SDR RRXA001851Frame · tool damageDURING A MAINTENANCE VISIT FOUND A DRILL START IN RADIUS OF FRAME AND SHEAR FOOT AT STA 1480, 3 INCHES UP FROM CUSP L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DRILL START AND RETURNED Apr 4, 2000 · N961R · Doug DC873F · Fuselage Main, FrameSDR RRXA001832Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 898, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW CLIP IAW DC-8 SRM 5Apr 4, 2000 · N961R · Doug DC873F · Landing Gear DoorsSDR DHL200080477CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1.5 INCH AT STA 460.00 L-31 RT & LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLEApr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080475CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED .5 INCH AT STA 520.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080497CAngle · corrodedMAIN CARGO AFT SIDE FLOOR LWR PART SUPPORT ANGLE SHOWS CORROSION STA 1734 - 1732 BL 13 R (LEVEL 1). REMOVED CORRODED ANGLE PER SRM 51-3-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE PER SRM 51-1-21.Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080409CFloor Support · crackedMAIN CARGO COMPARTMENT 1B FLOOR CRACKED .75 INCH. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-3 FIG 10, 51-1-8.Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080408CFloor Support · crackedMAIN CARGO NR 1A FLOOR CRACKED. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-3 FIG 10, 51-1-8 PAGES 17 & 18.Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080407CFloor Support · crackedMAIN CARGO COMPARTMENT 1C FLOOR LWR ANGLE CRACKED 1 INCH. REMOVED AND REINSTALLED NEW ANGLE IAW SRM 51-1-21 PAGE 53, 51-2-0 PAGES 1 AND 2, 51-1-8 PAGES 17 & 18, 51-1-21 PAGE 53.Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080406CFloor Support · crackedMAIN CARGO COMPARTMENT 1C FLOOR CRACKED 1 INCH. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-3 FIG 10, 51-1-8 PAGE 17-18.Apr 4, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR UPS00832196Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED LIGHT BATTERY PACK PER MM 33-50-01Apr 4, 2000 · N814UP · Doug DC873F · Emergency LightingSDR RRXA001971Fitting · chafedDURING A MAINTENANCE VISIT FOUND A CHAFED CANOE FITTING ON THE LEFT I/B FLAP O/B FITTING AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-055 WITH APPApr 3, 2000 · N961R · Doug DC873F · Wing, Attach FittingsSDR RRXA001912Stringer · gougedDURING A MAINTENANCE VISIT FOUND GOUGED, CAN''T LWR STRINGERS 53 - 56 THROUGH ACCESS HOLE 505A NR 4 ALT TANK AT STA 485, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERApr 3, 2000 · N961R · Doug DC873F · Fuselage Main, Longeron/StringerSDR RRXA001911Fitting · chafedDURING A MAINTENANCE VISIT FOUND CHAFING IN 2 PLACES AT RT WING NR 4 FLAP CANOE FITTING LWR I/B SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED AREAS TO ALLOWABLE LIMITS AND RETURNED TO SERApr 3, 2000 · N961R · Doug DC873F · Wing, Attach FittingsSDR RRXA001904Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE RT SIDE OF THE TAIL CONE INSIDE AT STA 1953, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4 AND 51-1-2Apr 3, 2000 · N961R · Doug DC873F · Aerodynamic FairingsSDR RRXA001836Support Fitting · chafedDURING A MAINTENANCE VISIT FOUND CHAFED FITTING AT LT I/B FLAP CANOE FITTING O/B AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED AREA SMOOTH AND RETURNED TO SERVICE IAW EO NR 00-055 WIApr 3, 2000 · N961R · Doug DC873F · Trailing Edge FlapsSDR RRXA001776Stringer · gougedDURING A MAINTENANCE VISIT, FOUND A GOUGED THRU ACCESS HOLE 505A. NR 4 LT TANK LWR STRINGERS 53-56 AT STA 485, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8Apr 3, 2000 · N961R · Doug DC873F · Wing, Longeron/StringerSDR RRXA001775Fitting · chafedDURING A MAINTENANCE VISIT, FOUND A CHAFED CANOE FITTING ON THE LWR I/B SIDE OF THE RT WING NR 4 FLAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED AREAS SMOOTH AND RETURNED TO SERVICE IAWApr 3, 2000 · N961R · Doug DC873F · Wing, Attach FittingsSDR RRXA001768Frame · damagedDURING A MAINTENANCE VISIT, FOUND A HOLE TO THE RT. SIDE OF THE TAIL CONE INSIDE AT STA 1953, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8 FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21.Apr 3, 2000 · N961R · Doug DC873F · Aerodynamic FairingsSDR RRXA001750Skin · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK ON THE LWR SURFACE AT THE LT WING LE SKIN 5 INCHES FWD OF THE WING SPAR AT XFS 335, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAWApr 3, 2000 · N2674U · Doug DC873F · Leading Edge DevicesSDR RRXA001749Skin · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK ON THE AFT END OF THE CENTER WING BOX LWR SKIN EXTERIOR AT FS 855 AND BL 68R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8Apr 3, 2000 · N2674U · Doug DC873F · Fuselage Main, Plate/SkinSDR RRXA001748Angle · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK ON THE INBD DRAG ANGLE ON FOR NR 3 PYLON 1 INCH AFT WING SPAR AT XRS 198, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW DRAG ANGLE IAW DC-8 SApr 3, 2000 · N2674U · Doug DC873F · Nacelle/Pylon StructureSDR RRXA001747Floorboard · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK AT THE DRAIN PLUG HOLE ON THE MAIN CABIN FLOOR PANEL, AT BS 1200 AND RBL 10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SApr 3, 2000 · N2674U · Doug DC873F · Fuselage Floor PanelSDR RRXA001732Floorboard · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORBOARD, FS 987 TO 990 AND LBL 16 TO 19, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-Apr 3, 2000 · N2674U · Doug DC873F · Fuselage Floor PanelSDR RRXA001731Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN COURIER AREA FLOOR WEB AT FS 25 TO 45 AND LBL 48 TO 75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR WEBApr 3, 2000 · N2674U · Doug DC873F · Fuselage Floor PanelSDR RRXA000611Cargo Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION TO THE LT AFT CARGO TRACK AT STA 1020 TO 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC-8 SRM 51-3-0 AND 53-2-3 FIG 6N. (CORROSIONApr 3, 2000 · N831AL · Doug DC873F · Fuselage, Seat/Cargo Attach FittingsSDR DHL2000804132Fitting · crackedMAIN CARGO FITTING SPLICE BETWEEN NR 1 LONGERON AND BATH TUB FITTING CRACKED 5 INCHES AT STA 850 TO 852. REMOVED DAMAGED FITTING PER SRM 51-1-20. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW FITTING PER SRM 51-1-20.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080479CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AND .5 INCH AT STA 400.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080478CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS CRACKS OF 1 INCH AND .5 INCH AT STA 420.00 L-30 AND L-29 RT & LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080476CAngle · crackedFWD BAGGAGE COMPT FRAME REINFOCING ANGLE CRACKED 1 INCH AT STA 480.00 L31 RT & LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080474CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 500.00 L-33 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080496CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 2 INCHES AT STA 200.00 FROM L35 TO L36 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080495CRib · crackedRIGHT MLG W/W LOWER PART RIGHT SIDE RIB CRACKED 1 INCH AT STA 874.000. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-0.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080480CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS 2 CRACKS OF 1 INCH AT STA 400.00 L-34 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL2000804102Angle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 120.00 L-31RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL2000804100Angle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER WITH NEW FASTEApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080450CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 580.00 L-35 RT. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080449CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 580.00 L-35 RT. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080447CIntercostal · crackedMAIN CARGO INTERCOSTAL SUPPORT CRACKED .5 INCH AT STA 700.00 TO STA 705.00 NEAR LONGERON SLH. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-0.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080440CPanel · crackedRIGHT MLG ACCESS PANEL CRACKED 1.5 INCH AT STA 890.00. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-0.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080452CAngle · crackedFWD BAGGAGE COMPT FRAME REINFOCING ANGLE CRACKED AT STA 140.00 L35-36 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 51-1-21.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080451CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 51-1-21.Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL2000804125Angle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-33 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREA PER SRM 51-1-8. INSTALLED NEW ANGApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL2000804124Angle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS 4 CRACKS OF 1 INCH AT STA 380.0 L29, L30, L31, RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER AND SPLICES PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREAS PER SRApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL2000804123Angle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED NEAR L-31 LT STA 600.000. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW DOUBLER PER SRM Apr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080473CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 500.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080472CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 480.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080471CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 380.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080470CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080469CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100 L-33 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASTENApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous StructureSDR DHL200080468CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 120.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREA PER SRM 51-1-8. INSTALLED DOUBLER WITApr 3, 2000 · N804DH · Doug DC873F · Fuselage Miscellaneous Structure
Back to Douglas DC-8-73F