Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS99830095Seat Track · gougedINSPECTION TYPE:C2 MAIN CABIN SEAT TRACK I IS GOUGED AT STA 255. FABRICATED AND INSTALLED PLUG AND CHANNEL IAW DC8 SRM 53-2-3 AND 51-3-0.SDR UPS99830094Seat Track · crackedINSPECTION TYPE:C2 STA 1400 TRACK I SCALLOPS GOUGED. FABRICATED AND INSTALLED NEW SECTION OF CARGO TRACK IAW 51-1-20D, 51-3-0, 53-2-3. MAT ID FOR NEW SECTION OF CARGO TRACK S2772660-13500N, SPO429308.SDR UPS99830068Seat Track · corrodedINSPECTION TYPE:C2, MAIN CABIN SEAT TRACK WAS GOUGED AND CORRODED AT STA 270. REMOVED AND INSTALLED NEW PLUG (P/N DC8 53B-007-004) IAW DC8 SRM 53-2- 3, UPS PARTS TAG NR 942460 (S/N 00290311).SDR RRXA991171Transceiver · failedWX RADAR FAILED IN FLT. REPLACED XCVR AND RADAR SCOPE, OPS CHECKS GOOD ON GROUND, NO DEFECTS NOTED AT THIS TIME.SDR UPS99830200Doubler · crackedINSPECTION TYPE:C123, RT WING L/E AT XFS 597.5, THE SKIN INTERNAL DOUBLER IS CRACKED AT THE DRAIN HOLE. REMOVED, FABRICATED, AND REPLACED THE DOUBLER IAW DWG 5769600 AND SRM 51-1-21.SDR UPS99830198Doubler · corrodedINSPECTION TYPE:C123, SEVERAL POPPED RIVETS AND BULGING IN FINGER DOUBLER, FS 5, LBL 65. REMOVED, FABRICATED, AND REPLACED FINGER DOUBLER IAW SRM 53-3-3 FIG 6 AND 51-1-21.SDR UPS99830197Doubler · crackedINSPECTION TYPE:C123, NR 3 MAIN TANK INBD AFT ACCESS PANEL LAND IS CRACKED AT 2 FASTENER HOLES, (ACCESS PANEL 505F). CUT OUT DAMAGED AREA AND REPAIRED IAW SRM 57-2-1 FIG 36.SDR UPS99830161Support · corrodedINSPECTION TYPE:C2, C-PIT STA 1160 FLOORBEAM SUPPORT EXFOLIATED L27L. FABRICATED AND INSTALLED NEW FLOORBEAM SUPPORT AND SHIM IAW REO NR 06609 AND DC8 SRM 51-1-20D.SDR UPS99830145Door Track · corrodedINSPECTION TYPE:C2, AFT CARGO PIT CORROSION ON I/B AND O/B FACES OF INTERCOSTAL IN 'C' PIT DOOR TORQUE OBX STA 1200-1210 L29R. FABRICATED AND INSTALLED DOOR TRACK IAW DC8 SRM 51-3-8 DAC DWG 9754947.SDR UPS99830093Fuselage · corrodedINSPECTION TYPE:C2 AFT CARGO PIT STA 1300 6 EA FLOORBOARD SPLICES CORRODED X-38 TO X-20 FABBED AND INSTALLED NEW SPLICES IAW DC8 SRM 58-1-20 AND DC8 SRM 53-2-3.SDR UPS99830067Web · crackedINSPECTION TYPE:C2, FS 857 LOWER WEB HAS CRACK AT NUT PLATE ON LOWER RIGHT ACCESS PANEL. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLER AND FILLER ALODINED AND PRIMED AREA.SDR UPS99830066Web · crackedINSPECTION TYPE:C2, FS 857 LOWER WEB HAS CRACK AT NUT PLATE ON LOWER LEFT ACCESS PANEL. FABBED REPAIR IAW DC8 SRM 53-2-0. REPAIRED IAW DC8 SRM 51-1-21 AND 51-1-8.SDR UPS99830065Frame · corrodedINSPECTION TYPE:C2, AFT CARGO PIT CORROSION EMINATING FROM JOINT AT INTERCOSTAL ATTACH CLIP AND FRAME, STA 1260 LONG 35R. REMOVED LITE CORROSION, ALODINED AND PRIMED IAW DC8-SRM 51-1-8.SDR RRXA991480Frame · damagedDURING A MAINTENANCE VISIT FOUND MAIN CARGO DOOR UPPER JAM SKIN SECTION DAMAGED BETWEEN STA 151 AND STA 177 LT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLERS AND DOUBLERS IAW FAA APSDR UPS99830196Rib · crackedINSPECTION TYPE:C123, LT HORIZ STAB L/E RIB AT XFS 141.25 IS CRACKED AT THE AFT LOWER END. STOP DRILLED CRACK AND REPAIRED IAW SRM 55-2-0 FIG 2.SDR UPS99830195Fitting · crackedINSPECTION TYPE:C123, FWD SIDE OF THE FS 781 FRAME, AT LONGERON 18R, THE INTERCOSTAL ATTACH FITTING IS CRACKED. REMOVED AND REPLACED THE FITTING IAW SRM 51-1-20D.SDR UPS99830194Angle · crackedINSPECTION TYPE:C123, ANGLE CRACKED, LT SIDE LWR CENTER WING AT FS 760, XCW 69. REMOVED, FABRICATED, AND REPLACED ANGLE IAW DWG 5649893 AND SRM 51-1-20D.SDR UPS99830193Longeron · corrodedINSPECTION TYPE:C123, LONGERON 32L AT FS 1225 HAS HEAVY CORROSION. REPAIRED IAW EO DC8-5310-11651A AND DH SK874-683.SDR UPS99830150Hinge · crackedINSPECTION TYPE:C2, LT OUTBOARD FLAP 339 FLAP HINGE SUPPORT FITTING CRACKED. REMOVED AND REPLACED FLAP HINGE FITTING SUPPORT IAW S/B 27-249.SDR UPS99830127Doubler · crackedINSPECTION TYPE:C2 D CARGO PIT DOOR EXTERIOR SKIN HAS .75 INCH VISIBLE CRACK 12 INCHES ABOVE LOWER AFT CORNER. FABBED AND INSTALLED DOUBLER IAW DC8 SRM 52-2-0, 51-1-21, 51-1-20 & 51-1-15.SDR RRXA991428Support · brokenDURING A MAINTENANCE VISIT, FOUND LEFT WING O/B SLOT DOOR SUPPORT PREVIOUS REPAIR SUPPOT BROKEN AND CORRODED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC8 SRM 57-23-1, 51-1-SDR RRXA991420Panel · crackedDURING A MAINTENANCE VISIT, FOUND AFT LOWER CARGO COMPT BULKHEAD BETWEEN PIT CENTER PANEL NEEDS REPAIR CRACKED AT STA 1340. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PARTITION IAW DASDR RRXA991417Fairing · crackedDURING A MAINTENANCE VISIT, FOUND CABIN AT STA 1688 RT FAIRING (SHROUD) CRACKED AND BROKEN, CARGO CONFIGURATION. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FAIRING IAW FAA APPROVED TSDR RRXA991416Fairing · crackedDURING A MAINTENANCE VISIT FOUND CABIN AT STA 1688 LT FAIRING (SHROUD) CRACKED, CARGO CONFIGURATION. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FAIRING IAW FAA APPROVED TENNESSEE TECHSDR RRXA991415Skin · misrepairedDURING A MAINTENANCE VISIT, FOUND LEFT WING LEFT HAND NR 2 FLAP WEDGE PREVIOUS REPAIR IMPROPER BETWEEN STA XW 101 AND XW 115. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SKIN IAW FAA ASDR RRXA991400Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BLISTER ON FRAME 70, BETWEEN LONGERONS 33 RIGHT AND LONGERON 32 RIGHT.. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW FAA ASDR RRXA991399Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FRAME CAP AT STA 1100 BETWEEN LONGERONS 35 LEFT AND LONGERON 35 RIGHT.. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLERS AND DOUBLESDR RRXA991381Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, AFT LOWER CARGO COMPARTMENT AT STA 1320, BL 55 RIGHT, FLOOR PANEL AND SUPPORT BEAM. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIRSDR RRAX000001Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=880 TO Y=900. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGSDR UPS99830191Fitting · corrodedINSPECTION TYPE:C123, LONGERON 30R AT FS 72 HAS MODERATE CORROSION. REMOVED AND REPLACED THE FITTING IAW SRM 51-1-20D AND 51-3-0.SDR UPS99830190Longeron · crackedINSPECTION TYPE:C123, FS 894, LONGERON 24R IS CRACKED. REPAIRED LONGERON IAW DH SK874-640.SDR UPS99830189Fitting · crackedINSPECTION TYPE:C123, FLOORBEAM ATTACH FITTING AT FS 280, RBL 57, IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D AND 51-3-0.SDR UPS99830188Fitting · crackedINSPECTION TYPE:C123, FS 1160, BETWEEN LONGERON 34R AND 33R, THE BATHTUB FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 53-2-0 FIG 2D.SDR UPS99830187Fitting · crackedINSPECTION TYPE:C123, FLOORBEAM ATTACH FITTING IS CRACKED AT FS 980 BULKHEAD AT LBL 24. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 3751514 AND SRM 51-1-20D.SDR UPS99830186Frame · crackedINSPECTION TYPE:C123, FS 55 FRAME AT LONGERON 24R IS CRACKED AT THE DUCT SUPPORT BRACKET. CUT OUT DAMAGED SECTION AND REPAIRED IAW SRM 53-2-0 FIG 2.SDR UPS99830185Frame · crackedINSPECTION TYPE:C123, FS 55 FRAME AT LONGERON 24L IS CRACKED AT THE DUCT SUPPORT BRACKET. CUT OUT DAMAGED SECTION AND REPAIRED FRAME IAW SRM 53-2-0 FIG 2.SDR UPS99830162Angle · corrodedINSPECTION TYPE:C2, C-PIT GILLINER SUPPORT ANGLE CORRODED STA 1160 LONG 26L-27L. FABRICATED AND INSTALLED WEB, DOUBLER, FILLER IAW DC8 SRM 51-1-20D, 51 -1-21 DAC DWG 9751879 AND EO DC8 5350-7876.SDR UPS99830151Seat Track · corrodedINSPECTION TYPE:C2, CARGO PIT CORROSION ON BOTTOM SIDE OF MAIN CABIN FLOORBOARD AND SEAT TRACK STA 1000-1100 X3 TO -3. FABRICATED AND INSTALLED FLOOR PANELS IAW DC8 SRM 51-1-8 & 51-3-0, 53- 2-3 AND ADDENDUM DC8-53B-003.SDR UPS99830147Stantion · corrodedINSPECTION TYPE:C2, LT FLOORBEAM SUPPORT STA 1180 CORRODED 12 INCHES ABOVE LONG 27L. REMOVED STANTION, LOCATED DRILLED AND DEBURRED NEW STANTION. INSTALL ED NEW STANTION IAW UPS DC8 SRM 51-1-20D.SDR UPS99830146Shear Tie · crackedINSPECTION TYPE:C2, SHEAR THE CRACKED STA 1160 LONG 26L-27L INSIDE C-PIT DOOR TORQUE BOX. FABRICATED AND INSTALLED NEW SHEAR TIE SECTION IAW DAC DWG NR 9754002 & DC8 SRM 51-1-20D, 53-2-0 FIG 2B.SDR UPS99830089Support · corrodedINSPECTION TYPE:C2 C CARGO PIT RT TUNNEL STA 1120 FLOORBEAM SUPPORT CORRODED AT NUTPLATE 6 ABOVE LONG 27R. FABRICATED AND INSTALLED NEW STRUT IAW DC8 SRM 51-3-2 AND 51-1-20.SDR UPS99830088Doubler · crackedINSPECTION TYPE:C2 R/W L/E DOUBLER CRACKED JUST ABOVE NR 4 PYLON. FABRICATED AND INSTALLED NEW DOUBLER IAW DC8 SRM 57-2-1A AND 51-1-20D.SDR RRXA991748Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=1580 TO Y=1680 AND X=-24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991740Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-1 BETWEEN Y=1000 TO Y=1300 AND X=20. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR RRXA991734Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=1000 TO Y=1300 AND X=40. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991733Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-2 BETWEEN Y=1000 TO Y=1300 AND X=40. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR RRXA991730Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=880 TO Y=1000 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR RRXA991727Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=580 TO Y=880. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGISDR RRXA991722Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-1 BETWEEN Y=1580 TO Y=1680 AND X=-5. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR RRXA991718Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=1357 TO Y=1360 AND BETWEEN X=0 TO X=-8. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER
Back to Douglas DC-8-73F