Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL9980146CStrap · damagedAT C-CHECK, AFT CARGO COMPT, STA 990 LT WALL PANEL SHOWS DAMAGED STRAP LOWER AREA. REMOVED DAMAGED STRAP, FABRICATED NEW STRAP AND INSTALLED PER SRM 51-3-0, 25 X 36.SDR UPS98825582Seat Track · corrodedINSPECTION TYPE-D, SEAT TRACK CORRODED BEYOND LIMITS AT FS 781 AND 798. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SECTION OF TRACK IAW SRM 53-7-2, 53-2-3, AND 51-1-21.SDR RRXA98431Frame · corrodedDURING A MAINTENANCE VISIT, FOUND FRAME PANEL CORRODED BEYOND LIMITS IAW DC-8 SRM, AT STA 1220 TO 1260, BL 52R AND WL -9. REMOVED PANEL, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW PANEL IAW DAC DWG 5750725 AND DC-8 SRM 52-2-0 FIGURE 2.SDR DHL9880686CBracket · crackedAT C-CHECK, NR 4 ENGINE HAS COOLING TUBE AFT MOUNT BRACKET CRACKED AT 5 O'CLOCK POSITION. REMOVED AND REPLACED BRACKET PER MM 20-16-0.SDR DHL9880685CBracket · crackedAT C-CHECK, ENG NR 4 TURBINE CASE COOLING AIR INTAKE TUBE AFT MOUNT BRACKET CRACKED, 10 O'CLOCK. REMOVED AND REPLACED PER MM 20-16-0.SDR DHL9880683CFloor Track · wornAT C-CHECK, FS 420 LINE NR 6 FLOOR TRACK WORN. CUT OUT DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR PLUG PER SRM 53-2-3 FROM FS 414 TO 418 AND FROM 421 TO 425.SDR DHL9880674CFloor Track · chippedAT C-CHECK, FS 460 LINE NR 3 FLOOR TRACK CHIPPED. CUT OUT DAMAGED AREA AND FABRICATED REPAIRPLUG PER SRM 53-2-3.SDR DHL9780673CFloor Track · damagedAT C-CHECK, MAIN CARGO COMPT FS 510 LINE NR 3 FLOOR TRACK HOLES ELONGATED. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR PLUG PER SRM 53-2-3.SDR UPS98825528Doubler · corrodedINSPECTION TYPE-D, DOUBLER AT FS 200 TO 220 LONG 28L EXFOLIATED OUT OF LIMITS (INTERNAL). REMOVED, FABRICATED, AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21 AND DWG 5773863.SDR UPS98825515Seat Track · corrodedINSPECTION TYPE-D, SEAT TRACK CORROSION REMOVAL BEYOND LIMITS FS 902 LBL 60. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SECTION IAW SRM 53-7-3.SDR DHL9880669CTrack · wornAT C-CHECK, MAIN CARGO COMPT FS 1680 LINE NR 3 TRACK WORN. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR PLUG PER SRM 51-3-0.SDR DHL9880668CCowl · crackedAT C-CHECK, NR 3 ENG AFT REVERSER COWL I/B AREA MID SURFACE HEAT SHIELD COVER DAMAGED. TRIMMED AREA AND FABRICATED REPAIR PER SRM 51-1-21.SDR DHL9880632CFrame · crackedAT C-CHECK, AFT BAGGAGE COMPARTMENT FWD BULKHEAD AT STA 980, GILL LINER FRAME SUPPORT IS DAMAGED AT UPPER AND LOWER AREAS. CUT OUT DAMAGED SECTION, FABRICATED REPAIR AND INSTALLED PER SRM 51-1-21, 3 X 10.SDR DHL9880630CFitting · crackedAT C-CHECK, SLIDE DOOR AFT CARGO AFT COMPT SLIDE DOOR LOWER AFT DOOR COVER SUPPORT FITTING IS CRACKED. REMOVED AND REPLACED SUPPORT FITTING PER SRM 51-1-21.SDR DHL9880607CFitting · crackedAT C-CHECK, RT WING I/B AILERON L/E DAMPER BRACKET CRACKED. REMOVED AND INSTALLED NEW FITTING PER SRM 51-1-21.SDR UPS98825505Doubler · corrodedINSPECTION TYPE-D, MAIN GEAR WHEEL WELL PRESSURE FLOOR UPPER SURFACE DOUBLERS CORRODED BEYOND LIMITS FS 879 TO 940 LBL 6 TO RBL 6. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT DOUBLERS IAW SRM 51-1-21 AND DWG 5645332-123, 125, AND 127.SDR UPS98825484Seat Track · wornINSPECTION TYPE-D, SEAT TRACK AT FS 861 RBL 47 IS WORN BEYOND LIMITS. REPAIRED IAW SRM ADDN DC8-5340-7779.SDR DHL99803002Valve · failedON CLIMB-OUT ABOVE 6000 FT AND AT OR ABOVE 230 KTS, FELT EXCESSIVE VIBRATION THOUGH OUT AIRFRAME. REMOVED AND REPLACED LATERAL CONTROL SPOILER POWER CYLINDER AND CONTROL VALVE (LEFT WING). OPS AND LEAK CHECKED PER MM 27-62-9.SDR DHL9880676CFloor Track · wornAT C-CHECK, FS 780 LINE NR 7 FLOOR TRACK WORN. CUT OUT DAMAGED SECTION OF TRACK AND INSTALLED PER SRM 53-2-3, 40 LONG.SDR DHL9880672CFloor Track · chippedAT C-CHECK, FS 650 LINE NR 3 TRACK IS CHIPPED. CUT OUT DAMAGED SECTION AND REPLACED PER SRM 53-2-3 FROM STA 648 TO 652.SDR DHL9880670CSeat Track · chippedAT C-CHECK, MAIN CARGO COMPT FS 860 NR 3 FLOOR TRACK CHIPPED. CUT OUT DAMAGED SECTION AND INSTALLED PLUG PER SRM 51-1-8 FROM STA 859 TO 863.SDR DHL9880649CFloor Track · wornAT C-CHECK, FUS STA 1600, LINE NR 6 FLOOR TRACK WORN AND DAMAGED. REMOVED SECTION, INSTALLED SPLICED AND NEW TRACK PER SRM 53-21-2, 40 LONG.SDR DHL9880620CSkin · corrodedAT C-CHECK, RUDDER AT STA ZR Z83 IN MOUNT HINGE CUTOUT TOP SKIN WEB AREA CORRODED. FOUND LEVEL 2 CORR. REMOVED WEB AND FABRICATED NEW PER SRM 55-1-0, 11.75 X 7.80. INSTALLED PER SRM 51-1-21.SDR DHL9880613CAngle · crackedAT C-CHECK, MAIN CARGO DOOR FWD LOWER CORNER SEAL RETAINER ANGLE CRACKED AT RADIUS. STOP DRILL AND FABRICATED REPAIR PER SRM 51-18, 2 FT X 2 FT.SDR DHL9880610CFitting · crackedAT C-CHECK, LT WING NR 1 SPOILER O/B CENTER HINGE FITTING CRACKED. REMOVED AND REPLACED FITTING PER MM 27-61-1.SDR UPS98825544Doubler · corrodedINSPECTION TYPE-D, COCKPIT SUBFLOOR FINGER DOUBLER CORRODED FS -40 RBL 55. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21 AND DWG 5612298.SDR UPS98825479Seat Track · wornINSPECTION TYPE-D, MAIN CABIN SEAT TRACK AT FS 420 RBL 60 HAS LUG WORN BEYOND LIMITS. REPAIRED IAW SRM 53-2-3.SDR DHL9880644CFairing · delaminatedAT C-CHECK, PYLON NR 4 ON RT SIDE OF PYLON ABOVE EXHAUST CASE AFT COWL FAIRING TO PYLON DELAMINATING. REMOVED, REPAIRED AND INSTALLED FAIRING PER SRM 51-3-0.SDR DHL9880664CPanel · crackedAT C-CHECK, COMPLY WITH DHL MSI 806-0913-1001, REMOVE AND REPLACE HORIZONTAL STAB CENTER SECTION, DUE TO CRACKED FASTENER HOLE. REMOVED AND REPLACED AFT UPPER PANEL PER S/B 55-15.SDR UPS98825547Floor Pan · corrodedINSPECTION TYPE-D, MAIN CABIN FLOOR PAN AT FS 1740 TO 1750 LBL 12 TO LBL 20 CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT IAW SRM 51-1-21 AND DWG 5755032.SDR UPS98825529Doubler · corrodedINSPECTION TYPE-D, INTERNAL DOUBLER AROUND A/C ACCESS CORRODED BEYOND LIMITS FS 8 TO 70 L-34R TO L-33R. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT DOUBLER IAW SRM 51-1-21 AND DWG 5649028.SDR DHL9880692CFloor Track · chippedAT C-CHECK, FS 1120 LINE NR 2 TRACK CHIPPED. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR PER SRM 53-2-3.SDR DHL9880688CFloor Track · chippedAT C-CHECK, FS 1130 LINE NR 4 FLOOR TRACK WORN/CHIPPED. CUT OUT DAMAGED SECTION, FABRICATED REPAIR AND INSTALLED PER SRM 53-2-3.SDR DHL9880687CFloor Track · chippedAT C-CHECK, FS 870 LINE NR 4 FLOOR TRACK CHIPPED. CUT OUT DAMAGED SECTION, FABRICATED REPAIR AND INSTALLED PER SRM 53-2-3.SDR DHL9880653CSeat Track · wornAT C-CHECK, STA 860 LINE NR 5 FLOOR TRACK WORN. CUT OUT DAMAGED SECTION OF TRACK, INSTALLED SEAT TRACK AND SPLICE. REPAIRED PER SRM 53-2-3, 25 LONG.SDR DHL9880634CHousing · crackedAT C-CHECK, REAR CARGO COMPT AFT CARGO DOOR UPPER CEILING AREA METAL HOUSING NEXT TO DOOR HINGE IS CRACKED. STOP DRILLED AND INSTALLED REPAIR DOUBLER 4 X 3 PER SRM 53-2-0.SDR UPS98825504Support · corrodedINSPECTION TYPE-D, MAIN CABIN FLOOR BOARD SUPPORT CORROSION REMOVAL BEYOND ALLOWABLE LIMITS FS 1680 RBL 5 TO RBL 28. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SUPPORT IAW SRM 57-7-3 FIG 5A.SDR UPS98825421Support · corrodedINSPECTION TYPE-D, MAIN CABIN FLOOR BOARD SUPPORT CORROSION REMOVAL BEYOND LIMITS FS 1715 RBL 10 TO LBL 10. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT SUPPORT IAW DWG 5755032, SRM 53-7-3 AND 51-1-20.SDR DHL9880615CBrackett · crackedAT C-CHECK, LT MAIN LANDING GEAR STRUT CENTER DOOR AFT LOWER BRACKET CRACKED AT I/B ATTACH POINT. REMOVED AND REPLACED BRACKET PER MM 32-1-21.SDR UPS98825532Fitting · crackedINSPECTION TYPE-D, TORQUE BOX FITTING CRACKED AT FS 280 BETWEEN L-35L AND L-36. REMOVED AND REPLACED FITTING IAW SRM 53-2-0.SDR UPS98825427Doubler · corrodedINSPECTION TYPE-D, MAIN W/W PRESURE FLOOR UPPER SURFACE FINGER DOUBLER CORRODED BEYOND LIMITS F/S 960 TO 980 RBL 62 TO 69. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT DOUBLER IAW DWG 5645332 AND SRM 51-1-21.SDR UPS98825417Longeron · corrodedINSPECTION TYPE-D, LONGERON 36 AT FS 220 CORRODED BEYOND LIMITS. REMOVED AND REPLACED LONG IAW SRM 51-1-21 AND 51-1-20D.SDR UPS98825534Spar Cap · crackedINSPECTION TYPE-D, LT HORIZ STAB ATTACH ANGLE INSIDE AUX SPAR AREA CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-1-20 AND 51-1-21.SDR UPS98825380Battery Pack · dischargedINSPECTION TYPE-N/A JUST PRIOR TO TAXI OUT, EMERGENCY LTS ON WITH SW IN ARM POSITION. REMOVED AND REPLACED EMERGENCY BATTERY PACK. ALSO, FOUND PIN PUSHED BACK ON CONNECTOR. REPAIRED PIN EMERGENCY LTS, OPS CHECKED GOOD PER MM 33-50-00.SDR RRXA98432Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND LOWER CARGO DOOR FRAME FITTING CORRODED BEYOND LIMITS IAW DC-8 SRM, AT STA 300 TO 320, BETWEEN LONGERONS 32 RIGHT AND 34 RIGHT. REMOVED FITTING, TREATED AREA IAW DC-8 SRM. FABRICATED AND INSTALLED NEW FITTING IAW DC-8 SRM 53SDR RRXA98020Skin · crackedDURING A MAINTENANCE VISIT, FOUND LEFT WING SKIN PANEL WITH CRACK BEYOND LIMITATIONS IAW DC-8 SRM AT, XW 408 TO XS457. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW FAA DER APPROVED COTNEY ENGINEERING SKETCH D85-R02 AND DC-8 SRM 51-1-21.SDR RRXA98019Skin · corrodedDURING A MAINTENANCE VISIT, FOUND INTERIOR SKIN CORRODED BEYOND LIMITATIONS IAW DC-8 SRM AT, STA 660 AND BETWEEN LONGERONS 32 RIGHT AND 33 RIGHT. REMOVED ALL CORROSION AND TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER REPAIR ISDR DHL9880625CTrack · wornAT C-CHECK, RT WING FLAP CENTER HINGE UPPER VANE TO FLAP ATTACH FRAME BADLY WORN ON RIGHT SIDE. REMOVED DAMAGED TRACK ASSY PER SRM 51-3-0 AND INSTALLED NEW TRACK PER SRM.SDR DHL9880623CFairing · dentedAT C-CHECK, LEFT ELEVATOR AT ELEVATOR MOUNT FITTING CUTOUTS UPPER AND LOWER FAIRINGS DENTED, CRACKED AND BENT. STRAIGHTENED DEFORMITY, RESTORED TO ORIGINAL CONTOUR. TRIMMED CRACKED AREA, PERFORMED DYE PEN AND NO CRACK NOTED.SDR DHL9780601CSill · dentedAT C-CHECK, B-2 DOOR SILL DENTED. REMOVED AND REPLACED SILL PER SRM 51-21-21.
Back to Douglas DC-8-73F