Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS99828683Intercostal · corrodedINSPECTION TYPE:D MAIN CABIN, CORROSION ON INSIDE OF UPPER LIP ON LONG 12R STA 781-798. REMOVED CORROSION INTERCOSTAL AND REPLACED WITH NEW INTERCOSTAL.SDR UPS99828681Fitting · crackedINSPECTION TYPE:D, AFT PIT LT TUNNEL FS 1220 AT L27L INSIDE TQ BOX HAS CRACKED FITTING. REMOVED DAMAGED FRAME SECTION FAB REPLACEMENT FRAME PER DAC DWG 9754 921. INSTALLED PER DC8 SRM 51-1-20D.SDR DHL9980548CAngle · crackedAT C-CHECK, RT WHEEL WELL TOP CEILING STA 860 HAS CRACKED ANGLE. REMOVED DAMAGED ANGLE, FABRICATED NEW ANGLE 31.25 X 1.75 X 2.25, INSTALLED PER SRM 51-1-21. N/R 323SDR DHL9980516CFloor · crackedAT C-CHECK, MCC FLOOR PANEL STA 1746 BOTTOM CHANNEL IS DETERIORATED AND HOLE CRACKED. FABRICATED DOUBLER REPAIR PER SRM 53-2-0 AND INSTALLED PER SRM 51-1-21. N/R 947SDR UPS99828694Fitting · crackedINSPECTION TYPE:D, AFT ACC STA 1690 L22R END FITTING CRACKED. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-21 AND 51-1-20D.SDR UPS99828690Intercostal · corrodedINSPECTION TYPE:D, MAIN CABIN CORROSION ON LONGERON 19R INTERCOSTAL STA 680-702. REPLACED CORROSION INTERCOSTAL WITH NEW INTERCOSTAL.SDR UPS99828659Angle · crackedINSPECTION TYPE-C123, LT WING LOWER LEADING EDGE I/B STA XWO ANGLE CRACKED AT O/B END OF ANGLE. FAB DOUBLER IAW 57-2-0. ALODINED AND PRIMED IAW DC8 SRM 51-1-21. INSTALLED DOUBLERS IAW DC8 SRM 51-1-20D.SDR DHL9980504CBracket · crackedAT C-CHECK, O/B FLAP HINGE SUPPORT BRACKET XW 410 HAS CRACK. REMOVED, FABRICATED AND INSTALLED SUPPORT BRACKET PER SRM 51-1-21, 2 X 6 N/R 1204.SDR UPS99828698Skin · corrodedINSPECTION TYPE:D, RT CENTER TAIL CONE SKIN STA 1916-1951 IS CORRODED. FAB NEW SKIN IAW DC8 DAC DWG 5644500 ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED IAW DC8 SRM 51-1-21.SDR UPS99828697Skin · corrodedINSPECTION TYPE:D, LT CENTER TAIL CONE SKIN STA 1916-1951 IS CORRODED. FAB NEW SKIN IAW DC8 DWG 5644500 ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED IAW DC8 SRM 51-1-21.SDR UPS99828696Skin · corrodedINSPECTION TYPE:D, RT MOST FWD TAIL CONE SKIN STA 1890-1916 IS CORRODED. FAB NEW SKIN IAW DAC DWG 5644500 ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED IAW DC8 SRM 51-1-21.SDR UPS99828695Skin · corrodedINSPECTION TYPE:D, LT MOST FWD TAIL CONE SKIN STA 1890-1916 IS CORRODED. FAB NEW SKIN IAW DAC DW3G 5644500 ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED IAW DC8 SRM 51-1-21.SDR UPS99828665Frame · corrodedINSPECTION TYPE-C123, FRAME AT STA 1889 IS CORRODED AND HAS DOUBLE DRILLED HOLES. REMOVED PREVIOUS CAP FRAME AND SPLICE ANGLES. GEN REO FOR REPAIR INFO. FABRICATED NEW FRAME SECTION AND 4 SPLICE ANGLES. ALODINED AND PRIMED REPAIR PARTS. INSTALLED REPAIR PSDR UPS99828597Fairing · crackedINSPECTION TYPE-123D, LT ELEVATOR T/E STA XE117 FAIRING ATTACH HOLE CRACKED. REPAIRED AREA IAW DC8 SRM 55-2-0. ALODINED AND PRIMED IAW DC8 SRM 51-1-8.SDR UPS99828594Fitting · crackedINSPECTION TYPE-123D, MAIN CABIN LONG 6L END FITTING CRACKED FWD SIDE OF STA 857 FRAME. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D.SDR UPS99828593Fitting · crackedINSPECTION TYPE-123D, MAIN CABIN LONG 6R END FITTING CRACKED FWD SIDE OF STA 857 FRAME. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D.SDR UPS99828591Fitting · crackedINSPECTION TYPE-123D, MAIN CABIN LONG 10R END FITTING CRACKED FWD SIDE OF STA 680 FRAME. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D.SDR UPS99828590Fitting · crackedINSPECTION TYPE-123D, MAIN CABIN LONG END FITTING FWD SIDE OF STA 680 FRAME. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D.SDR UPS99828588Fitting · crackedINSPECTION TYPE-123D, MAIN CABIN, LONG 3L END FITTING CRACKED FWD SIDE OF STA 680. REMOVED AND REPLACED END FITTING IAW DC8 SRM 51-1-20D.SDR DHL9980537CSkin · damagedAT C-CHECK, LEFT WING T/E TEMP REPAIR AROUND GEAR DOWN IND. REMOVED REPAIR, FABRICATED REPAIR DOUBLER PER SRM 51-1-9, 4 X 6.5 X .25. N/R 796SDR UPS99828660Fitting · crackedINSPECTION TYPE-C123, AFT PIT STA 1135 L23R Z-FITTING CRACKED. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D.SDR UPS99828701Bracket · corrodedINSPECTION TYPE:D, CORROSION BEHIND EMERGENCY STRAP BRACKET, LT OVERWING ENTRY. REMOVED BRACKET, FABBED NEW ONE IAW DAC DWG 5779947 AND REO 06168. INSTALLED IAW DAC DWG 5779947.SDR UPS99828699Bracket · corrodedINSPECTION TYPE:D, CORROSION BEHIND EMERGENCY STRAP BRACKET LT OVERWING ENTRY. REMOVED CORROSION BRACKET AND INSTALLED NEW BRACKET. REMOVED CORROSION OUT OF LIMITS AFT BLEND. GEN RFTS, MAT ID 7075T6.063. OK TO FAB. FABBED, OK TO ALODINE AND PRIME. ALODINSDR DHL9980521CStrap · crackedAT C-CHECK, FED AFT CLOWER CARGO COMPT STA 1140 LONGERON 31R FLOOR STRAP CRACKED. STOP DRILLED CRACK, FABRICATED AND INSTALLED REPAIR DOUBLER 3 X 2. INSTALLED DOUBLER PER SRM 51-1-21. N/R 868SDR DHL9980520CStrap · brokenAT C-CHECK, FWD AFT LOWER CARGO COMPT BETWEEN STA 1160 TO 1200 FLOOR STRAP BROKEN. FABRICATED AND INSTALLED REPAIR SPLICE 4 X 1.5' PER SRM 53-2-0. N/R 867SDR DHL9980513CSkin · crackedAT C-CHECK, ON EMPENNAGE LEFT SIDE AT STA 1746 ZT 32 A CRACK ONE INCH LONG. CUT OUT CRACKED SECTION OF SKIN AND FABRICATED REPAIR DOUBLER PER SRM 51-1-8, 12 X 10. N/R 1045SDR UPS99828727Fitting · leakingINSPECTION TYPE-C123, LT HAND SKI FITTING IN CTR TANK LEAKING FUEL. REMOVED AND REPLACED SKI FITTING IAW REO-06186.SDR UPS99828662Frame · crackedINSPECTION TYPE-C123, STA 160R SIDE FRAME BOTTOM IS CRACKED. REPLACED DAMAGED SECTION OF FRAME.SDR DHL9980562CSkin · dentedAT C-CHECK, FS 1680 LT SIDE HAS DENT OUT OF LIMITS. CUT OUT DAMAGED AREA AND FABRICATED REPAIR DOUBLER 10 X 12, FILLER 12 X 4 PER SRM 53-2-1. N/R 271SDR UPS99828595Skin · damagedINSPECTION TYPE-123D, FUSELAGE SKIN REPLACEMENT NEEDS REPAIR SPLICES BOTH SIDE (LT& RT). CUT SKIN PANEL 5750365 (AT APPROX 690), FABRICATED REPAIR SPLICE LONG ERON STRAPS INTERNAL AND EXTERNAL DOUBLER WITH FINGER DOUBLER IAW DC8 SRM 53-2-1 AND REO 06044.SDR DHL9980519CStrap · crackedAT C-CHECK, FWD OF AFT CARGO COMPT TOP OF LONGERON 35R AND ON CIRFUMFERENTIAL 1140 FLOOR STRAP CRACKED. REMOVED DAMAGED FLOOR STRAP, FABRICATED AND INSTALLED NEW STRAP PER SRM 51-1-21. N/R 871SDR UPS99828700Skin · dentedINSPECTION TYPE:D, SKIN FWD OF TAIL CONE AT STA 1885 IS BULGED AND DENTED. FAB NEW SKIN SECTION IAW DAC 5644500 ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALL IAW DC8 SRM 51-1-21.SDR DHL9980545CCover · crackedAT C-CHECK, LT MLG DOOR UPLATCH COVER IS CRACKED ABOUT 1.5 INCH LONG. REMOVED AND FABRICATED UPLATCH COVER 8 X 5, PER SRM 51-3-0. N/R 597SDR UPS99828731Longeron · crackedINSPECTION TYPE-C123, LONG 24L CRACKED AT STA 870. REMOVED AND REPLACED LONG 24L.SDR DHL9980572CAngle · crackedAT C-CHECK, RT WING I/B FLAP FUS FILLET FAIRING ATTACH ANGLE CRACKED. REMOVED CRACKED ANGLE AND REMOVED FABRICATED NEW PER SRM 51-1-21, 21 X 1 X 1. N/R 413SDR DHL9980546CSkin · crackedAT C-CHECK, LT WING WHEEL WELL CUTOUT TO T/E PANEL VERT AFT SKIN LOWER CORNER HAS CRACK. REMOVED WEB AND FABRICATED LOWER CORNER AND INSTALLED PER SRM 51-1-21. N/R 581SDR DHL9980518CStrap · brokenAT C-CHECK, FWD OF AFT LOWER CARGO COMPT BETWEEN STA 1160 AND 1200 LONGERON 31L BROKEN FLOOR STRAP. REMOVED AND FABRICATED NEW FLOOR STRAP 10 X 3 AND INSTALLED PER SRM 51-1-21. N/R 870SDR DHL9980541CAngle · crackedAT C-CHECK, LOWER FUSE STA 620 APPROX STRINGER SUPPORT ANGLE CRACKED. FABRICATED NEW ANGLE, 3 X 2, INSTALLED PER SRM 51-1-21. N/R 719SDR UPS98828305Battery Pack · dischargedEMERGENCY LIGHT FAILED TO WORK DURING PRE-FLIGHT CHECK. REMOVED AND REPLACED EMERGENCY BATTERY PACK FOR EMERGENCY LIGHTS. OPS CHK GOOD.SDR DHL9980544CPanel · crackedAT C-CHECK, RT WING FLAP TRACK XW 219 ICE SHIELD HINGED PANELS HAVE RUB MARKS AND BOTH TRACKS HAVE RIB MARKS. REMOVED DAMAGED PANEL AND FABRICATED NEW SECTION PER SRM 51-1-8. N/R 592SDR UPS98828301Battery Pack · dischargedEEL ONLY STAY ON FOR A FEW SECONDS IN TEST. REMOVED AND REPLACED BATT PACK, OPS CHECK GOOD P/N ON 5708458-503 P/N OFF 60-1223-5 S/N ON FTL 1007 S/N OFF 327.SDR DHL9980556CSkin · crackedAT C-CHECK, NOSE LANDING GEAR WHEEL WELL FWD RT DOOR HINGE CUT OUT AFT SECTION HAD CRACK. STOP DRILLED CRACK AND FABRICATED REPAIR DOUBLER PER SRM 53-2-3, 7.5 X 5. N/R 306SDR DHL9980567CSkin · crackedAT C-CHECK, LT MLG WHEEL DOOR CUTOUT CRACKED FWD I/B CORNER. STOP DRILLED CRACK, FABRICATED DOUBLER REPAIR, INSTALLED PER SRM 53-2-3. N/R 211SDR DHL9980557CSkin · crackedAT C-CHECK, NOSE LANDING GEAR WHEEL WELL FWD LT DOOR HINGE CUT OUT AFT SECTION HAD CRACK. CLEANED DAMAGED AREA, STOP DRILLED CRACK AND FABRICATED REPAIR DOUBLER PER SRM 53-2-3. N/R 307SDR DHL98807008Control Cable · brokenAT 500 FT ABOVE THE RUNWAY FLAPS RETRACTED FULLY WITHOUT COMMAND. FOUND LEFT FLAP FOLLOW UP CABLE BROKEN. REPLACED CABLE RERIGGED FLAPS.SDR RRXA99628Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO ATTACHMENT ANGLE IN RIGHT MAIN LANDING GEAR TOP SECTION AT STA 857 AND BETWEEN WL-6 AND WL-8, DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLESDR DHL98806002Transformer · burnedFIRST OFFICERS FLUORESCENT BULBS WENT BRIGHT, THEN OUT. HEAVY SMOKE EMITTED FROM RT SIDE PANEL. TURNED OFF LIGHTS THEN SMOKE DISIPATED. REPLACED TRANSFORMER BALLAST PER MM 33-10-0, OPS CHECK GOOD.SDR DHL9980194CControl Cable · brokenAT C-CHECK, RIGHT WING LEADING EDGE FRONT SPAR AREA STA 421 NR 4 ENGINE CONTROL CABLE BROKEN. REMOVED, FABRICATED AND PULL TESTED CABLE PER MM 91-10-1. INSTALLED PER 76-11-0.SDR DHL9980155CFrame · crackedAT C-CHECK, MAIN CARGO DOOR LOWER FRAME AFT CORNER SECTION HAS A TWO INCH CRACK. WELDED CRACKED AREA PER DPS 10.225 AND INSTALLED LOWER FRAME AFT CORNER PER SRM 51-3-0 .SDR RRXA99228Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND FORWARD CARGO COMPARTMENT TWO FITTINGS AT APPROX STATION 300 AND 320, STRINGER RT 33, DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPLACED FITTINGS IAW DC-8 53-2-0 FIGURE 2D. (CORRO
Back to Douglas DC-8-73F