT WING I/B LEADING EDGE UPPER SURFACE SKIN AT STA XFS 113.750 TO XFS 10.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8SDR RRXA001889Skin · gougedDURING A MAINTENANCE VISIT FOUND SEVERAL GOUGES TO THE C-PIT DOOR AROUND OUTSIDE OF DOOR (EXTERNAL), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 52-4-2 ASDR RRXA001824Structure · crackedDURING A MAINTENANCE VISIT FOUND CRACKS TO THE SCREW HOLES IN THE LT CHIN SCOOP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACKS AND INSTALLED SCOOP IAW DC-8 SRM 51-3-0.SDR RRXA001815Plate · gougedDURING A MAINTENANCE VISIT FOUND THE B-PIT KICK PLATE GOUGED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FORMED KICK PLATE BACK TO ORIGINAL CONTOUR, STOP DRILLED CRACK AND INSTALLED IAW DC-8 SRM 51-1-21 AND EOSDR RRXA001797Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AROUND SCREW HOLES AT LT WING I/B LEADING EDGE UPPER SURFACE AT STA XFS 113.750 TO XFS 10.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATEDSDR RRXA001781Skin · damagedDURING A MAINTENANCE VISIT FOUND THAT THE LWR. WING SKIN NEEDED TO BE MODIFIED AT STR. 64 RT. AND XRS 445, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. MODIFIED LWR. WING SKIN AT STR. 64 RT. IAW EWA E.O. AM-5SDR RRXA002025Skin · bulgedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE SKIN LOWER LOBE AT STA 360 & 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 ANSDR RRXA001997Frame · damagedDURING A MAINTENANCE VISIT FOUND A GIL LINER RIVET HOLE DRILLED IN RADIUS OF FRAME IN MAIN CABIN AT STA 1480, 8 INCHES UP FROM CUSP LINE L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED ANDSDR RRXA001986Frame · tool damageDURING A MAINTENANCE VISIT FOUND A DRILL START IN RADIUS OF FRAME & SHEAR FOOT AT STA 1480, 3 INCHES UP FROM CUSP L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW ESDR RRXA001967Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 898, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW CLIP IAW DC-8 SRM 5SDR RRXA001891Skin · bulgedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE SKIN LOWER LOBE AT STA 360 AND 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 SDR RRXA001862Frame · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED IN THE RADIUS OF FRAME MAIN CABIN GILL LINER AT STA 1480, 8 INCHES FROM CUSP LINE AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAI
Back to Douglas DC-8-73F