Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL200080324CFloor Support · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 6 INCHES AT STA 1380.000 FROM L34 TO L36 RT. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED DOUBLER ON FLOOR SUPPORT WITH FASTENERS AND RIVETS IAW SRM 53-2-0 PAGE 10 TO 12SDR DHL200080322CFloor Support · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 2 INCHES AT STA 1360.00 L-33 RT. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED FLOOR SUPPORT DOUBLER WITH FASTENERS AND SOLID RIVETS IAW SRM 53-2-0 PAGE 10 TO PAGE 12 FIGSDR DHL200080312CFloor Support · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 1360.000 L-35R. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER. INSTALLED FLOOR DOUBLER WITH FASTENERS AND RIVETS IAW SRM 53-2-0 PG 12 2BA AND 2B. WORK DONE ON NONE ROUTSDR DHL200080382CSkin · dentedAT C-CHECK, RT WING I/B FLAP UPPER SKIN SHOWS SEVERAL DENTS AROUND WING STATION XW 65.0 TO XW 35.0. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR DOUBLER IAW EO NR DHL011801. N/R 1283SDR DHL200080361CAngle · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 8 INCHES AT STA 1300 FROM L30 TO L32 LT. FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 3A AND FIG 2B. N/R 5573SDR DHL200080339CSkin · deformedAT C-CHECK, LT WING AILERON T/E UPPER SKIN DEFORMED AT XW 627. REMOVED FASTENERS AND PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-8, PG 11, INSTALLED SKIN IAW SRM 51-1-21 PG 7. N/R 1078SDR DHL200080316CFloor Support · crackedAT C-CHECK, AFT FWD LOWER CARGO COMPARTMENT FLOOR SUPPORT FLANGE CRACKED 1 INCH AT STA 520.00 CLOSE TO L-31. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED FLOOR SUPPORT DOUBLER WITH FASTENERS AND SOLID RIVETS IAW SRM 53-2-0 PAGE 10 TOSDR DHL200080315CFloor Support · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 6 INCHES AT STA 1230.000 FROM L34 TO L36. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED FLOOR SUPPORT DOUBLER WITH FASTENERS AND SOLID RIVETS IAW SRM 53-2-0 PAGE 10-12 FISDR DHL200080309CRib · crackedAT C-CHECK, RT WING L/E NR 522B ACCESS PANEL SHOWS RIB CRACKED 3 INCHES AT STA XFS 347.730. FABRICATED DOUBLER IAW SRM 57-2-0 (2024730.63A6). TREATED AND PRIMED IAW SRM 51-1-2B/P6 344. INSTALLED DOUBLER WITH FASTENERS IAW SRM 51-1-200 PG 69. WORK DONE ON NSDR RRXA000554Seat Track · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO MAIN DECK SECTION OF SEAT TRACK BETWEEN STA 130 TO 270 RBL 45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED MAIN DECK SECTION OF SEAT TRACK AND INSDR RRXA000497Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT STA 9 AND BL 24 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3 FIGURE 8A. CORROSION DASDR DHL200080304CSkin · crackedAT C-CHECK, FUSELAGE EXTERIOR ACCESS DOOR CORNER CRACKED 4 INCHES AT FS 37, AT L-39 AND L-40. INSTALLED DOUBLER PER SRM 53-2-0.SDR UPS00831394Battery Pack · dischargedEMERGENCY EXIT LIGHTS INOP. ON PRE-FLIGHT CK, REMOVED AND REPLACED EMERGENCY BATTERY PACK. SYSTEM OPS CK GOOD.SDR DHL200080302CSkin · dentedAT C-CHECK, LEFT WING OUTBD FLAP T/E UPPER PART DENTED AT XW 217.815. FABRICATED AND INSTALLED PER SRM 57-2-1.SDR DHL200080301CFloor Support · crackedAT C CHECK, AFT BAGGAGE COMPT, FLOOR SUPPORT ANGLE CRACKED 3 INCHES AT STA 1280 FROM L 35 TO L 34. REPAIRED FLOOR SUPPORT PER SRM 53-2-0. N/R 5577.SDR DHL200080365CAccess Door · crackedAT C-CHECK, COCKPIT ELECTRONICS COMPARTMENT NR 617E ACCESS DOOR RT L-4 UPPER AND LOWER EDGE CRACKED 1 INCH. STOP DRILLED CRACK IAW SRM 53-2-0 PG 7, FABRICATED AND INSTALLED DOUBLER IAW SRM 51-1-21 PG 7. N/R 4297SDR DHL20008362CSkin · dentedAT C-CHECK, LEFT C/B FLAP TRAILING EDGE UPPER PART DENTED .5 INCH AT XW 454. REMOVED O/B FLAP T/E, FABRICATED AND INSTALLED O/B FLAP T/E IAW SRM 57-2-1 PG 28, FIG 25. N/R 1088SDR DHL200080357CWeb · crackedAT C-CHECK, MAIN CARGO COMPARTMENT CUSP WEB SKIN LT SIDE CRACKED 1.5 INCH BETWEEN FS 1540 AND FS 1560. REMOVED TRACK AS REQUIRED, FABRICATED AND INSTALLED DOUBLER IAW SRM 51-1-21 PG 6, REINSTALLED TRACK IAW SRM 51-3-0 PG 1 & 2. N/R 5221SDR DHL200080353CChannel · crackedAT C-CHECK, AFT FWD CARGO COMPARTMENT MAIN CARGO FLOOR LOWER SKIN SUPPORT ''U'' ANGLE CRACKED 1 INCH AT FS 640 BL 20 LT. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 AND 51-1-21. N/R 5370SDR DHL200080349CFloor Support · crackedAT C-CK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA 1440, L-36. REMOVED AFFECTED AREA, FABRICATED AND INSTALLED SUPPORT ANGLE IAW SRM 51-1-8, PG 27. N/R 5617SDR DHL200080348CSkin · crackedAT C-CHECK, FWD BAGGAGE COMPARTMENT LT TUNNEL SKIN BETWEEN BEAM CRACKED 1 INCH FROM STA 120 TO STA 140. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0, PG 2K. N/R 5101SDR DHL200080342CStructure · crackedAT C-CHECK, FWD CARGO COMPARTMENT NR 636 ACCESS DOOR CRACKED 1 X 1 INCH AT FS 70.00. FABRICATED AND INSTALLED DOUBLER IAW SRM 51-1-19 PG 3 & 4, FIG 19. N/R 5368SDR DHL200080340CFloor Support · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FLOOR SUPPORT ANGLE CRACKED AT STA 1360 L-33 RT. REMOVED AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED ON FLOOR SUPPORT ANGLE IAW SRM 53-2-0 PG 10 TO PG 12 FIG 2A AND 2B. N/R 5585SDR DHL200080237CAngle · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT, FLOOR SUPPORT ANGLE CRACKED 6 INCHES AT STA 1300 FROM L-34 TO L-36. REMOVED AFFECTED AREA, FABRICATED AND INSTALLED DOUBLER ON FLOOR SUPPORT ANGLE IAW SRM 53-2-0 PG 10-12, FIG 2A AND 2B. REF: N/R 5580.SDR DHL200080336CShear Tie · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT SKIN FRAME ATTACH ANGLE CRACKED 3 INCHES STA 1380 L-31 TO L-32. FABRICATED DOUBLER IAW SRM 53-2-0, INSTALLED DOUBLER IAW 51-1-21 PG 7, FIG 33B. N/R 5610SDR DHL200080332CSkin · crackedAT C-CHECK, FWD CARGO COMPT NR 630 ACCESS DOOR SKIN CRACKED 1 INCH. STOP DRILLED, INSTALLED DOUBLER PER SRM 52-2-0. N/R 6025SDR DHL200080323CFloor Support · crackedAT C-CHECK, AFT FWD LOWER CARGO COMPARTMENT FLOOR SUPPORT ANGLE CRACKED .5 INCH AT STA 500.00 CLOSE TO L31R. REMOVED FASTENERS FROM AFFECTED AREA, FABRICATED DOUBLER AND INSTALLED FLOOR SUPPORT DOUBLER WITH FASTENERS AND SOLID RIVETS IAW SRM 53-2-0 PG 10-12 FSDR RRXA001036Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RIGHT WING, FLAP EXTERNAL SKIN BETWEEN XW 2 TO XW 64. CORROSION DAMAGE BEYOND LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-7-SDR DHL200080314CAngle · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT SUPPORT ANGLE CRACKED 1 INCH AT STA 1400.000 L-35 LT. REMOVED DAMAGED AREA AND FASTENERS IAW SRM 53-2-0 PG 10. FABRICATED SUPPORT WITH SOLID RIVETS IAW SRM 51-1-21 PAGE 3-4 FIG 32 AND PAGE 7 FIG 33.SDR RRXA000496Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ATTACHMENT ANGLE AT STA 35 AND LONGERON 31 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ATTACHMENT ANGLE IAW DAC DWG 2643SDR RRXA000495Attach Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FRAME ATTACHMENT ANGLE AT STA 55 AND LONGERON 31 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ATTACHMENT ANGLE IAW DAC DWSDR DHL200080394CSkin · crackedAT C-CHECK, FWD CARGO COMP NR 636 ACCESS DOOR SKIN SHOWS CRACK 3 INCHES AT FS 70. PERFORMED STOP DRILL AND FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 7. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8 PAGE 11 & 12. INSTALLED DOUBLER WITH SOLID RIVETS ON FWD CARGO ACSDR DHL2000803116Seat Track · deterioratedAT C-CHECK, MAIN CARGO NR 3 LT SEAT TRACK FLANGE DETERIORATED BETWEEN FS 640 AND FS 700. REMOVED AND REPLACED TRACK AND FLANGE IAW SRM 53-2-3 PG 49 & 50. REF: N/R 5195.SDR DHL2000803115Floor Support · crackedAT C-CHECK, FWD LWR CARGO FLOOR SUPPORT FLANGE CRACKED .5 INCH STA 120 BETWEEN LONGERON 31 AND 32. REMOVED AFFECTED AREA, FABRICATED AND INSTALLED DOUBLER IAW SRM 51-3-0 PG 7. REF: N/R 5195.SDR DHL2000803110Strap · deterioratedAT C-CHECK, AFT FWD LOWER CARGO FLOOR SUPPORT STRAP DETERIORATED FROM STA 560 TO STA 580, CLOSE TO L-31RH. FABRICATED AND INSTALLED NEW SUPPORT STRAP IAW SRM 53-2-0, PG 10 TO 12. REF: N/R 5404.SDR DHL2000803109Angle · crackedAT C-CHECK, FWD LOWER CARGO FLOOR SUPPORT ANGLE SHOWS CORROSION LEVEL 1 AND CRACK OF .25 INCH STA 140 ABOUT LONGERON 3L. PERFORMED CORROSION TREATMENT IAW SRM 51-1-8 PG 4, FABRICATED AND INSTALLED DOUBLER IAW SRM 51-1-20 PG 9. REF: N/R 5391.SDR RRXA000104Vane · damagedDURING A MAINTENANCE VISIT FOUND SCREW HOLE ELONGATED, LT I/B FLAP NR 1 SCREW HOLE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM.. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000103Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION, LEFT WING, LWR SURFACE T/E PANEL UNDER I/B FLAP O/B HINGE FWD FAIRING AT STA XW 106. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000102Link · gougedDURING A MAINTENANCE VISIT FOUND GOUGE, LEFT WING, O/B FLAP AT STA 219 PORK CHOP GOUGE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000101Panel · dentedDURING A MAINTENANCE VISIT FOUND LOW SPOT, LEFT WING, TANK ACCESS PANEL 505C HAS LOW SPOT APPROX 1/2 IN DIAMETER NEEDS THICKNESS CHECK.SDR RRXA000100Doubler · damagedDURING A MAINTENANCE VISIT FOUND HOLE IN DOUBLER, NR 2 ENGINE INTERIOR OR RT FAN REVERSER DOUBLER HAS HOLE DAMAGE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000099Fan Reverser · crackedDURING A MAINTENANCE VISIT FOUND CRACK, FAN REVERSER, NR 2 ENGINE INTERIOR OF RT FAN REVERSER CRACK IN SECOND FROM TOP LAP JOINT AFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000098Bracket · crackedDURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, STRUCTURE CRACKED BRACKET AT STA 1690 LT AT LONGERON 11 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR DHL20080394CSkin · crackedAT C-CHECK, FWD CARGO COMP NR 636 ACCESS DOOR SKIN SHOWS CRACK 3 INCHES AT FS 70. PERFORMED STOP DRILL AND FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 7. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8 PAGE 11 & 12. INSTALLED DOUBLER WITH SOLID RIVETS ON FWD CARGO ACSDR DHL2000803100Angle · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI CORROSIVE TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLERSDR DHL200080399CAngle · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLERSDR DHL200080398CDoor Frame · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLERSDR DHL200080397CDoor Frame · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI-CORROSIVE TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLERSDR DHL200080396CDoor Frame · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI-CORROSIVE TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLERSDR DHL200080395CDoor Frame · crackedAFT FWD LOWER CARGO LT NR 2 AFT DOOR FRAME PROTECTIVE ANGLE CRACKED. REMOVED DAMAGED AREA AND PERFORMED ANTI-CORROSIVE TREATMENT IAW SRM 51-1-8 PAGE 11. FABRICATED DOUBLER IAW SRM 52-2-0 PAGE 13. TREATED AND PRIMED IAW SRM 51-1-8 PAGE 12. INSTALLED DOUBLER
Back to Douglas DC-8-73F